Iron Air Charge 2510-SXT Installation & Start-Up Guide

Similar documents
Pro-OX 7800 Iron Filter Installation & Start-Up Guide

7500 Pro-Ox Filter Installation & Start-Up Guide

Stenner Pump Chlorinator Installation & Start Up Guide

Fleck 7000 Softener Installation & Start-Up Guide

Clean Water Made Easy

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Calcite PH Nutralizer System

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

10/20 COMBINATION UNIT

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

Owner s Manual / 5600 Econominder

Inline Chlorinator Chlorine Chemical Feeder

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Maintenance Guide For Above Ground Pools

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

WATER SOFTENER SYSTEMS

Water Tec of Tucson Water Systems

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS

Troubleshooting a Greensand Plus filter system

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

AMX300 DirectConnect Mixing Valve Kits

Metermatic SE Automatic Water Softener. Operation Manual

Global New Product Development EWT 610HE/611HE Model

Ion Exchange Softening

Water Treatment Solutions for Residential & Light Commercial Applications

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

FILLING AND PURGING THE SYSTEM

OTF Oil Fired Pool Heater

Air Conditioner Water Heater Model ACWH18

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Line to Refrigerator Ice/Water Dispenser

NITROUS TRANSFER PUMP INSTRUCTIONS

Model 5600 & 5600 Econominder

485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

INSTALLATION AND SERVICE MANUAL

Dealer Sales & Service Guide

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Model 5600 & 5600 Econominder

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

EcoSoft Water Softener. General Installation Guide

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

How To Replace A Reverse Osmosis Water Tank

COMPRESSED AIR DRYER

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

B150 Series Commercial Brewer. Direct Plumb Kit

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

MODEL Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Overheating limit control

Model 5600SE Downflow

3M Iron Reduction Filtration Systems

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Water Treatment & Purification Chemicals


Elgin Fire Department

Water Specialist 1 Control Valve Series Model: WS1

RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1

Water Tec of Tucson Water Systems

QuickAir - 5, - 10 Minute Emergency Escape Breathing Apparatus. Operating Manual

123 Industrial Loop Road Paynesville, MN Phone:

Compressor Service & Maintenance Manual

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Autotrol Series 255 Valve / 440i Control. Water Conditioning Control System Installation, Operation and Maintenance Manual

Common Causes of High Water Bills

Disinfecting Your Private Well

INSTALLATION AND SERVICE MANUAL

Installation Instructions S

for Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling

SunMaxx Solar Filling Station Operating Instructions

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175

How To Remove Iron From Water

Operating and Service Manual SXT Automatic Chloramines Removal Filter. Made in Canada

Indiana Department of Environmental Management. Well Disinfection

MODEL #320 - (* Using Bromine tablets with this device is not NSF certified)

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Air Eliminators and Combination Air Eliminators Strainers

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

ACCUMULATOR INSTALLATION

Iron and Manganese BACTERIA AND IRON AND MANGANESE

NFPA31FuelOilPiping 1 Revised

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

20 GALLON WET DRY VACUUM

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

PAINT SPRAY GUN WASHER

High kw Electric Tankless Water Heater Troubleshooting Guide

Transcription:

Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water for many years. Please review this start-up guide entirely before beginning to install your system and follow the steps outlined for best results. MEDIA CONTAINS DUST. USE PAPER MASK AND VENTILATE TO AVOID BREATHING DUST. 2806-A Soquel Ave Santa Cruz CA 95062 For assistance call: 1-831-462-8500 Packing List by Model 1.0 Cubic Foot 2510 SXT Air Charger: Email us: office@cleanwaterstore.com More information online: www.cleanwaterstore.com

Packing List by Model Each system comes with the following: 1 Fleck 2510-SXT Backwash Control Valve with Pipe connector kit (either 1 or ¾ )* 1 Fleck 2510-SXT Bypass valve 1 Enpress filter tank with distributor tube installed 1 Media funnel * We include two extra red clips with the pipe connector kit. In addition, each system comes with the following, depending on the model ordered: 1.5 Cubic Foot Air Charger Iron Filter 2510-AIO: Quantity Description 1 ½ cubic foot box of AIO Filter Base Media 1 1 cubic foot box of Birm Media 2.0 Cubic Foot Air Charger Iron Filter 2510-AIO: Quantity Description 1 ½ cubic foot box of AIO Filter Base Media 1 1 cubic foot box of Birm Media 1 ½ cubic foot box of Birm Media 2.5 Cubic Foot Air Charger Iron Filter 2510-AIO: Quantity Description 1 ½ cubic foot box of AIO Filter Base Media 2 1 cubic foot box of Birm Media Media Boxes As Shipped, and Box Contents: REV 070914 Page 1

The Air Charger AIO Filter, when properly applied, is an efficient and cost effective system for the removal of iron and Iron. The AIO control valve maintains a compressed air pocket in the top of the tank while the system is in service. As the water passes thru the air pocket, iron and Iron are oxidized. Additionally, dissolved oxygen is added to the water. The Air Charger AIO filter media bed then removes the iron and Iron from the water. Fig 1 - AIO 2510 SXT Control Valve, Front View A daily backwash will remove accumulated iron and replenish the filter media bed. The regeneration process also adds a fresh air pocket to the system. Application Parameters w / Iron-Iron Removal Media ph (Minimum) 6.8 Iron (Maximum) Iron (Maximum) Service Flow (Maximum) Backwash Flow (Minimum) 7 ppm 4 ppm 8 gpm 3.0 gpm REV 070914 Page 2

Pre-Installation 1. If you are going to be turning off the water to the house and you have an electric water heater, shut off the power to the water heater before beginning installation in case water heater is accidentially drained. 2. Pick a suitable location for your filter system on a dry level spot where it won t be exposed to freezing temperatures. A minimum of 20 PSI is required. Maximum pressure is 90 PSI. 3. Get all of your plumbing parts together before beginning installation. Installation typically takes 3 to 5 hours. However after installation the 2510 SXT Air Charger Filter must be allowed to run through a complete backwash and rinse cycle. 4. After the system is installed and running, your water may be discolored, or full of sediment or rust, particularly if this is older or corroded piping. Typically this clears up over a day or two. Assembly and Installation Instructions 1. The 2510 SXT Air Charger filter is installed after the pressure tank. If you are also installing a water softener, install the softener after the 2510 SXT Air Charger filter. 2. Make sure to follow to connect the in pipe to the Fleck 2510 SXT inlet and the outlet to the outlet (see Fig 2). As you face the Fleck 2510 SXT control from the front, the water enters on the right and exits on the left. From the back (see Fig 2) the water enters on the left. The inlet and outlet are attached to the bypass valve which is marked with arrows as well. 3. Make sure there is a working gate or ball valve before the Fleck 2510 SXT Air Charger filter and also one after. Pressure gauges are optional and perhaps not necessary but a hose bib (which is a faucet that you can attach a garden hose to) is strongly recommended after the 2510 SXT Air Charger filter before the second ball valve. This makes it easy to rinse your new 2510 SXT Air Charger filter on startup and gives you a place to test the water before it enters your household plumbing. 4. If you will be using copper piping, do not sweat the copper pipe directly on to the Fleck 2510 SXT control valve. Avoid heating up the Fleck 2510 SXT control valve plastic with the torch. 5. You do not need unions to install your Fleck 2510 SXT control. If you need to remove it, the Fleck 2510 SXT has quick-release couplings that make it easy to put the 2510 SXT Air Charger filter on by-pass and remove the filter system from the piping. 6. The drain line tubing (not supplied) is connected to a drain from the drain outlet using flexible ½ ID tubing. Note that the drain can run up above the Fleck 2510 SXT control and into a drain, it does not have to drain down, as the filter backwashes under line pressure from your well pump. REV 070914 Page 3

Fig 2 - AIO 2510 SXT Control Valve, Back View 7. Insure the brine line check valve with screen is installed on the brine valve (See Fig. 2) This is the AIR DRAW point of entry. System Limitations Chlorine or other strong oxidizers will damage the filter media bed of theses systems and should never be used. The Air Charger Filter utilizes air, oxidation and filtration for the removal of Iron and Iron. This process will leave some air or effervescence in the water. The effervescence may give the water a milky appearance and is simply excess air in the water. While a certain amount of effervescence will always be present, it may be most noticeable during the first 30 days. REV 070914 Page 4

Media Loading Guide 1. Place the media tank on a level surface in an area with adequate ventilation. Proper precautions should be taken to cover your eyes, mouth and nose before pouring the media into the tank. 2. After removing the control valve, center the riser tube in the tank and place the PVC cap on the riser to prevent media from entering the tube. It is important that the riser tube stays properly centered in the tank as the media is installed. 3. Attach the plastic diffuser cone to the distributor tube (see right). In order to do this, swab PVC glue on the distributor tube 4 inches below threads on the tank. The diffuser cone can then be slipped over the distributor and attached to this location. See Fig. 1 for an idea of placement. 4. The Base Media layers are bagged and marked Media 1, Media 2 and Media 3. It is necessary to load the tank beginning with the bag marked Media 1 (this is Garnet) followed by the bag marked Media 2 (Filter Sand), finally installing Media 3 (KDF 85). For proper operation of the system, the media must be properly layered in the tank. Once the first three media layers are installed, add the boxes marked BIRM to the tank. 5. Once the media has been installed, carefully assemble the valve to the tank. The riser tube must be properly centered in the valve and should not be forced as the valve is installed. The check valve that is provided must be installed on the inlet of the unit. 6. Complete the installation process per local plumbing code. REV 070914 Page 5

Bypass Assembly The system must be backwashed once upon startup. First, put the system into service mode. Normally the system ships in the bypass position. Once the system is properly plumbed in, make sure to turn both of the bypass valve knobs 90 degrees into service mode. Regeneration Cycle (59 minutes) 1. Backwash (14 minutes) During this cycle, the water carrying the iron runs to the drain. Untreated water is available during regeneration. 2. Air Recharge (40 minutes) during this cycle, the unit empties water to the drain and is recharged with air. The sound of air being recharged will be heard. Air bubbles should go down to the drain before proceeding to the next step. Adjust cycle time if necessary. 3. Rapid Rinse (5 minutes) During this cycle, water enters the tank, compressing the air into a pocket at the top of the tank. 4. Brine Refill (Off) 5. Unit Returns to the In-Service Position The frequency and time of regeneration can be changed due to the following reasons. In conditions of high water usage and/or high levels of iron, the unit may need to regenerate more frequently than once every three days. The unit can be set for daily regeneration or to regenerate every two days. DO NOT set the regeneration frequency for a longer period than 3 days, as the filter medium can become fouled with iron, rendering the unit ineffective. REV 070914 Page 6