Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener
|
|
|
- Godwin Richardson
- 10 years ago
- Views:
Transcription
1 Water Tec of Tucson WS1TA Twin Alterna ng Water so ener Water Tec of Tucson S. 3 RD Avenue Tucson, AZ (520) Fax (520)
2 MAIN COMPONENTS Your water treatment system is a Twin Alt point of entry (POE) system composed of four components: A. The control valve and computer assembly The fiberglass tank assembly's including the water treatment medium The brine tank assembly including safety float. Each of these assemblies has a specific func on as described below: Control Valve Assembly Automa cally monitors water usage pa erns, ini ates regenera on and moves the valve through the steps of regenera on. Media Tank Assembly A fiberglass vessels, which contains the water so ening media, in the proper diameter and depth of the media and evenly distributes the feed water throughout the media tank assembly. Brine Tank Assembly A polyethylene vessel, which is used to dissolve salt and to hold the proper amount of brine for the next regenera on. A brine valve keeps the control valve from drawing air into the system. STEPS OF OPERATION Service Hard water flows downward through the water so ening resin where the hardness minerals, calcium and magnesium, as well as dissolved iron, are removed from the water and are collected on the resin. The amount of resin and the salt dosage gives resin a certain capacity for hardness and iron removal. Backwash 1 During the cycle the water flows upward through the resin bed and washes collected sediment or other foreign material to the drain. Brine and Rinse The brine solu on is drawn from the brine tank and slowly flows downward through the resin collec ng the hardness and iron as it goes. The brine carries the hardness and iron with it and rinses them to the drain. Backwash 2 Same as backwash 1 above but of slightly shorter dura on. Fast Rinse Water flows downward through the resin and to the drain carrying with it the remaining traces of brine. Brine Tank Refill A predetermined volume of water flows into the brine tank and dissolves a calculated amount of salt crea ng brine for the next genera on. This occurs at the onset of the next Service cycle. Be sure that there is always un dissolved salt remaining. Since the frequency of regenera on is reasonably consistent, a regular addi on of salt should be scheduled. Approximately 6" 8" of salt must be in brine tank. In some cases the installa on technician may decide a pre brine refill may be appropriate. If so brine refill will occur 2 hours prior to regenera on and will result in minimal water in the brine tank assembly during service posi on. Total Regenera on Time (Backwash 1 through Fast Rinse) can be anywhere between 57 and 107 minutes depending on se ng made for certain water condi ons.
3 GENERAL CARE AND MAINTENANCE INFORMATION The following guidelines are recommended for you to obtain maximum efficiency from your water treatment system: Control Valve Try to keep free of dirt and debris both on valve body and under cover. No lubrica on is required. Brine Tank A major cleaning is recommended every two years. This interval may need to be adjusted depending on the amount of insoluble material in the salt being used. Allow salt level to become very low so there is li le to remove. Scoop out un dissolved salt. Disconnect and remove brine valve. There is no pressure or suc on on this line except during a regenera on. Remove internal parts of brine tank, if any. Clean brine tank interior with a mild cleaning agent (dish soap) and rinse thoroughly. Replace brine valve and internal parts. Pour five gallons of water (so ened if available) into the tank (Add only two gallons if pre brine refill op on is used). Add salt. Replace cover. Allow two hours for concentrated brine to be made before next regenera on. It is recommended that a manually ini ated regenera on should be started now. See Manual Regenera on.
4 GENERAL INSTALLATION & SERVICE CAUTIONS The control valve, fittings, and/or bypass are designed to accommodate minor plumbing misalignments they are not designed to support the weight of a system or the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants, or silicone spray anywhere. Do not use silicone on red or clear lip seals. Do not use pipe dope or other sealant on threads. Teflon tape must be used on the threads of the 1" NPT elbow, its ¼" NPT connec ons, and on the threads for the drain line connec on. Teflon tape is not used on the nut connec ons or caps because o ring seals are used. The nuts and caps are designed to be unscrewed or ghtened by hand or with the special plas c Service Wrench, CLV V3193(models with Clack control valves). If necessary, pliers can be used to unscrew the nut or cap. Do not use a pipe wrench to ghten nuts or caps. Do not place screwdriver in slots, on caps, and/or tap with a hammer. SITE REQUIREMENTS Water Pressure, psi Water Temperature, 40º 110º F The tank should be on a firm level surface Electrical: Use a 115/120V, 60Hz uninterrupted outlet. Current draw is 0.25 amperes A 15. power cord is furnished The plug in transformer is for dry loca ons only. Ba eries are not used.
5 The distance between the drain and the water condi oner should be as short as possible. Since salt must be periodically added to the brine tank, the tank should be located where it is easily accessible. Do not install any water condi oner with less than 10 feet of piping between its outlet and the inlet of a water heater. Do not locate unit where it or its connec ons (including the drain and overflow lines) will be subjected to temperatures at or below 34ºF. The use of resin cleaner in an unvented enclosure is not recommended. Do not install equipment in loca ons that would receive rain run off from roof. INLET/OUTLET PLUMBING: Connect to a supply line downstream of outdoor spigots. Install an inlet shutoff valve and plumb to the units bypass valve inlet located at the right rear as you face the unit. When assembling the installa on fi ng package (inlet and outlet), connect the fi ng to the plumbing system first and then a ach the nut, split ring and O ring. Heat from soldering or solvent cements will damage the nut, split ring or O ring. Solder joints should be cool and solvent cements should be set before installing the nut, split ring and O ring. Avoid ge ng solder flux, primer, and solvent cement on any part of the o rings, split rings, bypass valve, or control valve. If the building s electrical system is grounded to the plumbing install a coppergrounding strap from the inlet to the outlet pipe. Plumbing must be done in accordance with all applicable local codes. DRAIN LINE: First, be sure that the drain can handle the backwash flow of the system. Solder joints near the drain must be located prior to connec ng the drain line flow control fi ng. Leave at least 6" between the drain line flow control fi ng and solder joints. Failure to do so could cause interior damage to the flow control. Install a 3/8" 1/2" I.D. flexible plas c tube to the Drain Line Assembly or discard the tubing nut and use the ¾" NPT fi ng for rigid pipe. If the backwash rate is greater than 7 gpm, use a ¾" drain line. Run drain tube to its discharge point in accordance with plumbing codes. Pay special a en on to codes for air gaps and ant siphon devices. 9. BRINE TANK CONNECTION: Install a 3/8" O.D. polyethylene tube from the Refill Elbow to the Brine Valve in the brine tank. 10. OVERFLOW LINE CONNECTION: AN OVERFLOW DRAIN LINE IS RECOMMENDED ANYWHERE A BRINE OVERFLOW COULD DAMAGE FURNISHINGS OR THE BUILD ING STRUCTURE. Your so ener is equipped with a brine tank safety float, which greatly reduces the chance of an accidental brine overflow. In the event of a malfunc on, an OVERFLOW LINE CONNECTION will direct the overflow to the drain instead of spilling on the floor. This barb type fi ng should be on the side of the cabinet or the brine tank. To connect the overflow fitting, locate the hole inside of brine tank. Insert overflow fitting into tank and tighten with plastic thumbnut from the inside. Attach a length of ½" I.D. tubing (not supplied) to the fitting and run to drain. Do not elevate overflow line higher than 3" below bottom of overflow fitting. Do not connect this tube into the drain line of the control valve. Overflow should be a direct, separate line from overflow fitting to drain, sewer, tub, or appropriate outdoor location. Allow an air gap as per the drain line instructions. IMPORTANT: Never insert a drain line directly into a drain, sewer line, or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the water conditioner.
6 1) Connect second tank to main control valve. 2) Connect Brine Tank 3) Connect Drain 4) Connect inlet & Outlet Installa on and Startup 5) Program Regenera on Capacity in gallons (see next page) **All control programming with the excep on of the Regen Capacity is done at the factory. 6) Perform a manual Backwash and rinse Cycle on each tank. Press and hold REGEN bu on for 5 seconds to start a regenera on let the first backwash complete and then skip the Brine & Rinse cycle by pressing the Regen bu on when mer starts coun ng down. Allow the next cycle to complete then skip the Fill Cycle for the first tank. Repeat these steps for the second tank ( DO NOT skip the fill cycle on the second tank). The system is now ready for use. Drain Inlet Outlet Second Tank Adaptor Inter connector Brine tank connec on ***Do not remove red clips on Brine Tank connec on or Drain connec on, these clips are retainer clips and must be installed for proper opera on.
7 Use calcula on BELOW to set capacity using the tested HARDNESS. OFF **OFF** Factory se ng ** 2:00 AM** The unit will regenerate when the meter reaches 0**Factory se ng Unit capacity / hardness = Volumetric Capacity Unit Capaci es based on tank size TANK SIZE CAPACITY TANK SIZE CAPACITY 08X35 12,000 12X52 48,000 08X40 18,000 13X54 60,000 09X48 24,000 14X64 72,000 10X35 24,000 16X65 96,000 10X44 30,000 18X65 120,000 10X54 36,000 21X62 144,000
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23 Please do not hesitate to call with any ques ons regarding Installa on or service. WATER TEC OF TUCSON 4601 S 3RD AVENUE TUCSON AZ (520)
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Softener Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version
MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
WATER SOFTENER SYSTEMS
INSTALLATION MANUAL WATER SOFTENER SYSTEMS HousePure Models HP-Soft-2 HP-Soft-4 736-0137 Water, Inc. 1044 East Del Amo Blvd., Carson, CA 90746 www.waterinc.com 310-885-4400 P/N 41482 Rev A 06/04 Table
Model 5600SE Downflow
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
Water Specialist 1 Control Valve Series Model: WS1
Water Specialist 1 Control Valve Series Model: WS1 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training of the OEM and for the OEM to use
MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model
Model 5600 & 5600 Econominder
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
Model 5600 & 5600 Econominder
Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet.........................................................................
10/20 COMBINATION UNIT
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic
Owner s Manual. 5600 / 5600 Econominder
5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Fleck 7000 Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Owner s Manual. 12 Volt Electronics
12 Volt Electronics Owner s Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597 Phone: 608-849-3050 Fax 608-849-7398 Web: www.hellenbrand.com Email: [email protected]
MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL
Clean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
EcoSoft Water Softener. General Installation Guide
EcoSoft Water Softener General Installation Guide Planning Our Softener Installation Please observe any local or national regulations concerning the installation of your water softener. Check that there
Metermatic SE Automatic Water Softener. Operation Manual
Metermatic SE Automatic Water Softener Operation Manual Page 7 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly
Thank you... Welcome to your new world of better living with water2buy s Aquasmart Water softeners. How your Aquasmart TM water softener works
Thank you... Welcome to your new world of better living with water2buy s Aquasmart Water softeners. If this is your first experience of Aquasmart softened water in your home, you ll be amazed at the marvelous
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]
Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.
Owners Manual 485HE High Efficiency Water Softener Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association. 1. Read all instructions carefully before
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1
R Water Conditioning Owner s Manual R4039 RXD Water Softener This manual contains information on setting the controller and normal operating maintenance required by the owner. Page 1 UNPACKING INFORMATION
Ice Maker. User Manual HI6LMK. www.haieramerica.com. Haier America New York, NY 10018 2013 Haier America Trading, LLC.
Ice Maker User Manual HI6LMK www.haieramerica.com Model # HI6LMK Issue Date: April 2013 120 V, 60 Hz Made in China Haier America New York, NY 10018 2013 Haier America Trading, LLC. TABLE OF CONTENTS SAFETY
Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual
Series 255 Valve / 460i Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Introduction............................... 2 Series 255/460i Demand Control System
Pro-OX 7800 Iron Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Pro-OX 7800 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
ProMate EcoMax. Consumer s Manual
ProMate EcoMax Consumer s Manual Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road Waunakee, Wisconsin 53597 Web: www.hellenbrand.com Email: [email protected] 800664 Rev A. 7/22/15 2015 This
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:
Operation Manual 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer: Your local dealer is: TABLE OF CONTENTS LOGIX SERIES INSTALLER QUICK-START
INSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL Model 550, 700 and 900 Water Softeners Version 4 WaterBoss 4343 S. Hamilton Road, Groveport, Ohio 43125 Table of Contents QUESTIONS?... 1 GETTING MAXIMUM EFFICIENCY FROM
8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.
8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and
Autotrol Series 255 Valve / 440i Control. Water Conditioning Control System Installation, Operation and Maintenance Manual
Autotrol Series 255 Valve / 440i Control Water Conditioning Control System Installation, Operation and Maintenance Manual 1 Table of Contents Introduction... 2 Superior Design Superior Operation Installation...
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590
OWNER S MANUAL MODEL NOS. 625.348570 625.348590 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or
PRF 368 Valve. Installation and Operation Manual TABLE OF CONTENTS SAFETY INFORMATION MANUAL OVERVIEW. How To Use This Manual
PRF 368 Valve Installation and Operation Manual TABLE OF CONTENTS MANUAL OVERVIEW...1 SAFETY INFORMATION...1 TYPICAL TOOLS AND FITTINGS REQUIRED...2 VALVE DIMENSIONS- 368...2 VALVE LAYOUT - 368...2 SPECIFICATIONS...3
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Finding and Fixing Leaks
Finding and Fixing Leaks Where did all that water go? Could we have splashed all that water out of the tub? These are all common thoughts that can run through your mind when you open up the hot tub cover
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities
Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
Installation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Grease Trap Maintenance, Procedures and Cleaning Logs
SAWS Grease Reduction Program Grease Trap Maintenance, Procedures and Cleaning Logs Don t Feed the Grease Monster Best Management Practices for Commercial Food and Restaurant Facilities Train kitchen staff
OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION
OPERATING INSTRUCTIONS Shortening Filter Model No. 99-A, 102-A, & 107-A Series TABLE OF CONTENTS PAGE Installation... 2 Operating... 3 Cleaning... 5 Parts List... 6 & 7 Troubleshooting... 8 LIMITED WARRANTY
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 7000SXT Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 TIMER FEATURES...3 TIMER OPERATION...4 MASTER PROGRAMMING MODE CHART...5 MASTER PROGRAMMING
Installation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
To Repair or Replace?
U- Fix It Workshop To Repair or Replace? How old are the fixtures you are repairing? Will cost or risk of repair outweigh the cost of replacing the fixture/appliance? New water saving fixtures may be best
SIGNATURE 2 SERIES. Greensand Plus Iron Filter Manual. Installation / Operation Manual
Greensand Plus Iron Filter Manual Installation / Operation Manual Filter Specifications...Page 2 Installation...Page 3 Control Start-Up Procedures...Page 8 Utilizing Bluetooth...Page 11 Master Programming...Page
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
Water Softening. system. GE Appliances. Safety Instructions Proper installation...3. Owner s Manual & Installation Instructions
GE Appliances Water Softening system Safety Instructions Proper installation............3 Installation Instructions Drain connections..........7, 8 Important recommedations....4 Installation instructions......4-6
7500 Pro-Ox Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 7500 Pro-Ox Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)
Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) IMPORTANT: It is imperative that the user read these warnings and use of the assembly instructions
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
IMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
User and Installer Handbook
User and Installer Handbook User and Installer Handbook Tapworks Softener Models Ultra 9, AD11, AD15 & AD15 Infinity User and Installer Handbook Tapworks Softener Models Ultra 9, AD11, AD15 & AD15 Infinity
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Prevent Blockages in the Sanitary Sewer System
FATS, OILS & GREASE - BMPs The following Best Management Practices (BMPs) tables are listed below: Prevent blockages in the Sanitary Sewer System Properly Maintain Grease Traps and Interceptors to Prevent
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket
Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket IMPORTANT: Please read these instructions completely and carefully before installing Universal s 71CD-1212 Spill Containment
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures
KEY CONCEPTS 1. Identify tools for plumbing 2. Location of shutoff valves for the main and individual fixtures 3. How water is supplied to your home 4. How waste water is removed and treated 5. Common
Installation and Operating Instruction Manual
Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
Estimated Water Savings
Easy Plumbing Fixes Estimated Water Savings A family of 4 could save: 200 gpd by fixing toilet leaks 20 gpd by fixing faucet leaks 100 gpd by installing low-flow showerheads 40 gpd using faucet aerators
Global New Product Development EWT 610HE/611HE Model
Global New Product Development /611HE Model /611HE Valve Specifications Specifications The /611HE 1 valve can be used in filter or softener applications with tank sizes up to 16 in diameter. The valve
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
MODEL #320 - (* Using Bromine tablets with this device is not NSF certified)
RAINBOW CHLORINE/BROMINE* FEEDER MODEL #320 - (* Using Bromine tablets with this device is not NSF certified) Features: No special venting required. Completely enclosed-no escaping gases. Positive external
Cleaning & Sanitisation
Cleaning & Sanitisation Notice: The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler Service Technician only. Never attempt to service
COMPRESSED AIR DRYER
COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
Water Pump Replacement
1 of 8 2/5/2008 6:36 AM Document ID# 713637 2001 Cadillac Seville Print Water Pump Replacement Tools Required 1. J 38816-A Water Pump Remover & Installer 2. J 38185 Hose Clamp Pliers
Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual
Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus
OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks
OWNER S MANUAL for FOOTWORKS tm Faucet Controller Foot Operated Faucet Control Valves for Commercial Sinks - 1 - Introduction Congratulations on your purchase of a FOOTWORKS tm Faucet Controller, an engineered
Plugging Home Drains to Prevent Sewage Backup
AE-1476 Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or heavy rain, taking a few steps to prepare for water levels that could result
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Application Outboards Faria 5 Gauge Set* Publication No. Description Part Number Honda Code PII53606A White faced, flat lens 06300-ZW5-010ZB 6315410 Issue Date Black faced, flat
Self Purging Liquid Trap (SPLT ) User s Manual
Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Operating and Service Manual. 6200 SXT Automatic Chloramines Removal Filter. Made in Canada
Operating and Service Manual 6200 SXT Automatic Chloramines Removal Filter Made in Canada Introduction Read this Manual First Read this manual thoroughly to become familiar with the device and its capabilities
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Air Conditioner Water Heater Model ACWH18
Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
Installation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
OWNERS MANUAL. Model No. 45-0292 15 GALLON "PRO" TOW SPRAYER
OWNERS MANUAL Model No. 45-0292 CAUTION: Read Rules for Safe Operation and Instructions Carefully Assembly Operation Maintenance Repair Parts 15 GALLON "PRO" TOW SPRAYER PRINTED IN USA FORM NO. 47628 (REV.
Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
