1 Operating and Service Manual 6200 SXT Automatic Chloramines Removal Filter Made in Canada

2 Introduction Read this Manual First Read this manual thoroughly to become familiar with the device and its capabilities before installing or operating your Water Filter. Failure to follow instructions in this manual could result in personal injury or property damage. This manual will also help you to get the most out of your filter. This system and its installation must comply with state and local regulations. Check with your local public works department for plumbing and sanitation codes. In the event the codes conflict with any content in this manual the local codes should be followed. For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of this system. This water filter is designed to operate on pressures of 20 psig 125 psig. If the water pressure is higher than the maximum use a pressure reducing valve in the water supply line to the softener. This unit is capable of operating at temperatures between 40 F and 110 F (4 C - 43 C). Do not use this water filter on hot water supplies. Do not install this unit where it may be exposed to wet weather, direct sunlight, or temperatures outside of the range specified above. Do not use water that is microbiologically unsafe without adequate disinfection before or after this system. This publication is based on information available when approved for printing. Continuing design refinement could cause changes that may not be included in this publication. WaterGroup reserves the right to change the specifications referred to in this literature at any time, without prior notice. Safety Messages Watch for the following safety messages in this manual: NOTE: used to emphasize installation, operation or maintenance information which is important but does not present a hazard. Example: NOTE: Check and comply with you state and local codes. You must follow these guidelines. CAUTION: used when failure to follow directions could result in damage to equipment or property. Example: CAUTION! Disassembly while under pressure can result in flooding. WARNING: used to indicate a hazard which could cause injury or death if ignored. Example: WARNING! ELECTRICAL SHOCK HAZARD! UNPLUG THE UNIT BEFORE REMOVING THE COVER OR ACCESSING ANY INTERNAL CONTROL PARTS NOTE: Do not remove or destroy the serial number. It must be referenced on request for warranty repair or replacement 1

3 Basic Principles The success of the installation will depend, to a great extent, on advanced planning and preparation. Careful attention to the location of the unit, accessibility to electrical and drain facilities, and the availability of the proper tools will ensure a professional-looking installation. Of utmost importance is the assurance that the filter has been properly applied and meets all specifications. Application Correct application is directly associated with the performance and life expectancy of any water filter. It is important, therefore, to understand how your WaterGroup Water Filter functions and to know its capabilities and limitations so that a correct application can be made. By following the guidelines and recommendations set forth in this manual, you can be certain your filter is applied correctly. Use of chloramines to disinfect water by municipal water treatment plants is very common today. However, the use of chloramines leads to taste and odor issues. Also, the chloramines must be removed from water used in the production of soft drinks and fisheries. Watergroup s Chloramines Removal Filter uses a special catalytically enhanced carbon media which efficiently removes the chloramines from water. Regular granular activated carbon media has less catalytic activity which will only partially remove chloramines from water. Controlled laboratory testing provides evidence of high chloramines removal capacity of the special media used in our products. Watergroup s chloramines removal filter system has been designed to achieve effective and efficient removal of chloramines from water. CAUTION! Do not use where the water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit. 2

4 Specification Unit Item # Model # Tank Size Media (CF) Service Flow Rate (gpm) Backwash Flow Rate (gpm) Shipping Weight (lbs) Chloramines Removal Filter* 4930 CLF20SXT 14 X CLF35SXT 16 X * Recommended flow rates are critical to filter performance Chloramines removal capacity will depend on a variety of factors including influent chloramines concentration, ph and other factors, thus periodic sample testing is required. Working Temperature = F (1-43 C) (Do not subject the unit to freezing temperatures) Working Pressure = PSIG ( kpa) Voltage = 120V / 60 Hz Pipe Size = 3/4 At the stated service flow rates, the pressure drop through these devices will not exceed 15 psig. The manufacturer reserves the right to make product improvements which may deviate from the specifications and descriptions stated herein, without obligation to change previously manufactured products or to note the change. * Do not use water that is microbiologically unsafe without adequate disinfection before or after the system. USA customers will need to add -4 to the item numbers for ordering. Peak flow rates intended for intermittent use only (10 minutes or less) and are for residential applications only. Do not use peak flow rate for commercial applications or for a continuous rate when treated water supplies are geothermal heat pump, swimming pool, etc. For satisfactory operation, the pumping rate of the well system must equal or exceed indicated backwash flow rate. Recommended flow rates are critical to filter performance. Chloramines removal capacity will depend on a variety of factors including influent chloramines concentration, ph and other factors, thus periodic sample testing is required. Water and Time Consumed during regeneration Unit Item # Model # Tank Size Media (CF) Service Flow Rate (gpm) Backwash Flow Rate (gpm) Back- Wash Time (Minutes) Rapid Rinse (Minutes) Total Regeneration Time (Minutes) Water used during Regeneration (gallons) 4930 CLF20SXT 14 X CLF35SXT 16 X

5 How a WaterGroup Automatic Backwashing Filter Works Raw water enters your home through the main supply line, enters your filter, and passes downward through the media bed Chloramines are removed from the water. The filtered water then flows up and into your household water lines. Periodic regeneration is required to flush entrapped material from the system. In normal operation, the Time of Day display will alternate being viewed with the Day Remaining display. As day passes, the day remaining will count down from a maximum value to zero or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate. Example 3 Days Remaining to Regenerate PM Indicator Flow Indicator (Flashing with water flow) 0 Days Treated Water Remaining PM Indicator Flow Indicator (Flashing with water flow) Timer Behavior During Regeneration In regeneration, the control will display a special regeneration display. In this display, the control will show the current regeneration step abbreviation the valve is advancing to or has reached and the time remaining in that step. The step abbreviation displayed will flash until the valve has completed driving into this regeneration step position. Once all regeneration steps have been completed, the valve will return to Service and resume normal operation. Example Less than 6 minutes remaining in Regeneration Step Rapid Rinse Pushing the during a regeneration cycle will immediately advance the valve to the next cycle step position and resume normal step timing. Please see the control valve manual for different regeneration step abbreviations. 5 Regeneration Step Abbreviation 4

6 Familiarize yourself with the unit and components Control Valve Tank Jacket Tank Media Bed Distributor/Riser 5

7 Installation Instructions Contact your local distributor to use WaterGroup laboratory for complete water analysis free of cost and no obligation to you. All government codes and regulations governing the installation of these devices must be observed. If the ground from the electrical panel or breaker box to the water meter or underground copper pipe is tied to the copper water lines and these lines are cut during installation of the Noryl bypass valve and/or poly pipe, an approved grounding strap must be used between the two lines that have been cut in order to maintain continuity. The length of the grounding strap will depend upon the number of units being installed and/or the amount of copper pipe being replaced with plastic pipe. See Figure 1. In all cases where metal pipe was originally used and is later interrupted by poly pipe or the Noryl bypass valve as in Figure 1 or by physical separation as in Figure 2, an approved ground clamp with no less than #6 copper conductor must be used for continuity, to maintain proper metallic pipe bonding. NOTE: Check your local electrical code for the correct clamp. Figure 1a: Taste and Odor Filter (ACF) Typical Installation 1a Electrical Panel Hard Filtered Water Cold Soft Water Hard Soft Water Ground Strap Raw Water To Outdoors Drain Drain Water Meter Chloramines Filter Softener Water Heater 6

8 Figure 2 Unfiltered Water Bypass Loop Cut & Capped Ground Strap Required Because of Break in Continuity Filtered Water Line in Home Preparations 1. Determine the best location for your water filter, bearing in mind the location of your water supply lines, drain line and 120 volt AC electrical outlet. Subjecting the filter to freezing or temperatures above 43 C (110 F) will void the warranty. 2. Media Installation (When Necessary). Models including and higher than 1.5 CF of media are shipped with separate media in pails or boxes. Models lower than 1.5 CF of media come loaded with media and this step can be skipped for new installation. 1 Electrical Panel Raw Water To Outdoors Water Meter Filter Hard Filtered Water Ground Strap Drain Drain Drain Softener Electrical Outlet Cold Soft Water Water Heater Hard Soft Water D CAUTION! The unit should be de-pressurized before installing or replacing media a e e C Plug the Riser Tube The riser (distributor) remains inside the tank seated in the depression at the bottom B b a) Remove the valve from the mineral tank. b) Temporarily plug the open end of the riser tube to ensure that no resin or gravel falls down into the distribution. The riser (distributor) remains inside the tank seated in the depression at the bottom Plug tube with a tape. Remove after media is loaded Fill support bed first (if supplied) The media will not always spill down inside the tank and may need to be swept inside. 7

9 Chloramines Filter Media Bed Catalytic Activated Carbon (Black) Support Bed (when supplied) Fine, Medium and/or Coarse Gravel c. Fill mineral tank one quarter full of water to protect distribution during gravel installation. d. Place the media into the tank in the order indicated above. Slowly and carefully add the gravel support bed and the softener or filtration media leveling each layer as it is placed into the tank. e. Fill support bed (if supplied) first. During the filling process, ensure the distributor tube stays on the bottom of the tank, reasonably centered. Remove the tape from the distributor once media is loaded. Whenever possible, fill the tank outdoors to avoid problems with dust. If filling indoors, a dust mask should be worn. The large funnel (sold separately part # 43000) makes filling the tank easier and neater. (Or an empty 1 gallon or 4 liter container with the bottom cut out makes a good funnel.) f O-ring f f. Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank, tightening securely into tank. Note: Ensure that the internal O-ring in the valve fits securely over the riser tube. Silicone grease (part # 92360) or other food grade lubricant may be applied to the O- ring to ease installation of the riser tube. 8

10 DO NOT use petroleum based lubricants as they will cause swelling of O-ring seals. The filter is now charged with media. g. It is recommended that the softener or filter tank now be completely filled with water (SLOWLY) to soak the resin or filtration media before startup. This will allow the media to absorb water as well as help displace any trapped air. This will reduce the chance of backwashing resin or filter media out of the tank during the initial backwash on startup. 3. Outside faucets used to water lawns and gardens should not supply softened water. A new water line is often required to be connected to supply hard water to the inlet of the water softener and to the outside faucets. Cut the water line between where it enters the house and before any lines that branch off to feed the hot water heater or other fixtures in the house and as near the desired location of the water softener as possible. Install a tee fitting on the feed end of the cut pipe, and an elbow fitting on the other end. Install piping from the tee to the inlet of the water softener and from the elbow to the outlet of the softener. To sever the water lines which branch off to feed any outside faucets, cut the branch lines approximately two inches from the fitting on the main water line. Install an elbow on the end of the pipe nearest the outside faucet and a cap on the end connected to the existing water line. Install piping from the tee installed on the inlet line to the water softener to the elbow installed on the pipe to the outside faucet. Following this procedure will result in all lines in the house, with the exception of the outside faucets, but including the water heater and therefore the hot water lines, being supplied with soft water. 9

11 Installation Steps: 1 1. C lamp Ring The clamp ring connects the control valve to the tank and provide an easy way to disconnect tank during control valve servicing. Make sure that the clamp ring screw is tightened The Clamp Ring should secure the valve with the top of the flange facing up. Please note top on the clamp ring. Timer Controls Extra Cycle Button Outlet Inlet 2 Drain 1/2 2. Familiarize yourself with the location of the inlet, outlet and drain on the control valve. Be very careful not to get the controls wet UP button DOWN button 3. Familiarize yourself with the buttons on the timer control.

12 4 Make sure that the flow meter is connected to the outlet of the valve. Flow meter installation is optional. The flow meter is not supplied with the filter. 4. Attach the bypass valve to the control valve (and yoke if plastic bypass is used). Connect the inlet and outlet of the water softener to the plumbing in the house. The control valve must not be submitted to temperatures above 43 C (110 F). When sweat fittings are used, to avoid damaging the control valve, solder the threaded copper adapters to the copper pipe and then, using Teflon tape, screw the assembly into the bypass valve. Bypass Yoke Do not use pipe thread compound as it may attack the material in the valve body. 5 Hose Barb 5 5. Drain Line Connection: Using teflon tape, screw the 1/2 hose barb into the drain port in the valve. Attach 1/2 drain hose to the hose barb and tighten securely with a hose clamp. Run the drain line to a floor drain or a laundry drain. Complete any necessary plumbing. Connect 1/2 drain hose (not supplied) with a hose clamp here Waste connections or drain outlet shall be designed and constructed to provide for connection to the sanitary waste system through an air-gap of 2 pipe diameters or 1 inch (22 mm) whichever is larger. Never insert drain line directly into a drain, sewer line, or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner. 5 11

13 6 7 outlet intlet 6. Make sure the bypass valve is in the service position. 7. Plug the 24-volt transformer into a 120 VAC 60 Hz outlet. 8 Circuit Board Screen Position Label Brine Cam 8. This valve has two positions: 1) Backwash and 2) Rapid Rinse. When the valve is in the Service position must be pressed and held for 5 seconds before it activates. Press and hold the pic for 5 seconds to advance the valve into the 1 Backwash position. Press once more to advance to the 2 position. The valve position during regeneration and servicing can be checked in the circuit board screen as well the position label on the cam. Cycle Step BW RR SV Abbreviation Backwash Rapid Rinse Service 12

14 Water Conditioner Flow Diagrams Service Position Backwash Position Filtered Water Raw Water Hard Water 10 Filtered Water Raw Water Hard Water Soft Water BW Soft Water To Drain To Drain To Drain to advance the valve to the 1 Backwash po9. Press sition. Slowly turn on the water supply and allow the unit to backwash until the air purges out of the tank and clears the system. Hard Water Soft Water 10. Press once more to advance to the 2 Rapid Rinse position and allow water to run to drain for 2 Minutes. Hard Water Important: The filter should be backwashed for 15 minutes before using this for first time RR Rapid Rinse Position 11. Press to advance the valve back into the service position indicated by the in upper left corner of the display. 10 Hard Water To Drain Raw Water Soft Water Soft Water To Drain Important Note: Automatic water filters are supplied from the factory in the backwash position, ready for start up. Turn on the water supply to the unit. Open the supply line slowly and allow the air to escape from the filter before turning the supply water on all the way. Allow the unit to backwash until all the air and media fines are no longer showing at the drain. This may take up to 15 minutes so you need to unplug the timer until you are ready to To Drain continue. Filtered Water To Drain 12. Set time of the day in the control valve and program the user section of the control. Refer to control valve prohard Water Soft Water gramming section in this manual. NOTE: ALL STATE AND LOCAL GOVERNMENT CODES GOVERNING INSTALLATION OF THESE DEVICES MUST BE OBSERVED. 13

15 Programming Instructions Set Time of Day Press and hold or buttons until display reads TD Adjust the displayed time with or buttons. Press to resume normal operation Queuing a Regeneration 1. Press the button. The service icon will flash to indicate that a regeneration is queued. 2. To cancel a queued regeneration, press the button. Regenerating Immediately Press and hold the button for five seconds. User Programming Mode Options Abbreviation Parameter Description OFF DO Day Override The timer s day override setting This is an option only. Please do not adjust before consulting an authorized dealer. RT Regeneration Time The time of day that the system will regenerate (meter delayed, timeclock, and day-of-week systems) CD Current Day The current day of week User Programming Mode Steps Note: Use and Down button to adjust values for parameters 1. Press the and buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM. 2. Use this display to adjust the Day Override. Adjust OFF this to 12 parameter for softeners. 3. Press the button. Use this display to adjust the Regeneration Time. 4. Press the button. Use this display to set the Current Day of the Week. This option setting is identified by CD in the upper left hand corner of the screen. This option is only available after the Day of the Week control is set to ON in the Master Programming. Refer to the valve manual for details. 5. Press the button to end User Programming Mode. OFF In the second level mode, the control valve has been programmed as per the following main parameters related to regeneration. For more information on master programming manual, read control valve manual part # The valve has been pre-programmed with factory settings as shown in the following chart: Regeneration Cycle Step Programming 1. Backwash 6 minutes 2. Rapid Rinse 5 minutes 14

16 Diagnostic Programming Mode Diagnostic Programming Mode Options Abbreviation Parameter Description FR Flow Rate Displays the current outlet flow rate PF Peak Flow Rate Displays the highest flow rate measured since the last regeneration HR Hours in Service Displays the total hours that the unit has been in service VU Volume Used Displays the total volume of water treated by the unit RC Reserve Capacity Displays the system s reserve capacity calculated from the system capacity, feed water hardness, and safety factor SV Software Version Displays the software version installed on the controller NOTES: Some items may not be shown depending on timer configuration. The timer will exit Diagnostic Mode after 60 seconds if no buttons are pressed. Press the Extra Cycle button to exit Diagnostic Mode at any time. Diagnostic Programming Mode Steps 1. Press the and buttons for five seconds while in service. 2. Use this display to view the current Flow Rate. This option setting is identified by FR in the upper left hand corner of the screen. 3. Press. Use this display to view the Peak Flow Rate since the last regeneration cycle. This option setting is identified by PF in the upper left hand corner of the screen. 4. Press. Use this display to view the Hours in Service since the last regeneration cycle. This option setting is identified by HR in the upper left hand corner of the screen. 5. Press. Use this display to view the Volume Used since the last regeneration cycle. This option setting is identified by VU in the upper left hand corner of the screen. 6. Press. Use this display to view the Reserve Capacity. This option setting is identified by RC in the upper left hand corner of the screen. 7. Press. Use this display to view the Software Version. This option setting is identified by SV in the upper left hand corner of the screen. 8. Press to end Diagnostic Programming Mode. 15

17 Controller Behavior Control Operation During Programming The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will continue to operate normally, monitoring days and keeping all displays up to date. Control programming is stored in memory permanently, eliminating the need for battery back-up power. Time Clock Delayed Control A Time Clock Delayed Control regenerates the system on a timed interval. The control will initiate a regeneration cycle at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day override value. Day of the Week Control This control regenerates the system on a weekly schedule. The schedule is defined in Master Programming by setting each day to either off or on. The control will initiates a regeneration cycle on days that have been set to on at the specified regeneration time. Control Operation During a Power Failure The SXT includes integral power backup. In the event of power failure, the control shifts into a power-saving mode. The control stops monitoring water usage, and the display and motor shut down, but it continues to keep track of the time and day for a minimum of 48 hours. The system configuration settings are stored in a non-volatile memory and are stored indefinitely with or without line power. The Time of Day flashes when there has been a power failure. Press any button to stop the Time of Day from flashing. If power fails while the unit is in regeneration, the control will save the current valve position before it shuts down. When power is restored, the control will resume the regeneration cycle from the point where power failed. Note that if power fails during a regeneration cycle, the valve will remain in it s current position until power is restored. The valve system should include all required safety components to prevent overflows resulting from a power failure during regeneration. The control will not start a new regeneration cycle without line power. If the valve misses a scheduled regeneration due to a power failure, it will queue a regeneration. Once power is restored, the control will initiate a regeneration cycle the next time that the Time of Day equals the programmed regeneration time. Typically, this means that the valve will regenerate one day after it was originally scheduled. If the treated water output is important and power interruptions are expected, the system should be setup with a sufficient reserve capacity to compensate for regeneration delays. 16

18 During Regeneration Automatic Bypass The regeneration cycle lasts approximately 15 minutes, after which treated water service will be restored. During regeneration, untreated water is automatically bypassed for use in the household. Hot water should be used as little as possible during this time to prevent hard water from filling the water heater. IMPORTANT: This is why the automatic regeneration is set for sometime during the night and manual regenerations should be performed when little or no water will be used in the household. New Sounds You may notice new sounds as your water softener operates. The regeneration cycle lasts approximately 2-1/2 hours. During this time, you may hear water running intermittently to the drain. Water Bypass Figure 5A Figure 5B Outlet Inlet Outlet Inlet Manual Bypass (Figure 5A) In case of an emergency such as an overflowing brine tank, you can isolate your water filter from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the ON/OFF knobs in line with the INLET and OUTLET pipes. To isolate the filter, simply rotate the knobs clockwise (as indicated by the word BYPASS and arrow) until they lock. You can use your water related fixtures and appliances as the water supply is bypassing the softener. However, the water you use will be hard. To resume treated service, open the bypass valve by rotating the knobs counterclockwise. Stainless Steel Bypass (Figure 5B) In normal operation the bypass lever is aligned with the inlet/outlet with the pointer on SERVICE. To isolate the softener or filter, rotate lever counter clockwise until it stops and pointer indicates unit is in bypass. You can use your water related fixtures and appliances as the water supply is bypassing the softener and filter. However, the water you use will be hard or untreated. To resume treated water service, open the bypass valve by reversing the rotation of the lever. 17

19 Maintenance Instructions Care of Your Filter To retain the attractive appearance of your new water filter, clean occasionally with a mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject your softener to freezing or to temperatures above 43 C (110 F). Servicing Components. The seals and spacer cartridge should be inspected/cleaned or replaced every year depending on the inlet water quality and water usage. The media should be replenished or replaced depending of inlet water quality and water consumption. Check with your water treatment expert on the media bed change frequency. Below are some guidelines Please refer to the servicing section of this manual for step by step procedure. Not following the above will void all warranty on the control valve. Maintenance of your new water filter requires very little time or effort but it is essential. Regular maintenance will ensure many years of efficient and trouble free operation. Replacing Media Bed Catalytic Activated Carbon Media Bed - under normal operating conditions the effective life of the filter media is approximately one to three years depending on the water quality, after which, taste and odor problems may return. When this happens contact your dealer for a replacement media bed. Servicing 6200 Valve Before Servicing 1. Turn off water supply to conditioner : a. If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line, then close the valves at the conditioner inlet & outlet. b. If the conditioner has an integral bypass valve, put it in the bypass position. c. If there is only a shut-off valve near the conditioner inlet, close it. 2. Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily. Return the control to the In Service position. 3. Unplug Electrical Cord from outlet. 4. Disconnect drain line connection. WARNING! ELECTRICAL SHOCK HAZARD! UNPLUG THE UNIT BEFORE REMOVING THE COVER OR ACCESSING ANY INTERNAL CONTROL PARTS. CAUTION! Disassembly while under pressure can result in flooding. Always follow these steps prior to servicing the valve. 18

20 ZONE LAST SAVED IN SMARTEAM: DATE AND TIME CRITICALITY SYMBOLS PER QPSP LEVEL I LEVEL II LEVEL III THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR WATER TREATMENT. REPRODUCTION, USE DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR WATER TREATMENT ENGINEERING. THIS DOCUMENT AND ANY COPIES SHALL BE RETURNED TO PENTAIR WATER TREATMENT UPON WRITTEN REQUEST. DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm] INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M UNLESS OTHERWISE SPECIFIED: CORNER FILLETS R [ ] TOLERANCES: ANGLES : 1 1 PLACE.X:.015 [0.38] 2 PLACE.XX:.01 [0.3] 3 PLACE.XXX:.005 [0.13] ECN REV. THIRD ANGLE PROJECTION 2 APPROVALS DRAWN CHECKED APPROVED DATE REVISIONS TITLE SIZE DESCRIPTION THE COMPONENT, PART, OR ASSEMBLY DESCRIBED IN THIS DOCUMENT MUST COMPLY WITH THE EU (EUROPEAN UNION) DIRECTIVE: RoHS DIRECTIVE 2002/95/EC, THIS DRAWING MUST BE COMPARED TO THE ERP SYSTEM TO ENSURE CORRECT REVISION LEVEL PRIOR TO USE. DWG NO. DATE Pentair Residential Filtration SCALE 1:1 SOLIDWORKS FORMAT SHEET 4 OF 4 1 APP'D REV _ D C B A 6200 Service Kits Piston and Cartridge Assembly O-Ring 98 O-Ring 97 Blank 100 Blank Dwg # Part # Part Description Cartridge Assembly with Piston Screw, 4-40X3/ O-Ring, O-Ring, Seal and Spacer Cartridge Piston Piston Rod O-Ring 97 D 7 O-Ring Service Kits Drain Line Flow Control Kits Dwg # Part # Part Description Washer, Flow, 1.2 GPM Washer, Flow, 1.50 GPM Washer, Flow, 2.0 GPM Washer, Flow, 2.4 GPM Washer, Flow, 3.0 GPM Washer, Flow, 3.5 GPM Washer, Flow, 4.0 GPM Washer, Flow, 5.0 GPM O-Ring, Adapter, Fitting, DLFC Hose Barb, Straight, DLFC,1/2" Hose Barb, 90 Deg, DLFC,1/2" XX DLFC Assembly, XX GPM For < 7 GPM XX DLFC Assembly, XX GPM For > 7 GPM Retainer, Drain 19

21 6200 Service Kits Flow Meter (Optional) Dwg # Part # Part Description Cable, Meter Clip, Flow Meter Screw, Slot Hex, 8-18 X Meter, Assy,3 /4" Dual Port O-Ring, Flow Straightener Meter Only, Electronic Turbine Service Kits Circuit Board 37 Dwg # Part # Part Description Harness, Power, SXT Cable Meter Circuit Board, SXT Screw

22 6200 Service Kits Other Parts Dwg # Part # Part Description Screw, Stl Hex, 6-20 X 3/ Screw, Hex Washer Cam, Brine Label, Cam Position, Softener Label, Cam Position, Filter Screw, Slot, Hex, 8-18 X Collector, Top, 1" Bracket, Idler Gear Idler Switch, Micro Dwg # Part # Part Description Cover, Black Cover, Cream Screw, Slot Hex, 1/4-20 X 1/ Motor, 24V, 50/60 Hz Backplate, Black Backplate, Cream Bracket, Drive Insulator, Limit Switch Link, Piston Rod Shaft, Drive Washer Screw, Hex, 6-20 X 3/8 21

23 6200 Service Kits Other Parts Continued Dwg # Part # Part Description Shaft, Drive Screw, Hex Washer Head Clamp, Ring Clamp Ring Assembly Bypass Valve Assembly & Yokes (Plastic) Item No. Quantity Part No. Description O-ring, Clip, Mounting Screw, Hex Washer Head, 8-18 x 5/8 4A Yoke, Plastic, 1 NPT Yoke, Plastic, 3/4 NPT 4B Yoke, Brass, 3/4 NPT 13708NP Yoke, 3/4 NPT Nickel Plated Yoke, Brass, 1 NPT 13398NP Yoke, 1 NPT Nickel Plated Yoke, 1 1/4 NPT Yoke, 1 1/4 Sweat 22

24 Timer Replacement Meter Cable Screw Brine Valve Screw Self tapping screw 1. Disconnect the meter cable from the meter. (If flow meter is attached) Brine Cam 2. Open the front cover of the control valve, unscrew the brine cam and push the brine valve in order to remove the cam. Bracket 3. Remove the two screws from the grey brine valve bracket and remove it from the valve back plate. Timer Assembly Piston screw Screw Screw 4. Remove the piston screw from the piston rod. 5. Remove the three screws from the front bracket. The entire timer assembly will disconnect from the valve body. 6. Replace the timer with a new one. Attach the three screws to the front bracket and piston screw to the piston rod. Reinstall the brine valve bracket. Reinstall brine cam. Close the front cover of the control valve. 7. Reconnect meter cable. (If flow meter is attached) 23

25 D C B A BR REVISIONS ZONE ECN REV. DESCRIPTION 3 LAST SAVED IN SMARTEAM: DATE AND TIME CRITICALITY SYMBOLS PER QPSP LEVEL I LEVEL II LEVEL III DATE APP'D THE COMPONENT, PART, OR ASSEMBLY DESCRIBED IN THIS DOCUMENT MUST COMPLY WITH THE EU (EUROPEAN UNION) DIRECTIVE: A RoHS DIRECTIVE 2002/95/EC, THIS DRAWING MUST BE COMPARED TO THE ERP SYSTEM TO ENSURE CORRECT REVISION LEVEL PRIOR TO USE. THIRD ANGLE PROJECTION Pentair Residential Filtration APPROVALS DATE TITLE DRAWN CHECKED SIZE DWG NO. REV D _ APPROVED SCALE 1:1 SOLIDWORKS FORMAT SHEET 4 OF D C B Piston Cartridge Assembly Replacement All 5 O-rings need to be inspected for damages and lubricated THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR WATER TREATMENT. REPRODUCTION, USE DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR WATER TREATMENT ENGINEERING. THIS DOCUMENT AND ANY COPIES SHALL BE RETURNED TO PENTAIR WATER TREATMENT UPON WRITTEN REQUEST. DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm] INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M UNLESS OTHERWISE SPECIFIED: CORNER FILLETS R [ ] TOLERANCES: ANGLES : 1 1 PLACE.X:.015 [0.38] 2 PLACE.XX:.01 [0.3] 3 PLACE.XXX:.005 [0.13] Cartridge Assembly This O-ring goes to the bottom of the cartridge 1. Follow steps 1 to 5 of timer replacement. 2. Use a flat head screw drive on the notch of the valve body as shown to loosen the piston cartridge, pull the cartridge out of the body using pliers. 3. Inspect the inside of the valve to make sure that there is no foreign matter that would interfere with the valve operation. 4. Put food grade silicone grease on the o-rings of the new piston cartridge assembly and install it inside the valve body. 5. Reinstall the timer assembly, brine valve bracket and meter cable. Meter Replacement and Service Meter Cable Outlet Port Meter Assembly Clip Flow Meter should be attached to the outlet side of the valve Screw Flow Straightainer Inside the Outlet Port 1. Disconnect the meter cable from the meter. 2. Remove two screws and clips at bypass valve or yoke. Pull resin tank away from plumbing connections. 3. Pull meter module out from control valve. Lubricate O-rings 4. Apply silicone lubricant to four new o-rings and assemble to four ports on new meter module. 5. Assemble meter to control valve. Note, meter portion of module must be assembled at valve outlet. 6. Push resin tank back to the plumbing connections and engage meter ports with bypass valve or yoke. 7. Attach two clips and screws at bypass valve or yoke. Be sure clip legs are firmly engaged with lugs. 24

26 Servicing and Replacing Drain Line Flow Control (DLFC) DLFC Retainer Flow Washer Housing 1. Disconnect the drain line retainer clip. 2. Remove the DLFC assembly and pull the flow washer out of the DLFC housing with then help of plier. 3. Remove the flow washer from the housing and clean it with water to remove any debris. Replace it with a new washer if necessary. 4. Re-install the DLFC housing and retainer. Flow Washer Hose Barb 25

27 Circuit Board Replacement Screws Meter Cable Power Harness 1. Detach the circuit board from valve front cover by removing two screws. 2. Disconnect the meter cable and power head harness from the circuit board 3. Replace and connect the new circuit board on the front cover. After Servicing 1. Reconnect drain line. 2. Return bypass or inlet valve to normal in service position. Water Pressure will automatically build in the softener. NOTE: Be sure to shut off any bypass line. 3. Check for leaks at all sealed areas. Check Drain seal with the control in the backwash position. 4. Plug electrical cord into outlet. 5. Set Time of Day and cycle the control valve manually to assure proper function. Make sure control valve is returned to the In Service position. 6. Start regeneration cycle manually if water is hard. 26

28 6200 SXT Valve Dimensional Drawings All dimensions are in Inches (mm). 27

29 Parts Breakdown Chloramines Filter Part Number Model Distributor (1) Valve (2) Tank (3) Media Bed (4) 4930 CLF20SXT CLF35SXT Common Components Bypass 28

30 Parts Dimensions E A C B D Dimesions (inches) Model # CLF20SXT CLF35SXT A B C D E

31 Trouble Shooting Guide Error Codes Note: Error codes appear on the In Service display Error Code Probable Cause Recover and Resetting [Err 0] Drive motor is stalled Unplug the unit from the power source [Err 1] Drive motor is running continuously When power is restored to the unit, the Err _ display code clears. If the condition causing the error has not been resolved the Err _ code reappears in the four digit display. Do not attempt to troubleshoot this problem any further. [Err 2] Error Display Example There have been more than 99 days since the last Regeneration. If the Day of the Week mode of regeneration is selected and days since last regeneration exceeds 7 days. [ ]: There have been more than 7 days since the last regeneration. All individual settings (d1, d2, d3, d4, d5, d6, d7) are set to 0. Regeneration must occur for the unit to recover, the display to clear and the valve to function normally. [ ]: To recover from [Err2], the user must initiate a regeneration or set at least one individual day to 1. [Err 3] Control board memory failure. Perform a Master Reset. If the error returns, do not attempt to troubleshoot this problem any further. NOTE: Unit will flash when an error exists. 30

32 Trouble Shooting Guide Problem Cause Correction 1. Filter bleeds chloramines A. Bypass valve is open B. Electrical service to unit has been interrupted C. Defective or stripped media bed D. Quality of water has worsened E. Filter capacity too small F. Filter not backwashing enough G. Excessive water usage - calendar clock models 2. Filter fails to regenerate A. Electrical service to unit has been interrupted B. Timer is defective C. Power failure D. Timer motor does not run A. Close bypass valve B. Assure permanent electrical service (check fuse, plug or switch) C. Replace media D. Have water sample analyzed to determine any change E. Replace with larger unit or add another filter F. Be sure flow control is not clogged or drain line restricted. Be sure water pressure has not dropped and that pump has sufficient capacity G. Increase frequency of regeneration. Make sure there are no leaks in toilets or sinks A. Assure permanent electrical service (check fuse, plug or switch) B. Replace timer C. Reset time of day D. Replace defective motor 3. Filter regenerates every day A. Faulty gear train A. Check the mechanical linkage on the timer control to eliminate possible binding in the gear train 4. Loss of water pressure A. Iron or turbidity build-up in filter B. Filter not regenerating often enough C. Not enough water volume or pressure to backwash properly 5. Loss of media through drain line A. Air in water system B. Backwash rate too fast 6. Drain flows continuously A. Foreign material in control B. Timer motor stopped or jammed A. Clean control and treat bed with Iron Out. Increase frequency of regeneration B. Increase frequency of regeneration C. Correct water supply problem A. Assure that well system has proper air eliminator control. Check for dry well condition B. Check drain flow control for proper flow rates A. Remove piston assembly and inspect bore. Remove foreign material and check control in various regeneration positions B. Replace timer motor 31

33 WaterGroup Guarantee WaterGroup Inc. guarantees that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble free service. Seven Year Complete Parts Guarantee: WaterGroup Inc. will replace any part which fails within 60 months from date of manufacture, as indicated by the serial number provided the failure is due to a defect in material or workmanship. The only exception shall be when proof of purchase or installation is provided and then the warranty period shall be from the date thereof. Ten Year Guarantee on Mineral Tanks and Brine Tanks: WaterGroup Inc. will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails within 120 months, provided that the water conditioner is at all times operated in accordance with specifications and not subject to freezing. General Provisions: WaterGroup Inc. assumes no responsibility for consequential damage, labor or expense incurred as a result of a defect or for failure to meet the terms of these guarantees because of circumstances beyond its control.

34 U.S. Headquarters WaterGroup Companies, Inc. 193 Osborne Road Fridley, MN 55432, USA Toll Free Phone: Canada Headquarters WaterGroup Companies, Inc. 490 Pinebush Road, Unit 1 Cambridge, ON N1T 0A5, Canada Toll Free Phone: Distribution Locations Durham, NC Libertyville, IL Pottstown, PA Rancho Cucamonga, CA Cambridge, ON Calgary, AB Regina, SK Printed in Canada

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

Model 5600SE Downflow

Model 5600SE Downflow Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

Model 5600 & 5600 Econominder

Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

Water Tec of Tucson Water Systems

Water Tec of Tucson Water Systems Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging

More information

Model 5600 & 5600 Econominder

Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet.........................................................................

More information

Metermatic SE Automatic Water Softener. Operation Manual

Metermatic SE Automatic Water Softener. Operation Manual Metermatic SE Automatic Water Softener Operation Manual Page 7 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly

More information

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference. MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL

More information

Water Tec of Tucson Water Systems

Water Tec of Tucson Water Systems Water Tec of Tucson Water Systems Water Softener Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment

More information

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater. MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model

More information

WATER SOFTENER SYSTEMS

WATER SOFTENER SYSTEMS INSTALLATION MANUAL WATER SOFTENER SYSTEMS HousePure Models HP-Soft-2 HP-Soft-4 736-0137 Water, Inc. 1044 East Del Amo Blvd., Carson, CA 90746 www.waterinc.com 310-885-4400 P/N 41482 Rev A 06/04 Table

More information

10/20 COMBINATION UNIT

10/20 COMBINATION UNIT MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic

More information

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 7000SXT Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 TIMER FEATURES...3 TIMER OPERATION...4 MASTER PROGRAMMING MODE CHART...5 MASTER PROGRAMMING

More information

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater. MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model

More information

RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1

RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1 R Water Conditioning Owner s Manual R4039 RXD Water Softener This manual contains information on setting the controller and normal operating maintenance required by the owner. Page 1 UNPACKING INFORMATION

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

Installation Instructions 6028.801

Installation Instructions 6028.801 DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American

More information

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590 OWNER S MANUAL MODEL NOS. 625.348570 625.348590 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Fleck 7000 Softener Installation & Start-Up Guide

Fleck 7000 Softener Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2 Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

Clean Water Made Easy

Clean Water Made Easy Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED

More information

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTANT HOT WATER RECIRCULATING SYSTEM INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Installation Instructions 4662.003

Installation Instructions 4662.003 Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please

More information

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

Pro-OX 7800 Iron Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Pro-OX 7800 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For: 3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)

More information

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved. 8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water

More information

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the

More information

Line to Refrigerator Ice/Water Dispenser

Line to Refrigerator Ice/Water Dispenser Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon

More information

MODEL 300505 INSTALLATION INSTRUCTIONS

MODEL 300505 INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Fiberstars Lighted Laminar Flow Fountain Installation Manual Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation

More information

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION OPERATING INSTRUCTIONS Shortening Filter Model No. 99-A, 102-A, & 107-A Series TABLE OF CONTENTS PAGE Installation... 2 Operating... 3 Cleaning... 5 Parts List... 6 & 7 Troubleshooting... 8 LIMITED WARRANTY

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

Owner s Manual. 5600 / 5600 Econominder

Owner s Manual. 5600 / 5600 Econominder 5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job

More information

Water Specialist 1 Control Valve Series Model: WS1

Water Specialist 1 Control Valve Series Model: WS1 Water Specialist 1 Control Valve Series Model: WS1 Operation and Instruction Manual for OEM Only. Please Note: This operation and instruction manual is for the training of the OEM and for the OEM to use

More information

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual Series 255 Valve / 460i Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Introduction............................... 2 Series 255/460i Demand Control System

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10

ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10 Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14

More information

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures KEY CONCEPTS 1. Identify tools for plumbing 2. Location of shutoff valves for the main and individual fixtures 3. How water is supplied to your home 4. How waste water is removed and treated 5. Common

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

B150 Series Commercial Brewer. Direct Plumb Kit

B150 Series Commercial Brewer. Direct Plumb Kit B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer

More information

GE SmartWater INSTALLATION INSTRUCTIONS. Heavy Duty Water Filtration System GNWH38F SAFETY PRECAUTIONS PROPER INSTALLATION

GE SmartWater INSTALLATION INSTRUCTIONS. Heavy Duty Water Filtration System GNWH38F SAFETY PRECAUTIONS PROPER INSTALLATION GE SmartWater INSTALLATION INSTRUCTIONS Heavy Duty Water Filtration System GNWH8F Check with your state and local public works department for plumbing and sanitation codes. You must follow these guidelines

More information

485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association. Owners Manual 485HE High Efficiency Water Softener Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association. 1. Read all instructions carefully before

More information

Geyser-R Heat pump water heater Installation manual

Geyser-R Heat pump water heater Installation manual Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

7500 Pro-Ox Filter Installation & Start-Up Guide

7500 Pro-Ox Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 7500 Pro-Ox Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your

More information

Installation and Operating Instruction Manual

Installation and Operating Instruction Manual Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General

More information

Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener

Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener Water Tec of Tucson WS1TA Twin Alterna ng Water so ener Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 MAIN COMPONENTS Your water treatment

More information

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November

More information

MAC FAUCETS. Owner s Manual. Models: FA444

MAC FAUCETS. Owner s Manual. Models: FA444 MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect

More information

AMX300 DirectConnect Mixing Valve Kits

AMX300 DirectConnect Mixing Valve Kits AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Autotrol 460i and 460TC Control System

Autotrol 460i and 460TC Control System Autotrol 460i and 460TC Control System Installation and Operation Instructions www.pentairaqua.com Contents 460i Electronic Demand System...2 Special Features 460i...2 California Proposition 65 Warning...2

More information

Electric Water Heater

Electric Water Heater Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL Model 550, 700 and 900 Water Softeners Version 4 WaterBoss 4343 S. Hamilton Road, Groveport, Ohio 43125 Table of Contents QUESTIONS?... 1 GETTING MAXIMUM EFFICIENCY FROM

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

WARNING WARNING TABLE 1.

WARNING WARNING TABLE 1. Clean & Clear Cartridge Filter Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. FILTER INSTALLATION... 1 SECTION II. FILTER

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE RICAMBI FLECK P/N 0 O'ring 560 CD 0 P/N 050 Grommet pass rod 20 2300/230/ 2350 P/N 060 Tube 3/8in (0,92 m) 0 P/N 086 Holding Nut M5 2300 0 P/N 0209-0 Quad Ring 560 CD 0 P/N 028 Microswitch 5 P/N 0220 Screw

More information

PWC-500/1000/1010/1500

PWC-500/1000/1010/1500 SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents Introduction Cooler Set-up Remove Top Cover Remove/Replace Float Remove/Replace Hot Tank Faucet Repair Hot Tank

More information

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000 Multi-Pure Whole House Water Treatment System Installation, Operation and Maintenance Manual Multi-Pure Model TO15000 Warning Please read manual carefully before proceeding with installation. It is recommended

More information

ECONOFLO 5600SXT SOFTENER Model 5600 SXT-User Programming Chart Time of Day. Model 5600 SXT -User Programming Chart

ECONOFLO 5600SXT SOFTENER Model 5600 SXT-User Programming Chart Time of Day. Model 5600 SXT -User Programming Chart FROM SERVICE MODE:- ECONOFLO 5600SXT SOFTENER Model 5600 SXT-User Programming Chart Time of Day To set Time of the Day push and hold or button for 5 seconds DOWN (*Not both Up and Down s) Display is TD

More information

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011 OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A

More information

Installation and Operation Manual

Installation and Operation Manual Model WHED20 How to install, operate and maintain your Undersink Drinking Water Filter System Do not return unit to store If you have any questions or concerns when installing, operating or maintaining

More information

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety

More information

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description

More information

Nexus FS Point of Use Installation Guide

Nexus FS Point of Use Installation Guide Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:

More information

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

What to Expect From the Examination. How to Study the Plumbing Codes

What to Expect From the Examination. How to Study the Plumbing Codes Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INDIRECT WATER HEATER. Installation and Operating Instruction Manual INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing

More information

STABITHERM INSTALLATION & SERVICE BOOKLET

STABITHERM INSTALLATION & SERVICE BOOKLET STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information