ASSE 1016, 1069 & 1070



Similar documents
Pressure Drop Basics & Valve Sizing

Thermostatic Mixing Valves

Code Reference Competitive Comparison

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

Understanding Potential

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS. Second Edition. Prepared by

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

Plumbing Identification and Damage Assessment Guide

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

Installation & Operation Manual Models: STU

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

2012 British Columbia Plumbing Code Update

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

PLUMBING SUBMITTAL

SIZING OF WATER PIPING SYSTEM

Controlling Legionella in Plumbing Systems. Presented by: Julius Ballanco, P.E. President, JB Engineering and Code Consulting, P.C.

Custom Shower Design Guide

What to Expect From the Examination. How to Study the Plumbing Codes

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

:2009 HELLENIC CHNICAL SPECIFICATION ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common ICS: 93.

Bath Planning Guidelines With Access Standards

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

ESTIMATING PLUMBING, HEATING, VENTILATING, AND AIR CONDITIONING (HVAC), AND ELECTRICAL WORK

CHAPTER 2: The Plumbing System

PLUMBING. For HOME OWNERS

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

SHOWERS SHOWERS

Water Heater Sizing TS Saturday 2:15pm 5:15pm J. Joe Scott CPD, FASPE, LEED

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

NAVIEN AMERICA INC FITCH AVENUE

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Trin & Stor Model Numbers: ST Series Version Date:

INSTALLATION GUIDE AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Continuous Flow Water Heaters

PROPOSED Plumbing Fee Ordinance Amendment

Plumbing Lesson One: Help! Call the Plumber. Student Handouts

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

FIXTURES, FAUCETS AND FIXTURE FITTINGS

Georgia State Amendments to the International Plumbing Code

Indirect-fired Steam & Boiler Water Heaters

Tempra / DHC-E. Simply the Best The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Master Advice From The Shower Experts

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

BI-TECH TIMON CROSS TINY CROSS PIPE PI TOWER TO TECH-PROGRAM LAVABO - BIDET WASH BASIN - BIDET

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Proposed Revision to International Residential Code 2012 (as proposed to the ICC for IRC 2015)

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

H 2 HOT WATER STORAGE/ BOOSTER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS O30ST O40ST O60ST O60LST O80ST O80STC O115ST O115STC

High kw Electric Tankless Water Heater Troubleshooting Guide

Environmental Services Department

CITY OF AUSTIN Uniform Plumbing Code. Changes

AMX300 DirectConnect Mixing Valve Kits

Isometric Plumbing Drawings

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Aquamax Australia Pty Ltd ABN

FIXTURES, FAUCETS AND FIXTURE FITTINGS

GOLD Plus 30/40/60/80

Endless Hot Water. The Perfect Solution for Residential and Commercial Water Heating

Utility Service Application

NQTMVS GENERAL INFORMATION. heading text INSTALLATION SERVICE PAGE 1» SECTION MARKER SUB-HEADING. Body Text

Neuton Solar Power Diverter Quick Installation Guide

Installation & Operation Manual Models: SIT030 - SIT119

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Does Wall Township require an inspection by the building department on resale of a home?

ECOSMART TROUBLE SHOOTING GUIDE MODELS ECO18-ECO27

GROHE Bathroom NEW GROHE EUROSMART FOR BATHROOM, KITCHEN AND COMMERCIAL MASTERS OF TECHNOLOGY

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Endless Hot Water 24/7

SECTION K - HOT WATER SUPPLY REQUIREMENTS

WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT

REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

Apprenticeship Curriculum Standard. Plumber. Level 2. Trade Code: 306A

2012 B.C. Plumbing Code

Session 2: Hot Water Supply

Schedule of Maintenance Fees

The ADL Spa. from Best Bath Systems. Providing superior safety, comfort and durability in bath design

Hot Water Plumbing Systems

Safe Bathing, Hot Water and Surface Temperature Policy

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

WATER HEATERS. If your water heater tank is leaking, then your course is clear: buy a new unit. But if it isn t, your answer is less obvious.

FIRE SPRINKLERS IN TOWNHOMES/CONDOMINIUMS

This presentation premiered at WaterSmart Innovations. watersmartinnovations.com

Transcription:

ASSE 1016, 1069 & 1070

ASSE 1016-2005 Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations Intended for wall-mounted showers and tub/showers Bather or bather s attendant has access to flow and final temperature control No further mixing downstream from this device

ASSE 1016-1996 Previous Revision ASSE 1016-1996 Became a catchall for new products and applications (lavatories, whirlpools, baths, gang showers) 2005 rev. more clearly defined as wallmounted showers & bath/showers only New standards introduced for new applications (ASSE 1069 and 1070)

ASSE 1016-2005 ASSE 1016-2005 vs. 1996 Scope: 2005 Shower and Tub/Showers 1996 Individual Fixture Fittings Temperature variation test change from +3 o F(1996) to +3.6 o F (2005) across all valve types 2005 defines the user as the bather and bather s attendant, 1996 defines bather only

ASSE 1016-2005 ASSE 1016-2005 defines three (3) types of tempering valves Type P or pressure balancing Type T or thermostatic Type T/P or Combination thermostatic/pressure balancing

ASSE 1016-2005 Pressure Balancing - Type P Increase/decrease hot and cold water supply pressures by 50% Must hold +3.6 o F/2.0 o C within 1 second No temperature compensation requirement Minimum flow 2.5 gpm Cold water failure < 0.5 gpm

ASSE 1016-2005 Thermostatic - Type T Increase/decrease hot and cold water supply pressures by 20% Increase hot water supply temperature 25 o F (5 o F per minute) Must hold +3.6 o F/2.0 o C within 5 seconds Minimum flow 2.5 gpm Cold water failure < 0.5 gpm

ASSE 1016-2005 Combination - Type T/P Increase/decrease hot and cold water supply pressures by 50% Increase hot water supply temperature 25 o F (5 o F per minute) Must hold +3.6 o F/2.0 o C within 1 second Minimum flow tested = 2.5 gpm Cold water failure < 0.5 gpm

ASSE 1070 & IPC IPC - 2006 Section 416.5 Tempered water for public hand washing facilities Tempered water shall be delivered from public hand-washing facilities through an approved water temperature-limiting device that conforms to ASSE 1070

ASSE 1070 & IPC IPC - 2006 Section 424.5 Bathtub and whirlpool bathtub valves The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120 o F (49 o C) by a water temperature limiting device that conforms to ASSE 1070

ASSE 1070 & IPC IPC - 2006 Section 408.3 Bidet water temperature The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110 o F (43 o C) by a water temperature limiting device conforming to ASSE 1070

ASSE 1070-2004 Water Temperature Limiting Devices Tempers the hot side of valve to limit maximum outlet temperature, when mixed with cold water Sinks, lavatories and whirlpools/tubs May or may not be final tempering device

ASSE 1070-2004 Water Temperature Limiting Devices Final temperature is user adjustable Minimize scalding risk but not thermal shock Single or multiple fixtures Must prevent cross flow

ASSE 1070-2004 Performance Requirements 20% pressure changes to hot and cold water supplies, 25 o F hot water increase (5 o F per minute) Maintain +7 o F Minimum flow Manufacturers stated Cold water failure: 0.2 gpm or 20% of minimum stated, whichever is greater

ASSE 1069 & IPC IPC - 2006 Section 424.4 Multiple (gang) showers Multiple (gang) showers supplied with a single-tempered water supply pipe shall have the water supply for the showers controlled by an approved automatic temperature control mixing valve that conforms to ASSE 1069

ASSE 1069-2005 Automatic Temperature Control Mixing Valves Devices that service end-use fittings, including but not limited to gang showers and sitz baths Supply tempered water, at a pre-set temperature, through a single-pipe supply For metering or on/off showers

ASSE 1069-2005 Automatic Temperature Control Mixing Valves Covers single and multiple fixtures Bather cannot adjust final temperature, only installer or facility owner Maximum allowable temperature 120 o F w/mechanical limit stop Final tempering device

ASSE 1069-2005 Performance Requirements 20% pressure changes to hot and cold water supplies, 25 o F hot water increase (5 o F per minute) Maintain +3.6 o F after five seconds Minimum flow: lesser of 2.5 gpm or manufacturer s stated minimum Cold water failure: 0.5 gpm < ¾, 1.0 gpm > 1

ASSE 1016 vs. ASSE 1069 for individual showers with hot and cold water supply 1016 (mixing) for preset water temperature and single-pipe supply 1069 (on/off) 1016 includes three valve types (T/P, T, P) specifies one valve type, thermostatic, similar to type 1069 (T)

ASSE 1016 vs. ASSE 1069 valves can be adjusted by the bather for temperature 1016 and volume valves can only be adjusted by installer or facility owner 1069 1016 valves are tested at a minimum of 2.5 gpm valves are tested at the lesser of 2.5 gpm or the 1069 manufacturers stated minimum flow

ASSE 1016 vs. ASSE 1070 for individual showers with hot and cold water 1016 supply (mixing) and is the final tempering device for lavatories and tubs, tempering or limiting the 1070 hot-water supply side temp. of a valve and may or may not be the final tempering device 1016 includes three valve types (T/P, T, P) specifies one valve type, thermostatic, similar to 1070 type (T)

ASSE 1016 vs. ASSE 1070 requires temperature control of +3.6 o F and 1016 is intended to minimize the risks of scalding and thermal shock requires temperature control of +7.0 o F and 1070 is not intended to prevent thermal shock 1016 minimum flow tested is 2.5 gpm tests to mfgrs. minimum stated flow, 1070 typically 0.5 gpm

ASSE 1069 vs. ASSE 1070 1069 provides preset water temperature to singlepipe supply (on/off) fittings like metering showers, and is the final tempering device for lavatories and tubs, tempering or limiting 1070 the hot-water supply side temp. of a valve and may or may not be the final tempering device

ASSE 1069 vs. ASSE 1070 does not allow user adjustment of flow and 1069 temperature, installer or building owner sets temperature 1070 does allow for user adjustment 1069 requires temperature control of +3.6 o F requires control of +7.0 o F, hand washing and 1070 tub fills

Side by Side Criteria ASSE 1016 ASSE 1069 ASSE 1070 Application Shower & Bath/Shower Gang Showers/Sitz Baths Lavatory/Whirlpools Supply Mix Single Temp. Supply Mix Valve Types T, P, T/P T T Final Tempering Yes Yes Either Fittings Individual Indiv. or Multi Indiv. or Multi Temp Range Full cold to 105, max 120 110-115F Must incl. 105-110F Control +3.6 o F +3.6 0 F + 7 o F Min. Flow 2.5 gpm 2.5 gpm or mfg min. Manf. Stated min. CWF 0.5 gpm 0.5 gpm for 1/2", 1 gpm for 3/4" 0.2 gpm or 20% of min. flow