Master Advice From The Shower Experts

Size: px
Start display at page:

Download "Master Advice From The Shower Experts"

Transcription

1 Master dvice From The Shower Experts Creating a shower system will be made easier and more enjoyable with thorough planning prior to installation. y exploring all the options first, you can have a pleasant experience in the design and specification of your system as well as in using it! What elements do I need to create a shower system? Wall Outlet odyspray Thermostatic Valve Trio -Way Diverter Trio -Way Diverter w/shut-off Quattro 3-Way Diverter You may have some questions before planning your shower system: What do I want from my shower? Relaxation, invigoration? More than one user at a time? Where can I put a shower system? How much space will I need? How much do I want to spend? How much will I need to spend? What are the parts and components that I will need? How will all the valves and controls work together? What about the water supply, drainage and other practical considerations? Have I considered all possible users? Children, elderly users? re there any special requirements, like access for the mobility challenged? What should I take into account when designing my shower system? udget: Space: Enclosures: Water Volume: Water Flow: Water Heater: Floor Drain: Local Codes: Time: Determine a budget for creating your shower system. Showers can range in size from about 30" x 30" to any customized dimension. Enclosures contain splashing and create a more private space, but they are not a necessity when designing a shower system. n open plan can offer many possibilities. Determine the water volume you to have for your custom shower. The Flow Rate Work Sheet will help you with this. We recommend PSI for a shower system to operate properly. Your plumber or contractor can help you determine your average incoming water pressure. It is important to ensure sufficient hot water supply. Here again, the Flow Rate Work Sheet will help you estimate the throughput of a system. Install a drain (or multiple drains) that can handle twice the amount of water as all components combined provide. Local plumbing codes vary greatly from state to state. e sure to understand and follow them. Installation time may also be a factor, especially on do-it-yourself jobs. For peace of mind and efficiency, we recommend that shower systems be installed by a licensed plumber

2 Valve Configuration Volume Control " and 3 4" volume control valves are used as stop valves and to regulate the amount of water to one or more outlets. Controls One Function Controls Multiple Functions Controls showerhead C Controls showerhead Controls left bodysprays Controls right bodysprays C Fix Fit Wall Outlet Controls One Function The " Fix Fit Wall Outlet combines the benefits of a volume control and a wall outlet. Fix Fit Wall Outlet can be mounted near a shower bench or across from the main valving, eliminating the need to install an additional valve and a separate wall outlet. Controls handshower 0.8

3 Valve Configuration Trio -Way Diverter w/shut-off Trio -Way Diverter w/shut-off The 3 4" Trio -Way Diverter can be used as a stop valve and flow control for shower systems with two outlets. volume control is not required when using this configuration. With the Trio -Way Diverter you can choose between a single function or two functions at once. Controls showerhead and h andshower or a combination of both Quattro 3-Way Diverter Quattro 3-Way Diverter The 3 4" Quattro 3-Way Diverter can divert water flow to one of three outlets or any combination of two outlets. It serves only to change the water s direction. single volume control must be installed in conjunction with this valve. Diverts the water to bodysprays, handshower, showerhead or any combination of two The volume control regulates the volume of water

4 Flow Work Sheet Product Water Flow in GPM (Gallons per Minute) Showerhead.5 Handshower.5 odyspray.6 Using the values below, you can calculate the maximum flow rate of your system. Product Quantity X GPM = Total GPM Showerhead x.5 = Handshower x.5 = odyspray x.6 = Other outlets x = The valve s mixed water output should be equal to or greater than: GPM. Product Water PSI xor Thermostatic Trim 6 GPM 8 GPM xor Pressure alance Trim 6.5 GPM 7.5 GPM oth Trims above require the iox Universal Plus Rough w/service Stops, 3 4". This value cannot exceed the capacity of your incoming water supply! You also must use this value as a guide in determining the capacity of the water heater(s) and drain(s). Valves lmost all valves installed in the US are concealed valves. This valve type consists of two parts the rough (the valve itself, which goes behind the wall) and the trim (the decorative plate and handle). This section describes the different types of roughs available. Matching trims are available for all valves. There are three functions that shower valves must perform:. Control the water temperature and maximum mixed water output.. Control the water volume to an outlet or diverter. C. Control the direction of flow when multiple outlets are used. xor Thermostatic Mixing Valve: Maintains water temperature to within +/- F while delivering up to 6 44 PSI. *Note: This valve type requires the use of a separate volume control. Trio -Way Diverter : Controls water direction to outlets. Can be used with both outlets simultaneously. * Note: This valve type requires the use of a separate volume control., Pressure alance Valve: Prevents scalding by compensating for fluctuations in pressure. Integrated On/Off, maximum mixed water output PSI.,C Trio -Way Diverter w/shut-off: Controls water direction and volume to outlets. Can be used with both outlets simultaneously. No separate volume control needed. Volume Control: Turns the water on and off and regulates volume. Fix Fit: Volume control and wall outlet combined into one. C Quattro 3-Way Diverter: Controls the direction of water flow for three outlets. ny of the 3 outlets can be used simultaneously. * Note: This valve type requires the use of a separate volume control

5 Shower Installation Examples 3 4 Thermostatic plus Two Volume Controls. iox Universal Plus Rough with Service Stops, 3 4" # xor Massaud Thermostatic Trim #87400 Thermostatic temperature control Functions 3. (x) Rough, Volume Control #59748 or # (x) xor Massaud Volume Control Trim # Thermostatic plus Trio Diverter with Shut-Off. iox Universal Plus Rough with Service Stops, 3 4" # xor Montreux Thermostatic Trim with Cross Handle #686xx Thermostatic temperature control Functions 3. Rough, Trio -Way Diverter with Shut-Off, ¾" #5988 Selects between showerhead and handshower or a combination of both, plus shuts off water 4. xor Montreux Trio/Quattro Trim with Cross Handle #6833xx

6 Shower Installation Examples Thermostatic plus Trio Diverter with Shut-Off and Fix Fit Wall Outlet. iox Universal Plus Rough with Service Stops, 3 4" # xor Citterio Thermostatic Trim with Lever Handle #397xx Thermostatic temperature control 3. Rough, Trio -Way Diverter with Shut-Off, 3 4" #5988 Selects between showerhead, bodysprays or a combination of both, plus shuts off water 3 Functions 4. xor Citterio Trio/Quattro Trim with Lever Handle #3993xx 5. xor Citterio Fix Fit Wall Outlet with Lever Handle #3988xx Controls volume for handshower and shuts off water Pressure alance Function. iox Universal Plus Rough with Service Stops, 3 4" # xor Starck Pressure alance Trim #0407xx Temperature control and volume control 0.

7 Three Ways to Install the Same Shower System Option : Separate Volume Controls Thermostatic Trim 3 Volume Control Trims Hose Wall Outlet Showerarm 3 odysprays Roughs needed: iox Universal Plus Rough #08508 Roughs, Volume Control #59778 Option : Trio Diverter nd Fix Fit Wall Outlet Thermostatic Trim Trio/Quattro Diverter Trim Fix Fit Wall Outlet Hose Showerarm 3 odysprays Roughs needed: iox Universal Plus Rough #08508 Rough, Trio -Way Diverter w/shut-off, 3 4" #5988 Option 3: Quattro Diverter Thermostatic trim Volume Control Trim Trio/Quattro Diverter trim Hose Wall Outlet Showerarm 3 odysprays Roughs needed: iox Universal Plus Rough #08508 Rough, Volume Control #59778 Rough, Quattro 3-Way Diverter, 3 4" #

Custom Shower Design Guide

Custom Shower Design Guide Custom Shower Design Guide Our shower systems are designed to fit a variety of configurations. Most importantly, yours. When it comes to jetted and custom showers, Delta Faucet Company is committed to

More information

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety

More information

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

15430 SAFETY SHOWERS AND EYEWASHES

15430 SAFETY SHOWERS AND EYEWASHES 15430 SAFETY SHOWERS AND EYEWASHES PART 1: GENERAL 1.01 RELATED SECTIONS 01005 - ENVIRONMENTAL HEALTH 11600 LABORATORY EQUIPMENT 15020 - LABORATORIES 15130 - PIPING SPECIALITES 15400 - PLUMBING 15420 -

More information

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations.

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations. APPLICATION: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every lab or room, where an MSDS for the materials used specifies

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Vertical Spray Bidet Fitting Rough 1322X181 Citterio 39224xx0 Citterio 39225xx0 Starck 10220xx0 Steel 35220800 Uno 38220xx0 Terrano 37224xx0 Terrano 37225xx0 Carlton

More information

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL MODELS: AH27, AH24, AH21, AH18, AH16, AH14, & AH 11 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Uno 38475XX1 38379XX1 Steel 35375801 35379801 Massaud 18743001 18747001 Starck X 10385XX1 10386XX1 Starck 10375XX1 10379XX1 Citterio M 34715XX1 34716XX1 Citterio 39384XX1

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Axor Citterio 39384XX1 39387XX1 Axor Citterio 39385XX1 39386X1 Axor Massaud 18743001 18747001 Axor Starck X 10385XX1 10386XX1 Axor Starck 10375XX1 10379XX1 Axor Terrano

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A Do-It-Yourself Home Water Audit

A Do-It-Yourself Home Water Audit A Do-It-Yourself Home Water Audit This page is left blank intentionally. Please use the double-sided printer setting when printing. Your new Home Water Savings Kit can help you conduct a do-it-yourself

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION http://waterheatertimer.org/how-to-install-under-counter-water-heater.html INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: ECO 16 18 21 24 27 IMPORTANT SAFETY INFORMATION As when installing or using

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST 1. Working plans shall be drawn to an indicated scale, on sheets of uniform size, with a plan of each floor, and shall show those items from the following

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

INSTALLATION INSTRUCTIONS BL-8704

INSTALLATION INSTRUCTIONS BL-8704 INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

112039.00 224500 EMERGENCY PLUMBING FIXTURES

112039.00 224500 EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following emergency plumbing fixtures: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Hand-held drench hoses. 5. Combination

More information

Hansgrohe Technical information. Planning and installation. Overhead showers and shower systems

Hansgrohe Technical information. Planning and installation. Overhead showers and shower systems Hansgrohe Technical information Planning and installation Overhead showers and shower systems Table of contents Content 4 10 14 18 34 46 48 52 Hansgrohe for Professionals System 1: 1-spray showers Like

More information

INSTALLATION INSTRUCTIONS MK-8704

INSTALLATION INSTRUCTIONS MK-8704 INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1

More information

B. Shop Drawings: Diagram power, signal, and control wiring.

B. Shop Drawings: Diagram power, signal, and control wiring. SECTION 224500 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Combination units. 5. Water-tempering equipment. 1.2 SUBMITTALS

More information

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Your Questions Answered Common applications Benefits of performance How to select, size and install Efficient water heating

More information

Axor ShowerCollection with Philippe Starck Information & inspiration for professionals

Axor ShowerCollection with Philippe Starck Information & inspiration for professionals Axor ShowerCollection with Philippe Starck Information & inspiration for professionals ConTenTS 04 The principle 10 The planning examples 35 The installations 43 The product overview 50 The references

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Electric Tankless Water Heater

Electric Tankless Water Heater Electric Tankless Water Heater INSTRUCTION & OPERATION MANUAL TANKLESS WATER HEATERMODELS x AHS5D x AHS21D x AHS7D x AHS24D x AHS9D x AHS27D x AHS11D x AHS14D x AHS16D x AHS18D TECHNICAL ASSISTANCE PLEASE

More information

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007 ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007 The following are general requirements pertaining to plumbing in one and two family dwellings. This does not represent all the provisions regulating plumbing

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

Plumbing Identification and Damage Assessment Guide

Plumbing Identification and Damage Assessment Guide Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INDIRECT WATER HEATER. Installation and Operating Instruction Manual INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing

More information

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting [email protected] H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,

More information

Electric Water Heater

Electric Water Heater Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.

More information

Home comfort: water heating

Home comfort: water heating Home comfort: water heating Water heating usage Hot water. It s one of those luxuries we give little thought to until we run out. This information is provided to help you get the most value and comfort

More information

Introducing. The Flood Free Zone. The Only Sensible Way To Prevent And Control Household Water Leaks

Introducing. The Flood Free Zone. The Only Sensible Way To Prevent And Control Household Water Leaks Introducing The Flood Free Zone The Only Sensible Way To Prevent And Control Household Water Leaks Water absolutely essential for living devastating to the interior of a home when its out of control! The

More information

FIRING RANGE PHASE 1 DESIGN 224500-1

FIRING RANGE PHASE 1 DESIGN 224500-1 FIRING RANGE PHASE 1 DESIGN 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Approved courses for licences and licence endorsements detailed in the Plumbing and Drainage Regulation 2003 (Qld) Licences

Approved courses for licences and licence endorsements detailed in the Plumbing and Drainage Regulation 2003 (Qld) Licences Licence Type Qualification Required Practical Experience Other Information Drainer Provisional drainer qualification plus six (a) At least one year s practical draining competencies from CPC40912 Certificate

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 22 45 00 - (ADD#2) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.

8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved. 8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and

More information

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES The following are suggestions to help you winterize your home plumbing. They are for homes where the heat is not left on during the winter months. There

More information

Installation Guide. Product Code: CNECHO. www.spaequip.com T: 707-737-1100 F: 707-737-1150 Page 1 of 9. ITEM: Echo Footspa from Continuum Footspas

Installation Guide. Product Code: CNECHO. www.spaequip.com T: 707-737-1100 F: 707-737-1150 Page 1 of 9. ITEM: Echo Footspa from Continuum Footspas Installation Guide PRODUCT #: CNECHO ITEM: Echo Footspa from Continuum Footspas BRAND: Continuum Footspas SOURCE FOR PURCHASE: SpaEquip Inc. 211 Wappo Ave Calistoga, CA 94515 USA (707) 737-1100 www.spaequip.com

More information

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Safety First! How to Specify Emergency Showers and Eyewashes Presented by Mike Adkins, Guardian Equipment. ASPE

More information

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING WARRANTY 1 PACKING LIST DESCRIPTION MODEL NUMBER - PANEL HOUSING 88062

More information

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the

More information

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet Providing Temperature Regulated Warm Water to your Sanicare Hand Spray Bidet The Sanicare Thermostatically Controlled Mixer Valve allows you to precisely control the temperature of the warm water for your

More information

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS PART 9 - HOT WATER SUPPLY REQUIREMENTS The hot water supply shall be sufficient to satisfy the continuous and peak hot

More information

What to Expect From the Examination. How to Study the Plumbing Codes

What to Expect From the Examination. How to Study the Plumbing Codes Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.

More information

INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA

INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA An effective new approach to isolate plumbing stub-outs in residential construction Jeffrey P. Kwolkoski, P.E., INCE Bd. Cert. a D. L. Adams Associates,

More information

22 12 00 FACILITY POTABLE WATER STORAGE TANKS

22 12 00 FACILITY POTABLE WATER STORAGE TANKS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 50 foot

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

NQTMVS GENERAL INFORMATION. heading text INSTALLATION SERVICE PAGE 1» SECTION MARKER SUB-HEADING. Body Text

NQTMVS GENERAL INFORMATION. heading text INSTALLATION SERVICE PAGE 1» SECTION MARKER SUB-HEADING. Body Text NQTMVS INSTALLATION SERVICE heading text SUB-HEADING Body Text PAGE 1» SECTION MARKER GENERAL INFORMATION table of contents The Company Device Testing & Certification» Thermostatic Mixing Valves» Backflow

More information

AMX300 DirectConnect Mixing Valve Kits

AMX300 DirectConnect Mixing Valve Kits AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates

More information

To Repair or Replace?

To Repair or Replace? U- Fix It Workshop To Repair or Replace? How old are the fixtures you are repairing? Will cost or risk of repair outweigh the cost of replacing the fixture/appliance? New water saving fixtures may be best

More information

How to Protect Your Property Against Plumbing Disasters

How to Protect Your Property Against Plumbing Disasters How to Protect Your Property Against Plumbing Disasters Over 15 Years of Experience Servicing Toronto & GTA Available 24-Hours a Day CONTENT Why Your Home Plumbing Matters...2 Plumbing 101...3 Caring For

More information

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.

More information

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES CW-4622 RISER KIT WITH WHITE LEVER DIVERTER TO SUIT EXPOSED VALVES & BATH/SHOWER VALVES CB-4622 CW-4622

More information

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS ADVANTAGE PLUS SITE REQUIREMENTS SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS 50096-927 Rev A For additional information contact your Medivators Pg 1 of 18 SITE REQUIREMENTS The purpose of this section

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

Georgia State Amendments to the International Plumbing Code

Georgia State Amendments to the International Plumbing Code Georgia State Amendments to the International Plumbing Code (2006 Edition) Georgia Department of Community Affairs Local Government Assistance Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT

WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT WATER HEATER SIZING GUIDELINES FOR INITIAL INSTALLATION & REPLACEMENT COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH PLAN CHECK AND CONSTRUCTION 5500 OVERLAND AVE. SAN DIEGO, CA 92123 P.O. BOX

More information

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS FOR MODELS EPJ-40 AND EPJ-56 SEE REAR COVER FOR INDEX Read this instruction manual before installation, operation, or service. Failure

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

What is Thermal Expansion?

What is Thermal Expansion? What is Thermal Expansion? When water is heated it expands. For example, water heated from 90ºF to a thermostat setting of 140ºF in a 40 gallon hot water heater will expand by almost one-half gallon. This

More information

RECON WATER HEATER INSTALLATION FORM

RECON WATER HEATER INSTALLATION FORM RECON WATER HEATER INSTALLATION FORM Please complete ONE (1) form for each SITE and return to AERCO for warranty validation within 30 days of start-up. After completion, e-mail this form to: [email protected].

More information

Builder Specifications for Solar Ready Homes

Builder Specifications for Solar Ready Homes Builder Specifications for Solar Ready Homes This document specifies the essential elements required to make a new home ready for the future installation of roof-mounted solar domestic hot water and photovoltaic

More information

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric

More information

Commercial Electric Water Heater

Commercial Electric Water Heater Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust

More information

The Flow Pro" Whedon Shower Heads, Hand Showers & Accessories

The Flow Pro Whedon Shower Heads, Hand Showers & Accessories Better Quality Showers & Faucet Attachments Whedon Products, Inc. The Flow Pro" We Make Less Water Feel Like More! Retail Packaged Shower Program Whedon Shower Heads, Hand Showers & Accessories When Getting

More information

Inspecton Report. Property Address:

Inspecton Report. Property Address: Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 [email protected] www.nationalhomeservices.com Property Address: 873

More information

ASSE 1016, 1069 & 1070

ASSE 1016, 1069 & 1070 ASSE 1016, 1069 & 1070 ASSE 1016-2005 Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations Intended for wall-mounted showers and tub/showers Bather or bather s attendant has

More information

PRIVATE WELL SEPARATION

PRIVATE WELL SEPARATION PRIVATE WELL SEPARATION This is an explanation to explain what you have to do with your well, and/or the other sources of water that you may have, in order to receive public water. The term well includes

More information

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class

More information

GENERAL PLUMBING REQUIREMENTS

GENERAL PLUMBING REQUIREMENTS 22 00 00 GENERAL PLUMBING REQUIRMENTS i. 01 81 00 Facility Performance Requirements ii. 22 07 00 Plumbing Insulation iii. 22 10 00 Plumbing Piping iv. 22 40 00 Plumbing Fixtures v. 22 45 00 Emergency Plumbing

More information

Heat Pump Water Heater IOM Manual

Heat Pump Water Heater IOM Manual Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report Atlanta Strip Mall Commercial Building Property Address: Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of

More information

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information

SF15K SF05KSS, SF10KSS

SF15K SF05KSS, SF10KSS Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Cost Estimation for Materials and Installation of Hot Water Piping Insulation Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated

More information

Spouts and Flow Regulators

Spouts and Flow Regulators Spouts and Flow Regulators Durable, chrome plated brass spouts A wide selection of flow regulators Chicago Faucets Spouts and Flow Regulators Chicago Faucets offers one of the widest selection of spouts

More information

Tepid Water Solutions for you and your customers

Tepid Water Solutions for you and your customers www.tepid.com Tepid Water Solutions for you and your customers Thank you for your interest in the Stingray product line. This brochure is a representation of our capabilities, and we encourage you to contact

More information

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle

More information

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet Providing Temperature Regulated Warm Water to your Sanicare Hand Spray Bidet The Sanicare Thermostatically Controlled Mixer Valve allows you to precisely control the temperature of the warm water for your

More information

MAC FAUCETS. Owner s Manual. Models: FA444

MAC FAUCETS. Owner s Manual. Models: FA444 MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect

More information

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+

Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+ Electric Mini Tank Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information