SPP Pumps Inc. Atlanta



Similar documents
FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

FAIRBANKS NIJHUIS FIRE PUMPS.

Fire Pump Plan Review March 2010

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

TECHNICAL ADVISORY BULLETIN

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

Fire Protection Pumps

TECHNICAL INFORMATION Bulletin

Pressure Limiting Driver (PLD)

FIRE FIGHTING PACKAGES

VERTICAL TURBINE AND PROPELLER PUMPS

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

CHAPTER. Fire Pumps FIRE PUMP OVERVIEW. Fire Pump Unit Defined. Fire Pump Unit Responsibility

World-Class Fire Suppression Pumping Solutions

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Vertical Pumps for the Oil & Gas Industry

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

Model 1210C Battery Powered Pump Shown. Description

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

The Jockey Pump, an Important Part of a Fire Pump System.

SECTION DIESEL-DRIVEN, FIRE PUMPS

Design & Construction Standards, Revised January

KIRLOSKAR FIRE FIGHTING PUMPS AND PACKAGES

Diesel Engine Driven Generators Page 1 of 6

Horizontal Jet Pumps 1/3-1-1/2 HP

Medical Air Systems: Scroll

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Axial and Mixed Flow Pumps for Large Volume Pumping

The conditions below apply to the curves shown on the following pages.

Midwest Industrial Tanks

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Magnum Mobile Generator MMG55 Specifications

Industrial Electric Monitors. Industrial

DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.

KODAK VERSAMARK, INC.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

4" SUBMERSIBLE PUMPS

HYDROSTATIC TEST PUMPS

C18 ACERT Fire Pump Tier bkw/ rpm

Goulds Water Technology

Inspection and Testing of Water-Based Systems

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

300 Series PA Pump and Cooler Assemblies

NFPA 20 Update 2013 Edition. Revision Cycle. NFPA 20 Update /1/2013. Goals and Objectives

301.7D. Mini Hydraulic Excavator

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

The Yachtmans Choice...

Pumping Fuel & Fuel Oil

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Section 8 Storage Tanks & Equipment

Pump Maintenance - Repair

ACCUMULATOR INSTALLATION

OREGON FIRE CODE Interpretations and Technical Advisories

FILLING AND PURGING THE SYSTEM

HORIZONTAL PUMPING SYSTEM

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Excellence through Versatility

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

TECHNICAL INFORMATION Bulletin

Problems with Hypo: Best Design Practices for Smooth and Efficient Sodium Hypochlorite Feed Systems Chad Hantelman, City of Bremerton Jeff Zahller,

2700 DUST CONTROL MACHINE:

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Irrigation Pump Variable Frequency Drive (VFD) Energy Savings Calculation Methodology. Public Utility District No. 1 of Chelan County

world class fire pumps

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

1998½-2007 Dodge Ram 5.9L Cummins

400B SERIES DIAPHRAGM PUMP

BERMAD Fire Protection

Element D Services Plumbing

Load Bank Buyers Guide 60 hz models

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Diesel Generating Set

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Godwin NC series Dri-Prime pumps

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Basic Nameplate Information

Industrial Generator Set Accessories

2013 Jetters. Ph: Fax: Effective January 1, 2013

Frequently Asked Questions Generators

Industrial Monitors. Weight lbs. (Kg) Style. 55* (24.9 kg) 14"** (356 mm) * Less nozzle ** Less handle. Weight lbs. (kg) Style / 16"** (538 mm)

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

NFPA31FuelOilPiping 1 Revised

Multistage high-pressure multistage centrifugal pumps

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Quik Lining Systems Heater Owners Guide

Pipe Cutting and Beveling Clamshells

Spark-ignited generator set

Section 11 - System Diagrams

Heavy Duty Industrial Air Compressors

Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form

Section 6 - System Diagrams

Industrial Generator Set Accessories

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Transcription:

SPP Pumps Inc. Atlanta

UL Listed, FM Approved Fire Pump Sets Horizontal Split Case Pumps Flows from 200-5000 US GPM Vertical Turbine Flows to 5000 US GPM In-Line Pumps Flows to 750 US GPM End Suction Flows to 1500 US GPM Residential 13D Flows to 70 US GPM

What s new and coming up Grooved end jockey pumps Already standard Grooved increasers standard with NBG packs New standard Class 250# flanges Grooved fire pumps Spring 2013

Types of Fire Pumps Split Case Fire Pumps Inline Fire Pumps Vertical Turbine Fire Pumps End Suction Fire Pumps Residential 13D Fire pumps

Everything you need to know about fire pumps.

Types of Fire Pumps

HORIZONTAL SPLIT CASE ELECTRIC

HORIZONTAL SPLIT CASE DIESEL

Split Case Fire Pump Models Ease of Installation and Maintenance Longevity and Durability Serviceability Reliability Typical applications Warehouse Hospital Manufacturing plant University or large school Office High Rise

VERTICAL INLINE (ELECTRIC ONLY)

Vertical In-Line Requires less space than split case pump of the same capacity Typically Less expensive Motor can be serviced without disconnecting suction & discharge flanges from piping Typical applications Small schools Churches Parking garages

END SUCTION ELECTRIC

END SUCTION DIESEL

VERTICAL TURBINE ELECTRIC

VERTICAL TURBINE DIESEL

Vertical Turbine Fire Pumps

Vertical Turbine Design Features No priming Adaptability to water level Adaptability to various driver combinations Compact footprint No alignment necessary Minimal maintenance

Vertical Turbine Applications Vertical Turbines Applications where city water is not available Ponds and lakes to utilize water supply Only pump approved for suction lift conditions

90% rule 90% of what drives a pump quote is? Flow Pressure

Electric or Diesel? Electric sets are typically used where there is a reliable source of power What to ask.. What voltage? 208? 230? 460? Transfer Switch? Transfer switch is used when the source of power may not be reliable and/or precaution. Transfer switch for 2 nd utility Starting method? Full voltage? across the line Reduced Voltage? Part winding Primary reactor Wye Delta Open Wye Delta closed Soft Start Auto Transformer That s all you need to know. See rapid

Typical Brands of Fire Pump Controllers Firetrol Master Metron Cutler Hammer Joslyn Clarke Tornatech

Electric motors Electric motors are used to drive Horizontal split case End suction Vertical inline Vertical turbine Motors are selected based on Voltage HP required by the pump Frame size Configuration of pump (i.e. vertical or horizontal)

Typical Brands of Electric Motors WEG Motors US Electric Motors Marathon GE

Why Diesel? Diesel units are used primarily where there is not a reliable source of power or by preference Typical Engine Manufacturers Clarke engines (John Deere) Cummins Caterpiller Diesel units may drive Horizontal split case Vertical turbine End suction Engines are selected based on HP of pump requirement RPM EPA emissions standards as stated on presentation below

Diesel controllers Diesel engine fire pumps are especially nice because of how reliable they can be and by the inexpensive control panel. There are only a few options tend to be required on diesel control panels. The most distinct difference is voltage of the battery used to back up the engine 12 volt DC? 24 volt DC?

What is a jockey pump? A jockey pump is a pressure maintenance pump set so that in the event of slight fluctuations in sprinkler system pressure, the fire pump will not need to turn on. Typically set 10 psi over the fire pump Jockey pumps are replaced frequently and can be purchased from you. What to ask? In order to sell a jockey pump, you will need to know. If the customer is replacing a jockey pump, you will at least need to know the following Boost pressure (can be found by adding at least 10 psi to the fire pump pressure setting HP (should be on the motor nameplate or jockey pump controller) Voltage (also on motor nameplate or jockey pump controller)

Jockey Pumps Regenerative Turbine Pumps Vertical Multi-stage

Jockey pump controller Jockey pump controllers very small and meant to supply power exclusively to the jockey pump

Fire pump accessories and NFPA 20 NFPA 20 suggests minimum pipe and accessory sizes based on flow. In the chart below, you can see how based on the flow, you can select what size flow meter you might need, what size suction and discharge pipe is needed and what size test header etc Thought you do not need to memorize this chart, it is a helpful tool.

Fire Pump Standards NFPA-20 Minimum Pipe Sizes For Fire Systems Based on NFPA-20, 1996 Edition Pump Rating in Suction Discharge Relief Relief Valve Meter Number and Size of Hose Hose Header GPM In. In. Valve In. Discharge In. Device In. Valves In. Supply In. 25 1 1 3/4 1 1-1/4 (1) 1-1/2 1 50 1-1/2 1-1/4 1-1/4 1-1/2 2 (1) 1-1/2 1-1/2 100 2 2 1-1/2 2 2-1/2 (1) 2-1/2 2-1/2 150 2-1/2 2-1/2 2 2-1/2 3 (1) 2-1/2 2-1/2 200 3 3 2 2-1/2 3 (1) 2-1/2 2-1/2 250 3-1/2 3 2 2-1/2 3-1/2 (1) 2-1/2 3 300 4 4 2-1/2 3-1/2 3-1/2 (1) 2-1/2 3 400 4 4 3 5 4 (2) 2-1/2 4 450 5 5 3 5 4 (2) 2-1/2 4 500 5 5 3 5 5 (2) 2-1/2 4 750 6 6 4 6 5 (3) 2-1/2 6 1000 8 6 4 8 6 (4) 2-1/2 6 1250 8 8 6 8 6 (6) 2-1/2 8 1500 8 8 6 8 8 (6) 2-1/2 8 2000 10 10 6 10 8 (6) 2-1/2 8 2500 10 10 6 10 8 (8) 2-1/2 10 3000 12 12 8 12 8 (12) 2-1/2 10 3500 12 12 8 12 10 (12) 2-1/2 12 4000 14 12 8 14 10 (16) 2-1/2 12

Fire Pump System Components Electric Fire Pumps Pump, base, coupling & guard Electric motor Controller - motor Suction and discharge gauges Automatic air release valve Casing relief valve

Fire Pump System Components Diesel Fire Pumps Pump, base, coupling & guard Diesel engine & fuel tank Controller - engine Suction and discharge gauges Automatic air release valve Batteries, racks & cables Cooling loop Commercial grade muffler, flexible exhaust connector & fittings

Accessories for Fire Pump ClaVal 55L Casing relief Valve ClaVal 2050B-4KG Main Relief Valve ClaVal 90G-21 Pressure Reducing Valve

Additional Accessories for fire pump Suction side eccentric reducer Discharge side concentric increaser Test Header Hose valves caps and chains

Residential 13D The Resistream comes in 2 styles both the open unit with corrosion resistant base for mounting as well as the fully enclosed unit for simple and complete installation. Both units are available in either 115 or 220 volt single phase power depending on horsepower

Suction Piping

Pump Rotation

How well do you know Fire Pumps? Fill in the blanks The first thing to ask when looking for a fire pump quote is the required and What are the 4 main types of fire pumps? Horizontal Vertical Turbine End Is the pump set driven by motor or Engine Do you need a (hint adds $13,000) What is the site? (hint 208/230/460)

I need a 1000 gpm at 90 psi fire pump, what size jockey do I need? What are the 3 points on a NFPA 20 pump curve? (no flow) % % You have a 500 gpm fire pump, what is the flow at 100%?