Titrette. class A precision. The next generation Digital Burette!



Similar documents
Titrette. class A precision. The next generation Digital Burette!

How To Test A Titrette And Digital Burette

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

Mitos P-Pump. product datasheet

Karl-Fischer Titration the method for determining water

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Tutorial 4 SOLUTION STOICHIOMETRY. Solution stoichiometry calculations involve chemical reactions taking place in solution.

Density/Specific Gravity/ Concentration Meter DMA 500

4-Channel Thermometer / Datalogger

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Hand-held thermometer Model CTH7000

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Experiment 8 - Double Displacement Reactions

How To Use A Flowmeter

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

ph and Acidity in Wine and Fruit Juice

CYMAQ Marking System AS200 + DS7050 N-14

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

Ion-selective Measurements

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Vacuum drying oven for non-flammable solvents

Multi-Range Programmable DC Power Supplies 9115 Series

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Decomposition. Composition

Milwaukee USER MANUAL

4.2 Bias, Standards and Standardization

Overflow valve with thread connection

Pressure Switch for gas and air

AR200. Refractometer User s Guide. Page 1

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

Pressure Dew Point Probe / Application Information

Quaternary Ammonium Compounds DOC

DC Electronic Loads 8500 series

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Test equipment for temperature and its reduction

Portable Density/Specific Gravity/Concentration Meter DMA 35

limit to percentage levels, a limited working range translates

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ArtisanLink Staining System is an automated special stains slide

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

General Chemistry Lab Experiment 6 Types of Chemical Reaction

Pressure regulating valve with modulating kit, type DRV

INFRARED REMOTE CONTROL HELICOPTER

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

Precision Lightmeters Made in Germany

High pressure reactors Where are your limits?

NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY

XP Series Balances Operation Manual

OPSIS LiquidLINE KjelROC Distillation Unit

OXIDATION-REDUCTION TITRATIONS-Permanganometry

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Standard methods in water analysis

IB Chemistry. DP Chemistry Review

W1 WORKSHOP ON STOICHIOMETRY

Calculating Molar Mass of a Compound

Omega Pipettor. Operating Instructions

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

PIEZOMETER AIRFLOW MEASURING RING

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

PortaSens ll G AS DETECTOR

USB/RS485 converter cable, complete

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

Instruction Manual. T3111 T3111L T3111P T3111Ex

Portable digital microprocessor thermometers with interchangeable probes

804 Ti Stand. Manual EN

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

VAV compact controller KNX / PL-Link

ORGANIC SAMPLE PREPARATION

VAV compact controller KNX / PL-Link

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Solutions and Dilutions

Determination of the enthalpy of combustion using a bomb calorimeter TEC

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

18 Conductometric Titration

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Number of moles of solute = Concentration (mol. L ) x Volume of solution (litres) or n = C x V

2 Port KVM Switch. If anything is damaged or missing, contact your dealer.

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Fixed and Adjustable Spacing Electronic Pipettes

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

DISSOLVED OXYGEN PROBE

Point of view HDMI Smart TV dongle Mini RF Keyboard

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

T0118 T2118 T3118. Instruction Manual

Transcription:

The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in close quarters, with no power hookup needed in the lab, in production, or in the field! High accuracy Precise titration within the error limits of Class A Smooth, low-force operation For sensitive, drop-wise titration Compact design Light and stable Easy handling No switching between 'fill' and 'titrate' Simple maintenance Cleaning and part replacement right in the lab PC interface (optional) Data transmission directly to the PC

A closer look The control elements of the Titrette bottle-top burette have an intuitive layout. Separate buttons for On/Off and Pause; Clear button allows user to reset the display and select functions. Easy-grip hand wheel action and smooth precision gears for fast or drop-wise titration make handling extremely simple and reliable. Digital display CLEAR/Select button PC interface (optional) (see ordering information) Replaceable batteries On/Off button Pause button Hand wheels Inspection window PTFE piston Glass cylinder Titration and recirculating valve Titrating tube horizontally and vertically adjustable, with integrated discharge valve Valve block Freely rotating (Bottle thread GL 45) Recirculating tube Screw cap Telescoping filling tube

Extras Four additional helpful electronic functions make your work easier. Hold down the CLEAR button to select the desired function: Adjustment with Easy Calibration With Easy Calibration technology, you can easily make calibration adjustments of the instrument 'at the push of a button'. No tools needed! An adjustment may be necessary if the instrument has been in use for a longer period or if parts are replaced. To show that an adjustment has been carried out, a small 'CAL' icon will be shown in the upper portion of the display. Calibration schedule To save a date for the next calibration, simply store it under 'GLP'. The date can be called up each time the instrument is turned on. Hold the on/off button down for a little longer, and the letters GLP, along with the month and year of the calibration date, are shown. Save power with Auto Power Off The instrument switches off automatically after longer periods of inactivity. The current display value is stored, and returned to the display after the power is switched on again manually. Under "APO" (Auto Power Off), you can set the time until automatic power-off from 1 to 30 minutes. Changing decimal place settings For use as a microburette, you can switch the titrated volume display from 2 to 3 decimal places under 'dp' (decimal point). Above 20.00 ml, the display automatically switches to 2 decimal places.

Easy Handling With the Titrette bottle-top burette, you can titrate drop-wise with great sensitivity. No switching needed between filling and titrating! The instrument is light-weight, compact, and can be dismantled for cleaning and maintenance in the lab. Easy handling! Smooth operation! The large, easy-grip hand wheels are conveniently easy to turn. With the optimized gear ratio, you can fill the device quickly and titrate drop-wise with great sensitivity. Class A precision! The Titrette bottle-top burette has an innovative new measuring system which matches the Class A accuracy of glass burettes and, if needed, can offer the precision of 3 decimal places below 20 ml. This is an important feature for users who need to work within the Class A error limits of glass burettes according to DIN EN ISO 385 (e.g., in pharmaceutical work). No switching needed! To change between filling and titration, no switching is needed. The instrument automatically detects whether you are filling or titrating by the direction of hand wheel rotation greatly reducing the risk of handling errors. Pressing the Pause button allows you to interrupt the titration if priming was incomplete. Simply push the button again to resume titration.

Easy Handling User seviceable! We have designed the instrument to be disassembled quickly and easily in a matter of minutes for cleaning, to replace the piston/cylinder, or to replace the batteries. Now you can carry out maintenance conveniently and easily in the lab, and in a few minutes the instrument is ready to go again! Light protection! For protection of light-sensitive media, you can replace the clear inspection windows with the amber colored windows (included). It's quick and easy, because the windows just clip into place. Light-weight and compact! All components move within the housing, reducing headroom requirements. The compact design and the light weight ensure good stability. The titrating tube can be adjusted horizontally and vertically. This provides flexibility when positioning the instrument, e.g., when using a magnetic stirrer or different bottle sizes.

Technical data Comparison of error limits Titrette bottle-top burette Bottle-top burettes acc. to DIN EN ISO 8655-3 Glass burettes Class A acc. to DIN EN ISO 385 Volume ml Partial volume ml A* ± % µl CV* % µl A* ± % µl CV* % µl EL** ± µl 25 25 0.07 18 0.025 6 0.2 50 0.1 25 30 12.5 0.14 18 0.05 6 0.4 50 0.2 25 30 2.5 0.70 18 0.25 6 2 50 1 25 30 50 50 0.06 30 0.02 10 0.2 100 0.1 50 50 25 0.12 30 0.04 10 0.4 100 0.2 50 50 5 0.60 30 0.20 10 2 100 1 50 50 * Error limits related to the nominal capacity (= maximum volume) indicated on the instrument, obtained when instrument and distilled water are equilibrated at ambient temperature (20 C/68 F) and with smooth operation. ** Error limit: EL = A + 2CV (A = accuracy, CV = coefficient of variation, EL = error limit) The maximum resolution of the display: 25 ml instrument: 0.001 ml, above 20 ml titration volume 0.01 ml; 50 ml instrument: 0.002 ml, above 20 ml titration volume 0.01 ml. Note: If you need an official certification which confirms the error limits that are much stricter than those of DIN EN ISO 8655-3, we recommend a calibration certificate from an accredited calibration laboratory (e.g., the DKD laboratory at BRAND). Material and reagents The instrument can be used for the following titration media (maximum concentration 1 mol/l): Acetic acid Alcoholic potassium hydroxide solution Ammonium iron (II) sulfate solution Ammonium thiocyanate solution Barium chloride solution Bromide bromate solution Cerium (IV) sulfate solution EDTA solution Hydrochloric acid Iodine solution Iron (II) sulfate solution Nitric acid Oxalic acid solution Perchloric acid Potassium bromate solution Potassium bromate bromide solution Potassium dichromate solution Potassium hydroxide solution Potassium iodate solution Potassium permanganate solution Potassium thiocyanate solution Silver nitrate solution Sodium arsenite solution Sodium carbonate solution Sodium chloride solution Sodium hydroxide solution Sodium nitrite solution Sodium thiosulfate solution Sulfuric acid Tetra-n-butylammonium hydroxide solution Zinc sulfate solution When the instrument is properly handled, dispensed liquid will only come into contact with the following chemically resistant materials: borosilicate glass, Al 2 O 3, ETFE, PFA, FEP, PTFE, platinum-iridium; PP (screw cap). Limitations of use Chlorinated and fluorinated hydrocarbons or chemical combinations which form deposits may make the piston difficult to move or may cause jamming. Compatibility of the instrument for a special application (e.g., trace material analysis) must be checked by the user. For additional information, please contact the manufacturer. The instrument is not autoclavable! Operating limits This instrument is designed for titrating liquids, observing the following physical limits: +15 C to +40 C (59 F to 104 F) of instrument and reagent Vapor pressure up to 500 mbar Viscosity up to 500 mm 2 /s Altitude: maximum 3000 m above sea level Relative humidity: 20% to 90%

Ordering information Titrette Items supplied: Titrette bottle-top burette, conformity certified, performance certificate, telescoping filling tube (170-330 mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 PP bottle adapters (GL 45/32, GL 45/S 40, GL 32/NS 29/32), 2 colored light shield inspection windows, operating manual. Standard with RS 232 interface* Volume Cat. No. Cat. No. 25 ml 4760 151 4760 251 50 ml 4760 161 4760 261 Note: When ordering devices with DKD certificates, the prefix "DKD" must be added to the order number, e.g., DKD 4760 161. * Additionally included: connector cable (Sub-D plug connector, 9-pin), one CD (driver software and open RS232 communication protocol). The CD also includes an example application in XLS-file format, as well as a special operating manual. Storage conditions Store the instrument and accessories at dry conditions. Storage temperature: -20 C to +50 C Relative air humidity: 5% to 95% PC interface (optional) The instrument is available with an optional RS 232 communications interface. Advantages compared to the standard configuration: The titration results are automatically transmitted to the PC by double-clicking on the CLEAR key. This eliminates transcription errors while recording primary data, and complies with an important requirement of GLP. With each data transfer, the burette sends the titrated volume, the serial number of the instrument, the nominal volume and the adjustment value, as well as the next scheduled calibration date. Thus, all raw data is collected. The transmitted data is recognized as keyboard inputs by the PC. This universal input format ensures that the instrument is compatible with all PC applications that accept keyboard inputs. To connect the instrument to a USB interface, simply use a standard USB/RS 232 adapter.

Accessories Spare parts Titrating tube with screw cap and integrated discharge and recirculation valve. Cat. No. 7075 26 Telescoping filling tube FEP. 170-330 mm Cat. No. 7042 04 250-480 mm Cat. No. 7042 05 Filling valve with olive-shaped nozzle and sealing ring. Cat. No. 6636 Inspection window 1 set colorless and 1 set amber colored (light shield). Cat. No. 6783 Piston head for vol. 25 ml Cat. No. 7075 30 for vol. 50 ml Cat. No. 7075 32 Dispensing cylinder with valve head for vol. 25 ml Cat. No. 7075 34 for vol. 50 ml Cat. No. 7075 36 For laboratory bottles, and an assortment of adapters, please visit www.brand.de. 9943 55 Printed in Germany 3/0808 Titrette and BRAND are trademarks of BRAND GMBH + CO KG, Germany. Our technical literature is intended to inform and advise our customers. However, the validity of general empirical values, and of results obtained under test conditions, for specific applications depends on many factors beyond our control. Please appreciate, therefore, that no claims can be derived from our advice. The user is responsible for checking the appropriateness of the product for any particular application. Subject to technical modification without notice. Errors excepted. BRAND GMBH + CO KG P.O. Box 1155 97861 Wertheim Germany Tel.: +49 9342 808-0 Fax: +49 9342 808-236 E-Mail: info@brand.de Internet: www.brand.de