USER MANUAL ESP. Enhanced Steering Performance. R-Net



Similar documents
TECHNICAL MANUAL. ICS Onboard Configuration

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

ViZion Installation Guide

R-NET MOUSE MODULE TECHNICAL MANUAL SK

Points Position Indicator (PPI1) for Points Motors with Common Ground

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Introduction to Electronic Signals

G-100/200 Operation & Installation

POINTS POSITION INDICATOR PPI4

PUSH BUTTON START INSTALLATION MANUAL

WD-AMX Water Detection Controllers

Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.22

Sigma Control PC INSIDE. 97 psi 187 F R on load

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

1 Technical Description Lokal-200PC

Operational Overview and Controls Guide

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Inwall Room Temperature Unit

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

L5354 ControlNet Communications Interface

AMS-1000 Multi-Channel Air Management System for Boost Control

SERVICE MANUAL. Permobil C500. Power wheelchair

Upgrade Instructions. View Manager 96 v Software Upgrade

Mastertech Diagnostic Software Frequently Asked Questions

Laboratory Course Industrial Automation. Experiment Nr. 6. Introduction to the FlexRay bus system. Brief User Guide IAS Demonstrator Go-Cart

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

USER MANUAL. EZRUN Series Brushless Speed Controller EZRUN-150A-PRO

Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

19 LED Tube Controller ORDERCODE 41003

Signature and ISX CM870 Electronics

How To Control Gimbal

Air conditioning, electrical testing

ABB PSPS Erich Steinmann; Generator control-2013

Haier Air conditioner

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

Running a Load Flow Analysis

QTRONIX Programmer Pad

Compressor Supreme Force Feedback User Manual

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Twido Simulator - Online Help Scope What's in this Part? Twido Simulator Overview What's in this Chapter? How to Use Twido Simulator

Smart relays Zelio Logic Step into an intuitive world!

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

Transmission electronic controls outline. Inputs- processing- outputs

FRC WPI Robotics Library Overview

Programming the VEX Robot

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Installation and User Guide

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Troubleshooting and Diagnostics

MARTECH SPI Tools. MARTECH SPI Tools User Manual v1.0. User Manual

ADS Online MANUAL / USER S GUIDE

PHD User Manual. Table of Contents

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

S-Tec System Thirty Autopilot

A.3 ALARMS (SERIAL SPINDLE)

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

Congratulations on purchasing Molten MIDI B by Molten Voltage

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

How to read this guide

B/S/H/ Error codes and service programmes PH

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

2.1 FOR Series 15i Servo Alarm TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks

Parts List. Navigation

PYRODIGITAL CONSULTANTS PD Firing Module Continuity Reader

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

Troubleshooting the Verizon MI424WR Router

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

IDS X-Series User Manual D Issued July 2012

ELECTRONIC BOARDS - SUPRA

Multi-Range Programmable DC Power Supplies 9115 Series

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

Field Calibration Software

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version


MINIMAT-EC-Servo Screwdriver Spindles

S7 for Windows S7-300/400

Features, Benefits, and Operation

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Analog Input Module Cat. No IFE User Manual

Vario Tractors - Fault Codes. Faults. all Vario tractors Tractor / General system. EDC / EMR bus fault. Fault in ECU Programming errors in ECU.

Unsuccessful Calibration 2. Proper Cable Routing 5. Latch Bolt Operation 6. Audio/Visual Feedback 7. Touch-To-Open Functionality 10.

ABS/VDC WHEEL SPEED SENSOR DIAGNOSIS

SECTION VARIABLE FREQUENCY DRIVES

How to Configure your Energate Foundation Wi-Fi USNAP Radio Module.

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

T7560A,B,C Digital Wall Module

Electronically Controlled Air Suspension (ECAS) for Trucks

Transcription:

USER MANUAL US ESP Enhanced Steering Performance R-Net

ESP Enhanced Steering Performance R-Net Produced and published by Permobil AB, Sweden Edition 1, 2008-04 Product code: 205229-US-0

How to contact Permobil Head Office of the Permobil group

User Manual ESP Contents Contents Introduction... 6 Safety rules... 7 Programming... 8 Error indications... 9 Troubleshooting... 10 5

User Manual ESP Introduction Introduction The purpose of the ESP module is to make your wheelchair safer to use. ESP stands for Enhanced Steering Performance. The ESP module is programmed by Permobil to give the wheelchair optimal performance. Individual adaptations can mean that minor adjustments may be required at a later date. The preprogrammed parameters may only be adjusted by technicians familiar with the ESP module. The ESP module is installed in the wheelchair chassis. See the service manual for the chassis for further information. The ESP module is connected to the wheelchair control system. The module contains a sensor that measures any course deviations made by the wheelchair. A processor uses this information to correct any deviations from the course set by the user using the wheelchair s steering device. The ESP module uses the information from the sensor and the steering device to calculate a corrected steering signal. The steering signal is then passed on to the wheelchair s R-Net output stage, which controls the drive motors. The function of the ESP module requires access to the full capacity of the output stage. These different parameters must therefore be adjusted to their maximum values or to other predefined values. NB. The parameters for the output stage, Power Module (PM), are set by Permobil and must not be changed. The ESP module has integral functions for controlling the wheelchair s performance, acceleration, course stability, etc. If any changes are required to the way the wheelchair is operated, the ESP module must be reprogrammed. 6

User Manual ESP Safety rules Safety rules - There must be no changes made to the output stage parameters. - The ESP module may only be programmed by technicians familiar with the ESP module s functions. - Changes made to the ESP module parameters must be documented. The parameter values must be recorded before and after changes. - Wheelchairs with ESP module installed are supplied programmed for optimum performance. Changes to the value of a parameter should mean a decrease in the current value. Raising a parameter s value can mean that the wheelchair becomes unstable and difficult to maneuver. - Once changes have been made to ESP module parameters, the wheelchair must be test-driven before being returned to the user. NB. If tests are performed in which the ESP module is disconnected, please note that steering characteristics are set to a very high value. This makes the wheelchair very difficult to maneuver. Ensure that there is plenty of space around the wheelchair when the test is being performed. 7

User Manual ESP Programming Programming The ESP module has 20 parameters adjusted using Permobil PC Programmer for R-Net, product code 1822585, and the associated dongle. The procedure is described in greater detail in the PC Programmer for R-Net User Manual. The ESP module is installed in the chassis. It is not possible to program the module directly. The 20 programmable parameters can be seen in Fig. 1. Fig. 1. Example of settings for R-Net control panel with joystick, JSM. The first 19 adjust R-Net output stage (PM) parameters for speed, which can be set for optional drive profiles. The twentieth parameter, switched input, is used to select the drive device used for each profile. No position means analog joystick or attendant control. For button control, change the parameter to Yes. 8

User Manual ESP Programming and parameter settings Error indications The ESP module is equipped with two LEDs, one green and one red, to indicate module status. See Fig. 2. These are useful for troubleshooting. The table in Fig. 3 shows the functions of the LEDs. The green LED means the wheelchair is ready for use. The red LED gives access to various error codes by flashing at different intervals. The number of flashes indicates which error code it concerns. See section on troubleshooting, page 10. Fig. 2. Both LEDs on the ESP module show the current status of the module. The red LED is on the left in the picture, and the green is on the right. Status Red Green Before start Off Off Module is not active On Off Normal mode, wheelchair functions according to completed calibrations Off On Calibration mode On On Error indication Flashes Off Fig. 3. Various indications of the LEDs. 9

User Manual ESP Software version and troubleshooting Troubleshooting There are a number of flash codes to assist in troubleshooting. The red LED on the ESP module flashing a certain number of times indicates an error. The table below specifies what error a certain number of flashes indicates. The control panel display also normally shows an error message in text format. Permobil s PC Programmer for R-Net provides further information on errors indicated. Description of error Power Module in Latched Drive Mode Incorrect reference voltage, VCC/2 PWM Offset adjustment outside its working range Gyro sensor value outside specified limits Module Test Flag not set in EEPROM Incorrect calibration value in EEPROM Cannot read program object in time, time limit reached. AD/DA Controller not synchronized LCD text on control panel 10 Flashes Check and/or replace Bad Settings 1 Programming Module Error 2 ESP module Module Error 3 ESP module Module Error 4 ESP module Module Error 5 ESP module Recalibrate 6 ESP module Cycle Power 7 Cycle Power 8 Switch system off/on. Check cabling and all R-Net units. Switch system off/on. Check cabling and all R-Net units. Non-existent instruction Module Error 9 ESP module Program/system error Module Error 10 Switch system off/on. Check cabling and all R-Net units.

Product code: 205229-US-0