Preset Counter signo 721



Similar documents
Flexible Counter Series in DIN size 24 x 48 mm

Variable Preset Counter signo 723.1

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Multifunction devices

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Short information Parameters are programmed via front-side membrane keypad

Industrial Counting and Control Components

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Digital Pressure Measuring Instrument MDR480

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Quick Connect. quick - simple - efficient.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Three-phase monitoring relay CM-PFE

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

PHOENIX CONTACT Features

Actuator-Sensor-Interface

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Power Supplies 3. SDN-P DIN Rail Series

Cross-beam scanning system to detect slim objects. 100 mm in

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Capacitive Prox E2K-X

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Safety technique. Emergency stop module BO 5988 safemaster

is then retained absolutely without interruption.

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Speed Control Relays SX2

E-STOP relays, safety gate monitors

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Contact expansion modules

Digital input modules

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Multifunction Digital Timer

SKR - industry relay

E-STOP relays, safety gate monitors

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RM4TG20 three-phase network control relay RM4-T - range V

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Energy Management Energy Meter Type EM23 DIN

Type: DILM9 10(24VDC) Article No.:

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Contact expander modules

PNOZsigma - Base units

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

38 Series - Relay interface modules A

Voltage Regulator SPAU 341 C. Product Guide

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermal-Magnetic Circuit Breaker M1-..

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Emergency lighting units EM powerled

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

Electronic overload relay EF19 and EF45

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Electronic overload relay EF65, EF96 and EF146

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

48 SERIES Relay interface modules 10 A

Duct Humidity Transmitter

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

3-phase, bidirectional energy meter

Pluggable interface relays CR-P Pcb relays

Relés e Contatores de Estado Sólido SIRIUS

38 Series - Relay interface modules A

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

80 Series - Modular timers 16 A. Features

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

Contents. Document information

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

60 Series - General purpose relays 6-10 A. Features

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

HYDRUS ULTRASONIC METER

Type: DILM32 10(24V50HZ) Article No.:

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Transcription:

Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage Current consumption Power consumption LCD reflective; positively transmissive; black digits; background illumination negatively transmissive; red digits; illumination 2 rows, counter reading/presettings 5-digits decimal point (up to 4 decimals) 1st row 12,0 mm; 2nd row 6,0 mm SELV: 12-30 VDC; protected against polarity reversal SELV: 24 VAC, 115 VAC, 230 VAC, 50/60 Hz, ± 10% 90-260 VAC; 50/60 Hz* 12... 30 VDC: < 200 ma, 24 VAC < 250 ma; including sensor supply 115 VAC, 230 VAC < 50 ma; including sensor supply 90-260 VAC < 400 ma; incl. sensor supply < 5 W Duty cycle 100% Overload protection Overload protection Relay output Sensor supply Storage of values Electrical connections Cable cross-section external fuse DC: 0,16 AT (IEC 127); DC: 0,2 AT (UL 198) 24 VAC: 315 mat 230 VAC: 32 mat; 115 VAC: 63 ma T external fuse 230 V, 2,5 ma T Only for AC operation: 12-24 VDC load-dependent; max. 50 ma NV-memory > 10 years Plug-in screw-type connections / Terminals 1...1.5 mm² with wire-end sleeves Data sheet signo721 23/03/2010 page 1 von 5

Amplitude threshold Active edge < 2 V and > 8 V or < 1 V and > 4 V at TTL-level amplitude max. 40 VDC programmable, positive for PNP-input, negativ for NPN-input Pulse form any desired form (at max. frequency square 1:1) Input resistance Clock frequency Pulse duration min. approx 10 kohm max. 60 khz (TTL 15 khz): single-channel counting max. 60 khz (TTL 15 khz): Differential counting and totalizing channel (A+B together) max. 30 khz (TTL 15 khz): phase discriminator single or double evaluation max. 15 khz (TTL 15 khz): phase discriminator, quadruple evaluation damped (attenuated) 30 Hz 17 ms ( 30 Hz); 8 µs (60 khz) Prescaler 0,0001-9,9999 Reset Display and Preset Range Signal times manual reset via keyboard, external reset via static or dynamic programming; pulse length min. 5 ms, automatic reset after reaching Preselect 2, (No pulse losses at max. counter frequency due to automatic reset function). via application input (programmable) - 99 999 up to + 99 999 0,01 s to 599,99 s or bistable programming; tolerance + 10 ms Relay Output Preset 1 und 2 Change-over contact max.: 250 VAC / 30 VDC / 5 A Change-over contact min.: 5 VAC / 5 VDC / 10 ma delay < 10 ms Transistor Output Preset 1 und 2 PNP-output 12-30 VDC max. 50 ma for DC supply 12-24 VDC max. 30 ma for AC supply 12-24 VDC max. 50 ma for AC with switching power supply*" Application Output PNP output 12-30 VDC max. 20 ma at DC supply 12-24 VDC max. 20 ma at AC supply COUNTER Counter mode of operation Input A,B Control Input Application Input/ Output Unidirectional; adding or subtracting; directional input; Differential operation, add / sub; Summation (Totalizing) add / add; Phase discriminator single, double or quadruple evaluation Reset; Gate, Hold Output Prescaler-out, Direction-out Input: Reset, Gate, Keylock, Hold Data sheet signo721 23/03/2010 page 2 von 5

ENVIRONMENT. CON. SAFETY RULES General design IEC/EN 61 010-1 Protection Class II; IEC/EN 61010-1 Pollution degree 2, EN 50178 EMC - Interference immunity EN 61326-1 industrial environment * EMC - Emission EN 61326-1 Class B * Ambient temperature Storage temperature 0... 50 C EN 60 068-2-1/2-20... + 65 C EN 60 068-2-1/2 Climate 40 C / 93% rel hum. class 4K4H, EN 60 068-2-78 25-50 C / 93% rel hum., cyclic, EN 60 068-2-38 Degree of protection IP 65 front side; EN 60529 IP 20 terminals Vibration resistance 10 m/s² (10... 150 Hz); EN 60 068-2-6 Shock resistance 100 m/s² (18 ms); IEC 60 068-2-27 Resistence to chemicals Approvals RoHS Frontfoil nach DIN 42 115-2 UL, CSA (under preparation) compliant MECHANICAL DATA Dimensions Installation Front-panel cutout Weight 48 mm x 48 mm x 118 mm, installation depth 110 mm DIN 43700 Front-panel installation with tenter (frame) Front panel thickness max. 11 mm 45 mm x 45 mm +0,3 mm approx. 200 g * For cable length > 30 m, for connection to a DC-supply- network and input level TTL and additional protection circuit is neccessary. Data sheet signo721 23/03/2010 page 3 von 5

CONNECTIONS 2 721 209 2 721 212 VDC 2 relais / 2 transistors VAC Trafo 2 relays / 2 transistors 2 721 206 2 721 207 VDC 1 relay / 1 transistor VAC Transformer 1 relay / 1 transistor 2 721 213 2 721 208 VAC switching power supply 2 relays / 2 transistors VAC switching power supply 1 relay / 1 transistor Data sheet signo721 23/03/2010 page 4 von 5

ORDERING INFORMATION Display Relay 12-30 VDC 24 VAC 115 VAC 230 VAC 90-260 VAC(SN) LCD transmissive red 1 0 721 201 0 721 202 LCD transmissive red 2 0 721 205 0 721 206 LCD reflective 1 0 721 301 0 721 309 0 721 332 0 721 342 0 721 302 LCD reflective 2 0 721 305 0 721 310 0 721 336 0 721 346 0 721 306 LCD transmissive positive 1 0 721 401 0 721 402 LCD transmissive positive 2 0 721 405 0 721 406 Reflective: black digits on a bright reflecting background Positively transmissive: black digits on an illuminated background Negatively transmissive: red illuminated digits on a black background Data sheet signo721 23/03/2010 page 5 von 5