Contamination Control and Environmental Monitoring Systems



Similar documents
How To Control A Medical Device With A Pc System

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Compact Monitoring Technology your environmental monitoring solution

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Testing Automated Manufacturing Processes

Monitoring manufacturing, production and storage environments in the pharmaceutical industry

Pharmagraph. GMP/GLP Monitoring System

REAL TIME LABORATORY MONITORING SYSTEM

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

Monitoring the autoclaving process in the pharmaceutical industry

Smart. Scalable. Simple.

GAMP5 - a lifecycle management framework for customized bioprocess solutions

Wireless Particle Monitoring of Pharmaceutical Cleanrooms

EU GMP Annex 1 Update 2008: Airborne Particle Counting

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

API Marine. BMS Presentation. Ballast Measurement Systems

VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING. F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group

Validation of process gas systems

Workflow System for Paperless Air Monitoring Powered by MODA. Presented by

Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Training Course Computerized System Validation in the Pharmaceutical Industry Istanbul, January Change Control

Fire alarm system EBL512 G3

Environmental Monitoring

The Central Monitoring System we prove it.

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Installation, Operation and Performance Qualification of a Thermoguard Installation

Process Instrumentation

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Environmental Monitoring of Clean Rooms

ThermoSorb Desiccant Dryers

WEATHER STATION FOR SOLAR FARM MONITORING

The Central Monitoring System Reliable, flexible, compliant

Intelligent Vibration Monitoring

Dew-Point Measurement Solutions

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Appendix 5 Overview of requirements in English

Using the ISPE s GAMP Methodology to Validate Environmental Monitoring System Software

GUIDE TO GOOD MANUFACTURING PRACTICE FOR MEDICINAL PRODUCTS ANNEX 15 *

SMS GSM Alarm Messenger

Environmental Monitoring

The FDA recently announced a significant

cleanroom validation Cleanroom Validation

Computerised Systems. Seeing the Wood from the Trees

OPERATIONAL STANDARD

Medical Waste Autoclaves. Medical Waste Autoclaves

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

International Standard ISO 14644

Pharmaceutical Industry Whitepaper

Regulations Concerning

NEW. EVEN MORE data acquisition and test stand automation

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

FACILITY MONITORING SYSTEM DESIGN RECOMMENDATIONS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

New changes to cleanroom & clean air device classifications: ISO & 2

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Temperature & Humidity SMS Alert Controller

Packaging Validation according to ISO 11607

German engineering under high pressure

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

2.24. Pump Controller 704. Data Sheet

Instruction Manual. T3111 T3111L T3111P T3111Ex

Library Guide: Pharmaceutical GMPs

Spetec. Laminar Flow Box. Portable Clean Room Technology

How is Dew Point Measured Reliably?

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Mirador. Features include: Applications:

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Environmental Chamber. Stability/ GMP 2000 Series. Stability Testing Chambers

INTRODUCTION. This book offers a systematic, ten-step approach, from the decision to validate to

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

4Sight Calibration Management Software

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Raleigh, NC May 12 th & 13 th Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply?

Wireless Data Logger Monitoring Systems

Lighthouse Worldwide Solutions Master Presentation

Alfa Laval PureBallast 3.1

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

On-line Machine Condition Monitoring [The CMS System]

Laminar Flow Cabinets and Workstations

MHRA GMP Data Integrity Definitions and Guidance for Industry January 2015

HEAVY WATER LEAK DETECTOR

Operating Principle of the Sample Positioning Flaps

MHRA GMP Data Integrity Definitions and Guidance for Industry March 2015

In-Line Electronic Flow Switches

Environmental Monitoring, Alarming & Reporting When Product Safeguards & Compliance are Required

LyoBeta. R+D Freeze-Dryers

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

REAL-TIME DUST AND AEROSOL MONITORING

BSL3 and BSL4 Autoclaves. Laboratory Line

Transcription:

Life Science Contamination Control and Environmental Monitoring Systems Hospital Electronics Brookhaven Instruments deliver, install and validate particle counters, Microbial Air Samplers and Monitoring Systems for clean rooms and other GMP critical areas. Our systems can monitor particle, microbial, differential pressure, temperature, humidity and other critical parameters. Tissue Banks You request - we design!

Project Life Cycle Brookhaven Instruments offer full validation of the monitoring system including life cycle documentation according to GAMP5 and VPCS from ISPE. We also supply complete software design & validation documentation. Change Control 2 System Design & Refinement 1 System Idea It all starts off with an idea from your side. Either you already have a monitoring system that needs to be upgraded with critical parameters, sofware version or you are installing a new system. If you want we can help you with inputs to write a Risk Assessment Document to verify that all the critical parameters within the monitoring system is covered. 2 System Design & Refinement From the Risk based approach an URS (User Requirement ) is developed to make sure that all your requirements for a monitoring system are specified. 1 System Idea 5 Decommissioning Validation Plan 5 Decommissioning When your system or parts of the system comes to the end of the lifecycle we can help you with executing a controlled decommissioning. This could include: Final backup of data Final calibration of sensors Final tests to verify that the system were in a validated state Decommissioning Report QPP- Quality & Project Plan FDS- System Function SCS Software Config ISP Installation ITL Item List Risk Assessment URS High Risk (Q) Low Risk (C) Functional Design Design Qualification Change Control System Built at Us DRW Drawings DQP DQ Protocol DQP DQ Report

3 System Implementation 3 System Implementation We offer an comprehensive validation package to make sure you are in compliance with the regulatory demands. Since we have extensive experience from working with the Pharmaceutical Industry we write our own documentation. We implement our systems according to our own GAMP5 V modell. 4 Maintenance Brookhaven Instruments GAMP5 V Model Interpretation Operational Qualification (OQ) Installations Qualification ( IQ ) Validation Report Performance Qualification (PQ) PQ Report OQ Protocol OQ Report IQ Protocol Traceability Matrix 4 Maintenance & Service When you have made an investment in a monitoring system or instrument you want to make sure that it will be in good condition and running for as long as possible without any major failures. We offer many levels of service agreements such as: Calibration on particle, microbial and en vironmental sensors at our calibration laboratory or on site with our specially designed calibration bus. Extended warranty on system parts or the complete system including travel & labor costs. Yearly re-qualification of the system to maintain the validated state. Commissioning (C) IQ Report FAT ( C & Q ) Commissioning Protocol Cabling & Tubing Installation FAT Protocol FAT Report

Environmental Monitoring In a clean room there are many parameters to monitor to make sure that the room stays in a controlled condition. Some of the most common parameters that are monitored includes: Room Temperature Room Humidity Room Differential Pressure Particle Monitoring When your need for continuous particle counting is established we have many different particle sensor to choose from for integration into a monitoring system. Maybe you have have a need for a VHP resistant particle sensor or with a built in pump, we know what is best for your application. We can offer data communication via 4-20mA, RS-485 or TCP/IP. We also design our own solutions for installation of the particle sensor like a stainless steel box with inspections window and a isokinetic sampling probe with a unique lid that can be fitted on top when cleaning is performed. Monitoring Architectu We shall relive our custo of compliance When you invest in a monitoring system fro be sure that you will be in compliance from requirements from FDA, EC-GMP & ISO. Th phases from design & installation through according to the GAMP5 guidelines for GxP Communication Cabinet The communication cabinet is the central part of the monitoring system. All communication with surrounding input & output parameters is routed through the cabinet. In the cabinet we mount devices like: Automated Microbial Sampling We can deliver a fully automated microbial sampling solution. It means that for your most critical areas in a grade A & B environment where you would monitor for microorganisms on a day to day basis we can simplify that work for you. A microbial sampling head is installed at a fixed location at your critical points. The sampling head can be controlled via an operator panel where start & stop is executed. Within the monitoring software the measuring point name, start & stop time, who started the measurement and any potential flow failure is recorded. This can later be printed together with your batch report. You can also if wanted record your microbial data after incubation. The head is compatible with 55 mm contact plates or 90 mm petri dishes. Monitoring Software In our system we use a software that is developed for one purpose only, to monitor critical parameters like particles, microorganisms, differential pressure, temperature and humidity etc. It is a GAMP5 category 4 software (configurable software). It is fully validated and comes delivered with a complete lifecycle documentation. It uses a modern database like MS SQL database which ensures a flexible and stable data collection and storage. The software is supported by all the Nordic languages and it can be used together with touch panels, SMS and E-mail services. It is also compatible with OPC server solutions.

System re mers from the burden m Brookhaven Instruments you can the beginning. Our system will meet the is is possible since all our project qualification & handover are executed Computerized Systems. Analog Input Digital I/O Relay Output RS-485 to TCP/IP Network Switch 24V Power Supply UPS SMS Modem Monitoring Computer Server Redundant Server (Buddy) Network Clients Equipment Monitoring Any equipment that is critical for your process we can monitor. The equipment may have a built in sensors that supplies a 4-20mA or 0-10V signal or we install a sensor for it. Examples of critical parameters are: Incubators Refrigerators & Freezers Ultra Low Temperature Freezers Air Flow Gases TOC & Conductivity Alarms & Human Machine Interface The monitored process parameters and alarms might need to be displayed for the operator or supervisors. We offer several solutions like: Clean Room Operator Panel Alarm Beacon SMS E-mail VPN-Client Security Call Center Software Data Output Reports PDF CSV Local Area Network Building Management Systems Data Backup Network Clients Printers Control & Automation There might be processes that you would like to automate or control. Examples of those are: Digital signals to & from process equipment Controlled changes of alarm limits Changes in ventilation speed Switching of valves Web Camera Monitoring

Calibration of Particle Counters and Microbial Air Samplers We have a state of the art mobile calibration laboratory equipped with all necessarily instruments to perform calibration of almost any brand of Aerosol Particle Counters. We can also perform calibration of microbial air samplers. Calibration of Aerosol Particle counters can be calibrated according to existing standards or the new ISO 21501-4 standard. Book time for calibration You contact us to book a date that is suitable for you to calibrate your particle counter Re-Calibration When it is time for re-calibration of your instrument, we contact you for a new date to be set Pickup of Instrument We arrive at your site and pick up the instrument at decided location Handover of Instrument When the calibration is completed we handover the instrument to you and we also go through the calibration results Calibration We calibrate your instrument in our mobile calibration laboratory Certificates We issue a calibration certificate with all necessarily information to comply with regulations

Particle Counters and Microbial Air Samplers Portable Airborne Particle Counters Our Portable Particle Counters are the ones we recommend for clean room certification according to ISO 14644-1 & EC-GMP Annex 1. They use a higher air flow and the graphical interface is more user friendly. Pre set programs and alpha numeric locations can be saved in the memory. Data down load to external software is possible where you create your own report according to ISO 14644-1 or EC GMP Annex 1. The instruments comes with the following standard features: Airflow 28,3, 50 or 100 l/min 6 channels of particle data 0,3-25 µm particle size Software for data download to computer Transport Case Isokinetic Sample Probe Tripod Sample Tube IQ/OQ Document Microbial Air Samplers and Culture Media Brookhaven Instruments is in close cooperation with Miclev AB. Miclev is one of the leading suppliers in the Nordic region on Microbial Air Samplers, and PPM - pre prepared culture media and contamination control products. Together, we can offer our customers solutions for a wide spectra of different sampling methods like handheld sampling, remote sampling for Isolators, pressurized air sampling etc. Handheld Airborne Particle Counters Our Handheld Particle Counters can be used for spot checks of particle concentrations in normal environments like office areas, hospitals or any other non clean room area where particles are of interest. Particle leakage in filters & general particle classification in clean rooms is also possible. The instruments come with the following standard features: Airflow 0,1 CFM (2,83 l/min) 3 or 6 channels of particle data 0,3-5 µm or 0,3-25 µm Particle concentration from 2.000.000 counts/ft 3 Software for data download to computer Liquid Particle Counters Brookhaven Instrument supply liquid particle counters for the Life Science, Electronic and Chemical industry. We have both laboratory and On-line instruments. With our laboratory liquid particle counter you can perform QC-control for injectable solutions according to USP 788 and EP- 2.9.19 or sample ultra pure water down to nm particle size. Our On-line liquid particle sensors can be used for quantifying particle concentration in high purity water systems or Parts Cleanliness Testing. The sensors sensitivity starts at nm up to µm particle sizes dependent on your needs. Communication is done via 4-20mA or RS-232 or RS-485 Modbus.

Design Installation Validation Service & Support References Brookhaven Instruments We design and deliver your system according to your specifications. The system can be integrated into existing technology or new. If you wish we can help you with producing a User Requirement (URS) that is based on our many years of experiance. We build & test the system in our dedicated production area before delivery to customer site. We can take care of the whole installation since we have our own installation personnel. We also have a wide knowledge about what components that can be used. To secure that the system is built according to your specification we offer validation service through all the design steps. We work according to GAMP5/M6 and GAMP Good Practice Guide: Validation of Process Control Systems in all our projects för monitoring systems. We have knowledge about writing everything from Validation Master Plans to SOP s. We offer calibration in our own calibration laboratory and on site with our special designed calibration bus. We offer several levels of service agreements to secure the functionality of your critical system for many years ahead. We have satisfied customers within many different industries. We are happy to provide you with a reference that is working within your industry area. We have the greatest experience of Monitoring Systems for Clean Rooms within the Nordic countries. Jarl & co Reklambyrå AB, Enköping, nov 2009 Brookhaven Instruments AB SE/NO: Konsumentvägen 9-11, SE--125 30 Älvsjö Tel +46 (0)8-447 16 75 DK: Skovbrynet 26, 8450 Hammel Tel +45 28 83 76 33 FIN: Perel OY, Torpankatu 28, 05801 Hyvinkää Tel +358 19 87 11 422 info@brookhaven.se www.brookhaven.se We shall relieve our customers from the burden of compliance