SKR - industry relay



Similar documents
Elesta Elektrotechnik AG industry relays and accessories

RY2 miniature industrial relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

48 SERIES Relay interface modules 10 A

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

40 Series - Miniature PCB/Plug-in relays A. Features

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Model Number Structure

AZ420 MINIATURE GENERAL PURPOSE RELAY

Model Number Structure

49 Series - Relay interface modules A. Features

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

LAUBE TECHNOLOGY DRY REED RELAYS

RM4TG20 three-phase network control relay RM4-T - range V

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

60 Series - General purpose relays 6-10 A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

1 POLE - 8A Medium Load Control

SPST-NO SPDT DPST-NO DPDT

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Pluggable interface relays CR-P Pcb relays

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Telemecanique Zelio Relay complementary and easy to assemble

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Modular I/O System Analog and Digital Interface Modules

FP2 Relay. The Best Relaytion

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

HERZ-Thermal Actuators

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Cable Plug acc. to DIN EN , Form A

CQM1-SF200/CS1W-SF200

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Safety technique. Emergency stop module BO 5988 safemaster

Thermal-Magnetic Circuit Breaker M1-..

Product Catalogue. Relays with forcibly guided contacts

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Preset Counter signo 721

General Purpose Relays Accessories. Accessories Miniature Relay PT

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1a/1c 5A/10A small power relays

Data Sheet. Electro-mechanical counters Hengstler 800 series

Goodsky Technical Data. Contact Details

E-STOP relays, safety gate monitors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

General-purpose Relay

Circuit Breakers. NRC Series. NRC Series

Type: DILM9 10(24VDC) Article No.:

Solid-State Timer H3G

SPST-NO SPDT DPST-NO DPDT

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Power Supplies 3. SDN-P DIN Rail Series

Safety automation solutions

SERIES SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~

Description Part-No. Type PU. Nominal voltage DC12V Relais-SNR 12V 1W 20 DC 24 V Relais-SNR 24V 1W 20

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Speed Control Relays SX2

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

PNOZsigma - Base units

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

1 POLE - 5A SLIM POWER RELAY

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Actuator-Sensor-Interface

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

Capacitive Prox E2K-X

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Contact expansion modules

Transcription:

SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time, electrical and mechanical status indication as well as the unsurpassed construction from only six assemblies makes the relay to the excellent power switch. 8 adjustable functions and 8 selectable time ranges: these are the special features of the time module STM. With only one version of the module all essential features as operating voltage, functions and time ranges are adjustable. The result: a simple and cost-effective warehousing. Simple to handle screw-terminal and clear, rich in contrast labeled clamp identification, are the base for a problemles use. The ZKE/ZKX sockets permit a rapid and secure installation. The separated inputs and outputs are located at one level. There is also the possibility to plug a time module STM or other additional modules together with the SKR relay. features simple construction high contact load contact spring in Beryllium bronze safe wire diameter long life time large coil room electrical or mechanical status indication integrated manual actuation simple installation indelible scheme on socket or cover following international standards applications mostly used where a timedependent event must be headed switch panel making machine industry illuminations locking of functions gate control machine control 4 catalog 00 e / 04.03

type number key SKR 5 A... 04VDC coil voltage VDC = direct current VAC = alternating current standard voltage VAC: 04, 5, 30 V VDC: 04, 0 options D = double contact (AgCuNi) L = electrical position indication F = free wheel diode FL= free wheel diode and electrical position indication B = without manual actuation T = push-button actuation C = current coil relay version SKR 085 A SKR 5 A SKR A A = mechanical position indication standard: manual actuation order samples manual actuation position indication free wheel diode LED display SKR085 A VDC/AC SKR5 A VDC/AC SKR A VDC/AC SKR085 AF VDC SKR5 AF VDC SKR AF VDC SKR085 AL VDC/AC SKR5 AL VDC/AC SKR AL VDC/AC SKR085 AFL VDC SKR5 AFL VDC SKR AFL VDC catalog 00 e / 04.03 5

SKR085 - industry relay, 8-pole Industry relay with two change-over contacts in different versions. order numbers serial version SKR 085 A... VDC/AC with mechanical position indication contact specifications contact material contact type nominal switching capacity electric life expectancy inrush current max. switching current range switching power range AgCuNi single contact 50 VAC 0 A AC 500 VA 440 VAC 4 A AC app. 700'000 operations 50 VAC, 0 A, AC (360 operations/h) 40 A for 00 ms 50 ma to 0 A 0,3 VA(W) to 500 VA options general data electrical position indication SKR 085 L.. with free wheel diode SKR 085 F.. electrical position indication with free wheel diode SKR 085 FL.. double contact SKR 085 D.. without manual actuation SKR 085 B.. push-button actuation SKR 085 T.. current coil SKR 085 C.. (combinations with mechanical and electrical position indication and free-wheel diode are possible) mechanic life expectancy > 0 8 operations mechanical switching frequency 0 Hz pull-in time ms at DC / 3-0 ms at AC release time 3,5 ms at DC / -5 ms at AC bounce time normally open contact 3,5 ms at DC / 3-6 ms at AC bounce time break contact 9 ms at DC / 6- ms at AC shock resistance AK: > 0 g vibration resistance 0-55 Hz, AK: 0 g, RK: 3 g test voltage, coil/contact 500 Veff test voltage, open contact 500 Veff insulation resistance 0 Ohm weight app. 80 g installation situation any ambient temperature max. +70 C protection standard IP 40 accessories tests, instructions plug-in socket ZVE 8 ZKE 088 metal clamp ZKR 008 certificates insulation group UL, CSA, VDE VDE 00 / group C 50 VAC 6 catalog 00 e / 04.03

4 5 4 3 6 4 A 7 A 8 circuit diagram dimensions 3 35 48 0 35 coil specifications UB nominal voltage UN rated voltage 3,0,5,0,5,0 0,5 energizing voltage range 0 0 40 60 70 ambient temperature C DC-relay AC-relay standard coils for direct current (other voltages on enquiry) rated pull-in reset nominal resistance voltage voltage voltage current Ohm tolerance VDC at 0 C at 0 C ma at 0 C % 9,6 0,6 04 5 +/-0 4 9,, 50,0 480 +/-0 48 38,4,4 5,9 850 +/-0 0 88,0 5,5, 9'000 +/-5 0 76,0 7,58 9'000 +/-5 standard coils for alternated current (other voltages on enquiry) - single relay, no heat concentration by surrounding components with self-heating. - on time 00% ) max. energizing voltage without contact load ) min. energizing voltage (guaranteed value), without operation in advance. VAC 9,6 0,6 3,3 +/-0 4 9,, 04 5 +/-0 48 38,4,4 55 40 +/-0 0 88,0 5,5 3 '0 +/-0 0 76,0,0 4'450 +/-0 30 84,5,5 5'600 +/-0 catalog 00 e / 04.03 7

SKR5 - industry relay, -pole Industry relay with three changeover contacts in different versions order numbers serial version SKR 5 A... VDC/AC with mechanical position indication contact specifications contact material contact type nominal switching capacity electric life expectancy max. inrush current switching current range switching power range AgCuNi single contact 50 VAC 0 A AC 500 VA 440 VAC 4 A AC app. 700'000 operations 50 VAC, 0 A, AC (360 operations/h) 40 A for 00 ms 50 ma to 0 A 0,3 VA to 500 VA options general data electrical position indication SKR 5 L.. with free wheel diode SKR 5 F.. electrical position indication with free wheel diode SKR 5 FL.. double contact SKR 5 D.. without manual actuation SKR 5 B.. push-button actuation SKR 5 T.. current coil SKR 5 C.. (combinations with mechanical and electrical position indication and free-wheel diode are possible) mechanic life expectancy > 0 8 operations mechanical switching frequency 0 Hz pull-in time ms at DC / 3-0 ms at AC release time 3,5 ms at DC / -5 ms at AC bounce time normally open contact 3,5 ms at DC / 3-6 ms at AC bounce time break contact 9 ms at DC / 6- ms at AC shock resistance AK: > 0 g vibration resistance 0-55 Hz, AK: 0 g, RK: 3 g test voltage, coil/contact 500 Veff test voltage, open contact 500 Veff insulation resistance 0 Ohm weight app. 80 g installation situation any ambient temperature max. +70 C protection standard IP 40 accessories tests, instructions plug-in socket ZVE ZKE 8 ZKX 8 time module STM 00 metal clamp ZKR 008 certificates insulation group UL, CSA, VDE VDE 00 / group C 50 VAC 8 catalog 00 e / 04.03

6 4 5 7 4 8 3 3 4 A 9 34 0 A 3 circuit diagram dimensions 3 35 48 0 35 coil specifications UB nominal voltage UN rated voltage 3,0,5,0,5,0 0,5 energizing voltage range 0 0 40 60 70 ambient temperature C DC-relay AC-relay - single relay, no heat concentration by surrounding components with self-heating. - on time 00% ) max. energizing voltage without contact load ) min. energizing voltage (guaranteed value), without operation in advance. standard coils for direct current (other voltages on enquiry) rated pull-in reset nominal resistance voltage voltage voltage current Ohm tolerance VDC at 0 C at 0 C ma at 0 C % 9,6 0,6 04 5 +/-0 4 9,, 50,0 480 +/-0 48 38,4,4 5,9 850 +/-0 0 88,0 5,5, 9'000 +/-5 0 76,0 7,58 9'000 +/-5 standard coils for alternated current (other voltages on enquiry) VAC 9,6 0,6 3,3 +/-0 4 9,, 04 5 +/-0 48 38,4,4 55 40 +/-0 0 88,0 5,5 3 '0 +/-0 0 76,0,0 4'450 +/-0 30 84,5,5 5'600 +/-0 catalog 00 e / 04.03 9

SKR - industry relay, PCB version Industry relay with three changeover contacts in different versions order numbers serial version SKR A... VDC/AC with mechanical position indication contact specifications contact material contact type nominal switching capacity electric life expectancy max. inrush current switching current range switching power range AgCuNi single contact 50 VAC 0 A AC 500 VA 440 VAC 4 A AC app. 700'000 operations 50 VAC, 0 A, AC (360 operations/h) 40 A for 00 ms 50 ma to 0 A 0,3 VA to 500 VA options general data electrical position indication SKR L.. with free wheel diode SKR F.. electrical position indication with free wheel diode SKR FL.. double contact SKR D.. without manual actuation SKR B.. push-button actuation SKR T.. current coil SKR C.. (combinations with mechanical and electrical position indication and free-wheel diode are possible) mechanic life expectancy > 0 8 operations mechanical switching frequency 0 Hz pull-in time ms at DC / 3-0 ms at AC release time 3,5 ms at DC / -5 ms at AC bounce time normally open contact 3,5 ms at DC / 3-6 ms at AC bounce time break contact 9 ms at DC / 6- ms at AC shock resistance AK: > 0 g vibration resistance 0-55 Hz, AK: 0 g, RK: 3 g test voltage, coil/contact 500 Veff test voltage, open contact 500 Veff insulation resistance 0 Ohm weight app. 80 g installation situation any ambient temperature max. +70 C accessories tests, instructions PCB socket ZKR 003 metal clamp ZKR 008 certificates insulation group UL, CSA, VDE VDE 00 / group C 50 VAC 0 catalog 00 e / 04.03

6 48 7,6 30,48 35 5,08 5,08 7,6 0,6 0,6 3 4 4 34,3 ±0, 30,48 38,5 a b 5,4 3 circuit diagram 37 drilling plan (view on solder side) dimensions 35 5,4 0,6, x 0,8 coil specifications UB nominal voltage UN rated voltage 3,0,5,0,5,0 0,5 energizing voltage range 0 0 40 60 70 ambient temperature C DC-relay AC-relay - single relay, no heat concentration by surrounding components with self-heating. - on time 00% ) max. energizing voltage without contact load ) min. energizing voltage (guaranteed value), without operation in advance. standard coils for direct current (other voltages on enquiry) rated pull-in reset nominal resistance voltage voltage voltage current Ohm tolerance VDC at 0 C at 0 C ma at 0 C % 9,6 0,6 04 5 +/-0 4 9,, 50,0 480 +/-0 48 38,4,4 5,9 850 +/-0 0 88,0 5,5, 9'000 +/-5 0 76,0 7,58 9'000 +/-5 standard coils for alternated current (other voltages on enquiry) VAC 9,6 0,6 3,3 +/-0 4 9,, 04 5 +/-0 48 38,4,4 55 40 +/-0 0 88,0 5,5 3 '0 +/-0 0 76,0,0 4'450 +/-0 30 84,5,5 5'600 +/-0 catalog 00 e / 04.03

SKR-contact specifications AgCuNi single contact current (A) 0 8 6 4 3 0,8 0,6 0,4 0,3 0, load limit curve for DC 0, 0 50 00 50 00 50 voltage (VDC) ) inductive load, L/R 40 ms ) resitive load data valid for relay SKR 085 SKR 5 SKR contact material AgCuNi (Ag,88 Ni0,) contact type single contact nominal switching capacity 50 VAC 0 A AC 500 VA 440 VAC 4 A AC 600 VA electric life expectancy app. 700'000 operations 50 VAC 0 A AC (360 operations/h) max. inrush current 40 A for 0 ms switching current range 30 ma to 0 A switching power range 0,8 VA to 500 VA contact resistance 0 mω contact life time 8 7 number of operations 6 5 4 3 0 6 3 4 5 6 7 8 9 0 A switching current (A) - AC load cos phi (AC) - 50 VAC 50 Hz 360 operations/h AgCuNi double contact current (A) 0 8 6 4 3 0,8 0,6 0,4 0,3 0, load limit curve for DC 0, 0 50 00 50 00 50 voltage (VDC) ) inductive load, L/R 40 ms ) resitive load data valid for relay contact material contact type nominal switching capacity electric life expectancy max. inrush current switching current range switching power range contact resistance SKR 085D SKR 5D SKR D AgCuNi (Ag,88 Ni0,) double contact 50 VAC 6 A AC 500 VA app. 50'000 operations 50 VAC 6 A AC (360 operations/h) 5 A für 0 ms 0 ma to 6 A 0,06 VA to 500 VA 0 mω contact life time 8 7 number of operations 6 5 4 3 0 5 3 4 5 6 7 8 switching current (A) - AC load cos phi (AC) - 50 VAC 50 Hz 360 operations/h catalog 00 e / 04.03

ZKR-PCB socket with accessories ZKR 003 matching to SKR order numbers ZKR 003 general data nominal data max. 0 A 400 V test voltage 000 Veff contact spring material Ms improved fixing soldering pin x M3 creeping resistance CTI 50 weight app. 7 g installation situation any ambient temperature -40 to +85 C number of poles -pole protection standard IP 30 accessories tests, instructions metal clamp ZKR 008 certificates insulation group UL, CSA VDE 00 / group C 50 VAC dimensions drilling plan 0,6 0,6 3,5,0x0,3 37 5,4 38,5,5 /,54,3 5,4 37 7,6 5,08 30,48 38,5 view from solder side catalog 00 e / 04.03 3

SKR-screw socket with accessories socket ZVE8 ZKE088 data nominal data 400 VAC 0 A 400 VAC 0 A dimensions (L x B x H) [mm] 57 x 38 x 8,5 75 x 38 x 6 ambient temperature [ C] -40 to +85-40 to +85 accessories plug-in modules E... time module STM 00 metal clamp ZKR008 ZKR008 ZVE ZKX8 ZKE8 data nominal data 400 VAC 0 A 400 VAC 0 A 400 VAC 0 A dimensions (L x B x H) [mm] 57 x 38 x 8,5 6 x 38 x 6 75 x 38 x 6 ambient temperature [ C] -40 to +85-40 to +85-40 to +85 accessories plug-in modules E... time modules STM 00 metal clamp ZKR008 ZKR008 ZKR008 tests, instructions certificates insulation group UL, CSA VDE 00 / group C 50 VAC 4 catalog 00 e / 04.03

time modules STM 00 data compatible to socket function time range rated voltage ZKE088/8 programmable 0,05s - 40h 4-40 VDC/VAC general data time range 8 ranges: s, 0s, m, 0m, h, 0h, d, 0d time adjustment variable, 5% - 00% of the time range time function 8 functions, selectable by DIP switches display green LED for ON-status, blinking at time delay dimensions B x H x T = 35 x 46,7 x 0,3 mm (without clamp) weight app. 4 g permissible ambient temperature -5 to +55 C nominal voltage 4V to 40V AC (-5%...+0%), 4V to 50V DC (-5%...+0%) frequency 48 Hz to 63 Hz max. power consumption 4V AC/DC: 70mW, 40V AC/DC: 700mW min. impulse time (B) AC: 50ms, DC: 30 ms min. pause time (B) AC&DC: 00ms at 5 C, AC&DC: 40ms at 55 C pull-in delay AC: max. 40ms, DC: 0ms reset time delay AC&DC: max. 00ms at 5 C, AC&DC: max. 40ms at 55 C control voltage 4V: min. 80% of supply voltage 30V: min. 95% of supply voltage time delay after power loss max. 0ms start-up time 60ms re-readiness time max. 00ms at 5 C, max. 50ms at 55 C reset at UN 0Veff precision at the scale stops ±0,5% repeatability <0,5% or 5ms (in % from scale value) accuracy in adjustment 5% temperature influence 0,0% / C voltage influence 0,00% / V max. load current 00mA at 5 C plug-in modules E... data compatible to socket ZKE088/8 free wheel diode 6-0 VDC E RC-circuit 0-30 VAC E 5C varistor 6-4 VAC E 7 varistor 6-30 VAC E 8 LED 4-60 VDC/ VAC E 6EV LED 0-30 VDC/ VAC E 9V catalog 00 e / 04.03 5