81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing



Similar documents
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Selecting RJ Bandwidth in EZJIT Plus Software

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Agilent Measuring Noninsertable Devices

Improving Chromatic Dispersion and PMD Measurement Accuracy

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

Agilent E6832A W-CDMA Calibration Application

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

The Next Generation in Automated Oscilloscope Test

Agilent U2000 Series USB Power Sensors

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

Agilent E5100A Network Analyzer

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent Technologies 3000 Series Oscilloscopes

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent 8753ET/8753ES Network Analyzers

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

DDR Memory Overview, Development Cycle, and Challenges

Agilent U2000 Series USB Power Sensors

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent Television Power Consumption Testing. Application Note

802.11ac Power Measurement and Timing Analysis

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Evaluating Oscilloscope Bandwidths for Your Application

Agilent 4338B Milliohm Meter

Agilent Testing Push-to-talk Over Cellular. Application Note

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

TI GPS PPS Timing Application Note

Agilent 8509C Lightwave Polarization Analyzer

PCI Express 1.0 (2.5 GT/s) Protocol Test

Jitter Transfer Functions in Minutes

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

Communicate with Test Instruments Over LAN Using Visual Basic

Wireless Connectivity Testing

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Eye Doctor II Advanced Signal Integrity Tools

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Multi-Range Programmable DC Power Supplies 9115 Series

Module 13 : Measurements on Fiber Optic Systems

Electrical Compliance Test Specification SuperSpeed Universal Serial Bus

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

Agilent U2000 Series USB Power Sensors

Agilent E5063A ENA Series Network Analyzer

Signal Types and Terminations

High-Speed Inter Connect (HSIC) Solution

Creating Datalogging Applications in Microsoft Excel

Electrical Compliance Test Specification SuperSpeed Universal Serial Bus

Agilent 8904A Multifunction Synthesizer dc to 600 khz

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent 4339B/4349B High Resistance Meters

Agilent 87421A/87422A Power Supply

Agilent Balanced Measurement Example: Differential Amplifiers

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity

Agilent 8720 Family Microwave Vector Network Analyzers

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Adding Heart to Your Technology

High-Speed Gigabit Data Transmission Across Various Cable Media at Various Lengths and Data Rate

Microwave Multiplexer Module

U1602A Handheld Oscilloscopes, 20 MHz

Balun Parameter Definitions & Measurement May 2004

11. High-Speed Differential Interfaces in Cyclone II Devices

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

A Lesson on Digital Clocks, One Shots and Counters

A Lesson on Digital Clocks, One Shots and Counters

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

DM54161 DM74161 DM74163 Synchronous 4-Bit Counters

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Application Note. Line Card Redundancy Design With the XRT83SL38 T1/E1 SH/LH LIU ICs

54LS169 DM54LS169A DM74LS169A Synchronous 4-Bit Up Down Binary Counter

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Agilent N4010A Wireless Connectivity Test Set

54191 DM54191 DM74191 Synchronous Up Down 4-Bit Binary Counter with Mode Control

DAC Digital To Analog Converter

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

CHAPTER 11: Flip Flops

Transcription:

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing Application Note

Introduction Industry sectors including computer and components, aerospace defense and education all require precise one or two channel signal sources. In typical measurement setups, the Agilent Technologies Pulse Pattern Generators are often used as reference clocks, system trigger or simply as data stimulus for transceiver tests. The analyzing is covered by Mixed-Signal Oscilloscopes (MSO), Digital-Signal Oscilloscopes (DSO) or Logic Analyzers. Noise, jitter, crosstalk and reflections can cause distortions so valid clocks are not seen, spikes are mistaken for valid clocks or data is misinterpreted. Such effects cause system failures and must be minimized in the design to ensure accurate and reliable operation. Therefore, devices need to be stressed with these kinds of distortion during design, validation and production. The essential features for measurement equipment to create the correct test conditions are two output channels, with channel adding, programmable patterns, and adjustable delays and transitions. The Agilent Technologies 81104A (80 MHz) and 81110A Pulse Pattern Generators meet all of these conditions, with the 81110A having the further flexibility of either Agilent Technologies 81111A (165 MHz) or 81112A (330 MHz) Output Channels. This application note describes how to use the 81110A To create distorted signals To inject noise for full stress testing of devices Figure 1: The setup of an Agilent Pulse Generator and an Agilent Infiniium oscilloscope Page 2

Producing Distorted Signals Principle of distorted signals As shown in Figure 2, perfect data or clock signals are defined by their rising and falling edges, the width and the delay of the pulse. The width and delay are defined at the 50 % points of the edges. An ideal pulse pattern generator lets the user define each of these parameters individually. Figure 3: Distorted signal composed from two independent patterns Figure 2: Perfect and distorted signal with clean rising and falling edges A distorted signal has either positive or negative spikes added to the perfect signal at a specific place. With the 81110A it is possible to create such distorted signals by adding two pulse signals. The first one is a perfect pulse, the second reflects the distortion. This is why it is necessary to have a pulse pattern generator with two channels that can be added together. Also, the pattern needs to be programmable and the delay and transition of the rising and falling edges need to be adjustable. In Figure 3, we show how to define and combine the signals from each channel. The first channel has the perfect signal, including the logic patterns. On the second output channel, we define the spikes. These can be either positive or negative. Adding the two (that is the perfect signal and one of the spikes) we get the distorted signal. Page 3

Setting Up the Pulse Pattern Generator Figure 1 shows the setup used for the following measurements. In this section we show the four easy steps to set up the pulse pattern generator. This is, defining the pattern mode, entering the pattern, defining the pulse timing and finally, setting the signal levels. You can enter the parameters using either the front panel or SCPI programming. Step Two: 2.1 Press PATTERN, and then set up the following pattern for each channel. Step One: 1.1 Reset the instrument by selecting RECALL+0 (SHIFT, STORE+0). 1.2 Press MODE/TRG, and then select the PATTERN mode. Step Two (a): Parameters set in the PATTERN menu 2.2 Press PATTERN again and the pulse pattern generator shows the waveform for each channel. Step One: Parameters set in the MODE/ TRG menu Step Two (b): The signal pattern Page 4

Step Three: 3.1 Press TIMING. 3.2 Set up the perfect signal with rising and falling edges of 5 ns, a pulse width of 20 ns and a frequency of 30 MHz. 3.3 Set up the spike with rising and falling edges of 2 ns, a pulse width of 5 ns. For a negative spike, set a delay of 8 ns. For a positive spike, set a delay of 25 ns. Step Four: Finally, define the voltage levels. 4.1 Press LEVELS. 4.2 Set up the perfect signal for a high level of 2.5 V. 4.3 For a negative spike, set the high level to 0 V and the low level to - 800 mv. Select COMPLEMENT mode. For a positive spike, set the high level to 1 V and the low level to 0 V. Select NORAMAL mode. 4.4 Finally, select that channel 2 (with the spike) is added at output 1. Step Three: Parameters set in the TIMING menu for the perfect signal and a negative spike Step Four: Parameters set in the LEVELS menu for the perfect signal and a negative spike Page 5

Examining the Output Signal The two following screen shots (made with an Agilent oscilloscope) show the resulting distorted signal. The pulse width of the positive spike is long when compared with the negative spike. Varying the delay, moves the spike forwards and backwards. If the delay of the positive spike is reduced, the spike merges with the perfect signal and creates a "multilevel signal". Figure 4: Distorted signal with a negative spike Please Note: Though the timing system of the 81110A has a frequency up to 330 MHz, the 81111A output channel has a maximum frequency of 165 MHz. If you set the frequency of an 81111A channel to 330 MHz, you will receive a warning. This over-programming is not critical, but means the specifications are no longer guaranteed. Injecting Noise Devices can and need to be stressed in different ways by applying distorted signals, jitter or noise. For low speed applications, analyzing the behavior under common mode or differential noise conditions is the second important test. Common mode noise means the same noise signal is on both the data and the data complement line. Differential (also known as cross-talk) noise means the noise is on one data line only. Noise is added as AM (amplitude modulation) to the data sequence. Using a function generator this noise can be sinusoidal, rectangular or random. For the high-speed data, the AM is achieved by connecting to the terminating resistors. By applying the modulating signal to the far side of the terminating resistors, normally the ground, this signal is added to the data sequence at the receiver (RX) input. Figure 6 shows the set up for noise injection. The pattern generator provides the data sequence on the differential lines. A power divider is included into both signal lines to add the modulation signal. This must be done in a way that keeps the electrical length of both data lines, between generator output and receiver input, the same. For the measurement, we connect an oscilloscope (as shown in Figure 1.0) instead of the device under test (DUT) in Figure 6. Configure one output channel of the pulse pattern generator (81110A) (either an 81111A, 165 MHz channel or an 330 MHz 81110A channel) is enough. To stress the DUT with noise, the pulse pattern generator creates a simple pattern - for channel 1 and the strobe, as shown in steps 1 to 3 above. The power dividers use three resistors to ensure proper termination in each direction, though this means an amplitude loss of 50 % through the divider. For a specific swing, we need to double the amplitude on the pattern generator. Figure 5: Distorted signal with a positive spike Page 6

Figure 6: Test setup for noise testing with an 81110A/11A and Agilent Technologies 33250A Function Generator For common mode noise we need to modulate both data lines with the same signal. Therefore we also need a power divider to split the noise from the function generator. This will provide the noise signal on both data lines with clean isolation of the data and data complement lines. To compensate for the modulation signals passing through two power dividers, the amplitude of the function generator must be set to 4-times the desired noise floor at the receiver input. Figure 7 shows the principal influence of common mode noise on a signal. The injected noise causes a voltage range on the high and low levels of the signal. Jitter, on the other hand, would result in increasing the width of the rising and falling edges. For differential noise, we only need to connect the modulation signal to one of the power dividers in the data path. In this case, it is important to terminate both open ends. Some function generators may not have a good backwards termination, so it may be helpful to add a 3dB attenuator between the function generator and the power divider. This improves backwards termination significantly. Figure 7: Influence of noise on the eye diagram Page 7

Related Literature Publication Number www.agilent.com Pulse Pattern and Data Generators Digital Stimulus Solutions, Brochure 5980-0489EN 81100 Family of Pulse Pattern Generators 5980-1215E Technical Specifications 81100 Family of Pulse Pattern Generators 5968-5843E Radar Distance Test to Airborne Planes Product Note 1 81100 Family of Pulse Pattern Generators 5968-5844E The Dual Clock Gbit Chip Test Product Note 2 81100 Family of Pulse Pattern Generators 5968-5845E Magneto-Optical Disk Drive Research Product Note 3 Infiniium 54850 Series Oscilloscopes 5988-7976E Data sheet Signal Integrity Solutions Brochure Function/Arbitrary Waveform Generator Data Sheet 5988-5405EN 5968-8807EN www.agilent.com/find/81100family_81110a Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Product specifications and descriptions in this document subject to change without notice. For the most up-to-date version of this document, please visit our website at www.agilent.com/find/81100family_81110a and go to the Key Library Information area or insert the publication number (5989-4709EN) into the search engine. Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. United States: Korea: (tel) 800 829 4444 (tel) (080) 769 0800 (fax) 800 829 4433 (fax) (080)769 0900 Canada: Latin America: (tel) 877 894 4414 (tel) (305) 269 7500 (fax) 800 746 4866 Taiwan: China: (tel) 0800 047 866 (tel) 800 810 0189 (fax) 0800 286 331 (fax) 800 820 2816 Other Asia Pacific Europe: Countries: (tel) 31 20 547 2111 (tel) (65) 6375 8100 Japan: (fax) (65) 6755 0042 (tel) (81) 426 56 7832 Email: tm_ap@agilent.com (fax) (81) 426 56 7840 Contacts revised: 05/27/05 For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2006 Printed in USA, 1 June, 2006 5989-4709EN