Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet



Similar documents
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

HP UPS R1500 Generation 3

IO-RM3 3-Stage Relay Module

Modular I/O System Analog and Digital Interface Modules

Voltage Regulator SPAU 341 C. Product Guide

LIEBERT VNSA Installation Sheet

Square D Clipsal C-Bus Network Analyzer

BITMAIN. APW PSU Series User Guide

G670 Intermittent Pilot Ignition Controls

Quick Connect. quick - simple - efficient.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Current Monitoring Kit

connecdim Gateway G1 Ethernet TCP/IP to DALI

MCR1900 Media Converter 19-Slot Chassis

ST Series POWER SUPPLIES USER INSTRUCTIONS

PowerLogic Sub Meter Display (SMD and SMDOPN)

HP R12000 and R18000 DirectFlow UPS User Guide

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Remote Monitoring and REC 501 Control Unit Product Guide

SYSTEM DESCRIPTION Termination Boards

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Model: DC-A2IO Advanced HVAC Controller

RM4TG20 three-phase network control relay RM4-T - range V

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

R.C.C.B. s two-pole LEXIC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

3500/93 System Display

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Emergency lighting units EM powerled

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Product and functional description

49 Series - Relay interface modules A. Features

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

instabus KNX / EIB System System E F G H

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Application Technique. Safety Function: Magnetic Door Switch Monitoring

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

T Substation Maintenance and Commissioning Test Equipment

Application/Connection Examples

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Current Monitoring Kit QUICK START GUIDE

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

PCS0100en Persy Control Services B.V. Netherlands

HMI display Installation Guide

HP Port Switches Quick Setup Guide

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

L5354 ControlNet Communications Interface

Uninterruptible Power Supply

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Cross-beam scanning system to detect slim objects. 100 mm in

mecotron Safety relay ESTOP-2 For emergency stop monitoring

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

48 SERIES Relay interface modules 10 A

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Online UPS. PowerWalker VFI 1000R/1U

Safety technique. Emergency stop module BO 5988 safemaster

Solid State Timers Type F

ACS-30-EU-EMDR-10-MOD

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

HM-W536 Install Guide

MultiVOIP FX SIP Gateways

CompactLogix Power Supplies Specifications

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

2008 Eaton Corporation. All rights reserved.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

HotSwap MBP Maintenance Bypass

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Technical Note Series

TrueAlarm Fire Alarm Systems

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Ensto Chago Master EVM300 and EVM500 Operational description

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DLP-PU/E Instruction Manual

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Installation and Operation Back-UPS 1250, 1300, 1500

PSR The compact range Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TOA 900 SERIES II MIXER POWER AMPLIFIER

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Back-UPS Pro 1300/1500 Installation and Operation

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Single Channel Loop Detector

Transcription:

Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical workers should install this equipment, after reading this entire instruction set. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that all circuits are live until they have been completely deenergized, tested, and tagged. Terminal 17 (PE) on connector A of the MCS025 and the functional grounding terminal of the Sepam Series 80 relay must be locally connected to the cubicle grounding circuit. The two connection points must be as close as possible to one another. Dangerous voltages may be present on the terminal screws. Tighten all terminal screws so that they cannot be touched inadvertently. Use a properly rated voltage sensing device to confim that power is off. Replace all devices, doors, and covers before energizing the equipment. Failure to follow these instructions will result in death or serious injury. Introduction The optional MCS025 module performs the Sepam Series 80 sync-check function (i.e., checks the upstream and downstream voltages of a circuit breaker to ensure safe closing ANSI 25) for substation, transformer, generator and bus applications. It checks the differences in amplitude, frequency, and phase between the two measured voltages, and takes into account dead line/bus conditions. Three relay outputs can be used to send a Close Enable signal to several Sepam Series 80 relays. The circuit-breaker control function of each Sepam Series 80 relay takes this close enable into account. The settings for the sync-check function and the measurements carried out by the module are accessed by the SFT2841 setting and operating software. They are similar to the other settings and measurements for the Sepam Series 80. The MCS025 module is equipped with the following: CCA620 connector for connecting the relay outputs and the power supply CCT640 connector for voltage connection CCA785 cord for connection between the module and the Sepam Series 80 base unit 1

MCS025 Sync-Check Module 63230-216-244B1 Storage Identification Commercial Name Description Reference # Serial # 51312294FA-A0-01 For storage, keep the MCS025 module in its original packaging in a sheltered location with the following environmental conditions: Ambient temperature -13 to +160 F (or -25 to +70 C) Non-condensing humidity 90% Each MCS025 module is delivered in a separate package containing: 1 MCS025 Sync Check Module 1 CCT640 VT Voltage Connector 1 CCA785 Sync Check Connection Cable 1 Installation Sheet To identify an MCS025 module, check the label on the connector side of the MCS025. NOTE: For further information, please see the Sepam Series 80 Installation Manual (63230-216-229). 2 2007 Schneider Electric. All Rights Reserved.

63230-216-244B1 MCS025 Sync-Check Module Characteristics MCS025 Module Weight 2.98 lb (1.35 kg) Assembly With the AMT840 accessory (must be ordered separately) Operating Temperature -13 to +158 F (-25 to +70 C) Environmental Characteristics Same characteristics as Sepam base units Voltage Inputs Input Impedance > 100 kù Burden < 0.015 VA (VT 100 V) Continuous Thermal Withstand 240 V One-Second Overload 480 V Relay Outputs Relay Outputs O1 & O2 Voltage DC 24/48 V DC 127 V DC 250 V DC AC (47.5 63 Hz) 100 240 V AC Continuous Current 8 A 8 A 8 A 8 A Resistive Load 8 A / 4 A 0.7 A 0.3 A Load L/R < 20 ms 6 A / 2 A 0.5 A 0.2 A Breaking Capacity Load L/R < 40 ms 4 A / 1 A 0.2 A 0.1 A Resistive Load 8 A Load p.f. > 0.3 5 A Making Capacity < 30 A for 200 ms Isolation of outputs from other isolated groups Enhanced Relay Outputs O3 & O4 (O4 Not Used) Voltage DC 24 / 48 V DC 127 V DC 250 V DC AC (47.5 63 Hz) 100 240 V AC Continuous Current 2 A 2 A 2 A 2 A Breaking Capacity Load L/R < 20 ms 2 A / 1 A 0.5 A 0.15 A Load p.f. > 0.3 5 A Isolation of Outputs from other Iisolated Groups Enhanced Power Supply Voltage 24 250 V DC, -20 % / +10% 110 240 V AC, -20% / +10% 47.5 63 Hz Maximum Burden 6 W 9 VA Inrush Current < 10 A for 10 ms < 15 A for one half period 2007 Schneider Electric. All Rights Reserved. 3

MCS025 Sync-Check Module 63230-216-244B1 Connection to Sepam Series 80 The MCS025 module can only be connected in the last position of a sequence of Sepam series 80 remote modules. Connect the MCS025 module at the end of the sequence with the included CCA785 cord. A B C VT VT Sync-Check ANSI 25 I/O Mod Connector Type Reference Wiring A Screw-type CCA620 Wiring with No Fittings: One wire with a maximum cross-section of > AWG 24 12 (0.2 2.5 mm²) Two wires with cross-sections of >AWG 24 16 (0.2 1 mm²) Stripped length: 8 10 mm Wiring with Fittings: Recommended wiring with Telemecanique fittings: B Screw-type CCT640 DZ5CE015D for one 1.5 mm² wire DZ5CE025D for one 2.5 mm² wire AZ5DE010D for two 1 mm² wires Wire length: 8.2 mm Stripped length: 8 mm D Orange RJ45 connector CCA785, special prefabricated cable supplied with the MCS025 module: Orange RJ45 connector for connection to port D on the MCS025 module Black RJ45 connector for connection to the Sepam Series 80 base unit, either directly or via another remote module 4 2007 Schneider Electric. All Rights Reserved.

63230-216-244B1 MCS025 Sync-Check Module Description 1. MCS025 module A. CCA620 20-pin connector for: Auxiliary power supply 4 relay outputs: O1, O2, O3: close enable O4: not used B. CCT640 connector (phase-to-neutral or phase-to-phase) for the two input voltages to be synchronized C. RJ45 connector, not used D. RJ45 connector for module connection to the Sepam Series 80 base unit, either directly or via another remote module 2. Two mounting clips 3. Two holding pins for the flush-mount position 4. CCA785 connection cord 1 2 B A D C 3 4 Mounting 202 ± 0.2 162 ± 0.2 The MCS025 module can be flush-mounted and clamped, without requiring any additionnal screw type fastening. 1. Position the module as shown, ensure the metal plate is correctly seated in the groove at the bottom. 2. Tilt the module in as shown and press the top until it is held in place by the mounting clips. 1 The MCS025 module can be mounted at the back of the compartment using the AMT840 mounting plate (to be ordered separately). 2 Slot CCT640 Mounting Clip 6.5 40 40 202 40 230 123 162 40 40 15 216 236 10 2007 Schneider Electric. All Rights Reserved. 5

MCS025 Sync-Check Module 63230-216-244B1 Energizing Figure 1: "Wrench" LED The supply voltage must be between 24 250 V DC. After the MCS025 module is switched on, it performs the following initialization sequence, which takes approximately five seconds: 1. ON and "Wrench" LED (see Figure 1) illuminate 2. "Wrench" LED dims At the end of the initialization sequence, the "Wrench" LED should be OFF. Diagnosis If the "Wrench" LED is still illuminated after the initialization sequence has completed, refer to the instructions below: Wrench LED is Flashing If the Wrench LED is flashing, then a minor fault has been detected and the MCS025 module is automatically put into downgraded operation mode. Check the connection of the module to the base unit via the orange RJ45 connector Confirm that the MSC025 module has been configured as a remote module of the base unit using the SFT2841 software Wrench LED is Steadily Illuminated If the Wrench LED is steadily illuminated, then a major fault has been detected and the MCS025 module is automatically put into fail-safe mode. Check the connection (DPC, detection of plugged connector function) NOTE: If after performing the procedures above the "Wrench" LED is still illuminated, refer to the "Maintenance" chapter of the Sepam Series 80 Installation Manual (63230-216-229). Parameter Setting with SFT2841 Set the MCS025 module parameters and sync-check functions with the SFT2841 software, in the same manner as other Sepam Series 80 relay parameter and protection settings. NOTE: Do not connect the SFT2841 directly to the MCS025 module. Operation All operating data prepared by the MCS025 module measurements, indications, and diagnosis are available from the SFT2841 software in the same manner as all other Sepam Series 80 relay operating data. 6 2007 Schneider Electric. All Rights Reserved.

63230-216-244B1 MCS025 Sync-Check Module 2007 Schneider Electric. All Rights Reserved. 7

MCS025 Sync-Check Module 63230-216-244B1 Instruction Bulletin Schneider Electric USA 295 Techpark Drive, Suite 100 LaVergne, TN 37086 USA 1-888-SquareD (1-888-778-2733) www.us.squared.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2007 Schneider Electric. All Rights Reserved.