Harris IRT Enterprises Digital Resistance Tester Model 5060-06XR



Similar documents
LDG DTS-4/4R Desktop Coaxial Switch / Remote

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

DPI 260 SERIES: Digital Pressure Indicators

DISCONTINUED. AtlasScientific. as of 10/21/13. E.C. Circuit. Biology Technology. Features

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

F2400 FOM II Series Fiber Optic Modem Technical Manual

Product Information Sheet UH28CS-12kV Hi Pot Tester

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

LDG DTS-6/6R Desktop Coaxial Switch / Remote

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Digital and Analog I/O

MANUAL PC1000R

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

Instruction Manual RCI-800-XXX. Remote Control Signal Interface

User's Guide. Integrating Sound Level Datalogger. Model Introduction

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Essential Electrical Concepts

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

IO-DIM6 6-Channel, Digital to Analogue Converters

Conversion Between Analog and Digital Signals

Temperature & Humidity SMS Alert Controller

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Sierra S-Series Smart Interface Software User Manual

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Low Cost, Precision IC Temperature Transducer AD592*

Physical Specifications (Custom design available.)

Kit Watt Audio Amplifier

SYSTEM 4C. C R H Electronics Design

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

IRT Eurocard. Types DAX-3200

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

TC-9102 Series Surface Mount Temperature Controllers

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PERF10 Rubidium Atomic Clock

Research RF Sputtering Packages

AutoRanging Digital MultiMeter

Dashboard Digital Voltmeter

1. SAFETY INFORMATION

Manual Ranging MultiMeter

Model SRMD Setra Remote Monitoring Display

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Polyphase kwh Electricity Meter

INSTALLATION & SERVICE MANUAL. Display Panel

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

C220 PRELIMINARY TUBE PREAMPLIFIER SERVICE MANUAL. SERIAL NO. WS1001 And Above C220. Serial Number W S1001 And Above CONTENTS

OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC WattsVIEWTM. Models: DC Serial DC-1000 USB DC-25000

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Modular I/O System Analog and Digital Interface Modules

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Advantium 2 Plus Alarm

User Guide. Temperature and Humidity Datalogger. Model 42280

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Bluetooth UART/RS232 Module

Voltech DC1000. Precision DC Bias Current Source

Contents. Document information

PS 155 WIRELESS INTERCOM USER MANUAL

Instruction Manual. RCI-400-XXX Remote Control Signal Interface

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Installation and Operation Back-UPS 1250, 1300, 1500

Troubleshooting and Diagnostics

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

SX460. Generator Automatic Voltage Regulator Operation Manual

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

MP-4000 Alarm List (Software version or later)

How To Use A Cdm250 Digital Multimeter

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Current Monitoring Kit

MASTERSOUND. M a s t e r E m o t i o n. PF 100 Limited. Made in Italy

EMBEDDED ACCESS CONTROL Hardware Installation Guide

LOXONE 12 Channel Amplifier

Part Number Description Packages available

Single Station Remote Alarm

F(t) Forssell Technologies Inc

NortechCommander Software Operating Manual MAN R6

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

Transcription:

Harris IRT Enterprises Digital Resistance Tester Model 5060-06XR Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options 8 RS-232 Configuration 9 Temperature Compensation Option 10 Temperature Compensation Calibration 11 Trouble Shooting Hints 12 Return Policy 13 Warranty 13 Assembly Drawings 14

SPECIFICATIONS ACCURACY (% FULL SCALE) RANGES DISPLAY READING RATE TERMINALS POWER REQUIREMENTS TEST CONNECTIONS CONNECTORS LIMIT ALARM TERMINALS ±0.05% (Includes +/- 1 digit) at 25 C ±0.001% per C from 0 to 70 C 0 to 1.999, 19.99, 199.9, 1.999K, 19.99K, 199.9K Milliohms 3 ½ digit LED Display and 4 ½ Digit RS-232 Output 4 readings per second (minimum) Max. Full-scale voltage is 2.0 Volts and less than 1000 ma. Current 117 VAC +/- 10 %, 50-60 Hz, 5 Watts. 2 amp Slo-Blo fuse (230 VAC optional) 4 wire Kelvin required Rear panel MS-style circular connector and front panel banana jacks Dry contacts rated at 2A. At 117 VAC DIMENSIONS 2

THEORY of OPERATION The Harris IRT Enterprises Model 5060-06XR Resistance Tester is a digital ohmmeter that includes a precision constant current source which drives a known current through an unknown resistance. It features four readings per second and a temperature compensated voltage reference serving both the DVM and the constant current source. This results in a stable calibration reference. The voltage drop across the unknown resistance is amplified by a chopper stabilized preamplifier. This amplified signal is then sent to a digital voltmeter and presents a digital display of the resistance in Milliohms. The 16F877 Microprocessor based circuit includes a dual limit comparator which compares the measured resistance with upper and lower tolerance values entered on front panel thumbwheels. Red and green front panel light emitting diodes indicate whether or not the resistance is within tolerance. An output relay permits the resistance tester to be converted to a rejection device. For fail-safe operation the contacts are normally open. The contacts close if the part is within tolerance. The Microprocessor based circuit also provides for electronic range switching and system control. BLOCK DIAGRAM 3

OPERATION of UNIT FRONT PANEL VIEW: 4

REAR PANEL VIEW: TEST CONNECTIONS: NOTE: 5

For greatest accuracy each voltage and current lead must connect separately to the component under test. This is most critical in low resistance measurements. I + V + FRONT PANEL BANANA JACKS UNKNOWN RESISTANCE I - V - B F E A C I + v + v - I - UNKNOWN RESISTANCE D REAR PANEL CIRCULAR CONNECTOR N. O. RELAY CLOSED FOR GOOD PART 5060-06XP CALIBRATION PROCEDURE REQUIRED EQUIPMENT: A digital voltmeter with a 4½ digit resolution and a 200 millivolt full scale range is required. You will need a set of six standard resistances, one for each range to be calibrated. A precision of at least 0.02% is necessary to calibrate this instrument to specifications. Harris IRT Enterprises can supply a 0.02% resistance set, Model 2005, with standard resistances and switchable Kelvin connections. Recommended standard resistance 1.9900 Milliohms (.00199 Ohms) 19.900 Milliohms 6

199.00 Milliohms 1.9900 Ohms (1.99K Milliohms) 19.900 Ohms 199.00 Ohms NOTE: The resistances must be just below the full scale value of each range. It is important to check the instrument calibration before attempting any adjustments. The Calibration check procedure is listed below. A suitable set of 4-wire Kelvin test leads will be required for connecting the standard resistances to the instrument. Either the front panel jacks or the rear panel MS- Style connector may be used for the Kelvin test leads. Calibration Check: Turn Power On to the instrument and allow a five minute warm-up time before checking calibration. Be certain that temperature compensation switch is turned to the OFF position while checking calibration or adjusting calibration. Check each range using a certified standard value near full scale for the range being checked. All readings must be within 2 counts of the certified value near full scale. Next check all ranges at 10% of full scale using the certified standard for the next lower range. Again the readings must be within 2 counts of the certified value. Note that 1 additional digit of dither is permitted by the specifications. If the instrument meets these specifications on all ranges, do not perform a calibration procedure. You will eventually wear out the adjustment potentiometers. If all of the ranges require major adjustment, there is likely a component failure or some problem in the test setup. Caution: Never select the 2 Milliohm Range with any standard but the 1.99 Milliohm connected to the 5060. The 1 Amp current can easily damage the other standard resistors. Calibration Procedure: Note: Adjustment locations are shown on the next page. 1. Connect the Kelvin Test leads as follows: Tightly twist and solder together the four wires from the E+, E-, and I- terminals. Select the 0.2-Milliohm range Since the Chopper Stabilized Preamp automatically zeros between readings, the display should read close to 0.000 Milliohms. It is however, very difficult to make a true zero Ohm connection. 2. Connect a 199.00-Ohm standard to the four wire Kelvin test leads and select the 200K Milliohm range. Connect a 4 ½-Digit voltmeter across the standard resistor and adjust the potentiometer marked I x 1 until a voltage of 0.1990-V is indicated on the voltmeter. You may also adjust the potentiometer marked 100μA if more range is needed. With the external voltmeter removed, the 5060 display should be within a percent or so of the correct reading at this point. The I x 1 control can be used to bring the ohmmeter reading to the exact value of the standard resistor used 3. Connect the 19.900-Ohm standard and select the 20K-Milliohmhm Range. Adjust the E x 10 control until the certified value is displayed on the Ohmmeter. 4. Connect the 1.9900-Ohm standard resistor and select the 2K-Milliohm range. Adjust the control marked 1 ma until the Ohmmeter display indicates the certified value of this standard. 5. Connect the 0.1990-Ohm standard resistor to the Kelvin test leads and select the 200-Milliohm range. Adjust the 10 ma potentiometer until the certified value is displayed. 7

6. Connect the 19.900-Milliohm standard and select the 20 Milliohm range. Adjust the 100 ma potentiometer until the proper resistance value is displayed 7. Connect the 1.990 Milliohm (0.00199 Ohm) standard and select the 2.0 Milliohm range. Adjust the 1000 ma potentiometer until the Display indicates the certified resistance value. 8. Perform a complete calibration check as described at the beginning of this procedure. Your calibration should now be within factory specifications. An annual calibration check is recommended to keep your instrument within specifications. 5060-06XR Component and Adjustment Locations: OPTIONS TEMPERATURE COMPENSATION ( TC ): Temperature changes of a few degrees in a product can have significant effects on the product s resistance. Therefore, the need for temperature compensation may arise when the temperature of the part being tested changes over a period of time. The benefits of temperature compensation include the saving of time, energy, and money by eliminating the need to refer to coefficient tables as the ambient plant temperature varies during the day. Before now, such compensation was available only in expensive and delicate laboratory-grade instruments. Harris IRT has now made it available in rugged resistance testers designed for use in production. 8

With temperature compensation, a probe sends ambient temperature data to the instrument. This temperature information is used to modify the constant current that is being passed through the part under test. The resistance then registered is the resistance the item under test would have at the specified temperature. The compensation option can be calibrated for the measurement of either of two measurement coefficients or it can be operated without any compensation. The accuracy of the compensation is within 0.2 % of the actual resistance between 0 and 50 C. BINARY CODED DECIMAL ( BCD ): BCD is not available on the portable XP Series Ohmmeters. It is available in the Rack Mount XR series cases. The BCD output allows the resistance tester to transmit readings to a Programmable Logic Controller (PLC). The BCD option generates a 1, 2, 4, and 8 bit for each of the 5 characters in the resistance reading. An output strobe is also provided to allow synchronization of the resistance tester with the PLC. The BCD output is a TTL logic level of 0 to 5 VDC and a maximum output current of 24 ma. REMOTE RANGE SELECT ( RR ): The remote range select option is typically used in on-line testing when various resistances must be tested. This option allows a PLC or other controller on the production line to set the range of the resistance tester. This option is usually used in conjunction with the BCD or RS-232 options. In the new X-series of the IRT Testers the remote range selection is done through the RS-232 serial port. The serial port can also be used to externally set upper and lower limit sensors. This feature is most useful with the Test Channel Multiplex Option. SAMPLE and HOLD ( SH ): This option is available only in the Rack Mount XR series ohmmeters because of space restrictions. It permits the measurement of a component s resistance on-the-fly even though the contact time with the component is very brief (a few milliseconds). It is possible to hold a resistance reading for digital processing and display. 100 % testing is possible under such conditions. SAFETY RELAY ( RY ): When a resistance tester is used in conjunction with high pot or surge tests, an internal safety relay can be provided to lock-out the resistance tester circuitry during other testing. This will protect the resistance tester from possible high-voltage or high-current damage. Due to space requirements, this is only available in the Rack Mount cases. RS-232 COMPUTER INTERFACE ( RS232 ): A three-wire link between the resistance tester and a computer can be made through the RS-232 port. This is a standard null-modem connection with a 9600-Baud rate, and a word length of 8 bits. The default Baud rate is set to 9600 at the factory. This permits the reading shown on the front panel display to be sent to an external computer or PLC, every time the instrument receives an ASCII from the host. This interface is useful for the statistical analysis of production, predictive control, and data logging. It is compatible with any computer or PLC having an RS-232 port. Factory settings for the Serial Port: 9600 Baud, No stop bit, 8 bit word, No parity. (9600,N,8,1) Program changes can permit operation up to 56K Baud on special order. 9

NULL MODEM CONNECTIONS: The RS-232 port is usually interfaced to a computer using terminal software and responds much like a dumb terminal. For the connecting cable use a MALE DB-9 style connector wired with the following pin configuration. Function Receive ( Rx ) Pin 2 Common ( Com ) Pin 5 Transmit ( Tx ) Pin 3 Connector Pin Whenever the host computer sends any character to the RS-232 port, it will respond by returning the 5 characters plus the decimal shown in the display of the resistance tester. In the case of the Model 5012-06X- Series resistance tester, which has only a four-digit display, a six-digit character group is still sent. The fifth digit is the least significant digit. After the five-character resistance reading is sent including the decimal point, the port will stand by, waiting to receive the next character from the computer before returning the current reading. NOTE: The resistance tester does not send Start Of Text (0X02 Hex), End Of Text (0X03 Hex) or a Carriage Return (0X0D Hex). The unit simply stops sending data after the 5th digit. Special ASCII characters can be appended on a custom basis. 10

TEMPERATURE COMPENSATION PROCEDURE PRE-CALIBRATION PROCEDURE: Plug the Temperature Compensation Probe into the jack located on the rear panel. Make a coil of copper wire, approximately one Ohm in resistance, that will easily fit into your water bath containers. Make up a 4- wire Kelvin connection to the Standard coil and connect the 4 wires to the test jacks on the front panel of your Ohmmeter. Using a Voltmeter, measure the voltage between the green and gray wires on the stereo jack located on the rear panel. The measured reading should be approximately 2.73 Volts +10 mv per C. For example, the room temperature is 25 C. The voltage reading should be about 2.98 Volts. If the voltage reading is more than ±20 mv from the calculated reading or the reading is 12 V, then the TC probe is defective. Replacement TC probes can be ordered from Harris IRT Enterprises as part # -TCP. Note: TC probes are not interchangeable without re-calibration. Each Probe must be calibrated to work with its own IRT Unit. PREPARING THE WATER BATHS: Three water baths will be needed for proper calibration: One bath at the specified STANDARD temperature; a HOT bath at +20 C from the specified temperature and a COLD bath at -20 C from the specified temperature. For example, if the specified temperature is 25 C, using a Celsius thermometer prepare one bath for 25 C, a HOT bath at 45 C and a COLD bath (using ice cubes if necessary) at 5 C. It is important that enough water is used in each bath so that room temperature will not effect the temperatures of the baths before the calibration is complete. Also make sure that the STANDARD bath is EXACTLY what the standard temperature should be. Location of Temp. Comp. Adjustments CALIBRATION PROCEDURE: 1) Plug the temperature compensation probe into the rear of the resistance tester. Connect the 1- Ohm Standard coil to either the MS-connector or the Front Panel Test terminals using a 4-wire Kelvin connection. 2) Set the resistance tester to the 2-Ohm range. Make sure the temperature compensation switch located on the rear panel is in the OFF (center) position. 11

3) Place the TC probe and the resistance standard into the specified temperature bath. Stir the TC probe and the resistance standard a few times until the readings stabilize. After the display stabilizes (usually a few minutes) record the coil resistance reading. Step #3 Reading 4) Switch the temperature compensation switch to the ON position. 5) Adjust the TZ Potentiometer until the display reads the same as the recorded reading in Step #3. Place the TC probe and the resistance standard into the HOT bath. Stir the TC probe and the resistance standard a few times until the display stabilizes (usually a few minutes), adjust POT TA until the display reads the same as the recorded reading in Step #3. 6) Place the TC probe and the one Ohm standard coil into the COLD bath. Stir the TC probe and the coil standard a few times until the display stabilizes. Step #6 Reading 7) Subtract the reading from Step #6 from the recorded reading in Step #3. Divide the ANSWER by 2. Add this result to the original reading in Step #7, and record the result. Step #3 reading Step #6 reading Answer/2 = + Step #6 + Answer = Step #8 result 8) Adjust potentiometer TA until the display reads the same as the recorded result in Step #8 9) Turn the temperature compensation switch to the OFF position. The temperature compensation procedure is completed. 12

TROUBLE-SHOOTING HINTS SYMPTOM: The Resistance Testers display flashes 0000. POSSIBLE SOLUTIONS: The Resistance Tester is in over-range mode, select a higher range. The ICL7135 CPI A/D converter could be burned-out. This IC is socketed and can easily be replaced by the user 1. SYMPTOM: The Resistance Tester displays changing numbers or garbage readings. POSSIBLE SOLUTIONS: Check to make sure a load is connected to the Resistance Tester via the back panel circular connector or front panel banana plugs. While the Kelvin Connection is open circuit (I+ not connected to E+ and I_ not connected to E-) the voltage present on the Voltage input terminals will be random. Because there is a small capacitor on the input circuit, you will display any static charge that has accumulated on this capacitor. This is the normal behavior of a Kelvin input instrument. Check to make sure you have a valid 4 wire Kelvin connection. (see illustration below) SYMPTOM: Readings all appear to be incorrect. POSSIBLE SOLUTIONS: Check to see if the Temperature Compensation switch is in the proper position and that the TC probe is completely inserted into the rear panel Jack. Is the Resistance Tester is due for calibration? A calibration should be performed once a year. 1 Opening the meter to replace any IC s could void the manufacturers warranty.

Insure that the front panel I and E terminals are not connected to permit a 2-wire non-kelvin test. Although the meter accuracy will be OK on the higher ranges, this will cause severe errors on the lower resistance ranges. This will be a problem even if you are using the MS-Style connector for you Kelvin Leads. Using the 4-wire test leads but connecting them to only two pogo pins will leave the pogo pin resistance and the contact resistance in the measurement. Four individual connections must be made to the test component s terminals to get a real Kelvin connection. One or more of the OP177 op-amps could be burned-out. These IC s are socketed and can easily be replaced by the user 1. Check to make sure you have a true 4-wire Kelvin connection. NOTE: Resistance changes as temperature changes. If the ambient temperature varies during the day so will the resistance of the part under test. This could make it appear that the Resistance Tester is not working properly. You may require the use of Temperature Compensation. For Technical assistance call Harris IRT Enterprises at (740) 369-3580 RETURN POLICY NOTE: Before returning a Resistance Tester for repair or calibration you must first call and receive an RMA#. Any package received without an RMA# will be returned to shipper. Please write the RMA# on the package and packing slip. To return a Resistance Tester for repair after you receive an RMA# ship to: MANUFACTURER S WARRANTY Harris IRT Enterprises 155 Johnson Dr. Delaware, Ohio 43015 Phone: (740) 369-3580 Fax: (740) 369-2653 Equipment shall meet all engineering performance data and design requirements described in the specifications. Within a period of one year from the date of shipment, if the equipment should fail to function due to a defect in parts or workmanship, Harris IRT Enterprises, at its option, will replace or repair the equipment at its facility in Delaware, Ohio. NOTE: Removing the calibration seal and performing unauthorized repairs will void the calibration and could void the manufacturers warranty. Please call Harris IRT Enterprises before performing any repairs. 14

MODEL 5060-06XR MAIN PCB ASSEMBLY DRAWING 5012X-Series Display Board 15