±15 V Current-Limited Power Supply



Similar documents
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

How To Use A Cdm250 Digital Multimeter

Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

12-Volt 10-Amp Regulated Power Supply

Model PS-4001 Power Supply User Instructions

INSTRUCTION MANUAL MODEL PCD-88

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

PERF10 Rubidium Atomic Clock

PEDAL POWER. User s Manual

BroadBand PowerShield. User Manual

MCR1900 Media Converter 19-Slot Chassis

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Model 201 Wiegand Touchpad Reader Installation Guide

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Instructions A Amp AC/DC Current Probe

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

HP UPS R1500 Generation 3

i410/i1010 AC/DC Current Clamp

User's Guide. True RMS Industrial Multimeter

MCA Series Multi-Channel Amplifiers. Operation Manual

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Agilent 87421A/87422A Power Supply

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

PagePac PAGEPAL V

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

User Manual. CFG253 3 MHz Function Generator

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

HVA200 High Voltage Amplifier

PEDAL POWER 4x4. User s Manual.

Mini Power Bank and Charger

LOXONE 12 Channel Amplifier

How To Use A Power Supply Unit (Upu)

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Benchtop Computer Monitor Generator

Installation and Operation Guide for PD5100 Automatic Transfer Switch

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Seven function digital multimeter

VS-0202 VS User Manual

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Model SPDT Relays

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Voltech DC1000. Precision DC Bias Current Source

DC POWER SUPPLY ALIMENTATION C.C.

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

TTL to RS232 Adapter User Guide

7 FUNCTION DIGITAL MULTIMETER

64-CHANNEL INTEGRATED AMPLIFIER

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

BITMAIN. APW PSU Series User Guide

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

AXIS 291 1U Video Server Rack Installation Guide

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

Tone Hammer 500. Owners Manual. Manual Version 1.0

Water Leak Detection System

Research RF Sputtering Packages

MA-4150 ORDERCODE D6149 Highlite International B.V.

2 Bay FireWire 800/400/USB RAID Solution RAID 0, RAID 1, & JBOD. User Manual

Zetron Desktop Microphone Manual F

MDI/MDIX) FEP-32008T-3

16/32 Channel 1U Rack Mount CCTV Power Supply

Remote Alarm Monitoring System

User Guide. 4 wire Earth Resistance Tester Model GRT300

OPERATING INSTRUCTIONS

Notice. Reverse engineering and disassembly are prohibited.

Modular I/O System Analog and Digital Interface Modules

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Agilent P940xA/C Solid State PIN Diode Switches

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

PUMP DRIVES ENTRAÎNEMENTS DE POMPES PUMPENANTRIEBE MOTOR DE BOMBAS UNITÀ DI CONTROLLO POMPA OPERATING MANUAL: MODE D EMPLOI:

Tablet 30W Tablet 92W

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

OPERATION MANUAL. VDA-106A Video Distribution Amplifier. 1 st Edition - Rev.1

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

AXIS T81B22 DC 30W Midspan

Single Station Remote Alarm

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

INSTALLATION INSTRUCTIONS

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

HDMI Switch USER MANUAL VS481A

Drayton Digistat +2RF/+3RF

Transcription:

USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus

Warranty Newport Corporation guarantees its products to be free of defects for one year from the date of shipment. This is in lieu of all other guarantees, expressed or implied, and does not cover incidental or consequential loss. Information in this document is subject to change without notice. Copyright 2012, 2001-1998, Newport Corporation. All rights reserved. The New Focus logo and symbol are registered trademarks of Newport Corporation Document Number 90061076 Rev. A 2 New Focus

Contents Warranty...2 Important User Safety Information...4 General Warnings... 4 Definitions and Symbols... 5 Environmental Specifications... 5 Contact Information... 6 Introduction...7 Getting Started... 8 Voltage and Fuse Selection... 8 Operation...10 Output Characteristics... 10 Cables... 11 Customer Service...12 Technical Support... 12 Service... 12 Model 0901 User Guide 3

IMPORTANT USER SAFETY INFORMATION DO NOT DISCARD General warning in the event of a hazard Do not position this device in such a manner that would make it difficult to disconnect the power cord from the device or the power source. Position the equipment so that access to the mains disconnect ON/OFF switch on the front panel readily available. Push the power ON/OFF switch in the front of the device to OFF position to turn OFF the power to the internal electronics. The OFF position: push the actuator or switch rocker arm so the O depressed. (To connect power to device, push the actuator or switch rocker arm so the 1 depressed). Fully disconnect the power cord of the device from MAIN power. Grounding and Powering the device Verify that the line voltage setting on the rear of the Power Supply Model 0901 matches the local Main Power from the power cord. Verify that proper fuses installed for amps and time delay. To avoid electronic shock, connect the instrument to properly earth-ground, 3-prong receptacles by using the supplied power cord only. Failure to observe this precaution can reduce equipment performance. General warning and precaution Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged. The user should not attempt any maintenance or service of the device beyond the procedures outlined in this manual. Any problem that cannot be resolved should be referred to NEW FOCUS Technical Support. 4 New Focus

Definitions and Symbols The following terms and symbols are used in this documentation and appear on the Model 0901 Power Supply where safety-related issues occur. Electronic shock This symbol indicates a hazard arising from dangerous voltage. Any mishandling could result in irreparable damage to the equipment and personnel injury. l O ON Symbol This symbol represents Power On OFF Symbol This symbol represents Power Off Attention Refer to the operator instructions of manual before operating equipment. Environment Specification Voltage Requirements 100/120/220/240 ~VAC, 47.5-66Hz Electrical Ratings 100-120~VAC, 0.5A; and 220-240~VAC, 0.25A (47.5-660Hz) Size (H x W x D) [in. (mm)] 3.5 (90.0) x 7.65 (195.0) x 8.0 (200.0) Mainframe Weight [lb (Kg)] 6.5 (2.8) Operating Temperature Storage Temperature Relative Humidity, Storage Altitude Installation Category Pollution Degree 2 Use Location 10ºC to 40ºC (<90% humidity noncondensing) 0ºC to + 50ºC (<90% humidity noncondensing) <90% humidity non-condensing <3000 meters (10000 feet) II Indoor use only Model 0901 User Guide 5

The power entry module requires two 5x20 mm, Slo-Blo fuses. The table below identifies the correct voltage selector switch setting and fuse rating for several common AC power. Input Power (47.5 to 66 Hz) Voltage Switch Setting Fuses (250~VAC Slo-Blo) 100 VAC 100 0.5AT 120 VAC 120 0.5AT 220 VAC 220 0.25AT 240 VAC 240 0.25AT Contact Information North America Europe New Focus Newport/MICRO-CONTROLE S.A 3635 Peterson Way Zone Industrielle Santa Clara, CA 95054 USA 45340 Beaune la Rolande, FRANCE Telephone: (866) 683-6287 Telephone: (33) 02 38 40 51 56 Telephone: (408) 919-1500 Email: Sales@newfocus.com 6 New Focus

Introduction The New Focus Model 0901 Power Supply is a triple output, low-noise, ±15-V DC power supply. It is intended for use with all New Focus brand products which require ±15-V DC, and can also serve as a general purpose supply for laboratory use. It is capable of simultaneously powering three devices, each requiring ±15 V and up to 300 ma. Two of the outputs are provided via three-pin M8 style connectors (compatible with other New Focus products), while the third uses banana jacks. (See Figure 1.) Figure 1: Model 0901 front panel. Model 0901 User Guide 7

Getting Started Voltage and Fuse Selection The Model 0901 can operate with an input of 100, 120, 220, or 240 V AC with AC frequencies of 47 63 Hz. The unit is configured for 120 V AC at the factory; if it will be used with a different AC voltage, this will need to be selected on the power module on the back panel. The fuses may also need to be changed. See below. To check the voltage setting, look at the voltage indicator on the AC power module on the back of the power supply. (See Figure 2.) Figure 2: Model 0901 rear panel showing AC power module & voltage indicator. To change the voltage/fuses: 1. Make sure the power supply is turned off. 2. Disconnect the AC power cord. 3. Open the cover of the power module using a small blade screwdriver or similar tool. 8 New Focus

Figure 3: Power module with the cover open Input Power (47.5 to 66 Hz) 4. Remove the AC-voltage selection wheel from the unit. Do not attempt to rotate the wheel while it is still in the power module; the wheel must be removed, turned, and then reinserted for proper operation. (See Figure 3.) 5. Reinsert the wheel in the module so the desired AC voltage can be viewed in the power-module window. 6. Ensure the proper fuses for the new AC voltage are installed (see Table 1). Pull out fuse holders to replace if needed. 7. Close the power-module cover. 8. Verify the proper voltage is showing through the module window. 9. Reconnect the AC power cord. Voltage Setting Switch Fuses (250~VAC Slo-Blo 100 VAC 100 0.5AT 120 VAC 120 0.5AT 220 VAC 220 0.25AT 240 VAC 240 0.25AT Table 1: The AC power module requires two 5x20-mm, 250-V, Slo-Blo fuses. The current ratings of the fuses should be as shown. Model 0901 User Guide 9

Operation Output Characteristics The outputs (three pairs of ±15 V) of the Model 0901 are all derived from a common linear supply, but each incorporates independent current-limiting protection as shown in Figure 4. As a result, the voltage on each output differs slightly. The impedance of each output is approximately 2 ohms, so an output will be reduced by 0.6 V when providing the full 300 ma. With no load, outputs should be ±15 V ±3%. When a load attempts to draw in excess of 300 330 ma the protection is activated. It is accomplished via fast foldback current limiting (the value of the current limit is lower for loads which attempt to draw a greater current). In the extreme case of a short-circuited output, the current through the short will be less than 100 ma. Figure 4: Block diagram and pin assignments (as seen on front panel) of the Model 0901 power supply. 10 New Focus

Cables New Focus offers three types of cables for use with the Model 0901: Model # Description 0923 cable, M8 connector (male) to M8 connector (male), 1 meter 0923-2 cable, M8 connector (male) to M8 connector (male), 2 meter 0924 cable, 3 banana plugs (male) to M8 connector (male), 1 meter Models 0923 and 0923-2 are used to connect from the M8 connectors on the front panel of the Model 0901 to New Focus brand products. Model 0924 can be used for the following: - to connect from the banana jacks on the front panel of the 0901 to New Focus brand products - to connect New Focus brand products to a supply other than an 0901 which has banana jack outputs - to connect to the M8 connectors on the Model 0901 front panel so as to provide ±15 V on the banana plugs for general lab use. When connecting cable Model 0924 to the Model 0901, note that the colored male-banana plugs on the cable should follow the color-coding for the Model 0901 banana jacks: red is +15 V, green is ground, and black is -15 V. Model 0901 User Guide 11

Customer Service Technical Support Information and advice about the operation of any New Focus product is available from our technical support engineers. Engineers are on duty from 8:00 5:00 PST, Monday through Friday (excluding holidays). For quickest response, ask for Technical Support and know the model number for your product. The model number is usually found on the front panel. Phone: USA (408) 980-5903 Support is also available by email. Email: techsupport@newfocus.com We typically respond to email within one business day. Service In the event that your product malfunctions or becomes damaged, please contact your local Newport Sales office or agent for a return authorization number and instructions on returning the unit 12 New Focus