Agilent 87421A/87422A Power Supply



Similar documents
Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent 4338B Milliohm Meter

The Next Generation in Automated Oscilloscope Test

Think SAFETY When Selecting a Handheld Multimeter

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent 4339B/4349B High Resistance Meters

Agilent U2000 Series USB Power Sensors

802.11ac Power Measurement and Timing Analysis

Agilent Television Power Consumption Testing. Application Note

Agilent E5063A ENA Series Network Analyzer

Agilent P940xA/C Solid State PIN Diode Switches

Agilent E6832A W-CDMA Calibration Application

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

1.5 GHz Active Probe TAP1500 Datasheet

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

DDR Memory Overview, Development Cycle, and Challenges

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Make Better RMS Measurements with Your DMM

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

Handheld portable appliance testers

Agilent FieldFox Remote Viewer

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Application Note. Double click System tray icon after service started. Click start/continue button

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

PXI and AXIe Modular Instrumentation

PXI and AXIe Modular Instrumentation

DC POWER SUPPLY ALIMENTATION C.C.

NI USB-6008/6009 OEM USER GUIDE

HP Port Switches Quick Setup Guide

Report on Government Information Requests

Broadband Telecommunications Drop Amplifier

EGSTON Standard E2xFxWx 12W

DS 600. A contact free flux gate based current measurement sensor 600A rms

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Agilent EEsof EDA.

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

The Real Total Cost of Ownership of Your Test Equipment

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

±15 V Current-Limited Power Supply

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

PEDAL POWER. User s Manual

Multi-Range Programmable DC Power Supplies 9115 Series

Building Hybrid Test Systems, Part 1

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Evaluating Oscilloscope Bandwidths for Your Application

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Keysight N6854A Geolocation System. Configuration Guide

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Redundancy Module QUINT-DIODE/40

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Agilent E5100A Network Analyzer

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

HP Port and 48-Port Switches Quick Setup Guide

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Power Supplies in Medical Electronics

Duct Humidity Transmitter

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

Current Monitoring Kit

Multi-Range Programmable DC Power Supplies 9115 Series

Keysight Technologies N9320B RF Spectrum Analyzer

ADJUSTABLE VOLTAGE AND CURRENT REGULATOR

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323

Installation & Operation Manual. Type 1801 External Seahorse Pantograph Wiper. without Control System

Transcription:

Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration The Agilent 87421A and 87422A power supplies are universal input, dc switching power supplies designed to provide the bias voltages needed to operate Agilent microwave system amplifiers. These compact power supplies are ideal for integration into a system or for use on a benchtop. The 2 meter dc bias cable permits the amplifier to be remotely located, allowing it to be placed out of the way or where space is not critical. The 87421A is a 25 watt, ±12V dc power supply designed to power the Agilent 83006A, 83017A, 83018A, and 87415A microwave system amplifiers. A 2 meter cable is included for direct connection to the amplifier. The 87422A is a 90 watt, ±15V dc power supply designed to power the Agilent 83020A microwave system power amplifier. One additional ±12V dc output is provided to power a preamp such as the 83006A or 83017A. Included with the power supply are the necessary 2 meter cables to connect to the amplifier. The 87421A may also be used to provide bias voltages for the Agilent 83440C high speed lightwave converter. Using the 83440-60009 lightwave converter power supply adapter, the 87421A becomes a compact, convenient power supply for use with the lightwave converter.

Product specifications Agilent 87421A Agilent 87422A Output voltage/current +12V at 2 A +15V at 4.0 A 12V at 200 ma 15V at 200 ma +12V at 2 A 12V at 200 ma Output power 25 W 90 W Line regulation 0.1% 0.1% Load regulation (20% to full load) 2.0% 1.0% Output ripple 25 mv RMS max 25 mv RMS max Output noise 2% peak to peak max 2% peak to peak max Overvoltage limit protected Yes Yes Short circuit protection Current limited for overload and shod Current limited for overload and short circuit protection. Normal operation circuit protection. Normal operation returns upon removal of overload. returns upon removal of overload. General specifications AC input voltage 90 250 VAC, 50/60 Hz 90 240 VAC, 50/60 Hz Fuse 1 A, slow blow T 3.15 A Weight 0.9 kg (2.0 lb) 2.1 kg (4.6 lb) Shipping weight 1.8 kg (4.0 lb) 3.2 kg (7.0 lb) Environmental specifications Operating temperature 0 to +55 C full load 0 to +55 C full load Storage temperature 40 to +70 C 40 to +70 C 2

Other product and operating information Operation of the power supplies involves connecting the power supplies output to the amplifier dc input with the cable provided. The power supplies include a power cord with protective ground for connection to 90 240 VAC. Mounting holes are provided as shown in the outline drawings. The power supplies may be mounted in any orientation with user supplied hardware. To ensure continued compliance to product safety and EMC specifications, connect the power supplies to an amplifier only with the cable provided. Do not attempt to modify or extend the dc output cable. For help with special applications requiring longer cables contact your Agilent call center listed on the back page. The power supplies have a fuse located next to the IEC appliance inlet. If it is necessary to replace the fuse, disconnect the power supply from both AC power and the amplifier. Using a slotted screwdriver, open the fuse cover and replace the fuse. The power supplies contain no user serviceable parts (with the exception of the fuse). If service is required, please contact your Agilent sales office or nearest Agilent Service Center. The Agilent 87421A power supply provides the dc power needed to bias the 83006A, 83017A, and 83018A. The power supply comes with a 2 meter long cable to allow easy connection between the amplifier and the power supply. Dimensions in millimeters and (inches). 3

Ordering information Agilent 87421A power supply Includes power supply, AC power cord, and part number 83006-60005, which is a 2 meter cable with a 3-pin connector on one end and a D-subminiature connector on the other end for direct connection to the Agilent 83006A, 83017A, 83018A, and 87415A microwave system amplifiers. Agilent 87422A power supply Includes power supply and part number 87422-60001, which is a 2 meter cable with 15-pin connectors for direct connection to the Agilent 83020A amplifier. One additional dc output is provided to supply power to a preamplifier such as the 83006A or 83017A. Other instruments and accessories 83006A Microwave System Amplifier, 0.01 to 26.5 GHz 83017A Microwave System Amplifier, 0.5 to 26.5 GHz 83018A Microwave System Amplifier, 2 to 26.5 GHz 83020A Microwave System Power Amplifier, 2 to 26.5 GHz 87415A Microwave System Amplifier, 2 to 8 GHz 83440C High Speed Lightwave Converter, dc to 20 GHz, 1000 to 1600 mm 83440-60009 Lightwave Converter Power Supply Adapter The Agilent 87422A power supply provides the dc power needed to bias the 83020A. DC cables shown above shipped with power supply. Dimensions in millimeters and (inches). 4

Safety and Regulatory Information Manufacturer s Declaration This is to certify that this product meets the requirements specified in IEC 1010 and IEC Publication 348, Safety Requirements for Electronic Measuring Apparatus. It has been supplied in a safe condition for indoor use only and may occasionally be subjected to temperatures between +5 and 10 Celsius without degradation of its safety. The present data sheet contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the product in safe condition. The main plug shall be inserted in a socket outlet provided with a protective earth contact. The protective action must not be negated by the use of an extension cord without a protective conductor. Warning: Any interruption of the protective conductor inside or outside the product or disconnection of the protective earth terminal is likely to make the equipment dangerous. Intentional interruption is prohibited. This product has been designed to be safe under the following environmental conditions: indoor use; altitude up to 2,000 meters; temperature range expanded to include 0 to +55 Celsius; maximum relative humidity 80% up to 31 degrees Celsius decreasing linearly to 50% relative humidity at 40 degrees Celsius; mains supply voltage fluctuations not to exceed ±10% of nominal voltage; transient over voltage category II for the main ac supply voltage; pollution degree two. If the equipment is used in a manner not specified by Agilent Technologies, the protection provided by the equipment may be impaired. Model 87422A 5

DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and CEN/CENELEC EN 45014 Manufacturer s Name: Manufacturer s Address: Agilent Technologies, Inc. 1400 Fountaingrove Parkway Santa Rosa, CA 95403-1799 USA Declares that the products Product Name: Microwave System Amplifiers Model Numbers: 83006A, 83017A, 83018A, 83020A, 83050A, 83051A, 87421A, and 87422A Product Options: This declaration covers all options of the above products. Conform to the following product specifications: EMC: IEC 61326:1997+A1:1998+A2:2000/ EN 61326:1997+A1:1998+A2:2001 Standard Limit CISPR 11:1997 / EN 55011:1998/A-1999 Group 1, Class A IEC 61000-4-2:1995+A1998 / EN 61000-4-2:1995 4 kv CD, 8 kv AD IEC 61000-4-3:1995 / EN 61000-4-3:1995 3 V/m, 80-1000 MHz IEC 61000-4-4:1995 / EN 61000-4-4:1995 0.5 kv sig., 1 kv power IEC 61000-4-5:1995 / EN 61000-4-5:1996 0.5 kv L-L, 1 kv L-G IEC 61000-4-6:1996 / EN 61000-4-6:1998 3 V, 0.15 80 MHz IEC 61000-4-11:1994 / EN 61000-4-11:1998 1 cycle, 100% Supplementary Information: The products herewith comply with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carry the CE-marking accordingly. Santa Rosa, CA, USA 25 November, 2002 Greg Pfeiffer/Quality Engineering Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor. 6

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment,including initial start-up assistance,onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com www.agilent.com/find/mta For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0)118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 1997, 2000, 2002, 2010 Printed in USA, May 27, 2010 5091-4292E