Maximum safety for high-risk applications Increased security Synthesis Twin, featuring parallel configuration compatibility by up to 3 units, provides a higher level of reliability for mission critical applications. Due to the exceptional functions offered by the parallel configuration, you can increase the power of the UPS you have chosen at any time to guarantee the load by adding a second UPS and even a third: these additional units will be redundant, in standby. In this case, the load will no longer be 100% but will be reduced to 50% or 33% and the protection will consequently be increased to an unprecedented level. Synthesis Twin, therefore, is the ideal support for operations in high risk environments: communications systems, including satellite systems, air traffic control systems, Internet nodes, bank transactions and any other application which requires maximum reliability, high power availability and precision. The system grows with your company Expandable on site up to 3 times Parallel means more than just safe. Due to the leading edge functions offered by this configuration, Synthesis Twin can follow changes in the size of the load to ensure that your initial investment is not wasted.you can add, to the first UPS, a second UPS with the same power and + + then a third, so that the overall power of your protection system is, at all times, ideal for the load carried. Expanding your UPS system can be carried out on site without any interruptions to service. Integrated service for total safety 24-hour surveillance all year round with LIFE2000 The high reliability of this UPS can be improved even further with the addition of LIFE2000, the only remote monitoring program designed for real-time troubleshooting.your UPS maintains regular contact with the Chloride Customer Service Centre and, in the event of disturbance, warns the operators so that they can intervene, often remotely, and even before you have noticed that there is a problem. At regular intervals, a report is transmitted to the Service Centre with all the information relating to UPS performance. This program allows you to delegate the care of your system to our experts. A Synthesis of the best technologies From low consumption to maximum safety The objective of the development of Synthesis Twin was to combine, in a single product, the basic features of the two most innovative, efficient and effective technologies: Digital Interactive and Double Conversion. The first technology ensures exceptionally high reliability with very low running costs thereby guaranteeing good returns on energy saving when the current conditions are close to the nominal values of maximum efficiency of the system. The second technology guarantees absolute safety under extreme power supply conditions. Synthesis Twin now combines both technologies using a switch which automatically adapts the system to the conditions of the power supply, guaranteeing maximum performance levels.
Adapts to all requirements Wide choice of ratings and autonomies The power ratings available range from 4 to 30 kva.this means the UPS is ideal for all company sizes and requirements. Synthesis Twin also provides a wide selection of battery lives and a number of options ensuring up to four hours of autonomy. Excellent performance levels Extraordinary compatibility and no waste The input cosϕ value is > 0.99. Therefore, Synthesis Twin only absorbs active power. This means considerable savings for your company.you can count on maximum power supply quality at all times and in all situations, with absolutely no waste. This UPS also has considerable immunity to electrical disturbances and can operate in hostile environments. Thanks to the high PFC (Power Factor Corrector), it also guarantees very low harmonic emissions thus preventing disturbance to other applications. Our UPS performs at maximum levels even when the power supply quality is not constant and when the power supply voltages and frequencies are considerably different from the nominal values. In practise, this means that there is a tolerance range which ensures that the system can operate, without using the batteries, even with a power supply voltage 40% lower than the nominal value. Advanced Battery Care Increases the life of the batteries We never tire of emphasising the importance of the battery. Battery reliability and replacement costs are among the most important factors to be considered when choosing a UPS. At Chloride we have always attached primary importance to the battery. Now, Twin can be relied on to check your power supply source and to handle it extremely efficiently, increasing battery life by up to 50%. Here are some of those life saving features: - Wide input voltage acceptance range (up to 40%). - Temperature compensated battery charger. - Intelligent battery charger. - Charge and discharge cycle control. - End of discharge voltage compensated with time. - Minimum ripple current values. - Algorithm to calculate battery life expectancy. - Battery test. As you can imagine, this all adds up to considerable reductions in running costs. Maximum information Extremely efficient communications Another great advantage of this UPS is its flexibility at an interface level. Synthesis Twin is completely customisable and keeps you informed. It has a serial interface and monitoring and control program, with an exclusive function: roundthe-clock shutdown service software, which safely shuts down your network when required. You want to know more about your UPS' current operating status? Just glance at the coloured LEDs. If you want more detail, operating parameters are displayed in 6 languages. To make it even easier, there are further options: a portable display for convenient viewing and two graphic software options - Easy Plus for local controls and Easy Plus Remote Access for remote controls. Two easy ways to monitor your installation. Customising your UPS Vast range of options Customisation to your specification is guaranteed by the numerous options offered by Synthesis Twin. Here is just a small selection. In terms of hardware, Twin features parallel kit for 2 or 3 units, galvanic isolation transformer, extended battery charger; user interface card, additional RFI filters (class B), backfeed protection system and the multiple AS400. For software, we have the SNMP adapter, EPRA for remote monitoring and the communication kit for J-BUS protocol. Also available for this UPS is the Multicom option which allows the number of serial ports to be expanded up to a maximum of three.
POWER PROTECTION SINGLE-PHASE - SINGLE-PHASE THREE-PHASE - SINGLE-PHASE THREE-PHASE - THREE-PHASE TECHNICAL CHARACTERISTICS 6/11 8/11 10/11 12/11 15/11 20/11 6/31 8/31 10/31 12/31 15/31 20/31 10/33 12/33 15/33 20/33 30/33 Output power at 25 C with cosϕ = 0.7 (kva) 6,6 8,8 11 13,2 16,5 22 6,6 8,8 11 13,2 16,5 22 11 13,2 16,5 22 33 Output power at 40 C with cosϕ = 0.7 (kva) 6 8 10 12 15 20 6 8 10 12 15 20 10 12 15 20 30 INPUT Number of phases 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 Voltage (V) 230 230 230 230 230 230 400 400 400 400 400 400 400 400 400 400 400 Tolerance at full load (%) ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 ± 25 Tolerance at 75% load (%) +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 +25/-40 Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Power factor 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 > 0.99 >0.99 > 0.99 > 0.99 > 0.99 THDi (%) < 3 < 3 < 3 < 3 < 3 < 3 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 < 10 OUTPUT Number of phases 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 Voltage (V) 230 230 230 230 230 230 230 230 230 230 230 230 400 400 400 400 400 Static stability of voltage (%) < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 < 1 Frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 Stability of the frequency with network synchorisation (%) ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 ±0.5/±8 Output harmonic distortion IEC/EN 62040-3 compliant IEC/EN 62040-3 compliant IEC/EN 62040-3 compliant GENERAL DATA Typical autonomy (minutes) 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 Operating temperature ( C) 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 0-40 Colour RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 RAL7035 AC/AC performance (%) - with Digital Interactive Technology 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 98 - with Double Conversion Technology 91 92 92 92 93 93 91 92 92 92 93 93 92 92 93 93 93 DIMENSIONS AND WEIGHTS Height (mm) 595 1000 1000 1000 1115 1115 595 1000 1000 1000 1115 1115 1000 1000 1115 1115 1400 Width (mm) 265 450 450 450 605 605 265 450 450 450 605 605 450 450 605 605 700 Depth (mm) 735 800 800 800 870 870 735 800 800 800 870 870 800 800 870 870 895 UPS weight without batteries (kg) 40 95 95 95 170 170 50 95 95 95 170 170 110 110 170 170 240 UPS weight with standard batteries (kg) 82 188 188 188 330 330 90 188 188 188 330 230 222 222 330 330 542
POWER PROTECTION Integrated service for total safety A synthesis of the best technologies Adapts to all requirements Excellent performance levels Advanced Battery Care The system grows with your company Maximum information Maximum safety for high-risk applications Customising your UPS The beauty of Synthesis Twin is its combination of Chloride s top reliability and exceptional flexibility. Designed for the protection of mission critical applications, with the twin architecture available in single-phase and three-phase versions, it is the ideal solution for the most critical systems of all types: communications systems, including satellite systems, air traffic control systems, Internet nodes, bank transactions and any application requiring maximum reliability, high power availability and precision.
AUSTRALIA Units CIA & CIB Centrecourt Business Park 25-27 Paul Street North Ryde NSW 2113 Telephone: +61 2 9888 1266 Facsimile: +61 2 9888 1966 Australia.sales@chloridepower.com BRAZIL Latin America Rua Arizona 1349, 6 Andar Brooklyn Novo Sao Paulo CEP 04567-002 Brazil Telephone: +55 11 5505 4661 Facsimile: +55 11 5505 4832 Latinamerica.sales@chloridepower.com CHINA Chloride Masterguard Power Systems Ltd. 1510 Chuan Qiao Lu Jin Qiao Export Processing Zone Pudong, Shanghai 201026 P.R. China Telephone: 0086 21 58543080 Facsimile: 0086 21 58545890 China.sales@chloridepower.com FRANCE 1 rue Felix Potin ZA Les Belles Vues 91290 Arpajon - France Telephone: +33 1 6926 1281 Facsimile: +33 1 6083 1816 France.sales@chloridepower.com GERMANY Masterguard Schallershofer Str. 141 D-91056 Erlangen - Germany Telephone: +49 9131 9855 100 Facsimile: +49 9131 9855 270 info@masterguard.de ITALY Chloride Silectron Via Fornace 30 40023 Castel Guelfo (BO) - Italy Telephone: +39 0542 632 111 Facsimile: +39 0542 632 120 Italy.sales@chloridepower.com PORTUGAL Rua dos Tercos 574 Zona Industrial de Canelas 4405 270 Canelas Vila Nova de Gaia - Portugal Telephone: +351 22 7151 210 Facsimile: +351 22 7126 337 Portugal.sales@chloridepower.com SPAIN Chloride España S.A.U. Edificio Europa III C/ San Rafael nº 1 Pol. Ind. Alcobendas 28108 Alcobendas Madrid Spain Telephone: +34 91 414 00 30 Facsimile: +34 91 662 37 76 Spain.sales@chloridepower.com THAILAND 127/25 Panjanthi Tower, 20th Floor Nonsee Road Chongnonsess, Yannawa Bangkok 10120 Thailand Telephone: +66 2 6810100 Facsimile: +66 2 6810109 Thailand.sales@chloridepower.com TURKEY Masterguard E-5 Bostanci Koprusu Kavsagi Sebnem Sokak Nº 10, Kat: 3-4-7-8 81110 Bostanci Istanbul Turkey Telephone: +90 216 464 47 00 Facsimile: +90 216 464 47 15 Masterguard@masterguard.com.tr UAE Chloride UPS Systems Middle East Building 5, Office 104 Dubai Intenet City Dubai UAE PO Box 72536 Telephone: +971 4 391 3205 Facsimile: +971 4 391 6803 Middleeast.sales@chloridepower.com. UK George Curl Way Southampton Hampshire SO18 2RY United Kingdom Telephone: +44 (0) 23 8061 0311 Facsimile: +44 (0) 23 8061 0852 Uk.sales@chloridepower.com USA 28430 N. Ballard Drive Lake Forest Illinois 60045 USA Telephone: +1 800 239 2257 Facsimile: +1 800 833 6829 Usa.sales@chloridepower.com POWER PROTECTION www.chloridepower.com ISO 9001 Cert. No FM 10144 This publication is for information purposes only. The company has a policy of continuous product improvement and therefore reserves the right to vary any information quoted herein without prior notice. MKA3L0UKTWIN1 REV.3/06-2003