289 SERIES FLOW METER TRANSMITTERS



Similar documents
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Advantium 2 Plus Alarm

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Subminiature Load Cell Model 8417

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

SDX Submersible Depth Transmitter User Manual

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Model EC5111 Speed Controller Isochronous / Droop

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Turbine Flow Sensor Series VTR

Differential-Hall-Effect based Sensors Series A5S

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Turbine Flowmeters for Gas Applications

Transmitter Interface Program

For Multi-Parameter Meters see mvx

User's Guide. True RMS Industrial Multimeter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

The Do s and Don ts of Pressure Transducers

How To Use A Flowmeter

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Instruction Manual. T3111 T3111L T3111P T3111Ex

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Duct Humidity Transmitter

T0118 T2118 T3118. Instruction Manual

FAQ s on Siemens Magmeters

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Specifying a Variable Frequency Drive s

4 Posiflow Proportional Solenoid Valves

Centro-Matic Automatic Lubrication Systems System Controls

Contents. Document information

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

! WARNING. Before using product, read and understand instructions.

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Series DFMT Digital Paddlewheel Flowmeter

Mono-Block II Installation & Operation Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Mounting Instructions. Torque Transducer. A en

Kit Watt Audio Amplifier

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Proximity Transmitters and Seismic Vibration Transmitters

LM35 Precision Centigrade Temperature Sensors

C ole s quality Open Frame Instrument Rotary Switch provides low

Operating instructions

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

In-Line Electronic Flow Switches

Energy and Flow Measurement for Hydronic Systems

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Single sub-base valve

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Capacitive Prox E2K-X

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Experiment 5. Strain Gage Measurements

Hydraulic Control Solutions

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Description. Dimensions. Features. precision works better

Installation and maintenance instructions. Danfoss Vent

POWER AND VOLTAGE RATING

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

AutoRanging Digital MultiMeter

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

PRODUCT PROFILE FEATURES

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Application Note. So You Need to Measure Some Inductors?

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Lab E1: Introduction to Circuits

HERZ-Thermal Actuators

RADIANT PLASMA 4700 Plasma Spark Generator

Fundamentals of Inverter Fed Motors

PTU Series Ultrahigh-Purity Pressure Transducers

User Manual for CH-PFC76810

Toroidal Conductivity Sensor

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Series 7500 Torque Sensor

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

Series 510 Submersible Level Transmitters

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

LCD Readout Digital Pressure Switch

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Grounding Demystified

Electronic Flow Switches

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Inductors in AC Circuits

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

AC and DC Drive System Installation Information

Transcription:

289 SERIES FLOW METER TRANSMITTERS

INSTRUCTION MANUAL 289 SERIES TRANSMITTER 289-763 Pickup Coil/Amplifier, Amphenol Connector 289-773 Pickup Coil/Amplifier, Weather-Tight, Explosion-Proof* TABLE OF CONTENTS General Description............................Pg 2 Specifications.................................Pg 3 Installation...................................Pg 4 User Options & Adjustments.....................Pg 5 Maximum Transmission Distance..................Pg 6-7 Typical K-Factors..............................Pg 8 Schematics...................................Pg 9 *U.L.Class I, Group C & D Class II, Group E, F & G 289-760-350 1987 (Rev 5/06), Max Machinery, Inc. Max Machinery, Inc. reserves the right to make changes to the product in this Instruction Manual to improve performance, reliability, or manufacturability. Consequently, contact MMI for the latest available specifications and performance data. Although every effort has been made to ensure accuracy of the information contained in this Instruction Manual, MMI assumes no responsibility for inadvertent errors.

General Description The 289 Series Transmitter has an inductive pickup which senses the motion of an internal flow meter gear. As the tooth of a gear moves under the core of the pickup, a voltage is induced in a coil wound around the core. The gear is fastened to the rotor shaft of the 240 Series meter, which allows its rotational rate to be directly proportional to the flow rate. The output of the pickup coil is amplified and squared before being sent to the output terminals. The resulting pulse train is relatively insensitive to interference and can be transmitted as far as generally required. 289-760-350 1987 (Rev 5/06) Max Machinery, Inc. ( 2 )

Specifications 289-763/773 5V Square Wave Output: Power Requirements: Voltage (5V regulator on PCA).....................5-24VDC Nominal (3.5-30V Max) Current (No Load) Supply Voltage Operating Calibrating 3.5V 1.1mA 1.6mA 5.0-24.0V 1.8mA 3.0mA Output Signal Shape......................................Square Wave Amplitude..........................................5V Rise and Fall Time...................................3µS Output Impedance..............................<200ohms Maximum Frequency................................5kHz Minimum Frequency...............................1/50Hz Output vs Load: (Supply > 5.2V) Load ma Output Low Output Hi 0.1mA 0V 5.00V 1.0mA 0V 4.85V 5.0mA 0V 4.25V 10.0mA 0V 3.45V Temperature Limits (All Models): Operating Electronics..........................-5 to 150F (-20 to 65C) Pickup Coil.....................-148 to 450F (-100 to 232C) Storage Electronics.........................-40 to 175F (-40 to 80C) Pickup Coil.....................-148 to 450F (-100 to 232C) ( 3 ) 289-760-350 1987 (Rev 5/06) Max Machinery, Inc.

Installation Mounting: The Model 289 transmitter screws on and off of the flow meter. Because of the random location of the starting point of the threads, one transmitter will probably not line up with the "in" and "out" ports of the flow meter like another will. The electrical outlet of the transmitter can be rotated one turn by loosening the clamping screw. (See drawing, page 2) Moisture Protection: The electrical circuitry of the weather-tight, explosion proof transmitter is enclosed in a liquid and vapor tight enclosure. All joints are sealed by welding or by "O"- rings. If this sealed condition is to be maintained, the conduit connection to the enclosure should be made liquid and vapor tight by using pipe dope or a potting fitting (U.L. requires a potting fitting within 18" of the transmitter.). If a transmitter is located outside and this precaution is not taken, moisture may form inside the housing. This will cause the circuitry to give an inaccurate output or possibly no output at all. In the long run it will cause corrosion and failure. The amphenol connector versions of the 289 Series Transmitter offer moderate protection from moisture and dust but are not totally sealed. Temperature Considerations: High ambient temperatures (120 F/50 C) should be avoided if possible. It is a good idea to locate the transmitter away from hot spots such as steam pipes, ovens and heaters. The electronics of the 289 Series Transmitters are rated for operation up to 65 C or 150 F. Because some heat travels from the flow meter to the transmitter electrical enclosure, the temperature the electronics see is a function of both the ambient and the flow meter temperature. The graph below shows the relationship between the maximum ambient transmitter temperature and the fluid temperature through the flow meter. The pickup coil of the 289 Series Transmitter is insulated with an epoxy that is rated to 232 C/450 F. This is the maximum flow meter fluid temperature. 289-760-350 1987 (Rev 5/06) Max Machinery, Inc. ( 4 )

User Options & Adjustments 289-763/773 TRANSMITTER Grounding: S2-l connects Common and Case directly together. S2-2 connects Common and Case through 4.7 µf capacitors. By using either switch the effects of electrical noise on the transmitter can be reduced. If the system is not grounded at the indicator or if the flow meter is not physically grounded through its plumbing, use S2-l. If the system is grounded at the indicator, use S2-2. This allows electrical noise between the case and the circuitry of the transmitter to be reduced without causing ground loop problems. To activate either switch, depress the side of the switch that is numbered. Sensitivity Adjustment R2, S1, LED: For best results, the transmitter amplifier sensitivity should be adjusted to match the output voltage of the particular pickup and flow meter it is mated to. This is typically factory calibrated, but should be checked if the coil or circuit board is changed or if the transmitter is switched from one flow meter to another. To adjust the sensitivity, set the flow rate through the flow meter to approximately midrange. Press the Sensitivity Adjustment Switch (S1): One or both sides of the LED should come on. Turn the Sensitivity pot (R2) FCW then turn it CCW just until both sides of the LED show equal brightness or are on for about equal periods of time (if the frequency is low). Outputs: The Model 289 transmitter output is generally sent to a signal conditioner display such as the Max 120, which provides signal dampening, scaling, and rate/total displays; as well as supplying power to the transmitter. A complete line of LCD display instrumentation is also available from MAX for flow rate, total, batching, and flow control. S1 Sensitivity Adjust Switch Coil Connectors R2 Sensitivity Adjust Sensitivity Adjust LED Amphenol Connection Option Signal (White) (D) Power (Red) (C) Common (Black) (B) Ground (Green) (A) S2-1 Ground S2-2 Filter Amphenol Pinout (Optional) A = Ground B = Common C = 5 to 24VDC D = Square Wave Output E = No Connection F = No Connection ( 5 ) 289-760-350 1987 (Rev 5/06) Max Machinery, Inc.

Maximum Transmission Distance MAXIMUM TRANSMISSION DISTANCE The graph below shows typical conductor capacitance load vs. cable length for several types of cable. For instance, 1,000 ft. of 7 conductor #18 gauge stranded wire will put a 0.04 µf capacitive load on the output of the Model 289 transmitter. 289-760-350 1987 (Rev 5/06) Max Machinery, Inc. ( 6 )

Maximum Transmission Distance MAXIMUM TRANSMISSION DISTANCE (continued) The graph below provides the relationship between output capacitance loading and rise and fall time for the Model 289-763/773 output signal. For instance, with 0.4 µf the rise time of the Model 289 is about 89 µs, and the fall time about 45 µs. Consequently, the absolute maximum frequency the 289 could put out would be 1/(80 + 45) µs = 8000 Hz (frequency = 1/time). The signal would be a saw tooth pattern. Generally, the transmitter will drive 5000 feet or more of cable with no problem. ( 7 ) 289-760-350 1987 (Rev 5/06) Max Machinery, Inc.

Typical K-Factors / Typical Connections Typical K-Factors for 240 Series Flow Meters using the 289 Series Transmitter 241 Flow Meter (.062 Liter/Rev) Pulses/Liter...............................................403 Maximum Rate.......................................190 L/min 242 Flow Meter (.182 Liter/Rev) Pulses/Liter...............................................219 Maximum Rate: SS Rotors.........................................450 L/min AL Rotors.........................................540 L/min 243 Flow Meter (.574 Liter/Rev) Pulses/Liter...............................................104 Maximum Rate: SS Rotors........................................1000 L/min AL Rotors........................................1400 L/min 244 Flow Meter (1.70 Liter/Rev) Pulses/Liter...............................................58.8 Maximum Rate: SS Rotors........................................2400 L/min AL Rotors........................................3500 L/min 289-760-350 1987 (Rev 5/06) Max Machinery, Inc. ( 8 )