A Complete Solution for Method Linearity in HPLC and UHPLC



Similar documents
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

INTRODUCTION. The principles of which are to:

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Optimize Your Process Operations by Improving Process Monitoring

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

What is Eluent Generation?

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Determination of Calcium and Magnesium in Brine

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

ProteinChip Energy Absorbing Molecules (EAM)

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

How To Test For Contamination In Large Volume Water

Analytical Test Report

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

[ Care and Use Manual ]

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Guidance for Industry

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Development of an Automated Method for Monoclonal Antibody Purification and Analysis. Introduction. Gurmil Gendeh, 1 Wim Decrop, 2 and Remco Swart 2 1

Determination of Caffeine in Beverages HPLC-1

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

[ Care and Use Manual ]

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Protocol: HPLC (amino acids)

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Thermo Scientific Vanquish UHPLC System. Revolutionize Your. UHPLC Experience

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Purification of reaction mixtures using flash chromatography.

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

PCI Express 1.0 (2.5 GT/s) Protocol Test

Reversed phase C-18 chromatography: From analytical scale to preparative scale

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Vitamin C quantification using reversed-phase ion-pairing HPLC

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Gas Chromatography Liner Selection Guide

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Delivering a. New Era. of Technical. Support Services

Global Investing 2013 Morningstar. All Rights Reserved. 3/1/2013

Smartline HPLC by design

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Agilent 4339B/4349B High Resistance Meters

Agilent Television Power Consumption Testing. Application Note

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Thermo Scientific ConFlo IV Universal Interface

Introduction. Methods. Sample Processing

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

FT-NIR for Online Analysis in Polyol Production

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

CORESTA RECOMMENDED METHOD Nº 80

ApplicationNOTE Introduction

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Agilent Automotive Power Window Regulator Testing. Application Note

Transcription:

Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering, Germany Introduction Validation for linearity requires the preparation and analysis of a set of several independently prepared solutions. As an example, according to ICH guidelines, HPLC method linearity is normally based on five concentration levels between 70% and 130% of the nominal concentration, each to be injected three times. The laboratory effort for this process can be substantial, especially if the method is required to quantify several substances simultaneously. To save time, it is common to prepare only one stock solution and subsequently dilute it to the different concentration levels. This procedure means that any error in the stock solution preparation is carried through all subsequent dilutions. In addition, it means that the preparation of the standards differs from the process used in day-to-day operation of the method, thus making comparison of the two processes difficult. This study presents a fully automated gravimetric solution to prepare all solutions for a calibration or linearity test independently and without error-prone manual interference. All solutions prepared are immediately ready for injection onto the UHPLC analysis system. A comprehensive software package establishes the sequence for linearity validation automatically. When the HPLC results are available, linearity according to ICH guidelines is instantaneously calculated by the software, and all results are assessed against specification requirements. This complete solution accelerates the process significantly, excludes typical operator errors that occur during manual sample preparation and result calculation, and produces results of full statistical integrity. Experimental Instrumental Configuration UltiMate 3000 Basic Automated System supporting pressures up to 620 bar at flow rates up to 10 ml/min, consisting of the modules listed in Table 1. Table 1. HPLC Module Configuration and Connection Tubing Pump Sampler Column ACC-3000 Compartment Detector Capillaries LPG-3400SD with 200 µl SpinFlow mixer kit DAD-3000 with semi-analytical flow cell (2.5 µl) Pump Sampler Sampler Column Column Detector 450 0.18 mm Viper 550 0.18 mm Viper 450 0.13 mm Viper

UHPLC Method Parameters The UHPLC method for analysis of soft drink ingredients used a core shell (fused core)-based 2.6 µm stationary phase material from Phenomenex. Detailed method parameters are listed in Table 2. Table 2. UHPLC Column and Method Parameters for Soft Drink Analysis Column Phenomenex Kinetex 150 3.0 mm, 2.6 µm, C18 Precolumn Phenomenex KrudKatcher, 0.5 µm Injection 20 µl Full-loop injection Volume Temperature 45 C Maximum Pressure 515 bar Data Collection 50 Hz/0.1 s Rate/Rise Time Eluent A Water/0.075% formic acid (ph 3.65) Eluent B CH 3 CN/0.06% formic acid Gradient 0.0 min 7% B 3.7 min 26% B 4.0 min 50% B 5.6 min 50% B 5.7 min 7% B 9.2 min 7% B Instrument Control and Data Handling The UltiMate 3000 system was controlled by Chromeleon Chromatography Data System (CDS) software, version 6.80. The fully automated sequence generation, data processing, and validation report generation is based on the Chromeleon Extension Pack 2. Sample Preparation All standards for the linearity test of the soft drink analysis method were prepared using automation to the final concentration, without further dilution steps. Solid dosing was performed with the Quantos QB1-L system (Mettler-Toledo, Greifensee, Switzerland) using QH075-B dosing heads (Figure 1). The stacked dosing of all five compounds (acesulfame K, saccharin, caffeine, vanillin, and benzoate) was performed directly into a 100 ml flask. Dosing of the methanol/water 1:1 sample solvent was also performed gravimetrically with the Quantos QB liquid dosing option (Figure 1). After dosing, vials were closed with slotted septa. The samples were then dissolved and homogenized by manual shaking before the vials were placed into the autosampler trays. Figure 1. Quantos QB1-L system for automated solid dosing and gravimetrically controlled liquid dosing. Results and Discussion Preparation of Samples for Linearity Validation Statistically, it is recommended that each concentration level for a linearity test be individually prepared. This has the effect of randomizing potential sources of error (e.g., a possible incorrect weighing for one of the standards). This is a time consuming process, however, so many laboratories prepare a stock solution and then dilute it to the different concentration levels. The advantage of this approach is that it is a fast way of preparing standards, but the major disadvantage is that any error in the stock solution will be carried through to the diluted standards. A better approach is to automate preparation of the standards. This can be achieved using the new Quantos QB1-L system from Mettler-Toledo. The system can automatically dispense and weigh analytes into HPLC vials or volumetric flasks. It can also weigh in the appropriate amount of diluents in order to provide a gravimetric solution. This experiment tested the linearity of five analytes in a soft drink analysis. The Quantos system automatically weighed the correct amount of each analyte, then the correct amount of diluent to provide the concentrations shown in Table 3. The time required to prepare these standards was only 50 min. A manual preparation based on the stock solution approach would take approximately 2 h, or 4 h for the and manual individual preparation of all concentration levels, would require approximately 4 h. 2 Optimization A Complete Solution of the Separation for Method Power Linearity of 1-D in Nano HPLC LC and Analysis UHPLC of Proteomics Samples

Table 3. Concentrations (mg/100 g) of Soft Drink Analytes Prepared by Quantos QB1-L Analyte Standard 1 Standard 2 Standard 3 Standard 4 Standard 5 Acesulfame K 7.390 9.730 9.930 11.450 13.650 Saccharin 2.695 3.480 3.890 4.305 5.085 Caffeine 2.800 3.700 3.995 4.355 5.220 Vanillin 6.285 8.110 8.995 9.860 11.655 Benzoate 14.050 18.100 19.665 21.910 25.855 Speeding the Analysis Method Using classic HPLC, a single soft drink analysis may take approximately 30 min. This means that the total run time for the linearity experiment will be 7.5 h (5 calibration levels 3 injections per level 30 min). With UHPLC, however, it is possible to signficantly decrease run time. Figure 2 shows the analysis of all five analytes, with all peaks separated in less than 4 min. This means that all injections can be performed in just 1.25 h. The sequence generation with three injections at five different concentration levels is performed automatically by the chromatography data system, thus reducing labor time. Data Analysis and Reporting of the Method Linearity Validation Once all data has been acquired, it is necessary to calculate the results. In keeping with ICH guidelines, the following values must be reported: correlation coefficient, y-intercept, slope of the regression line, and residual sum of squares. Laboratories must also confirm that the correlation coefficient is within the limits expected of the method (typically 0.999). Performing these calculations can be a time consuming task. Some laboratories use Excel spreadsheets in an effort to speed the process, but even this can be inefficient because users typically manually transcribe values into the spreadsheet, then have another person review the transcription. For this particular analysis, the estimated time for the use of spreadsheets and the associated review step is 2 h. Saccharin Caffeine Vanillin Benzoate Acesulfame K 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Minutes 28277 Figure 2. UHPLC analysis of five soft drink ingredients in less than 5 min. 3

The Chromeleon CDS software immediately generates results for all analytes and creates the complete report automatically. All that is required by the operator is to name the peaks and enter their concentrations a process that takes just 5 min. Figure 3 shows the automatically generated report for the analyte saccharin. Figure 3A The combination of the Quantos QB1-L and the Dionex UltiMate 3000 system produced outstanding results for the linearity experiment. Table 4 shows the correlation coefficient for all analytes, each of which has an R 2 value >0.999. Table 4. Correlation Coefficients of All Analytes Analyte R 2 Acesulfame K 0.99973 Saccharin 0.99989 Caffeine 0.99939 Vanillin 0.99971 Benzoate 0.99964 Save Time with Transfer to New Process As Table 5 shows, the time to perform the experiment using the traditional process is 13.5 h. This process involves manual sample preparation with individual weighing, HPLC analysis at conventional speed, manual data processing, and report creation. In contrast, the fully automated new UHPLC-based process can complete the required steps in just over 2 h, which corresponds to a more than 6-fold overall productivity increase. Figure 3B Table 5. Time to Perform Linearity Experiment: Traditional vs New Automated Process Step Time Taken (Traditional Process) Time Taken (New Process) Sample Prep 240 min 50 min Analysis 450 min 75 min Results 120 min 5 min Total 810 min 130 min 4 Optimization A Complete Solution of the Separation for Method Power Linearity of 1-D in Nano HPLC LC and Analysis UHPLC of Proteomics Samples

Summary The automated Quantos system enables a 4-fold reduction in sample preparation time, relative to manual weighing and liquid dosing. This approach encourages individual weighing for all concentration levels (rather than diluting from a stock solution) yet avoids human error and provides full electronic documentation. Transfer of the analysis to the new UHPLC process can accelerate separation time by factor of 6, and yield chromatograms with excellent peak resolution for the highest accuracy of analytical results. The greatest potential for time saving is in the fully automated data processing and reporting step. Using Chromeleon Extension Pack 2 for ICH-conforming method validation, this task can be performed up to 24 faster than the manual approach. In addition, the new process excludes possible errors associated with transfer of data from the chromatography software to the data evaluation and reporting software. Chromeleon and UltiMate are registered trademarks, and Viper is a trademark of Dionex a Thermo Fisher Scientific Corporation. KrudKatcher is a trademark of Phenomenex, Inc. Speed Simplicity Solutions Dionex Products north America Europe Asia Pacific 1228 Titan Way U.S. / Canada (847) 295-7500 Austria (43) 1 616 51 25 Benelux (31) 20 683 9768; (32) 3 353 4294 P.O. Box 3603 Denmark (45) 36 36 90 90 France (33) 1 39 30 01 10 Germany (49) 6126 991 0 Sunnyvale, CA Ireland (353) 1 644 0064 Italy (39) 02 51 62 1267 Sweden (46) 8 473 3380 Taiwan (886) 2 8751 6655 south America 94088-3603 Switzerland (41) 62 205 9966 United Kingdom (44) 1276 691722 Brazil (55) 11 3731 5140 (408) 737-0700 www.thermoscientific.com/dionex Australia (61) 2 9420 5233 China (852) 2428 3282 India (91) 22 2764 2735 Japan (81) 6 6885 1213 Korea (82) 2 2653 2580 Singapore (65) 6289 1190 5 LPN 2867-01 3/11 2011 Thermo Fisher Corporation, Inc.