ß-CYCLODEXTRIN SYNONYMS



Similar documents
α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

SUCRALOSE. White to off-white, practically odourless crystalline powder

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

POLYDIMETHYLSILOXANE

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

ETHYL LAUROYL ARGINATE

MINERAL OIL (MEDIUM VISCOSITY)

ERDOSTEINE - MONOGRAPH.

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

SODIUM CARBOXYMETHYL CELLULOSE

PECTINS. SYNONYMS INS No. 440 DEFINITION DESCRIPTION. FUNCTIONAL USES Gelling agent, thickener, stabilizer, emulsifier CHARACTERISTICS

Fractional Distillation and Gas Chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Laboratory procedures in polymer chemistry

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

GOED VOLUNTARY MONOGRAPH (v. 4)

Tamsulosin Hydrochloride Capsules

SALTS of FATTY ACIDS

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

CERTIFICATE OF ANALYSIS Methyl 4-Hydroxybenzoate

With proper calibration, the upper limit may be extended as needed.

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

105 Adopted:

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Dissolved and precipitated oxalate

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Gas Chromatography Liner Selection Guide

METHOD 8020A AROMATIC VOLATILE ORGANICS BY GAS CHROMATOGRAPHY

23 The Thermal Conductivity Detector

Vitamin C quantification using reversed-phase ion-pairing HPLC

CORESTA RECOMMENDED METHOD Nº 80

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

The basic division explosives for forensic purposes is shown in Fig. 1

Determination of Caffeine in Beverages HPLC-1

Diffusion and Fluid Flow

Expectations for GC-MS Lab

STEVIOL GLYCOSIDES. Chemical and Technical Assessment. Prepared by Harriet Wallin FAO 2004

OREGON GRAPE FOR HOMOEOPATHIC PREPARATIONS BERBERIS AQUIFOLIUM FOR HOMOEOPATHIC PREPARATIONS

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Purification of reaction mixtures using flash chromatography.

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

AMD Analysis & Technology AG

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

NWTPH-HCID. Hydrocarbon Identification Method for Soil and Water

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

[ Care and Use Manual ]

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Theory and Instrumentation of GC Introduction

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Paper Chromatography: Separation and Identification of Five Metal Cations

INSTRUCTIONS Edition AC

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Pesticide Analysis by Mass Spectrometry

Analysis of Vitamin C Using Iodine. Introduction

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Short introduction into. Analytical Chemistry. by Prof. Dr. Manfred Sietz and Dr. Andreas Sonnenberg (PowerPoint slides)

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

Identification of Arson Accelerants by Gas Chromatography

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Melting Point, Boiling Point, and Index of Refraction

Distillation Experiment

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

PHYSICAL SEPARATION TECHNIQUES. Introduction

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Organic Lab 1 Make-up Experiment. Extraction of Caffeine from Beverages. Introduction

Experiment 5: Column Chromatography

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

Chemical Structure of the polymer showing end groups: CH 3 CH 2 CH H

MOISTURE (Karl Fischer, Buffered)

Transcription:

ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-5 mg/kg bw was established at the 44th JECFA (1995) SYNONYMS Beta-cyclodextrin, ßCD, BCD, ß-Schardinger dextrin, cyclodextrin B, INS No. 459 DEFINITION A non-reducing cyclic saccharide consisting of seven alpha-1,4-linked D- glucopyranosyl units manufactured by the action of cyclodextrin transglycolase on hydrolysed starch followed by purification of the ß- cyclodextrin; purification is by preparation of a ß-cyclodextrin/solvent inclusion compound followed by steam-stripping of the solvent before final purification. Chemical names Cycloheptaamylose C.A.S. number 7585-39-9 Chemical formula (C 6 H 10 O 5 ) 7 Structural formula Formula weight 1135.00 Assay Not less than 98.0% of (C 6 H 10 O 5 ) 7 on an anhydrous basis DESCRIPTION Virtually odourless, slightly sweet tasting white or almost white crystalline solid FUNCTIONAL USES Encapsulation agent for food additives, flavouring and vitamins CHARACTERISTICS

IDENTIFICATION Solubility (Vol. 4) Sparingly soluble in water; freely soluble in hot water; slightly soluble in ethanol Specific rotation (Vol. 4) [alpha] 25, D: Between +160 and +164 o (1% solution) Infrared absorption Chromatography The infrared spectrum of the sample corresponds with that of a reference standard. The retention time for the major peak in the liquid chromatogram of the sample solution corresponds to that for ß-cyclodextrin in the chromatograms of the standard solutions prepared as directed in the Method of Assay. PURITY Water (Vol. 4) Other cyclodextrins Residual solvents Reducing substances (Vol. 4) Not more than 14% (Karl Fischer Method) Not more than 2% on an anhydrous basis See description under TESTS Not more than 1 mg/kg of each of toluene and trichloroethylene See description under TESTS Not more than 1% (as glucose) Sulfated ash (Vol. 4) Not more than 0.1% Lead (Vol. 4) TESTS Not more than 1 mg/kg Determine using an atomic absorption technique appropriate to the specified level. The selection of sample size and method of sample preparation may be based on the principles of the method described in Volume 4, Instrumental Methods.. PURITY TESTS Other cyclodextrins Analyses of alpha- and gamma-cyclodextrins are included in the Method of Assay. Adjust the attenuation of the instrument or adjust sample size to obtain a chromatogram in which the ß-cyclodextrin peak height nearly reaches the top of the recording chart. Measure peak heights or peak areas of the alpha-, ß- and gamma-cyclodextrin responses. Calculate % other cyclodextrins (CX) using the formula: Residual solvents A dynamic-headspace gas chromatographic technique is used for the following procedure. The organic volatile impurities are trapped on an absorbent trap and the purge gas is vented. The trapped organic volatile

impurities are desorbed from the trap by heating the trap, and carried into the gas chromatograph by back flushing the trap with the carrier gas. Quantitate each solvent by the technique of standard additions. Purge and Trap Apparatus (The apparatus is based on that described in the US Environmental Protection Agency Test Method for Purgeable Halocarbons - Method 601): The apparatus consists of three separate sections: the sample purge; the trap; and the desorber. The sample purge is designed to accept 5 ml samples with a water column at least 3 cm deep. The gaseous headspace between the water column and the trap has a total volume of less than 15 ml. The purge gas is passed through the water column as finely-divided bubbles with a diameter of less than 3 mm at the origin. The purge gas is introduced not more than 5 mm from the base of the water column. The trap is not less than 25 cm long and has an inside diameter of not less than 2.67 mm. The trap is packed to contain the indicated minimum lengths of adsorbents in the following order, beginning at the trap inlet: 7.7 cm of 2,6-diphenylene oxide polymer (the 2,6-diphenylene oxide polymer is commercially available as TENAX TA), 7.7 cm of silica gel, and 7.7 cm of coconut charcoal. The desorber is capable of rapidly heating the trap at 2500. The trap should not be heated higher than 2500. Condition the assembled trap, prior to initial use, at 2250 overnight with an inert gas at a flow rate of not less than 20 ml per min. Prior to use daily, condition the trap for 15 min at 225º. Standard Solution Accurately weigh 50 mg of trichloroethylene and 50 mg of toluene in a 50 ml volumetric flask. Dilute with methanol. Calibration Solutions Into five 50 ml volumetric flasks, accurately add 0.5, 1.0, 2.0, 3.0, and 5.0 ml of the Standard Solution and dilute with water. These calibration solutions correspond to the concentrations 10.2, 20.4, 40.8, 61.2 and 102 ng per for each solvent. Chromatographic system The purge and trap apparatus is connected to a gas chromatograph with a flame-ionisation detector. Column: capillary column, 30 m, 0.32 mm diameter, 1 micron film thickness of dimethylpolysiloxane oil (such as DB-1, OV-1). Temperature programme: 40º for 3 min, then raise to 220º at 40 per min. Detector: 280º Carrier gas: Helium Purge gas: Nitrogen Flow rate: 40 ml/min Calibration Introduce precisely 20 µl of each calibration solution on the wall (inner side)

of the sample purge. Desorb according to equipment instructions. Record the peak areas. Prepare calibration graphs of peak areas versus weight of each solvent introduced into the purge. Procedure Introduce on the fritted sparger of the sample purge an accurately weighed amount of sample (W), about 250 mg. Purge and desorb according to equipment instructions. Record the peak area of each solvent and read the corresponding weight (X) from the respective calibration curve. Calculation Calculate the amount of each residual solvent by the formula: METHOD OF ASSAY Principle ß-Cyclodextrin is identified by liquid chromatography and quantified by comparison to reference standards containing standard cyclodextrins. Preparation of sample solution Weigh accurately about 500 mg of sample. Add 50 ml of twice-distilled water. Heat and stir until the sample has completely dissolved. Cool, adjust the total volume to 100 ml. Filter on a Millex HA 0.45 µm filter. Preparation of standard solutions Use USP grade alpha- and ß-cyclodextrin. Samples of gamma-cyclodextrin can be obtained from commercial suppliers such as Aldrich Chemical Co. or Sigma Chemical Co. Prepare three standard solutions (S 1, S 2 and S 3 ) containing increasing amounts (mg/kg) of alpha-cyclodextrin, ß-cyclodextrin and gamma-cyclodextrin as follows: S 1 : 2.0 mg/kg A + 3.0 mg/kg B + 2.0 mg/kg G S 2 : 3.5 mg/kg A + 5.0 mg/kg B + 3.5 mg/kg G S 3 : 5.0 mg/kg A + 8.0 mg/kg B + 5.0 mg/kg G where A = alpha- cyclodextrin B = ß-cyclodextrin G = gamma-cyclodextrin Apparatus Liquid chromatograph maintained at a constant temperature of 25 o and equipped with a refractive index detector. Conditions Column - length: 25 cm - diameter: 4.6 mm - packing: 5 µm octadecylsilane bonded to silica (Silica Cl8) with a guard column containing the same packing Solvent: Water: methanol (94:6) Flow rate: 0.7 ml/min

Procedure Inject 10 µl of each of the 3 standard solutions. For each cyclodextrin draw a graph by plotting on the x axis the concentration in g/l and on the y axis the areas of the peaks. Inject 10 µl of the sample solution and determine the area of the eluted ß-cyclodextrin peak. The concentration of ß- cyclodextrin (L g/l) in the sample solution is then read from the graphs. Calculation Calculate the content of ß-cyclodextrin in the sample using the formula: where B = percentage of ß-cyclodextrin in the sample L = the concentration of ß-cyclodextrin in the sample solution as determined under "Procedure" C = the concentration of sample in the sample solution in g/l.