FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

DLO1191 Linear smoke detector

FC722. Fire control panel. Cerberus PRO. FS720 series, IP6

Fire control panel (modular)

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Air damper actuators

FC722 Fire control panel

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Digital input modules

FIREDEX Conventional Fire Panels

RRV934. Multi-controller. Synco living

Cerberus PRO product catalog

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Duct Humidity Transmitter

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

PCS0100en Persy Control Services B.V. Netherlands

Highly flexible the right KNX/DALI gateway for every requirement

TX OPEN RS232/485 module

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Rosemount 333 HART Tri-Loop

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Electronic Control Devices The European Product Catalogue 2007

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

OZW30. Central Unit SYNERGYR

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

VAV compact controller KNX / PL-Link

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

TMS TANK MANAGEMENT SYSTEM

Repeaters and Mimics Data Sheet

CONFIGURABLE SAFETY RELAYS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

CONFIGURABLE SAFETY RELAYS

D287/D288/D292/D293A/D293E

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Digital inductive conductivity transmitter

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Flush-mounted room thermostats

ZC-24DO CANopen I/O Module: 24 Digital Outputs

FC18 Controller(Interlocking) Product Manual

5SV Residual Current Protective Devices

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

PRODUCT CATALOGUE.

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Flush-mount room temperature sensor AQR2531ANW.

RM4TG20 three-phase network control relay RM4-T - range V

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Modular I/O System Analog and Digital Interface Modules

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Triple Waveband Infra-Red Flame Detection

SMART SENSOR COLLECTION

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

PHOENIX CONTACT Features

Rosemount 333 HART Tri-Loop

Frequency Converter Fv

Digital display DA 48

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

LED - Indicator Panels

Temperature & Humidity SMS Alert Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

OZS Web server. For LPB/BSB plants

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Pressure transmitter For general industrial applications Model A-10

Electric Rotary Actuator - On/Off or programmable control actuator

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Variable speed drives

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

Proportional pressure regulators VPPE

Expansion Modules & Accessories

GREISINGER electronic GmbH

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

40.3. Control Relays and Timers

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SYSTEM DESCRIPTION Termination Boards

Model: DC-A2IO Advanced HVAC Controller

Room Temperature Sensors

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

NC-12 Modbus Application

How To Use A Flowmeter

Transcription:

Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input for reporting technical statuses or activating an alarm Input/output module FDCIO221: Control output with potential-free relay contact for activation of alarming devices, fans, air conditioning systems, lift controls, etc. Monitorable contact input for reporting technical statuses or activating an alarm Use as a monitored output with a separate power supply, e.g., for operating acoustic signal transmitters LED indicator for input/output statuses and for fault, test, localization Power supply and communication via (addressed individually) Address automatically issued during commissioning Two-wire installation for all cable types 2016-05-23 Control Products and Systems

Properties Functions Features Transparent housing, ensuring that indicators are easy to see Protected electronics Integrated line separator Chronological status monitoring Supply via, auxiliary supply only required if the output is configured as monitored (FDCIO221) Microprocessor-controlled signal processing Different mounting options For dry areas In humid environments, use additional housing FDCH221 Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated FDCI221 input module Input for potential-free detector contact Monitoring the input line for open line and short-circuit with terminating resistors The input for status or alarm messages can be configured using the fire control panel. Status indicator by means of LED Fields of application: To activate a potential-free normally open or normally closed contact in order to report technical statuses (e.g., door or fan control) or to activate an alarm (e.g., sprinkler alarm) 2 1 3 1 Potential-free detector contact 3 Connections for the detector line 2 Connections for the input 2

FDCIO221 input/output module Input for potential-free detector contact Monitoring the input line for open line and short-circuit with terminating resistors The input for status or alarm messages can be configured using the fire control panel. Output which can be configured via jumper: Not monitorable: Potential-free relay contact (AC 22 V, 2 A or DC 30 V, 2 A) Monitorable: Relay contact (DC 30 V, 2 A) Status indicator by means of LED Fields of application: To activate a potential-free normally open or normally closed contact in order to report technical statuses (e.g., fan control) or to activate an alarm (e.g., sprinkler alarm) For decentralized activation of alarming devices, fans, air conditioning systems, lift controls, etc. 2 1 4 3 1 Potential-free detector contact 3 Connections for the detector line 2 Connections for the input 4 Connections for the output 3

Type Overview Type Designation Order number Weight [kg] FDCI221 FDCIO221 Input module incl. 2 resistors, 2 mounting feet Input/output module incl. 2 resistors, 2 mounting feet S54312-F1-A1 0.060 S54312-F2-A1 0.066 Accessories for input module FDCI221, input/output module FDCIO221 Type Designation Order number Weight [kg] FDCH221 Housing with cover, seal, and screws S54312-F3-A1 0.282 M20 x 1.5 metal cable gland A5Q00004478 0.036 M20 metal counter nut A5Q00004479 0.006 DBZ1190-AB 1.0 2.5 mm 2 (3-pin) connection terminal BPZ:4942340001 0.001 Replacement material for input module FDCI221, input/output module FDCIO221 Type Designation Order number Weight [kg] FDCM291 Mounting foot A5Q00003855 0.001 Product documentation Document ID Name 008164 Equipment overview Sinteso Detector system FD20 A6V10225323 Equipment overview Cerberus PRO Detector system FD720 008331 List of compatibility (for 'Sinteso ' product line) A6V10229261 List of compatibility (for 'Cerberus PRO' product line) A6V10211122 Technical Manual Input module FDCI221, input/output module FDCIO221 A6V10212086 Installation Input module FDCI221, Input/Output module FDCIO221, Housing FDCH221 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download 4

Notes Mounting Mounting options Directly on the mounting surface Series mounting on a U-rail TS35 Surface-mounted or recess-mounted cable entry In housing FDCH221 (accessory) with cover, seal, and screws for wet areas 1 3 2 1 Series mounting using mounting feet supplied, on U-rail TS35 2 Mounting in housing FDCH221 (accessory) 3 Use auxiliary terminals DBZ1190-AB for shielded cables Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data Operating voltage FDCI221 FDCIO221 DC 12 33 V Operating current (quiescent) Max. 0.3 ma Max. 0.4 ma Relay output (ohmic) - AC 22 V, 2 A, max. 44 VA DC 30 V, 2 A, max. 60 W Line resistance (input) Max. 20 Operating temperature -25 +70 C Storage temperature -30 +75 C Air humidity Communication protocol Connection terminals Color Housing Cover Housing FDCH221 Protection category (IEC 60529) When mounted on a U-rail in a fire control panel With housing FDCH221 95 % rel. 0.2 2.5 mm² ~RAL 9010, pure white Transparent matt ~RAL 9010, pure white Standards EN 54-17, EN 54-18 Approvals VdS LPCB FM DNV GL (Marine) System compatibility FDnet C-NET G209066 531h/01 3038448 IP30 IP65 59 825-13 HH FS20 FS720 G209067 531h/02 3038448 6

Dimensional drawings Input module FDCI221 71 24 95 91 Input/output module FDCIO221 71 24 95 91 Housing FDCH221 119 54 207 7

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2009 Technical specifications and availability subject to change without notice. 8 Document ID Manual FD20/FD720 Edition 2016-05-23 Register 5