intelligent solutions



Similar documents
W 36: Mastering complex tasks reliably

W150: Miniature photoelectric switch series with completely integrated electronics

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

LUT Luminescence scanners: Seeing what no-one else can

W 160: Miniature series for optimum solutions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Color Mark Sensor with Red or Green LED E3S-VS

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

V180-2 M18 Cylindrical Photoelectric Sensor Series

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

For accurate positioning in warehouse and conveying areas

photoelectric highlights

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Universal Voltage Terminal Photoelectric E3JM

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Overview. Application Areas. DMP Position Finder

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

technical data (according to IEC )

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Electrical connection

How To Read A Pipe From A Sensor

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

BOS 73K... BOS 74K...

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

New XUY roller sensors

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Capacitive Prox E2K-X

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Inductive Proximity Sensors

How To Make An Ultrasonic Sensor

Color sensors CS8, CS8-1

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

Cross-beam scanning system to detect slim objects. 100 mm in

Smart Sensing Solutions Since 1954

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Multifunction devices

ACS-30-EU-EMDR-10-MOD

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

FIRERAY 2000 Installation Guide

Liquid Level Limit Switch liquiphant T FTL 20

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Electronic Pressure Switch EDS 300

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

Turbine Flow Sensor Series VTR

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Speed Control Relays SX2

Magnetic proximity switches

Series 8146/5-V37 and Series 8150/5-V37

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Electronic Pressure Switch EDS 3000

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Inductive sensor NI10-M18-Y1X-H1141

Rotary actuators Rotary wing drives Series RAK. Brochure

Adjustment functions for both span and shift have been incorporated

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

E3T Miniature Photoelectric Sensors

Fiber-Optic Photoelectric Sensor

Digital display DA 48

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Instruction Manual Service Program ULTRA-PROG-IR

Incremental Rotary Encoder E6B2

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

ALARMLINE ANALOGUE Linear Heat Detection System

crm+25/d/tc/e Extract from our online catalogue: Current to:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Givare NC-SRS 280 och 880

Transcription:

Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology for intelligent solutions Furthermore, the devices also incorporate a large number of features that are usually only found in special versions, e.g. the test input of the WS/WE 8- and WL 8-, the adjustable scanning distance with background suppression of the WTV 8-, individual plugs, or status LEDs as signal strength indicators, alignment aids, or prefailure signalling output. 0 SENSICK CATALOGUE TThe W 8- series of photoelectric switches is ideal for handling systems as well as for packaging machines and other complex tasks. WT 8- photoelectric proximity switches, WL 8- photoelectric reflex switches, or WS/WE 8- through-beam photoelectric switches thanks to their glass-fibre-reinforced and fully welded plastic housing, all of these sensors have the robustness required for industrial applications. Extremely large scanning ranges are an additional feature: up to 0 metres for the throughbeam photoelectric switch, up to metres for the photoelectric reflex switch and 00 mm or 00 mm for the photoelectric proximity switch (depending on whether a red light or infrared light source is used). The WTV 8- photoelectric proximity switch has been specially developed for and with the packaging industry. Its features include: its broad optical basis, internally adjustable optics, stateof-the-art electronics, powerful background suppression and optimised light spot geometry which together provide a previously unattainable level of immunity against ambient reflections. The detection of plastic bags on a conveyor belt, glossy and differently sized coffee packets or drinks cartons before being packed, cakes packed in plastic film on a stainless steel chain conveyor, or drinking straws attached to drinks containers all of these tasks can be mastered without any problem with the WTV 8-.

WL - W 8- m WTV 8- sensors used to check the presence of objects along the individual lanes of a packaging line for packs of coffee. b Transparency poses no problems: the WL 8- photoelectric reflex switch monitors the edges of packaging film. v Is the packaging unit complete? WT 8- photoelectric proximity switches provide us the answer. n Leak test for plastic bottles: WT 8- sensors used to check the presence of test objects in the automatic machine. SENSICK CATALOGUE

WT 8- Photoelectric proximity switches, background suppression, infrared light -- DC 0...00 mm Photoelectric proximity switches Adjustable background suppression Insensitive to ambient light sources (HF lamps, flashing alarm lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C Fast response time Dimensional drawing 0. max... 0 0.. Adjustments possible WT 8-P WT 8-N WT 8-P WT 8-N WT 8-P 0 WT 8-N 0 WT 8-P 0 WT 8-N 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment Alignment sight C V WT 8-P WT 8-P WT 8-N WT 8-N WT 8-P 0 WT 8-P 0 WT 8-N 0 WT 8-N 0 Accessories page Cable receptacles 9 Mounting brackets 0 x. mm -pin, M -pin red brn gra blk ora wht SENSICK CATALOGUE

WT 8- Technical data WT 8- P P P 0 P 0 N N N 0 N 0, max. typical 0...00 mm, adjustable Light source ), light type Light spot diameter LED, infrared light 0 mm at 00 mm Supply voltage V S Ripple ) Current consumption ) 0...0 VDC V SS < ma < ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. V S NPN; signal voltage LOW <. V Response time ) < 00 µs Max. switching frequency ) 00/s Cable ), m Cable ), m VDE protection class 8) Circuit protection 9) Plug V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression 0 00 0 00 0 00 0 (mm)00 00 00 00 00 00 00 on black, % remission on grey, 8 % remission on white, 90 % remission % of scanning distance 0 0 0 Order information Type WT 8-P WT 8-P WT 8-P 0 %/90% WT 8-P 0 WT 8-N WT 8-N WT 8-N 0 WT 8-N 0 8%/90% 90%/90% 0 (mm) 00 00 00 00 00 00 00 Part no. 0 88 0 890 0 89 0 900 0 89 0 88 0 88 0 9 SENSICK CATALOGUE

WT 8- Photoelectric proximity switches, background suppression, red light -- DC 0...00 mm Photoelectric proximity switches Adjustable background suppression Insensitive to ambient light sources (HF lamps, flashing alarm lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C Fast response time Dimensional drawing 0. max... 0. 0. Adjustments possible WT 8-P WT 8-P 0 WT 8-N WT 8-N 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment Alignment sight C V WT 8-P WT 8-N WT 8-P 0 WT 8-N 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin, M red brn gra blk ora wht SENSICK CATALOGUE

WL - WT 8- Technical data WT 8- P P0 N N0, max. typical 0...00 mm, adjustable Light source ), light type Light spot diameter LED, red light mm at 00 mm Supply voltage V S Ripple ) Current consumption ) 0...0 VDC V SS < ma < ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. V S NPN; signal voltage LOW <. V Response time ) < 00 µs Max. switching frequency ) 00/s Cable ), m Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression 0 00 0 00 0 00 0 Order information Type WT 8-P WT 8-P 0 WT 8-N WT 8-N 0 Part no. 0 89 0 89 0 88 0 88 0 (mm)00 00 00 00 00 00 00 0 %/90% on black, % remission on grey, 8 % remission on white, 90 % remission % of scanning disatnce 8%/90% 0 90%/90% 0 (mm) 00 00 00 00 00 00 00 SENSICK CATALOGUE

WT 8- Photoelectric proximity switches, short range, background suppression, red or infrared light -- DC 0...0 mm Photoelectric proximity switches Adjustable background suppression Insensitive to ambient light sources (HF lamps, flashing alarm lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C Fast response time Dimensional drawing 0. max... 0. 0. Adjustments possible WT 8-P WT 8-P 0 WT 8-P 8 WT 8-P 80 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment Alignment sight C V WT 8-P WT 8-P 8 WT 8-P 0 WT 8-P 80 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin, M red brn gra blk ora wht SENSICK CATALOGUE

WL - WT 8- Technical data WT 8- P P 0 P 8 P 80 0... 0 mm, adjustable Light source ), light type Light spot diameter LED, red light LED, infrared light 0 mm at 00 mm Supply voltage V S 0...0 VDC ) Ripple ) V SS Current consumption ) < ma Switching outputs PNP, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V Response time ) < 00 µs Max. switching frequency ) 00/s Cable ), m Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression 0 00 0 0 0 0 0 (mm) 00 00 00 0 %/90% Order information Type WT 8-P WT 8-P 0 WT 8-P 8 WT 8-P 80 Part no. 0 09 0 0 0 0 on black, % remission on grey, 8 % remission on white, 90 % remission % of scanning distance 8%/90% 90%/90% 0 (mm) 00 00 00 SENSICK CATALOGUE

WT 8- Photoelectric proximity switches, long range, background suppression, infrared light -- DC 0...000 mm Photoelectric proximity switches Adjustable background suppression Insensitive to ambient light sources (HF lamps, flashing arlam lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C Fast response time Dimensional drawing 0. max... 0 0.. Adjustments possible WT 8-P WT 8-P 0 Standard direction of the material being scanned LED signal strength indicator Optical axis, sender Optical axis, receiver Mounting hole l. mm adjustment Alignment sight C V WT 8-P WT 8-P 0 Accessories page Cable receptacles 9 Mounting brackets 0 x 0. mm -pin, M red brn gra blk ora wht 8 SENSICK CATALOGUE

WL - WT 8- Technical data WT 8- P P0 0...000 mm, adjustable Light source ), light type Light spot diameter LED, infrared light 0 mm at a distance of 00 mm Supply voltage V S 0...0 VDC ) Ripple ) V SS Current consumption ) < ma Switching outputs PNP, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V Response time ) < 00 µs Max. switching frequency ) 00/s Cable ), m Plug VDE protection class 8) Circuit protection 9) V A, B, C Enclosure rating IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression 0 00 0 00 0 000 0 %/90% Order information Type WT 8-P WT 8-P 0 Part no. 0 9 0 99 0 (mm) 00 00 00 800 000 0 on black, % remission on grey, 8 % remission on white, 90 % remission % of scanning distance 0 0 8%/90% 90%/90% (mm) 00 00 00 800 000 SENSICK CATALOGUE 9

WTV 8- Photoelectric proximity switches, background suppression, infrared light -- DC 0...0 mm 00...00 mm Photoelectric proximity switches Dimensional drawing Adjustable background suppression Detection of objects with shiny surfaces Insensitive to ambient light sources (HF lamps, flashing alarm lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C.8. 8 max..... 0 8 Adjustments possible WTV 8-P 0 WTV 8-P 0 8 Centre of optical axis, sender, WTV 8-P 0 Centre of optical axis, sender, WTV 8-P 0 Standard direction of the material being scanned Receiving range Mounting hole l. mm adjustment Alignment sight Status indicator C V Connection type WTV 8-P 0 WTV 8-P 0 Accessories page Cable receptacles 9 Mounting brackets 0 -pin, M brn blk wht 80 SENSICK CATALOGUE

WL - WTV 8- Technical data WTV 8- P0 P0 0...0 mm, adjustable 00...00 mm, adjustable Light source ), light type Light spot diameter LED, infrared light 8 mm at 0 mm 8 mm at 00 mm Supply voltage V S 0...0 VDC ) Ripple ) V SS Current consumption ) < 0 ma Switching outputs PNP, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<. V) NP; signal voltage LOW Approx. 0 V Response time ) ms Max. switching frequency ) 0/s Connection type Plug VDE protection class ) Circuit protection 8) V A, B, C Enclosure rating IP Ambient temperature T A Operation C...+0 C Storage C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage 0 V DC 8) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression 0 0 0 00.. %/90% Order information Type WTV 8-P 0 WTV 8-P 0 Part no. 0 98 0 0 (mm) 0 0 0 80 00 0 0 0 80 00 on black, % remission with P 0 on black, % remission with P 0 % of scanning distance. %/90%.0 0.8 0. 0. 0. 0 (mm) 80 00 0 0 0 80 00 SENSICK CATALOGUE 8

WL 8- Photoelectric reflex switches, red light -- DC Scanning range m Photoelectric reflex switches Dimensional drawing. Insensitive to ambient light sources (HF lamps, flashing alarm lamps) No mutual interference if devices are installed opposite each other Operating temperature -- 0 C...+0 C Fast response time Test input for system diagnosis, optional Autocollimation system max. 0.. 0.. Adjustments possible WL 8-P WL 8-N WL 8-P WL 8-N WL 8-P 0 WL 8-N 0 WL 8-N 0 Centre of optical axis LED signal strength indicator Mounting hole l. mm Sensitivity adjustment Alignment sight C V WL 8-P WL 8-P WL 8-N WL 8-N WL 8-P 0 WL 8-N 0 WL 8-P 0 WL 8-N 0 Accessories page Cable receptacles 9 Mounting brackets 0 Reflectors 0 x 0. mm -pin, M -pin red brn gra blk ora wht trq 8 SENSICK CATALOGUE

WL - WL 8- Technical data WL 8- P P P0 P0 N N N0 N0 Scanning range, max. typ./on reflector m/pl 80 A Sensitivity adjustable Light source ), light type LED, red light Light spot diameter 0 mm at m Supply voltage V S 0...0 VDC ) Ripple ) V SS Current consumption ) < ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. V S NPN; signal voltage LOW <. V Response time ) /Max. switching freq. ) < 00 µs; 000/s Test input TE PNP, sender OFF Test input to 0 NPN, sender OFF Test input to V+ Cable ), m Cable ), m VDE protection class 8) Circuit protection 9) Plug V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Polarising filter Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression Scanning range and operating reserve 0 0 0 0 0. 0 0..8... 00 0 Operating distance Order information Type WL 8-P WL 8-P WL 8-P 0 WL 8-P 0 WL 8-N WL 8-N WL 8-N 0 WL 8-N 0 Part no. 0 90 0 90 0 908 0 9 0 90 0 9 0 90 0 0 0(m) Operating range Reflector type PL 80 A C 0 PL 0 PL 0 A PL 0 A PL 0 A Reflective tape Diamond Grade Scanning range, max. typical Operating range 0...0 m 0...0 m 0...0 m 0...0 m 0... m 0...0 m 0...0 m Operating reserve (m) Scanning distance, max. typical SENSICK CATALOGUE 8

WS/WE 8- Through-beam photoelectric switches, red light -- DC Scanning range 0 m Through-beam photoelectric switches Dimensional drawing. Insensitive to ambient light sources (HF lamps, flashing alarm lamps) Operating temperature -- 0 C...+0 C Fast response time Test input for system diagnosis max.. 0... 0 Adjustments possible WS/WE 8-P WS/WE 8-N WS/WE 8-P 0 WS/WE 8-N0 WS/WE 8-P 0 Centre of optical axis Operating voltage indicator, green (WS) LED signal strength indicator, yellow (WE) Mounting hole l. mm Sensitivity adjustment Alignment sight WS/WE 8-P WS/WE 8-P 0 WS/WE 8-P 0 WS/WE 8-N WS/WE 8-N0 C V x 0. mm -pin, M -pin Accessories page Cable receptacles 9 Mounting brackets 0 Sender red brn wht trq blk Receiver red gra ora brn blk wht L+ Q Q M NC NC 8 SENSICK CATALOGUE

WL - WS/WE 8- Technical data WS/WE 8- P P 0 P 0 N N0 Scanning range, max. typical Sensitivity 0...0 m adjustable Light source ), light type LED, red light Light spot diameter Approx. 0 mm at m Angle of dispersion Approx.. Supply voltage V S 0...0 VDC ) Ripple ) V SS Current consumption ) < 0 ma sender without heating < ma receiver without heating < ma Switching outputs PNP, Q and Q NPN, Q and Q Output current I A max. 00 ma PNP; signal voltage HIGH V S (<.9 V) PNP; signal voltage LOW Approx. 0 V NPN; signal voltage HIGH Approx. V S NPN; signal voltage LOW <. V Response time ) 00 µs Max. switching frequency ) 000/s Test input TE sender OFF Test input to 0 V Connection type Cable ), m VDE protection class 8) Circuit protection 9) Plug V A, B, C Enclosure rating IP IP Ambient temperature T A Operation 0 C...+0 C Storage 0 C...+ C Weight Approx. 00 g Housing material ABS, acrylonitrile butadiene styrene ) Average service life 00,000 h at T A = + C ) Limit values ) May not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Do not bend below 0 C 8) Reference voltage 0 V DC 9) A = V S connections reverse-polarity B = Output Q and Q short-circuit C = Interference pulse suppression Scanning range and operating reserve 0 0 0(m) 8 0 Operating range Scanning range, max. typical 000 00 Order information Type WS/WE 8-P WS/WE 8-P 0 WS/WE 8-P 0 WS/WE 8-N WS/WE 8-N0 Part no. 0 9 0 9 0 98 0 9 0 9 0 Operating reserve 0 (m) 8 0 SENSICK CATALOGUE 8