Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications



Similar documents
STAGE SPECIFICATIONS. Newberry Opera House

Event Planner/Venue Specialist Phone:

SHUBERT THEATER 247 College Street, New Haven, CT

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

THEATRE USER INFORMATION GUIDE

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

TECHNICAL SPECIFICATIONS Paramount website: Paramount

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

MEETING PACKAGES 400 LEVEL

Meydenbauer Center Audio Visual Services & Price Guide. Provided by Audio Visual Factory Inc.

PRODUCTION SPECIFICATIONS

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

TECHNICAL SPECIFICATIONS.

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

CENTER THEATER TECHNICAL SPECIFICATIONS 404 SEAT PROSCENIUM THEATER WITH FLY LOFT

the audio/video + lighting menu

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

Special Events & Space Rentals

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay

Theater One (Upper level)

Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

CONCERT HALL TECHNICAL SPECIFICATIONS

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

TEATR GROTESKA ul. SKARBOWA KRAKÓW TEL groteska@groteska.pl Update

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

Use of Facilities Agreement/User Contract Saemann Student Center, Conferences & Events

Production Services Department

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Lower Level (Level L) Exhibit Halls A, B & C

The Civic Hall in Bedworth Technical Specification

Auditorium Audiovisual System User s Guide

TECHNICAL SPECIFICATIONS

Theatre Manager: Linda Aitken (03) ,

Technical Information. Policies & Procedures. Fee Schedule for Rental & Services

Introduction. Meeting Spaces. Hynes Audio Services

Artist: Michael and Amy Rider: Corporate - Grand Pianos

Theaters Tilburg - Concertzaal. Address

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

B R O W N U N I V E R S I T Y

Blair School of Music

A1.5 Classroom Standards

Main Library Meeting Room Use

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

Reynolds Performance Hall Facility Regulations and Fee Schedule

PRODUCTION SPECIFICATIONS THE MANÈGE (RIDEHUSET)

Perth Concert Hall. Technical and Production Information

Audio/Visual Services

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

Rental Policy & Pricing 2013

Theaters Tilburg - Concertzaal. Address

Brochure Event Production Suppliers Office Contact Sub Audio 2014

Scottsdale Center for the Performing Arts Season STAGE 2 TECHNICAL INFORMATION

Technical Specifications Version

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

STAGE TERMS GLOSSARY

Fort Morgan Band Shell: Audio Systems Design Narrative

GUSMAN CONCERT HALL INFORMATION PACKAGE

Cole 100 Auditorium. Equipment Use Instructional Guide

TECHNICAL RIDER

CAD STANDARDS Version 2 VENUE AND PRODUCTION DRAWINGS

One of the most incredible places on earth, Rolling Stone Magazine

For sale. State-of-the-Art Office Building Custom Designed for Film & Sound Post Production. 352 South 500 East Salt Lake City, UT 84102

Robsham Main Stage Venue Information Packet (V.I.P) Updated

A supervisor with a professional staff is present at all times to respond to requests.

Service Charges & Price List 2014

ADA HOTEL SITE INSPECTION CHECKLIST

1. Introduction. MagicQ Visualiser. MagicQ for Windows, Mac and Linux includes the MagicVis visualiser

SOLUTION GUIDE AUDI TOR IUM. Audio Visual System Solutions for Business. HARMAN Professional Solutions Brands:

The Theatre Dictionary

The Future of Lighting and Power Distribution in Theatre Design.

TECHNICAL SERVICES GUIDE

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

UMD School of Music Degree-Required Recitals Gildenhorn and Ulrich Recital Hall Policy Manual Spring 2015

EAST TENNESSEE STATE UNIVERSITY FINE ARTS CLASSROOM BUILDING SBC NO. 166/ PROGRAM CONFIRMATION AND REFINEMENT SESSION NO.

PA and Lighting Packages - Ready to Go

Sweet Adelines Microphone and Sound System Guidelines

CLASSROOM TECHNOLOGY GUIDE

SYDNEY OPERA HOUSE (Bennelong Point) GPO BOX 4274 SYDNEY NSW 2001 AUSTRALIA

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

Aria Technical Services Price Book

Transcription:

Douglas J. Cardinal Performing Arts Centre Information and Technical Specifications Location 10726 106 Ave., Grande Prairie Alberta North wing of Loading Dock is at the North end of the passenger drop-off Capacity The DJC seats a maximum of 508 patrons. This number is modified by use of the main level audio position or wheel chair patrons. Technical Overview The theatre is equipped with professional dimming, lighting, video/data and audio reinforcement equipment. For all users the DJC will come with a supervising technician and a Front-of-House Coordinator. All rigging is done by genie lift or from the catwalks. There is no Fly Gallery. Please talk to theatre personnel about any and all rigging prior to load-in. The Theatre reserves the right to limit, change or veto any rigging requests. The Theatre does not have rigging equipment available for show use. Extra crew may be requested / required for set-up, tear-down or show support and additional fees will apply. Additional rooms, rehearsal spaces or storage spaces are available but must be pre booked. Stage Dimensions & info Main curtain (full opening ~80, normal ~44 ). Working area ~60 w X 43 d including 13 stage level, semi-thrust style, orchestra pit. Wings are ~24 with 8 fully hidden. There is no crossover within the theatre, but the hallway behind the theatre can be used. Floor is not sprung but is ~3 lap d wood with a plywood deck. Top surface is painted Masonite, matte black. Orchestra pit, downstage of main curtains. (not currently movable) The Theatre does not presently have any working trap doors in the floor. A Rosco dance floor that fills main area can be made available within negotiations. 4 usable wing entrances when using full stage. 2 usable wing entrances with Mid-Stage traveler closed. Leg spacing is approximately 5. AKA: GPRC Theatre, College Theatre, DJC Theatre Accessibility: Dedicated, with excellent sightlines, wheelchair and mobility restricted seating IR hearing assistance for both headset and hearing aids DJCPAC Information and Technical Specifications 2011 Page 1

Soft Goods: All curtains are on hard mounted tracks. All tracks follow curve of theatre stage. Teaser, Tormentors & Borders do not move. Mains are red velour, Centre split, 44 normal opening, Motor Driven, speed is 2 / sec. 3 sets of legs and borders, black velour, 12 wide, manually drawn. 2 sets of travelers and borders, black velour, centre split, manually drawn o 1 Mid-stage, 1 up-stage concealing Cyc. Sky Cyc, 50 x26 is 24 from upstage wall. Video projection Screen, 24x24 motor driven is ~4 upstage of Main curtains. Dressing Rooms 2 x 6 person Dressing rooms are available under the stage area. Access is via a Spiral stairwell in back hall. Complete with full showers, washrooms, makeup mirrors, & program sound. No elevator is available. Additional Classrooms in the area may be arranged to assemble large groups of people. Greenroom Back Stage Right. Complete with chairs, table, sink, small fridge, and small mirror. Program Sound, and stage video are available. Shop The shop is currently not available for use. Special Effects Any and all special effects must be cleared with the Theatre personnel prior to set-up. The Theatre reserves the right to control, change, limit or veto any and all special effects. Controlled Special effects shall include but not be limited to smoking, live flame, pyrotechnics, flying, stage fights, sword play, smoke or fog, and any electrical devices. Permission will be granted to most well thought out and safe effects. Full federal permits & licenses must be produced for any pyrotechnical effect. Loading Area A standard trailer height loading dock is available stage level - USL. Standard double loading doors. Lobby doors are standard double man doors. Green room doors are standard double man doors with a 120 deg turn. Control Booth Booth Location is back of upper balcony, full opening windows. Access is via Grid or thru the main house. No external (easy) access is available from stage. The booth contains the main control of all lights, sound and main curtain. No elevator access is available. The in-house mix position is back of house under the balcony. Use of in-house mix position will reduce seating by ~8. DJCPAC Information and Technical Specifications 2011 Page 2

Lighting House Standard Plot A standard multi-purpose plot remains hung and programmed for easy operation with sub-masters which includes: Warm and Cool front wash 3-colour + white top wash (LED RGB color mixing) Magenta and green tips (green with forest breakup gobos) LED RGBA color mixing cyc lights 2 Martin SmartMAC s hung on truss GPRC logo gobo on entrance floor Gobo d curtain warmers focusable specials - 8 pre-hung from FOH & 6 onstage Specials for standard conductor position (DCS) and podium (SR) Lighting Console ETC ION Multi universe, computer style programing Full integrated control of our conventional, LED and moving lights Dimmers 192 Control Lighting Quad 2.4 Kw Dimmers (DMX 512) 6 Non-dims (non-operational) 5 House light zones (overhead and floor/stairs) DMX control Booth, Back SL, and Mix location are possible. Circuits Almost Dimmer per circuit. 20 amp new style twist lock outlets. Circuits are shared or repeated at various lighting positions. (pre-circuiting is not suggested, due to unconventional circuit placement) Lighting Positions NOTE: All lighting pipes follow curve of the theatre and stage. Stage pipes @ 20 from deck. (see section drawing) 3 fixed onstage lighting pipes w/circuits every 18 along lighting positions. (cir. shared) 2 fixed FOH lighting pipes w/circuits every 18 along lighting positions (cir. shared) 1 Flown FOH truss above orchestra pit 2 bridges in the FOH (12 cir. shared) 2 balcony corners (4 cir. shared) 2 Under balcony locations (4 cir.) 3 wall pockets FOH edge of stage DJCPAC Information and Technical Specifications 2011 Page 3

Instrument Inventory LIGHT * watts Hung Available ALTMAN 1000q Follow Spot ZOOM 1000 2 ALTMAN 1KL6020-40 20-40 1000 6 STRAND IRIS 4 CYC 1000 0 retired ETC SOURCE 4 10 750 4 ETC SOURCE 4 19 750 18 ETC SOURCE 4 36 750 14 ETC SOURCE 4 50 750 6 2 PARNel 750 33 FRESNEL 8" 750 8 0 GForce LED cyc bars Coloradio 2 LED Fresnels 25 Martin MX10 scanners 2 Martin SmartMAC 2 House Lighting Incandescent Pot house lights, dimmers controllable through lighting console or manual stations Fluorescent architectural/house lights, Manual control from booth & FOH. LED stair and seat level safety lighting. Onstage Power 2 onstage non-switched 20 amp AC outlets (shared on either side of the stage.) 50 amp 240v range plug. Location Stage Left. ( 12 cir distro-panel available on request) Full 200 amp 3 phase tie-in available - Stage Left. (No house tails). NO RV / Bus power currently available. DJCPAC Information and Technical Specifications 2011 Page 4

Sound Equipment House System an Allan & Heath ilive T112 48x24 Digital console. Yamaha 01V96 digital console in storage, 16 channels. 24x8 hardwired audio snake from SL (to booth patch bay) to FOH mix position. o 24 channels monitor tail w/ ground lifts. 15 additional mic lines from separate audience areas. (see plot) Main Speakers JBL VRX928LA flown speaker array with JBL VRX918S floor mounted subwoofers and dedicated Crown amplifiers. Stage Monitor system 2 TOA HX5 line arrays permanently flown sidefills (dance monitors) 4 JBL SRX 712m monitors DBX 1231 graphic EQs. Crown amplifiers. Available On-stage Monitor mix / audio rig Allen & Heath Mix Wiz 14:4:2. Denon DNT Cassette / CD player Audio Sources CD, MP3 and computer playback available in the booth. We use Shure SLX2 wireless mics. 4 units available. (2 handheld, 4 lav, 1 headset) Some specialty gear may be available on request. o 2x Shure Beta58A, Beta57A o Countryman Isomax 4 podium mic. Other Equipment Available Intercom System Clear Com Single channel system for booths, follow spot, in-house sound and onstage positions. Program Sound/Video Systems Program Sound to booths, greenroom, dressing rooms, shop area and offices. Program Video to greenroom, lobby, booths and onstage. Video/Projection Equipment 4000 lumen Eiki Data/video projector installed in main level booth. 1024x768 pixel resolution. o Stage and booth computer hookup. (DVD playback from booth only.) Piano The College Theatre presently has a 7.5 grand piano onsite. Pampered and maintained but Tuned upon request Podium Lectern/Podium, with mic and laptop connection to main projector is available. NOTE: Ideally, all equipment and systems mention are available for use in the Theatre. BUT, please contact technical staff for an updated list of any equipment NOT available. DJCPAC Information and Technical Specifications 2011 Page 5