BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000



Similar documents
Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Manual. Solar Fountain Mobile Phone Charger

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Copyrights 2010 Victron Energy B.V. All Rights Reserved

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

SNMP Web Management. User s Manual For SNMP Web Card/Box

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

Solar Controller / Battery Charger User s Manual

Manual. VE.Bus to NMEA 2000 interface

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

View Star series. Solar Charge Controller INSTRUCTION MANUAL

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.

2 Installation Explanation

User Manual. Humidity-Temperature Chart Recorder. Model RH520

PSC-A5 Solar Charge Controller Manual

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Manual WatchPower

MAGICAR M871A. Car alarm with two-way remote User s guide

How To Control A Battery Cell Phone With A Battery Power Control System

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

GSM Alarm System User Manual

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

12 Volt 30 Amp Digital Solar Charge Controller

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Portable Solar Kits Owner s Manual

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Phocos CXCOM for CX and CXN Instruction Manual

User s Manual. Management Software for Inverter

Advanced Wind/Solar Hybrid Controller. Model: WWS10A-48 Version 1.0

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

User Guide. Temperature and Humidity Datalogger. Model 42280

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

SOLAR POWER - THE NEW WAY TO RV!

STERILIZERS, LABORATORY DRYING OVENS

Back-UPS Pro 1300/1500 Installation and Operation

Mass Charger Alarm Interface GMDSS - Global Maritime Distress & Safety System

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

itracer Series Maximum Power Point Tracking Solar Charge Controller OPERATION MANUAL

PD 100A. Printing data system

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Communication bridge Xcom-MS User Manual

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

How To Use A Power Supply Unit (Upu)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

E E V R E - R S - O S L O A L R

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Automatic start of a generator

GSM Autodialer Professional GJD700 Speech & Text Autodialer

TMS TANK MANAGEMENT SYSTEM

9452/9453 Installation and User Guide

FIREDEX Conventional Fire Panels

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

Auto Dialer. Manual E-921APQ E-921GPQ

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

TS510 & TS500. Installation & User Guide. Compatible Equipment

Installation and Operation Back-UPS 1250, 1300, 1500

DAB+ / FM Tuner Model: TU-201

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

HyperAccess Access Control System

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

INSTALLATION MANUAL XM3 Reader

Controller Automation, Model II+

Setting Up the ZigBee Ethernet Gateway

DC Electronic Loads 8500 series

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Manual for Fire Suppression & Methane Detection System

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

G-100/200 Operation & Installation

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Intelligent GSM Auto-Dial Alarm System

Energy Communication Unit (ECU)

AMS-1000 Multi-Channel Air Management System for Boost Control

HDfury 3D Glasses and Emitter. User Manual Rev 1.0

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

9448 Installation and User Guide

500r+ Installation and User Guide

Multi Media Cable Tester TM-901N/TM-902/TM-903

IN-OUT Thermometer with Cable Free Sensor and Clock

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

User s Manual for Fingerprint Door Control Software

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

INSTALLER S & OWNER S MANUAL

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

PRT3 Printer Module: ASCII Protocol Programming Instructions

Transcription:

Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000

Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product features... 3 3.1 General... 3 3.2 Display... 5 3.3 Buttons... 6 4. Monitoring... 6 5. Full setup details... 8 5.1 Main menu... 8 5.2 Device Information... 8 5.3 Test Operation... 8 5.4 Control Parameters... 9 5.5 Load Settings... 10 5.6 Device Parameters... 12 5.7 Device Password... 12 5.8 Charge mode... 12 5.9 Factory reset... 12 5.10 Failure Information... 13 5.11 Meter parameters... 13 6. Technical Specifications... 13 7. RS485 connector pinout... 13 8. Dimensions... 14 1

1. Important safety instructions Read all instructions before starting the installation. Keep the controller away from rain, exposure, severe dust, vibration, corrosive gas and intense electromagnetic interference. 2. Installation Please see section 8 for mounting dimensions Connection to the BlueSolar PWM-Pro charge controller: The panel must be connected to the controller with a standard RJ45 UTP cable. 2

3. Product features 3.1. General EN Warning LED Audible Alarm Communication LED Display LCD screen Buttons 3

RS485 communication and power interface Warning LED The warning indicator LED flashes in case of failure of the connected charge controller. Audible alarm The audible failure alarm can be activated or deactivated. Communication LED Indicates communication status when the display is connected with the charge controller. 4

3.2. Display After connecting the remote panel, the default monitoring display will be shown: EN Charge current icon Battery status icons Load status icon Day/night. Battery icon Load current icon PV- V & A. Battery-V&A Load-V&A Day and night icons - Night,- day. If the voltage of the solar array is above 1V, the daytime icon is shown. Battery icon The battery icon shows the state of charge of the battery. For this function the correct battery capacity must be set (see section 5.4) and all loads must connected to the load output (i.e. not directly to the battery). Note: When the battery is fully discharged, the icon displayed is. 5

Battery status icons - Normal voltage. - Under voltage, - Over discharge Load status icon - Load output on - load output off 3.3. Buttons Operation is visualized in the schematic diagram below: 4. Monitoring The default monitoring display and monitoring subpages can be accessed with the UP/DOWN and LEFT/RIGHT buttons. See the diagram on the next page. 6

7 EN

5. Full setup details 5.1. Main menu When in monitoring mode, the main menu is accessed by pressing the ESC button. The UP and DOWN buttons are used to browse through the main menu: 1 Monitoring 2 Device information 3 Test operation 4 Control parameters 5 Load set 6 Device parameters 7 Device password 8 Charge mode 9 Factory reset 10 Failure information 11 Meter parameters The OK and ESC buttons are respectively used to enter or exit the corresponding pages of the menu items. A password must be entered to change settings. When on a settings page, press OK to access the password page and fill in the password to enable changing of settings. The default password is 000000 5.2 Device information The charge controller model, ratings and serial number are displayed (press the DOWN button to display the serial number). 5.3 Test Operation When the load output is set on manual control (default setting, see section 5,5), the output can be switched ON or OFF with the orange switch button on the Charge Controller. The low voltage cut-off is also operational. 8

The manual control function is disabled when other load output settings are chosen (see section 5.5). However, when other load output settings have been chosen, the load output can be tested (i.e. switched ON and OFF) after switching back to Manual Control. EN 5.4 Control Parameters The table below shows the list of battery related parameters that can be modified. (press the DOWN or UP button to scroll through the parameters) Parameter Default setting Battery type Gel Sealed (AGM) Flooded User defined Battery capacity (Ah) 200Ah 1~9999 Temperature compensation coefficient -3mV/ C per 2V cell 0~9 Rated voltage (system voltage) Auto 12V/24V Over voltage load disconnect 16.0V 9~17V Charge limit (highest charge voltage including temp. compensation) 15.0V 9~17V Over voltage load reconnect 15.0V 9~17V Equalize charge 14.6V 14.8V 9~17V Boost charge (absorption charge) 14.2V 14.4V 14.6V 9~17V Float charge 13.8V 13.8V 13.8V 9~17V Boost trigger voltage (starts new charge cycle) 13.2V 9~17V Low voltage load reconnect 12.6V 9~17V Under voltage warning reset 12.2V 9~17V Under voltage warning 12.0V 9~17V Low voltage load disconnect 11.1V 9~17V (nominal value at 25 C) Discharge limit (lowest low voltage load disconnect including temp. 10.6V 9~17V compensation) Equalize duration 2 hrs. 2 hrs. 0~3 hrs. Boost/absorption duration 2 hrs. 2 hrs. 2 hrs. 0~3 hrs. Multiply voltages by 2 for a 24V system 9

5.5 Load output setting The load output setting options are shown below: Manual Control Light On/Off Light On+Timer Time Control Manual Control Default:ON Manual Control Light On/Off Light On+Timer Time Control Light On/Off On: 0.5V DeT: 10M Off: 0.4V DeT: 10M Manual Control Light On/Off Light On+Timer Time Control Light On+Timer On: 0.5V DeT: 10M Off: 0.6V DeT: 10M NightTime: 12H:00M Light On+Timer OnTime1 01H:00M OnTime2 01H:00M Manual Control Light On/Off Light On+Timer Time Control Time Control Time1 OnTime H : M : S OffTime H : M : S Time Control Time2 OnTime H : M : S OffTime H : M : S Option 1: Manual Control When the load output is set on Manual Control (default setting), the output can be switched ON or OFF with the orange switch button on the Charge Controller. The low voltage cut-off is also operational. 10

Option 2: Light On/Off This is a simple load output On/Off option, based on the solar input voltage of the Controller (= output voltage of the solar panel). When, at dusk, the input voltage of the Controller becomes lower than the light On voltage (default 0.50V), the load output is switched on. When, at dawn, the input voltage of the Controller becomes higher than the light Off voltage (default 0.40V), the load output is switched off. In order to prevent unwanted switching a confirmation time (DeT) can be set: default 10 minutes, range 0 99 minutes. EN Option 3: Light On+Timer This option allows for a pre-set On-time after dusk and a pre-set Off-time before dawn. The dusk and dawn switching moments and confirmation time are set as under option 2. The remaining parameters are set as follows: NightTime: initial setting of the night duration, the controller will subsequently adjust NightTime to the actual duration of the night. On Time 1: On period after dusk. On Time 2: On period before dawn. 11

Option 4: Time control This option uses the internal clock (see section 5.6) to set one (Time1 only) or two on-time periods. 5.6 Device Parameters The first screen displays the software version and communication ID number of the Charge Controller. The second screen allows setting of the backlight timer, and local date & time (use the DOWN button to go to the second screen). The above data are stored in the Charge Controller. Device Parameter Ver: VX.XX ID : XXX Device Parameter Bklight: 60S Month-Day-Year H : M : S 5.7 Device Password The password is needed to change settings of the charge controller. The default password is 000000. The password is stored in the Charge Controller 5.8 Charge mode This page is intended for future applications. Please do not change. 5.9 Factory reset Allows reset of the charge controller to the default settings. 12

5.10 Failure Information Displays failures such as Over Voltage, Over Load or Short Circuit. (automatic reset when the fault is corrected). EN 5.11 Parameters The first screen displays the type, software version and serial number of the remote meter. The second screen allows modification of Switch-Pages (refresh time interval of the monitoring pages, default 0 seconds) Backlight duration (default 20 seconds). Audible alarm ON/OFF (default OFF). 6 Technical Specifications Self-consumption Faceplate dimensions Frame dimensions Connector type Cable length Weight Ambient Temperature backlight and acoustic alarm on max. 65mA Backlight on max. 23mA Backlight off max. 15mA 98 98 mm / 3.86 3.86 inch 114 114 mm / 4.49 4.49 inch RJ45 Max. 20 m 0.2 Kg -20 C~+70 C / -4 F~158 F 7 RS-485 connector pinout: Pin No. 1 Power: +12V 2 RS485 B 3 RS485 A 4 GND 5 GND 6 RS485 A 7 RS485 B 8 Power: +12V 13

8 Dimensions: 14

Victron Energy Blue Power Distributor: Serial number: Serial number: Version : 02 Date : 01 September 2014 Victron Energy B.V. De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone : +31 (0)36 535 97 00 Customer support desk : +31 (0)36 535 97 03 Fax : +31 (0)36 535 97 40 E-mail : sales@victronenergy.com www.victronenergy.com