water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.



Similar documents
Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Disturbance Recoder SPCR 8C27. Product Guide

HYDRO-ELECTRIC POWER PLANTS

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

Technical Specification Of Substation Protection & Control System with IEC BHEL s Perspective

OZW30. Central Unit SYNERGYR

Permissible ambient temperature Operation Storage, transport

Diesel Engine Driven Generators Page 1 of 6

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

30 ms High Speed Transfer System (HSTS) Product Description

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

Voltage Regulator SPAU 341 C. Product Guide

Power network telecommunication

Workshop 7 PC Software - Tracker

Wind-Diesel Hybrid System Options for Alaska. Steve Drouilhet National Renewable Energy Laboratory Golden, CO

Dual Fuel Medium Speed Product. Presenter Name Date

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Design of electrical power system for a 1000MW nuclear power generating station

Powerformer chosen for Swedish combined heat and power plant

ABB PSPS Erich Steinmann; Generator control-2013

POWER PLANT GAS CONVERSIONS WÄRTSILÄ SPARK IGNITED GAS ENGINE (SG) CONCEPT

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Alain Nifenecker - General Electric Manager Controls Engineering

Marine Generating Sets 3.7 to 50 kva

Basics in Energy Information (& Communication) Systems Substation Automation

Nuclear Power Plant Electrical Power Supply System Requirements

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cahier technique no. 196

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Industrial IT for Substation Automation & Protection

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

The Optical Submarine Repeater and Its Associated Technologies

Up-to-Date with Electrical Equipment

Updating to Test Universe 3.0. What s new?

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Recent Technologies in Nuclear Power Plant Supervisory and Control Systems

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Power Feeding Equipment for Optical Submarine Cable Systems

FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Engine Room Console 6

SPPA-T3000 Control System The Benchmark in Controls

Context: significant penetration of DG = increased risks for system security

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Table of Contents. TransformerIQ FAQs 1

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Waveguide Access Point WGA631. Product Guide

Mechanical Engineering Technician- Plant Technician

Installation manual. Generator Paralleling Controller GPC multi-line C

Efficient servicing. Easy maintenance. High level of uptime.

Diagnostic Fault Codes For Cummins Engines

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Technical Information POWER PLANT CONTROLLER

Combined Cycle Control Overview

PowerCommand 3201 digital generator set control

Generic PCSR Sub-chapter 15.4 : Electrical Equipment

Automation and control

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Configuring PROFINET

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Atlas Copco Generators

Paralleling Switchgear

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Latest Power Plant Control System

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Excitation.

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Green Energy Solutions

Floating. Diesel power stations

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Introduction Media converters

DCM. Product Brochure. Diagnostic Communication Master

Future grid infrastructure Field tests of LVDC distribution

SWITCHGEAR. EGP Switchgear

Basics electronic speed Governor

NC-12 Modbus Application

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Heating Controller. Building Technologies HVAC Products

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

PRODUCTS PRODUCTS ABOUT US.

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

GE Intelligent Platforms. PACSystems High Availability Solutions

Capacitor Protection Relay SPAJ 160 C. Product Guide

Completion of High-efficiency Coal-fired Power Plant

T Substation Maintenance and Commissioning Test Equipment

Integrated Power Systems for Data Centers

Colocation. Introduction. Structure of the service. Service Description

Grid Automation Products. MicroSCADA Pro for substation automation

Automation Unit TM 1703 ACP Flexible automation and telecontrol

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

Synchronization.

vacon ac drives for mining & minerals

Transcription:

for the start-up and shut-down procedures in the case of longer standstills. The diesel exhaust is fed into two turbochargers. A portion of the exhaust gases can be utilized in a waste-heat boiler producing steam for preheating the heavy fuel oil and those units at standby. Silencers lower the exhaust sound to a level below the values stipulated by reek and EU legislation. The system is supplied with fuel from fuel tanks, after being passed through a heavy fuel oil treatment plant with self-cleaning separators and filter systems. The oil sludge produced during the treatment is utilized in the incinerator for heat and steam generation. Scope of supply of Kraftwerke A as specified by the turnkey contract for the Rhodes diesel power plant: Engineering, calculation, delivery, installation, commissioning, and acceptance tests Three 29-MVA generators Three 30-MVA main transformers Three 2.5-MVA auxiliary transformers MV switchgear units Digital DPC system with VDUbased process control, hardware and software, including data transfer to the load dispatcher on the island of Rhodes Central control room equipment Protection, instrumentation and metering equipment Training of the customer s operating and maintenance personnel, including documentation Performance of trial run in accordance with details agreed in the contract Assistance in operating plant during the semi-commercial and commercial operating phase Verification of the specified operating data Rhodes diesel power plant, today with two 12-MW and three 24-MW units 1 The diesel engines and generators are Process control tasks cooled in a primary cooling cycle that The DPC system for the new 24-MW units uses demineralized water. The cooling 3, 4 and 5 has the following main process water is cooled in a secondary cooling control tasks: cycle with heat-exchangers that make Safe and cost-effective start-up and use of seawater. Treatment of the seawater is necessary to prevent the shortest possible times for start-up shut-down of the three units, with the formation of algal vegetation. The operational wastewater from all areas of the conditions on the basis of the power Economical handling of changing load power plant is collected and cleaned in demands made on the local grid the wastewater treatment plant before Automatic control and monitoring of being discharged into the sea. the mechanical equipment, while en- Review 5/1998 29

Table 1: Technical data of units 3, 4 and 5 of the Rhodes diesel power plant Main data Output per unit (MW e ) 23.411 Overall output (MW e ) 70.233 Diesel-generator set Diesel engine SEMT Pielstick Type PC 4.2-B, four-stroke, 18 cylinders, 2 turbochargers Output (MW) 23.85 Synchronous generator Type W 268/125/14 Output (MVA) 29.35 Power factor 0.8 Frequency (Hz) 50 Speed (rev/min) 428.6 Static excitation system Output (kva) 250 Main transformer Output (MVA) 30 Voltage (kv/kv) 10/66 Type of cooling ONAN/ONAF suring the highest possible level of plant reliability and availability Protective measures to guard the plant from inadmissible operating conditions Single-line diagram of the three new 24-MW units 3, 4 and 5 2 10 kv Unit 1 & 2 380 V 66 kv Unit 3 Unit 4 Unit 5 Monitoring and control of power plant operation from the central control room Video display of process data in the control room, facilitating quick intervention by the operating personnel in the event of disturbances; in addition, essential process data is shown on a mosaic display panel and on an operator desk. Process control concept The customer specified high-quality process control features to ensure optimized plant operation. The installed system with its hardware and software components and a user-friendly man-machine communication interface is designed to meet the demands in full. The digital stored-program control system is based on a hierarchical control concept with decentralized units. The data is transmitted over a high-speed data bus (Ethernet IEEE), providing realtime information at any point on the data bus 4. Monitoring and diagnostic functions are automatic, thus ensuring reliable fault detection at operator stations in the central control room for fast clearance of faults. The power plant control and monitoring functions are assigned to three different control levels to ensure reliable and user-friendly operation and maintenance of the plant: Central unit control level Distributed system control level Drive control level The high level of reliability of the DPC system is enhanced further by a redundant MB 300 bus. This bus is based on coaxial and fiber-optic cables providing links to the process computers for the diesel-generator sets as well as to the process computers in the vicinity of the 30 Review 5/1998

general auxiliary systems, such as the sea-water pumping station, heavy fuel oil treatment plant and the general equipment in the machine hall. The data bus also provides interfaces between the computers and the relay room, the recorder and mosaic display panel, the control desk and the information management system. The functionality of the installed process control system provides for operational control and protective functions as well as database-related functions for historical data acquisition and the generation of trends and statistics: Acquisition and sequenced processing of all operating data Monitoring and control of the three generator sets One of the three 24-MW diesel-generator sets 3 Configuration of the Diesel Process Control (DPC) system for units 3, 4 and 5 4 AC Decentralized process computer DAT Historical data storage (tape unit) AS Operator station computer VDU Display unit in operator station Relay room Hardcopy printer Control room To inspect system ( supplied by SEMT ) VDU VDU VDU VDU VDU Recorder panel Mosaic panel / desk Printer Printer AS 515 DAT AC 410 AC 450 MB 300 Events & alarms AS 520 AS 520 Events & alarms Transceiver Fiber optic Coaxial cable AC 450 Active star coupler AC 450 AC 450 AC 450 AC 450 AC 410 AC 450 Seawater pumping station HFO treatment plant Unit 5 Common part Machine hall Unit 4 Common part Machine hall ( Optional ) Unit 3 Review 5/1998 31

Screenshot of the fuel system for the plant 5 Monitoring and control of the general Specification of the setpoints for automatic start-up and shut-down of the and auxiliary systems Monitoring and control of the 66-kV diesel-generator units switchyard Specification of the output and voltage control setpoints for the generators and the overall power plant Time synchronization for the entire process control system Transfer of information to the load dispatcher of the customer Information management system, including operator station, for operational statistics with historical data memory The process variables are controlled and displayed at two operator stations, each with two VDUs. The DPC system processes all of the relevant process data: 4,740 digital inputs (status messages) 1,300 digital outputs (command outputs, signals) 700 analogue inputs (measured values, counter readings) 230 analogue outputs (indicators, recording devices) The system can be easily extended for larger amounts of data. The process control equipment is supplied through an uninterruptible power supply system. Screenshot of the electrical equipment, including the generators 6 Components of the DPC system The distributed process computer stations consist of the following main units: Process computer (AC400) including central processing units and I/O boards Interface for the MasterBus 300 I/O interface between the stations and the process Power supply and distribution Transducers for electrical variables Synchronization equipment The above components are housed in sheet-steel cabinets complying with protection class IP 42. The generator control functions also include control and monitoring of the power output and the speed of the machine. Values can be set for the voltage, speed and load, these being processed and maintained by the regulators 32 Review 5/1998

situated further downstream. The design of the control features allows isochronous load sharing, base loading and droop mode operation. The generator sets are usually started up, shut down and controlled from the central control room. The operator can choose whether the diesel-generator sets are to be operated in manual or automatic mode. Operation of the auxiliary systems is fully automatic; all functions for pressure, level or other control, with either binary or analogue signals, are monitored. Every item of information about the power plant process is transmitted to the highperformance bus in real-time sequence, whereupon it is available to every station connected to the bus. The operator stations include the following features: System monitoring Listing of alarms and events raphic process images in real time Object displays 6 Trend displays and curves Reports Security system for selected operator access to special system data and applications Network communication Clock synchronization via bus/network Windowing capabilities The decentralized system configuration with a central control room gives the operator full access to all the process data and operational processes at all times. The control system philosophy is based on a large number of stand-alone control units, resulting in independent process sections. The plant is operated from the operator stations in the control room as well as from manual controls at the control cabinets or local operating panels for the auxiliary systems or switchgear units. The operator stations are incorporated in the central control desk 7. They 5 Operator station in the central control room 7 comply with the standards applicable for industrial use and feature all the ergonomic qualities found in modern control room design. semi-commercial and commercial operating phase. The specified operating data were verified in pre-defined performance test procedures that were conducted in mid-1998 in cooperation with independent experts appointed by the customer. Operating experience The three new power plant units and the DPC system have been on-line since late 1997. The experience gained during commissioning and the first phase of operation shows that the new control technology meets the high expectations for the project in full. The 8-day and 10-day load operations Author Paul Haag Kraftwerke A P.O. box 100 351 D-68128 Mannheim which were contractually specified ermany showed that the overall plant is able to maintain its reliability standards during the Telefax: +49 621 381 8188 E-mail: paul.haag@dekwe.mail.abb.com Review 5/1998 33