The Optical Submarine Repeater and Its Associated Technologies
|
|
|
- Ellen McBride
- 9 years ago
- Views:
Transcription
1 The Optical Submarine Repeater and Its Associated Technologies YAMAGUCHI Shohei, MIKAMI Satoshi, AIDA Ryuji, NAGASAWA Toshihide Abstract The key to meeting the increasing needs of submarine cable systems (increase in capacity, increase in distance, multipoint connections, etc.) is how to incorporate and implement designs for optical submarine repeaters, gain equalizers and the branching units installed in the submarine sections. This paper introduces the functions of different types of equipment and the technologies applied to them. Keywords optical submarine repeater, gain equalization, branching unit, EDFA, Remote control, OADM 1. Introduction Following the introduction of new services such as data communication and video distribution via the Internet, the demand for international communications has been expanding rapidly. In order to meet these market demands, technologies for increasing the capacity of long-distance optical signal transmission systems are being further researched and developed, and optical submarine cable systems for applying the latest technologies are being planned and laid one after another. This paper describes the performances and technologies of the submarine equipment, such as the optical submarine repeaters, gain equalizers and branching units. 2. Optical Submarine Repeater to withstand the pressure of 8,000m water depth. The highperformance sealing technology is based on our long years of experience in the field of submarine repeaters for coaxial systems. 4) All-optical monitoring: In order to implement a high Photo Table External view of an optical submarine repeater. Specifications of the optical submarine repeater. As it is laid on the sea bed, the optical submarine repeater should be a maintenance-free. It is designed therefore to achieve high reliability by applying the following technologies. Photo and Table show an external view and the main specifications, respectively. 1) Direct optical amplification: This repeater employs optical amplifiers using erbium-doped fibers (EDF) and 980 nm pump laser diodes (LDs). The pump LDs are provided in a redundant configuration in order to realize high reliability. 2) High reliability: The optical submarine repeater achieves high reliability by applying advanced LSI technology and high-reliability components. 3) High resistance to water pressure and high performance sealing: The housing of the submarine repeater is designed NEC TECHNICAL JOURNAL Vol.5 No.1/
2 The Optical Submarine Repeater and Its Associated Technologies reliability monitoring system, an all-optical monitoring system is adopted because this does not require electrical circuitry inside the submarine repeater. Fig. 1 shows the function block diagram of the system unit, which is composed of two optical amplifiers for amplifying signals in both directions. Optical amplifiers with high power outputs of more than +15 dbm and low noise figures of less than 4.7 db are implemented by the forward pumping scheme with high-power 980 nm pump LDs. The transmission bandwidth is realized as large as up to 40 nm thanks to optimization of the EDF lengths and the use of individual gain flattening filters (GFF). Two pump LDs are provided in redundancy and their outputs are multiplexed/ divided using an optical coupler and are injected into the EDFs of both directions. Each pump LD is controlled so that the LD output is constant. In addition, the system is designed so that the transmission path characteristics can be maintained even if one of the two pump LDs fails. The operating status of the optical submarine repeater is monitored using the supervisory signal with the dedicated wavelength of all the wavelengths transmitted from the terminal equipment only the supervisory signal wavelength (λsv) is looped back to the opposite direction fiber by the wavelength selective reflector (WSR) in the optical supervisory circuit of the repeater, as shown in Fig. 1. The looped-back supervisory signal wavelength is received by the terminal equipment, which then analyzes the gain of each repeater section from the level of the supervisory signal wavelength and detects faults such as any loss increases in the submarine cable or a failure of an optical submarine repeater. 3. Gain Equalizer Unit The gain equalizer units are laid at intervals of several repeater sections in order to realize the wide transmission bandwidth of the submarine cable system's many cascaded repeaters. There are two equalization types. One is the gain shape equalizer (SEQ) that compensates for the gain wavelength characteristics of optical submarine repeaters and cables. The other one is the tilt equalizer (TEQ) that compensates for the gain tilt due to variance in repeater output levels and cable loss. The details of the gain equalization technology are described in section 4.1 of Construction Technology for Use in Repeatered Transoceanic Optical Submarine Cable Systems. Fig. 2 shows the block diagram of a gain equalizer unit. The TEQ has several kinds of modules in order to compensate the gain tilt errors that are anticipated for the system due to the performances of the optical submarine repeaters and cables. 4. Branching Unit Branching units realize the systems that connect three or Fig. 1 Function block diagram of system unit. Fig. 2 Block diagram of gain equalizer unit. 14
3 Special Issue on Optical Submarine Cable System Fig. 4 Configuration of remote-controlled BU. (one example) more landing stations. Fig. 3 Power feed path switching. 4.1 Power Feed Path Design With regard to the power feed path design, there are two types of the branching unit (BU), the fixed power feed path type (hereafter, Fixed type) and the power feed path switching type (hereafter, SW type). The SW type electrical circuitry uses a vacuum relay with a high withstanding voltage for the path switching. The vacuum relay is switched either by controlling the feed current of the submarine cable system or by remote control using a command signal from the terminal equipment. The SW type BU has the function of re-making the system power configuration if a submarine cable fault should occur. Fig. 3 shows the settings of the SW type BU. This unit is capable of the following four connection status settings. (a) Non power feed status. (b) Initial status: (+) feed for trunk A (-) feed for trunk B and (-) feed for branch C Sea earth (GND). (c) Trunk B fault status: (+) feed for trunk A (-) feed for branch C. (d) Trunk A fault status: (+9 feed for trunk B (-) feed for branch C. After the submarine cable has been laid, the non power feed status can be used to confirm absence of faults such as grounding in the cable by interconnecting A, B and C in the submarine branching unit while isolating them from the sea earth (GND). In the initial operation status, the power feed path is configured with a both-ends power feed between trunks A-B and connecting the branch C to the sea earth (GND). If a fault occurs in trunk A or B, the BU reconfigures the power feed path to ensure trunk power feed by enabling power feed between trunk B and branch C or between trunk A and branch C. At the outset, the vacuum relay used for power feed path switching was controlled with the feed current. However, with a system connecting four or more stations, control is very difficult and power feed switching may become impossible depending on the mode of the fault. Therefore, a remote control method for setting the vacuum relay using a signal from the terminal station is being developed. While the vacuum relay switched by the feed current control is a non-holding relay as described above, that relayed by remote control also uses a holding relay. This arrangement holds the power feed circuit status even in the case of a fault, thus maintaining communications if a fault occurs and enabling repair after the fault is located. Fig. 4 shows an example of the configuration of a remotely controlled type BU. The control signal used to transmit information from the terminal station is obtained by superimposing the control signal carrier onto the optical signal by means of ASK or FSK modulation. The vacuum relay of the BU specified in the control signal can be switched as desired. In the example of Fig. 4, the optical signal in which the control signal is superimposed is a signal with a dedicated wavelength. In consideration of a case of cable fault, it is required to provide one or more control paths from both the trunk and branch stations. NEC TECHNICAL JOURNAL Vol.5 No.1/
4 The Optical Submarine Repeater and Its Associated Technologies Fig. 6 Structure of pressure housing. Fig. 5 Configuration of OADM BU system (one example). 4.2 Transmission System Design Regarding the transmission path design, there are two types of BU, the fiber branching type that branches signals on a perfiber basis and the OADM (Optical Add Drop Multiplexer) type that branches signals on a per-wavelength basis. The OADM type BU is capable of flexible wavelength multiplexing/demultiplexing by using optical filters in accordance with the system requirements. Fig. 5 shows an example of system configuration applying OADM type BU. Here, the transmission wavelengths are divided into some sub-bands and each sub-band is allocated for the communication between each station. In Fig. 5, Fiber pair 1 (FP1) provides full-band connection between stations A and D while fiber pair 2 (FP2) applies the OADM function for connections between the branch and trunk stations and those between the branch stations. This configuration makes it possible to implement a submarine cable system as a mesh network instead of the current ring network. 5. Mechanical Design of Submarine Equipment The submarine equipment is composed of the pressure resistant housing and the internal unit mounted inside the housing. (1)Internal Unit The most important consideration in the submarine equipment mechanical design is the heat dissipation characteristics. The thermal contact resistance between the electrical circuitry and the pressure housing is minimized in order to obtain optimum heat dissipation. Therefore, the high power parts such as the pumping LDs in the optical submarine repeater are mounted directly in the metallic cases of the subunit. In consideration of the thermal resistance and the alleviation of external impacts, the internal unit is fixed using rubber cushions and metallic springs inside the pressure resistant housing. (2)Pressure-Resistant Housing Fig. 6 shows a pressure-resistant housing design based on the coaxial submarine repeater technology. The housing is composed of the following main parts; 1) The cylinder and the two cover assemblies; 2) The two joint rings connecting the cylinder to the cable. The main material of the pressure-resistant housing is the beryllium-copper alloy that features a high tensile strength and excellent corrosion resistance characteristics. The pressure resistant housing is sealed in order to effectively protect the submarine repeater unit against penetration of water and gases from the seawater. This sealing design is achieved using the following technologies; 1) Sealing of cylinder and covers by means of electron beam welding; 2) Sealing of optical fibers (feed-through) by soldering. The solder used to seal the fibers remains stable for a long period and is capable of maintaining the relative humidity inside the pressure-resistant housing at below 20% for 25 years. The feed-through sealing can prevent penetration of water and gases effectively, even if a cable near to the submarine equipment is cut. In order to ensure airtightness and water pressure resistance, the pressure resistant housing is tested using helium gas at an equivalent pressure to the maximum depth of the submarine system. Impacts and vibrations during the transportation and placing of the equipment on the seabed are buffered by the rubber cushions and metallic springs placed between the optical submarine repeater housing and the submarine repeater unit. 16
5 Special Issue on Optical Submarine Cable System The optical submarine repeater and cable couplings are connected using a clamping ring at the end of the joint ring. The pressure-resistant structure of the submarine branching unit is designed based on the basic design of the repeater as described above. However, the pressure resistant housing of the branching unit is in general larger than that used with the optical submarine repeater. This is because, in order to perform power feed switching, a higher withstanding voltage than the optical submarine repeater is required inside the housing and two couplings need to be attached on the branching side. 6. Conclusion NEC has provided more than 3,000 sets of equipment for the market and up to the present time none of these has failed. We intend to continue to offer our high-reliability, high-performance designs in the future, and as the acknowledged leading company in the industry, we will continue to provide an unrivalled performance in the construction of international and domestic submarine networks. Authors' Profiles YAMAGUCHI Shohei Manager MIKAMI Satoshi Manager AIDA Ryuji Assistant Manager NAGASAWA Toshihide Assistant Manager 1st Mechanical Designs Development Department Technology Development Division NEC Engineering, Ltd. NEC TECHNICAL JOURNAL Vol.5 No.1/
Power Feeding Equipment for Optical Submarine Cable Systems
Power Feeding Equipment for Optical Submarine Cable Systems KANEKO Tomoyuki, CHIBA Yoshinori, KUNIMI Kaneaki, NAKAMURA Tomotaka Abstract A submarine cable system is fed power from power feeding equipment
Optical Submarine Cable Network Monitoring Equipment
Optical Submarine Cable Network Monitoring Equipment NOMURA Kenichi, TAKEDA Takaaki Abstract The introduction of large-capacity wavelength-division multiplexing and OADM (Optical Add/Drop Multiplexing)
Line Monitoring and Control in Subsea Networks
Line Monitoring and Control in Subsea Networks This paper discusses how submerged equipment is monitored and contrasts different methods of doing this. It also considers what features are required by the
Large-Capacity Optical Transmission Technologies Supporting the Optical Submarine Cable System
Large-Capacity Optical Transmission Technologies Supporting the Optical Submarine Cable System INOUE Takanori Abstract As one of the foundations of the global network, the submarine cable system is required
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.
High-Performance Submarine Line Terminal Equipment for Next-Generation Optical Submarine Cable System: FLASHWAVE S650
High-Performance Submarine Line Terminal Equipment for Next-Generation Optical Submarine Cable System: V Hiroshi Oikawa V Junichi Yoshimura V Haruki Watanabe (Manuscript received June 20, 2006) Global
Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur
Module 5 Broadcast Communication Networks Lesson 1 Network Topology Specific Instructional Objectives At the end of this lesson, the students will be able to: Specify what is meant by network topology
Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B
CSE 3461 / 5461: Computer Networking & Internet Technologies Data Transmission Presentation B Kannan Srinivasan 08/30/2012 Data Communications Model Figure 1.2 Studying Assignment: 3.1-3.4, 4.1 Presentation
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Table of Contents. Cableoptics Nodes Broadband Telecommunications Multi-Optic Node [BTN-M-75SH/*] FEATURES
Table of Contents Cableoptics Nodes Broadband Telecommunications Multi-Optic Node [-75SH/*] FEATURES 52 to 750 MHz forward, 5 to 40 MHz return (Other splits available see specs) A/B switching for optical
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
On Cables and Connections A discussion by Dr. J. Kramer
KRAMER ELECTRONICS LTD. On Cables and Connections A discussion by Dr. J. Kramer We are frequently asked - "what length of cable can I use for a specific application?" Seemingly a simple question, but the
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
E-Option Multi-taps Conditioning at the Tap
E-Option Multi-taps Conditioning at the Tap (actual size) Introduction Traditional Cable Television Systems had long been associated with one-way downstream signal transmissions that provide video services
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
Power over Ethernet technology for industrial Ethernet networks
Power over Ethernet technology for industrial Ethernet networks Introduction Ethernet networking has grown beyond office and home usage to become a very successful protocol suite used in many industrial
40-Gb/s Dense Wavelength Division Multiplexing Transmission System
40-Gb/s Dense Wavelength Division Multiplexing Transmission System Kazuo Wani Takeshi Ono (Manuscript received March 25, 2009) Fujitsu Telecom Networks develops supplies optical transmission systems for
Modeling and Performance Analysis of DWDM Based 100 Gbps Low Power Inter-satellite Optical Wireless Communication (LP-IsOWC) System
ISSN(Print): 2377-0538 ISSN(Online): 2377-0546 DOI: 10.15764/STSP.2015.01001 Volume 2, Number 1, January 2015 SOP TRANSACTIONS ON SIGNAL PROCESSING Modeling and Performance Analysis of DWDM Based 100 Gbps
Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help
Future Stars Grade X Manual Chapter 1 Networking and Telecommunication 1. Answer the following questions. a. What is telecommunication? Ans: The transfer of information at a far distance is known as telecommunication.
HDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
Computers Are Your Future. 2006 Prentice-Hall, Inc.
Computers Are Your Future 2006 Prentice-Hall, Inc. Computers Are Your Future Chapter 3 Wired and Wireless Communication 2006 Prentice-Hall, Inc Slide 2 What You Will Learn... ü The definition of bandwidth
The Operation and Power Budget of Amplified Optical Networks for Aerospace Applications. FOHEC Conference May 2010
The Operation and Power Budget of Amplified Optical Networks for Aerospace Applications FOHEC Conference May 2010 BAE Systems / University of Strathclyde Henry White Walter Johnstone Craig Michie BAE Systems
New Technologies for Electric Power Distribution Systems
New Technologies for Electric Power Distribution Systems 158 New Technologies for Electric Power Distribution Systems to Unify Protection/ Units so They Can Be Incorporated into Intelligent Substations
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Single Channel Loop Detector
Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop
Practical Application of Industrial Fiber Optic Sensing Systems
Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,
Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.
Multiplexing Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium. The following two factors in data communications lead to
3-5 Ka-band High Power Multi-port Amplifier (MPA)
3-5 Ka-band High Power Multi-port Amplifier (MPA) KURODA Tomonori, SHIMADA Masaaki, OGAWA Yasuo, HOSODA Ikuo, KATAKAMI Kanji, MOTOHASHI Yasuo, NAKAZAWA Minoru, and KITAHARA Masaki Ka-band High Power Multi-port
USER MANUAL FIBER OPTIC ANALOG TRANSMITTER AND RECEIVER MODULE
USER MANUAL FIBER OPTIC ANALOG TRANSMITTER AND RECEIVER MODULE Table of Contents 1. INTRODUCTION... 3 2. PREFACE... 4 2.1 Transmitter... 4 2.2 Optical fiber... 4 2.3 Receiver... 5 2.4 Advantage of Optical
ILX Lightwave Corporation www.ilxlightwave.com
# 14 Optimizing TEC Current Optimizing TEC Drive Current This Application Note discusses methods for optimizing the TEC drive current for optimum operation in heating and cooling applications. BACKGROUND
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
A Simple Fiber Bragg Grating-Based Sensor Network Architecture with Self-Protecting and Monitoring Functions
Sensors 2011, 11, 1375-1382; doi:10.3390/s110201375 OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article A Simple Fiber Bragg Grating-Based Sensor Network Architecture with Self-Protecting
Optical Amplifiers. Ericsson
Optical Amplifiers Ericsson Introduction In any link, optical power pumped and the receiver sensitivity is limited and can only support for a limited distance To over come the losses in the network, either
IEO 5701 Optical Fiber Communication. 2015 Lecture 1
IEO 5701 Optical Fiber Communication 2015 Lecture 1 Course Outline Lecturer : Prof. CHOW Chi Wai ( 鄒 志 偉 ) Email : [email protected] TA: Mr. C. W. Hsu ( 許 勁 崴 ) Email : [email protected] Course
Optical Communication Networks. Transport networks
Optical Communication Networks Transport networks Corso di Laurea Specialistica in Ingegneria delle Telecomunicazioni A.A. 2009/2010 Transport networks (1) Transport networks Evolution of TLC networks
THE STRAIN GAGE PRESSURE TRANSDUCER
THE STRAIN GAGE PRESSURE TRANSDUCER Pressure transducers use a variety of sensing devices to provide an electrical output proportional to applied pressure. The sensing device employed in the transducers
Designing Fiber Optic Systems David Strachan
Designing Fiber Optic Systems David Strachan Everyone knows that fiber optics can carry a huge amount of data. There are more benefits to using fiber optics in broadcast applications than you might realize.
Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ
* Teleprotection Schemes and Equipment James W. Ebrecht Young Power Equipment Scottsdale, AZ Teleprotection Schemes And Equipment ~ ~ Relay Relay Teleprotection Communications channel Teleprotection Protection
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing
High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing Y u a n L i a n d R o b e r t A. M i n a s i a n School of Electrical and Information Engineering and APCRC University
NMEA 0183 INSTALLATION AND OPERATING GUIDELINES
NMEA 0183 INSTALLATION AND OPERATING GUIDELINES Revised July 2010 8.1.3 Documentation The following documentation shall be provided to the owner for each interfaced system and shall be kept on file by
water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.
for the start-up and shut-down procedures in the case of longer standstills. The diesel exhaust is fed into two turbochargers. A portion of the exhaust gases can be utilized in a waste-heat boiler producing
Ultra High-Speed SONET Fiber-Optic Transmission System
Ultra High-Speed Fiber-Optic Transmission System Takashi Mori Hirokuni Tsuji Hiroyuki Nakano, D.E. Shigeo Shinada ABSTRACT: Recently, there have been numerous demands not only on voice but also data/image
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Chapter 8: The Telephone System
Chapter 8: The Telephone System MULTIPLE CHOICE 1. DTMF stands for: a. Digital Telephony Multiple Frequency c. Dual-Tone Multifrequency b. Dial Tone Master Frequency d. Digital Trunk Master Frequency 2.
The 50G Silicon Photonics Link
The 50G Silicon Photonics Link The world s first silicon-based optical data connection with integrated lasers White Paper Intel Labs July 2010 Executive Summary As information technology continues to advance,
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Cable Network Transparency Fiber Optic Monitoring
Cable Network Transparency Fiber Optic Monitoring Fault recognition, localisation and reporting Fiber Optic Cable Future of Telecommunication The demand for complex fiber optic cable networks and flexible
How To Define Hfc Technology
Cable network topologies and implications for evolutionary approaches 33 rd International conference and Exhibition PIKE 2008, Zakopane, 14 October 2008 Bart Brusse, ReDeSign Project Manager Pressure on
INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA
COMM.ENG INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA 9/6/2014 LECTURES 1 Objectives To give a background on Communication system components and channels (media) A distinction between analogue
Fiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
Laser-Optimized Fiber
FIBER FAQs Laser-Optimized Fiber Technical Resource: Tony Irujo Manager, Customer Technical Support FIBER FAQs Laser-Optimized Fiber As transmission speeds over optical fiber networks in the enterprise
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
Simulation and Best Design of an Optical Single Channel in Optical Communication Network
International Arab Journal of e-technology, Vol., No., June 11 91 Simulation and Best Design of an Optical Single Channel in Optical Communication Network Salah Alabady Computer Engineering Department,
Introduction to Optical Networks
Yatindra Nath Singh Assistant Professor Electrical Engineering Department Indian Institute of Technology, Kanpur Email: [email protected] http://home.iitk.ac.in/~ynsingh 1 What are optical network? Telecomm
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
GaAs Switch ICs for Cellular Phone Antenna Impedance Matching
GaAs Switch ICs for Cellular Phone Antenna Impedance Matching IWATA Naotaka, FUJITA Masanori Abstract Recently cellular phones have been advancing toward multi-band and multi-mode phones and many of them
Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System
Utilizing Furukawa Optical Fiber Technology Optical Fiber Sensing Point Special features of optical fiber sensing s 1Reduced installation cost Sensors (measurement location) require no electrical work
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
Solution 1: Algorithm Positioning
Model No: OEAFP Series All-Fiber Pipeline Security System Solutions Solution 1: Algorithm Positioning Application conditions Applicable for outdoor long-distance oil-gas pipeline security monitoring without
Value Proposition for Data Centers
Value Proposition for Data Centers C ollocation or a trend of hosting customers servers at a provider s physical location has been steadily growing in the recent years due to its many benefits. The collocation
Network Structure or Topology
Volume 1, Issue 2, July 2013 International Journal of Advance Research in Computer Science and Management Studies Research Paper Available online at: www.ijarcsms.com Network Structure or Topology Kartik
Power network telecommunication
www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,
Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere
Application TETRA / TETRAPOL coverage enhancement Safety networks Railway, road and waterway tunnels The manufacturer retains the right to modify its products This document is not contractual. AIR Repeater
Grounding of Electrical Systems NEW CODE: Grounding and Bonding
Grounding of Electrical Systems NEW CODE: Grounding and Bonding Presented By Scott Peele PE Grounding of Electrical Systems Outline Defining the Terms Why should I Ground? Types of Grounding Systems Separately
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
How To Encode Data From A Signal To A Signal (Wired) To A Bitcode (Wired Or Coaxial)
Physical Layer Part 2 Data Encoding Techniques Networks: Data Encoding 1 Analog and Digital Transmissions Figure 2-23.The use of both analog and digital transmissions for a computer to computer call. Conversion
TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS 190-535 khz
TOTALLY SOLID STATE NON-DIRECTIONAL RADIO S 190-535 khz This family of radio transmitters has been developed as extremely efficient, highly reliable Non Directional Beacons. ND2000A/4000A» MODULAR CONSTRUCTION»
Disaster Recovery Design Ehab Ashary University of Colorado at Colorado Springs
Disaster Recovery Design Ehab Ashary University of Colorado at Colorado Springs As a head of the campus network department in the Deanship of Information Technology at King Abdulaziz University for more
Signal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam
Transmission Media Transmission medium Physical path between transmitter and receiver May be guided (wired) or unguided (wireless) Communication achieved by using em waves Characteristics and quality of
Features, Benefits, and Operation
Features, Benefits, and Operation 2014 Decibel Eleven Contents Introduction... 2 Features... 2 Rear Panel... 3 Connections... 3 Power... 3 MIDI... 3 Pedal Loops... 4 Example Connection Diagrams... 5,6
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
Programming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
Create. Monitor. Reconfigure. Switching RF Over Fiber. Case Study. The Problem. www.glimmerglass.com
Switching RF Over Fiber Case Study US Agency Create Monitor The benefits of using fiber for data transmissions are significant and undisputed. However, RF engineers have believed that fiber optics delivers
SATELLITE MASTER ANTENNA TELEVISION SYSTEM
SATELLITE MASTER ANTENNA TELEVISION SYSTEM The Contractor shall supply, install, test, commission, guarantee and maintain a Modern Satellite Master Antenna Television (SMATV) system for the distribution
Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V
Fiber Optics Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 Features Bipolar IC with open-collector output Digital output, TTL compatible Sensitive in visible
Telecommunications Technology
Unit 12: Telecommunications Technology Unit code: K/601/3290 QCF Level 2: BTEC Specialist Credit value: 10 Guided learning hours: 60 Aim and purpose To enable learners to know how telecommunication systems
Application Note Noise Frequently Asked Questions
: What is? is a random signal inherent in all physical components. It directly limits the detection and processing of all information. The common form of noise is white Gaussian due to the many random
1550 Video Overlay for FTTH
1550 Video Overlay for FTTH The New Old Reliable Fernando Villarruel Leonard Ray John McKeon Service Provider Video Technology Group 1 Presentation Overview Background of Overlay in PON Deployment Architecture
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
In This Issue: System Upgrades Edition
Voice of the Industry 73 n o v 2013 ISSN 1948-3031 System Upgrades Edition In This Issue: The Road to Upgrades Upgrading Cables Systems: An Opportunity to Turn Point-to-Point Links into More Global Networks
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement
A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement Trilochan patra Assistant professor, Department of Electronics and Communication Engineering, Techno India
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3
Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic
How to Determine the Right Fiber Optic Network Backup Switch For Your Application
How to Determine the Right Fiber Optic Network Backup Switch For Your Application Raymond B. Sepe, Sr. Electro Standards Laboratories 36 Western Industrial Drive Cranston, RI 02921 Telephone: 1-401-943-1164
Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper
Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
ELEMENTS OF CABLE TELEVISION
1 ELEMENTS OF CABLE TELEVISION Introduction Cable television, from its inception, developed in western countries into two separate systems called Master Antenna Television (MATV) and Community Cable Television
Introduction to Add-Drop Multiplexers
3 Introduction to Add-Drop Multiplexers In this chapter different channel routing technologies are reviewed, highlighting the advantages and drawbacks of the different devices and configurations. The parameters
ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution
Product Information Version 1.0 ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution ZEISS Axiocam 506 color Sensor Model Sensor Pixel
Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers
HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers Data Sheet SERCOS SERCOS is a SErial Realtime COmmunication System, a standard digital interface for communication between controls and drives
Media Conversion in Video Security and Surveillance Systems
The Conversion Technology Experts Media Conversion in Video Security and Surveillance Systems Worldwide Headquarters 6475 City West Parkway Eden Prairie, MN 55344 USA tel 952.941.7600 toll free 800.526.9267
