Section 04810 EXTERIOR STONE VENEER Full Mortar



Similar documents
Manufactured Stone and Thin Brick Installation Systems

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

LATICRETE 290 Premium Floor and Wall Thin-set Adhesive PRODUCT DESCRIPTION

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Manufactured Stone Veneer Installation Instructions

SECTION STONE MASONRY VENEER New England Thinstones

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

GigaCrete Specification PlasterMax

SECTION RESURFACING CAST IN PLACE CONCRETE

Natural Thin Stone Veneer

Shower Walls and Tub Surrounds

Section Polished Concrete Finishing. Vexcon

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Ultracolor CG2. Fast setting and drying grout for 2 to 20 mm joints, available in 26 colours; does not produce efflorescence

Sun Windows General Information Sun New Construction Window Installation Instructions

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

SECTION POLISHED CONCRETE FINISHING

CENTURION STONE SPECIFICATIONS

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

Division 9. SignaFlor Pad and Pour Flooring System

Vanishing Lid Trays Construction Methods with Tile or Masonry

Thin Veneer Stone Installation Guide

How to Install GoBoard:

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

GUIDELINES FOR POLISHED CONCRETE FLOORS A Guide for Integrally Colored, Dyed and Stained Polished Floors

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

GUIDELINE SPECIFICATIONS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

K2 STONE NATURAL VENEER

Division 4 Section Concrete Masonry Specifications

MeltonStone Cast Stone Product Specifications

LAYING BLOCK AND BRICK

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

FIRESTOPPING & SMOKE SEALS

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

application instructions

SECTION STANDING SEAM METAL ROOFING

SECTION EXPANSION CONTROL

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

SECTION PREFORMED METAL STANDING SEAM ROOFING

Architectural Concrete Masonry

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

Resurfacing Concrete. Page 1 of 5

Retail Price List 2015

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

WATERPROOFING OF WET ROOMS

A. Work on this project shall consist of, but is not limited to, the following:

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION Formatted Specification for the ULTRAFLOR DIAMATIC Topical Polished Concrete System DRAFT

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

Stucco and Windows on Wood Frame Construction. Maintaining the Water-shedding Barrier

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Free-Form Concrete Pool

12.1 Schlüter -KERDI-BOARD

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

PART 1 GENERAL 1.1 SECTION INCLUDES

FLOOR TREATMENT 09610

Minor Cracks in Horizontal Surfaces

T R A N S F E R A B L E F U L LY

SEE HOW TO MAKE LIME PLASTER WHY USE LIME? PATTI STOUTER, BUILD SIMPLE INC. FEBRUARY 2013

SECTION STANDING SEAM METAL ROOF

How To Replace A Roofing System In Florida

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Preformed Metal Roofing and Siding

Concrete Repair. Applications and Procedures

SECTION METAL ROOF & WALL PANELS

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

These recommendations generally follow the Construction Specifications Institute (CSI) Master Format.

Mold Preventing I nterior System

HYDRO BAN Sheet Membrane

STUCCOMAX Installation Specifications Exterior One-Coat Stucco over EPS Foam, PU Foams, Exterior Gypsum Board, MgO Board and Cement Block

Cement Board Construction

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

GYPSUM BOARD AND PLASTER

Cement Board Exterior Applications Guide

Metropolitan Builders Association Masonry & Concrete Standard

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

CGA Standard Practices Series. Article 600 Standard for Pozzolan Enhanced Grouts Used in Annular Seals & Well Destruction

Product Guide Specification

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Example Specification for Concrete using Current Building Code Requirements

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

INSTITUTIONAL BARRIER FREE SHOWER INSTALLATION

Waterproof Rooftop Balconies & Decks. Or How To Keep Your Ceiling Dry When People Walk On Your Roof

Transcription:

Full Mortar PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Portland cement mortar bed 2. Stone Veneer 3. Expansion and control joints. 4. Portland cement and hydraulic mortar and grout. 5. Sealer and concentrated cleaner. B. Related work: 1. Section 05410 Load-Bearing Metal Studs. a. 16 gauge or heavier for Stone application. b. Maximum spacing 16 o.c. 2. Section 07900 Joint Sealants C. Related Documents: General and Supplementary Conditions of the Contract, Division 1 General Requirements, and Drawings are applicable to this Section. 1.2 QUALITY ASSURANCE A. Reference specifications and standards: Comply with manufacturer s recommendations and the following unless otherwise specified in this Section. In case of conflict, comply with the most stringent. 1. ANSI A108.1B Tile installed on a cured Portland cement mortar bed. 2. ANSI A108.5 Tile Installed with Dry-Set Portland Cement Mortar or Latex-Portland Cement Mortar 3. ANSI A108.10 Installation of grout in Tile work 4. ANSI A118.4 Latex-Portland Cement Mortar 5. ANSI A118.6 Tile Grout B. Quality Assurance: 1. The work hereunder shall be performed by a single entity with unit responsibility for field measurements, submittals, field installation and warranty. 2. Installer s Qualifications: A firm with not less than five- (5) years experience in the specified unit responsibility and proving a background of not less than three- (3) installations of comparable size and scope to that herein specified. 3. Provide grout and setting materials from one source. Additives, dry-set and latex mortars, installation materials and grouts shall be from the same manufacturer. 4. Furnish a Fifteen-15 year system warranty from a single installation material manufacturer. C. Allowable Tolerances: Polished or Smooth Finishes 1. Except for allowable tolerances in Stone Veneer as specified, make corners of all Stone Veneer flush and level with corners of adjacent Stone Veneer. 2. For flat surfaces, the maximum deviation from true plan, 1/8 in 8 as measured under straight edge placed at any location on surface.

1.3 SUBMITTALS A. Samples: 1. Submit samples of grout and expansion joint material for color approval. 2. Submit samples of each size and type of Stone Veneer showing range of color, shading, and texture. B. Product Data: Submit manufacturer s technical data and MSDS sheets for: 1. Latex Portland cement mortar 2. Polymer-modified cementitious grout 3. Penetrating sealer / Cleaners C. Mock-up: 1. Install a full size mock-up at the job site and secure Architect s review prior to proceeding with installation. 2. Mock-up shall indicate proposed quality of workmanship and include all associated material applications, waterproof membrane, latex Portland cement mortar, grout, sealant, penetrating sealer, etc. 3. Mock-up shall display the full range of color, markings, texture and thickness in materials and shall consist of not less than 4 x 4 of wall Stone Veneer, installed as a single unit representative of the proposed finish condition. 4. Maintain mock-up for reference. D. Substitutions 1. For alternate materials, submit independent laboratory test results confirming compliance with specifications listed in Part 2 - Products at least thirty; (30) days before bid date. 1.4 DELIVERIES, STORAGE AND HANDLING: A. Deliver and store packaged materials in original containers with seals unbroken and labels intact until time of use. Prevent damage or contamination to materials by water, freezing, foreign matter or other causes. B. If frozen, do not stir until material has completely thawed. C. Deliver and store materials on site at least 24 hours before work begins. D. Provide heated and dry storage facilities on site. Maintain temperatures at not less than 50 degrees in Stone Veneer d areas during installation, and for seven- (7) days after completion unless higher temperatures are required by manufacturer s E. Store Stone Veneer cleaning and sealing products tightly capped, upright in the original container. 1.5 PROJECT CONDITIONS: A. Maintain environmental conditions and protect work during and after installation to comply with referenced standards and manufacturer s printed recommendations. B. Provide heated and dry storage facilities on site. Comply with minimum temperature and ventilation recommendations of manufacturer for setting and grouting materials used. See 1.04, D above. C. Protection: Protect adjoining work surfaces during Stone Veneer work. - 2

PART 2- PRODUCTS 2.1 GENERAL A. Comply with the requirements of applicable referenced standards and manufacturer s printed 2.2 STONE VENEER A. Size B. Texture C. Supplied by: NaturalStoneVeneer.Com 2.3 MORTAR ADDITIVE A. Acrylic latex admixture for render and plaster mortar. B. MAPEI Planicrete AC. C. Supplied By: Daltile 2.4 SETTING MATERIALS A. General Requirements: Comply with the requirements of the specifications, applicable reference standards and manufacturer s printed Substitutions are not recommended, as they will void applicable system warranty. B. Manufacturer: MAPEI Corporation, Supplied by Daltile C. Mortar Bond Coat, meeting ANSI A118.4: 1. MAPEI Keralastic/Kerabond System consisting of highly flexible liquid latex mixed with a premium white thin set mortar. 2.4 GROUTING MATERIALS A. Polymer-modified Cementitious Grout meeting ANSI A118.7. 1. MAPEI Ultra/Color Fast Setting, Efflorescence Free, High Compressive Strength Polymer- Modified Sanded Grout and containing a factory blended antimicrobial. Color to be selected by architect. 2.5 ACCESSORIES A. Penetrating Sealers & Cleaners as per the recommendations of the Stone Veneer supplier. B. Water: Clean, potable and fresh. 2.6 MIXES A. Mix waterproof membrane according to manufacturer s printed B. Proportion and mix factory-prepared mortar and grout in accordance with manufacturer s printed - 3

PART 3-EXECUTION 3.1 GENERAL A. Comply with the requirements of the referenced standards. Comply with applicable parts of ANSI A108 for Stone Veneer installation. 3.2 EXAMINATION A. Examine surfaces to receive Stone Veneer work and conditions under which Stone Veneer will be installed. Do not proceed with Stone Veneer work until surfaces and conditions comply with requirements indicated in referenced Stone Veneer installation standard and manufacturer s printed 3.3 SURFACE PREPARATION A. Stud spacing is a maximum of 16 O.C. B. Maximum variation is ¼ in 10 from the required plane. 3.4 INSTALLATION A. Install galvanized metal lath over roofing felt membrane. B. Apply scratch coat consisting of 1 part Portland cement to 4 parts damp sand. C. Apply mortar bed of 1 part Portland cement to ½ part lime to 5 parts damp sand by volume. D. Install mortar bed in accordance to ANSI A108.1B E. Install Stone Veneer in accordance with manufacturer s printed instructions and ANSI A108.5. 1. Apply thin set mortar to backer board combing in one direction. 2. Apply thin set mortar to the back of the Stone Veneer. 3. Place Stone Veneer into the freshly spread thin set, tapping into place insuring 100% coverage. F. Grout Stone Veneer in accordance with manufacturer s printed instructions and ANSI A108.10. G. Install veneer Stone Veneer as per MAPEI detail CA2E87 H. Where Stone Veneer abuts columns, window and doorframes or any dissimilar surface leave a3/8 gap to be filled with compressible caulking. I. Install expansion and control joints lengthwise and crosswise at regular intervals according to specifications and in accordance with TCA method EJ171. 3.5 CLEANING and SEALING A. Remove all surface residues of thin set and grout from surface of Stone Veneer while it is still fresh. B. Do not clean with harsh chemicals or acids. C. Seal Stone Veneer as per manufacturer s recommendations. 3.6 PROTECTION A. Protect walls from impact, vibration and heavy hammering on adjacent and opposite walls for at least 14 days after installation. - 4

END OF SECTION - 5