Trees and powerlines. Office of the Technical Regulator. sa.gov.au/energysafe



Similar documents
Trees and powerlines. Office of the Technical Regulator. Web: sa.gov.au/energysafe Phone:

Trees, powerlines and your property

SA Power Networks Protocol for vegetation management near powerlines

Tree Management Policy

The Electrical Safety Regulation (pre and post 1 January 2014)

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR OVERHEAD ELECTRIC LINES

Living with Electricity Easements

Electrical Safety Tips. Help us keep you safe

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

High Voltage. Hazards

A GUIDE TO PLANTING AND MANAGING TREES NEAR POWERLINES

Transmission Business Electrical Incident & Safety Performance Reporting Guide

Code of Practice Electricity transmission and distribution asset management. February 2009

Before You Build How to stay away from power lines

Public Utility District #1 of Jefferson County Vegetation Clearance Policy And Specifications

BUILDING OR RENOVATING

Q. Why does OG&E clear vegetation away from power lines? A. Trees that grow into power lines can cause problems in multiple ways:

AS 4708:2013. Interpretation of Requirements relating to the Recovery of Forest Products from a Water Body

Avoiding Tree & Utility Conflicts

TREE CUTTING & TRIMMING INFORMATION As of

Technical Guidance Note 287. Third-party guidance for working near National Grid Electricity Transmission equipment

Please check with your local inspection authority for any additional requirements before installation.

This Facilities Extension Agreement is entered into by and between Fmt B«nd Onmrt,

Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.

LAND USE CODE CHAPTER GENERAL REGULATIONS

ALCOA OF AUSTRALIA LIMITED BUSHFIRE MITIGATION AND LINE CLEARANCE PLANS 2013/2014

NEW ZEALAND ELECTRICAL CODE OF PRACTICE. for ELECTRICAL SAFE DISTANCES

Energex Customer Charter. For residential and small business customers

Indicative costs for replacing SWER lines

KUB Tree Pruning: A Customer Guide

CITY OF ELBERTON, GEORGIA REQUEST FOR PROPOSAL

Networks. Code of Practice for Avoiding Danger from Overhead Electricity Lines

environment briefing02

DOCUMENT NAME: ITDH1 UTILITY EASEMENTS GRANTED ( )

Tree Trimming Practices. For transmission and distribution power lines. TREE TRIMMING PRACTICES h 1

Trimming Trees Near Electric Lines. Understanding Niagara Mohawk s Role and Responsibilities

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Accident Bulletin 2/2012 (An update to Accident Bulletin 3/2011) Aerospatiale SA 315B LAMA helicopter

Hendrix Spacer Cable

ARTICLE 167 Shade Tree Commission, Shade Trees

MEMPHIS LIGHT, GAS AND WATER DIVISION LINE CLEARANCE

DISTRIBUTION OPERATIONS AND MAINTENANCE

DALLAS COUNTY, IOWA CHAPTER 48 SMALL WIND ENERGY CONVERSION SYSTEMS ORDINANCE FOR THE UNINCOPORATED AREA OF DALLAS COUNTY, IOWA

APPENDIX D DISTRIBUTION WIRES ONLY RATE BASE

Trees and Reliable Electric Service. Answers to Questions About Tree Pruning and Electric Power. We re connected to you by more than power lines.

2002 No ELECTRICITY. The Electricity Safety, Quality and Continuity Regulations 2002

OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993

Treasure Valley Electric Plan - Community Advisory Committee

MAINTENANCE AND REMOVAL OF TREES ON VERGES

Asset Management Strategy

3. This writ was filed for the Plaintiff by Mr Brendan Pendergast of Maddens Lawyers, Warrnambool. 7 Vanessa Drive MICKLEHAM Victoria 3064

Distribution Business Electrical Safety Performance Reporting Guidelines

Tree Work on District of West Vancouver Property

City of Alcoa Electric Department Tree Trimming Policy

Electric Line Clearance Management Plan

Transmission/Distribution Vegetation Management Program. Flathead Electric Cooperative,Inc. Powerful Solutions. for our communities

ISSC 20 Guideline for the Management of Activities within Electricity Easements and Close to Electricity Infrastructure

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

Guide To Trees And Power Lines

Washington DC Power Sector Overview

Excavation & Trenching Procedure

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Facilities Management Services Arrangements. 1 July 2015 to 30 June 2024

Electric system improvements near you South and West of Edmonton Area Transmission Development

Chapter 162 SHADE TREE COMMISSION

Standard terms and conditions

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Complete Solar Photovoltaics Steven Magee. Health and Safety

Vegetation Management. for Distribution Lines

FRAMEWORK FOR UNDERTAKING WORK NEAR OVERHEAD AND UNDERGROUND ASSETS

CHAPTER 13 SUB-ANALYSIS CHAPTER 14 SUB-ANALYSIS

Case Study: HV Cable Strike With Steel Pin Whilst Erecting A Marquee:

Underground Commercial Electric Service

ABN Mannum Road Phone: (08) PO Box 586 Fax: (08)

APPENDIX "F' TREE REMOVAL F-1

Handbook 16. Handbook 16. AC electrified lines. GE/RT8000/HB16 Rule Book

Service & Installation Rules 2014

June July 18, of 7

GroundRod AC Substation Earthing Tutorial

Overhead lines Asset Management in the Belgian network. S. GERMAIN K. VAN DAM B. RISSE JF. GOFFINET Elia Belgium

HURRICANE SANDY One Year Later A LOOK BACK AT ATLANTIC CITY ELECTRIC S STORM RESTORATION EFFORTS

November General Notes. Tree Protection. Tree Protection and New Development Guidance Note

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

Avoiding danger from overhead power lines Guidance Note GS6 (Fourth edition)

SUBDIVISION APPLICATION GUIDE

Promoting Tree Health and Electric Safety. Important Numbers

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Transcription:

Trees and powerlines Office of the Technical Regulator sa.gov.au/energysafe

owerlines are an important part of our everyday lives, bringing electricity to our homes and businesses. egetation needs to be cleared from powerlines to avoid power outages, damage to the lines, fires or risks to people s safety. It is a legal requirement that electricity network operators and occupiers of private property maintain safe clearance distances between vegetation and powerlines. Maintaining clearance zones around powerlines who is responsible? The clearance distances between vegetation and powerlines are legal requirements outlined in the Electricity (rinciples of egetation Clearance) Regulations 2010. The responsibility for pruning vegetation usually lies with the electricity network operator usually SA ower Networks or, for the large transmission powerlines on steel towers, ElectraNet. On private properties, the occupier of the property may be legally responsible for managing vegetation near powerlines, however, it depends on the type of powerline and vegetation. See image 1 and the following explanations for more details. Responsibilities of the occupier The occupier of a private property is responsible for keeping the required clearance zone free of planted or nurtured vegetation around the powerlines that supply their property. This responsibility does not apply to naturally occurring vegetation. If the powerlines supply electricity to more than one property then it is the electricity network operator s responsibility to trim the vegetation along the section of powerline which services those properties. If you are considering planting new trees near powerlines, see page 6. Responsibilities of the electricity network operator In South Australia the electricity network operator is responsible for maintaining the clearance zone around all public powerlines including trees hanging onto the road reserve from private property. On private land, the network operator is responsible for keeping naturally occurring vegetation away from powerlines. Where a powerline crosses private land and supplies electricity to more than one property, it is deemed to be a public supply line and vegetation clearance is the responsibility of the network operator. In some circumstances a local council may agree with the network operator to take over the responsibility for pruning. Determining required clearance distances between vegetation and powerlines advice for occupiers To determine the required clearance distance of vegetation from a powerline you need to know: if the powerline is located in a defined bushfire risk area the voltage of the powerline the type of conductor i.e. fully insulated or uninsulated the span, or distance, between stobie poles or transmission towers powerlines with greater span length can swing and sag further under windy and hot conditions and require greater clearance distances. the location of vegetation in relation to the closest stobie pole powerline movements are greater midway between stobie poles and a greater clearance zone is needed. Which areas are defined as bushfire risk areas? The Adelaide ills and most regional areas are considered bushfire risk areas. Most of the Adelaide metropolitan area and many developed townships are non-bushfire risk areas under the regulations. Find out if your property is in a bushfire risk area by contacting the Office of the Technical Regulator or refer to Schedule 4 of the Electricity (rinciples of egetation Clearance) Regulations 2010. Determining the voltage and type of powerline Find out the voltage of the powerlines by: visiting sa.gov.au/energy/powerlinesafety contacting the Office of the Technical Regulator on 8226 5500 contacting SA ower Networks on 1300 650 014. igh voltage powerlines are those of more than 1,000 (1 k) of electricity. Low voltage powerlines refer to lines of less than 1,000. Images 2 and 3 show common types of powerlines in South Australia. Clearance zones A clearance zone is the minimum safe distance between vegetation and powerlines. It allows the powerlines to safely swing in windy conditions without being damaged or starting fires. It is a legal requirement for the clearance zone to be kept free of vegetation at all times. 2 Building safely near powerlines

lanted vegetation Occupier responsibility ublic powerlines (more than one customer) Electricity distributor responsibility lanted vegetation Occupier responsibility Naturally occurring vegetation Electricity distributor responsibility Naturally occurring vegetation Electricity distributor responsibility LEGEND rivate supply line ublic supply line lanted vegetation on private property No trimming required ublic powerlines Electricity distributor responsibility Electricity distributor responsibility (Normally SA ower Networks) Image 1: runing responsibilities Buffer zone igh voltage 11k ertical () and horizontal () dimensions of the clearance zone vary according to the type and voltage of the conductor Clearance zone Service line Low voltage owerline conductor Image 4: Cross section of a powerline showing the clearance and buffer zone Image 2: Typical powerlines in built up areas No ceiling for the clearance zone 5 metres 33 k, 66 k or 132 k 33 k, 66 k or 132 k 33 k or 11 k 19 k (SWER) Maximum height of the buffer zone equals the height of the pole plus 5 metres 45 45 Image 3: Common powerlines in South Australia Image 5: Buffer zone for uninsulated powerlines in bushfire risk areas Buffer zones For private properties in non-bushfire risk areas, the buffer zone surrounding a clearance zone is: A buffer zone is an additional area around a clearance zone. It defines the maximum extent to which the vegetation may be trimmed. Trimming beyond the buffer zone is not permitted. Trimming vegetation within the buffer zone will usually allow the clearance zone to remain clear until the next trimming is due. 2 metres for distribution powerlines (low voltage) 3 metres for high voltage transmission powerlines (normally on steel towers). Image 5 shows an example for the shape of the buffer zone that applies to uninsulated distribution powerlines in bushfire risk areas. For more information visit sa.gov.au/energysafe 3

Clearance zone dimensions Dimensions for clearance zones vary according to the type of conductor and its location. Images 6, 7, 8 together with table 1 below show the requirements for the most common scenarios as described below. 2.0 m Non-bushfire risk areas Fully insulated powerlines (all voltages) and uninsulated low voltage powerlines A clearance zone of 0.1 metre is required. Uninsulated high voltage powerlines The clearance zone depends on the voltage and span of the powerlines, see image 7 and table 1 for the required distances. The middle sections of a cable between two poles can swing or sag more than the sections closer to the poles and require greater vertical and horizontal clearances. 0.1 m 2.0 m 2.0 m Bushfire risk areas Fully insulated powerlines A clearance zone of 0.1 metre is required. 0.1 m 2.0 m Image 6: Fully insulated powerlines in all areas and low voltage powerlines in non-bushfire risk areas Uninsulated powerlines The clearance zone depends on the voltage and span of the powerlines, see image 8 and table 1 for the required distances. There is no ceiling on the vertical clearance above the conductor. The middle sections of a cable between two poles can swing or sag more than the sections closer to the poles and require greater vertical and horizontal clearances. Insulation of powerlines oltage of powerlines All spans Span in metres, =ertical, =orizontal 0 50 m 50 100 m 100 150 m 150 200 m 200 300 m 300 400 m Over 400 m ole, Insulated All voltages in all areas 0.1 0.1 0.1 0.1 0.1 0.1 0.1 - - - - - - - - Bare or partially insulated (covered) Less than 1 k in non-bushfire risk areas Less than 1 k in bushfire risk areas 0.1 0.1 0.1 0.1 0.1 0.1 0.1 - - - - - - - - 0.5 1.0 1.0 1.5 2.5 1.5 3.5 - - - - - - - - 7.6 k and 11 k in all areas 0.5 1.5 1.5 2.0 2.5 2.5 3.5 2.5 4.5 2.5 6.0 2.5 6.0 2.5 6.0 19k in all areas 0.5 1.0 1.0 1.0 1.0 1.0 2.5 1.0 2.5 1.5 5.0 2.0 7.0 2.0 9.0 Table 1: Clearance zone dimensions for various types of powerlines in bushfire and non-bushfire risk areas 4 Building safely near powerlines

1/4 of the Clearance zones shown at the pole and in mid span for high voltage conductors ( and dimensions are from the outer conductor positions in still air) 1/4 of the iew of the clearance zone from above 1/2 of the and dimensions are constant for the centre half iew of the clearance zone from the side Mid length 1/2 Mid length 1/2 Image 7: Uninsulated powerlines in non-bushfire risk areas (private land) No ceiling No ceiling No ceiling 1/4 of the 1/2 of the Maximum height of the buffer zone equals the height of the pole plus 5 metres and dimensions are constant for the centre half and dimensions are from outer conductor positions in still air in mid span and is the dimension from conductors at the pole. iew of the clearance zone from above iew of the clearance zone from the side No ceiling Mid length 1/2 Mid length 1/2 Image 8: Uninsulated powerlines in bushfire risk areas For more information visit sa.gov.au/energysafe 5

Safety when working near powerlines Working near powerlines can be dangerous. If you intend to carry out the vegetation clearance yourself, you need to be familiar with safety principles of working near powerlines. Contact the Office of the Technical Regulator or visit sa.gov.au/energysafe for further details. If you do not wish to carry out the maintenance yourself, consider hiring a professional contractor to clear the vegetation for you. Emergency clearances during fire danger season During fire danger season, vegetation that is too close to powerlines can be an extreme fire hazard. If the occupier has not maintained the safe clearance zones around the private supply lines, the electricity network operator may clear the vegetation. The electricity network operator may also recover the cost of this work from the occupier. If the electricity network operator is unable to clear the vegetation in time, the supply lines may be disconnected at the occupier s expense. The disconnection may affect other properties in the area. Clearance objections and complaints The electricity network operator has to give the occupier 30 days notice prior to commencing vegetation clearance on private property. Emergency clearances are exempt from this requirement. Any objection to the proposed clearance should be discussed with the electricity network operator. If the objection is unresolved, you may contact the Office of the Technical Regulator for further clarification. You can also lodge a written objection with the Office of the Technical Regulator (within 21 days of receipt of the notice) about matters set out in the notice. lease note that the Office of the Technical Regulator may not consider your objections if you have not attempted to discuss and resolve them with the electricity network operator. lanting trees near powerlines lanting limitations To minimise the impact of trees growing too tall and into the clearance zone, the type and location of trees you can plant near powerlines is limited by legislation. Which trees can I plant? The mature height of a tree is the main criteria to determine how close it can be planted to particular types of powerlines. There are two lists of trees that are permitted within certain distances to powerlines: list 1 trees with mature height of 3 metres or less list 2 trees with mature height of 3 6 metres In addition to the trees on the two lists, all vegetation with a mature height of 2 metres or less is exempt from the planting restrictions. Tree lists 1 and 2 are available from the Office of the Technical Regulator or online at sa.gov.au/energysafe. lanting distances lanting limitations only apply within a certain distance from the powerlines. This distance depends on the voltage and insulation of the powerlines and whether the powerlines are located in a bushfire risk area. owerline voltage rescribed distance in metres from the centre of the pole/tower 275,000 12.5 m 132,000 excl. single poles 15 m 132,000 single poles 10 m 66,000 6.5 m All other voltages 6 m Table 2: rescribed distances for planting near powerlines Image 9: lanting near uninsulated powerlines in bushfire risk areas 6 Building safely near powerlines

lanting within bushfire risk areas lanting within the prescribed distance Unless powerlines are fully insulated, only trees from list 1 and trees with a mature height of less than 2 metres can be planted. For insulated powerlines, only trees from list 1, list 2, and trees with a mature height of less than 2 metres can be planted. lanting within the area from the prescribed distance to double the prescribed distance Only trees from list 1, list 2, and trees with a mature height of less than 2 metres can be planted. lanting beyond double the prescribed distance Any tree can be planted. lanting within non-bushfire risk areas or where powerlines are fully insulated lanting within the prescribed distance Only trees from list 1, list 2, and trees with a mature height of less than 2 metres can be planted. lanting near underground powerlines Near an underground powerline of 66 k or more, only trees from list 1 and trees with a mature height of less than 2 metres can be planted within 3 metres of the centre of the underground powerline. Applying for an exemption The Technical Regulator may grant an exemption from planting restrictions. If you intend to plant a tree that is not permitted by the regulations near a powerline, you must first apply for an exemption. Except for timber plantations, the Technical Regulator may grant an exemption from planting restrictions following consultation with the electricity network operator. The exemption typically includes conditions that a person must manage and maintain the vegetation and clearance distances and that it will be reviewed if the occupier or owner of the property changes. Trees that are permitted to be planted under an exemption from planting restrictions will still need to be kept trimmed to the regulation distance from the powerlines. lanting beyond the prescribed distance Any tree can be planted. All areas planting near fully insulated powerlines lanting within the prescribed distance Only trees from list 1, list 2, and trees with a mature height of less than 2 metres can be planted. lanting beyond the prescribed distance Any tree can be planted. Image 10: lanting near all powerlines in non-bushfire risk areas or near insulated powerlines in all areas Image 11: lanting near 66 k underground powerlines For more information visit sa.gov.au/energysafe 7

Related information See our Building safely near powerlines brochure for information on safe clearance distances. See our Working safely near overhead powerlines brochure for information on the many hazards associated with working in proximity to powerlines and how to manage these hazards, including when trimming vegetation. Building safely near powerlines Working safely near overhead powerlines Office of the Technical Regulator Office of the Technical Regulator sa.gov.au/energysafe sa.gov.au/energysafe This information is provided to offer general guidance only on trees and powerlines, and does not purport to cover all situations, or any particular situation, or to outline a complete list of procedures that must be followed. It is not to be taken as a statement of law or legal advice, and must not be construed to waive or modify any legal obligation. The Government of South Australia will not be liable for any injury, damage or loss of any kind sustained by any person that arises directly or indirectly from reliance upon any information contained herein or source of information referred to. For more information Online: sa.gov.au/energysafe Email: dsd.otr@sa.gov.au hone: 08 8226 5500 July 2016