Category 5 Outside Plant



Similar documents
Power over Ethernet (PoE)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

AXIS T81B22 DC 30W Midspan

InstaPATCH Cu Cabling Solutions for Data Centers

E Series. E Series. Category 6 and 5e. Features

COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.

Laying the groundwork for a new level of Power over Ethernet

Uniprise Solutions COAX 101. White Paper.

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

How To Make Power Over Ethernet A Viable Alternative To A Network Cable (Networking)

8-Port PoE Network Switch

IFS SP-PoE Splitter User Manual

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

White Paper. Power over Ethernet Plus Update and Cabling Considerations

Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

3Com WHITE PAPER. Power over Ethernet Overview

Power over Ethernet. IEEE 802.3af

Design Guide. SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines. June 2015

SYSTIMAX Copper Solutions Designed for the Digital Generation

Communication, Signal & Data Cables

Ethernet over Copper Transmission Extenders

CommScope Intelligent Building Infrastructure Solutions (IBIS)

3M xdsl Line Conditioners 3620

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

, User s Manual

Power over Ethernet technology for industrial Ethernet networks

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

Design Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.

Data Center Topology Guide

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Government. Network and Communications Infrastructure for Federal Government

MultiVOIP FX SIP Gateways

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Specification SFTP CAT6 Network Cable 23AWG CU

How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell)

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

800 Communications Circuits

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Toroidal Conductivity Sensor

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

Industrial Ethernet The Perfect Cable for an Imperfect Environment

INSTALLATION GUIDE 1

APR 2016 Rev M

SECTION LOW VOLTAGE LIGHTING CONTROLS

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

T7560A,B,C Digital Wall Module

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Power over Ethernet (PoE) Explained

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

TrueAlarm Fire Alarm Systems

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Radiant Temperature Sensor TY7321

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

How To Create An Intelligent Infrastructure Solution

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Upgrading Path to High Speed Fiber Optic Networks

Power over Ethernet for VoIP Applications. White Paper

HMI display Installation Guide

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Voice Boxes, Cabinets & Accessories

Solar monitoring gateway quick start guide

Multi Media Cable Tester TM-901N/TM-902/TM-903

AN SMSC Design Guide for Power Over Ethernet Applications. 1 Introduction. 1.1 Power Over Ethernet

The SYSTIMAX ipatch System

Power over Ethernet (PoE) Power Requirements FAQ

Duct Humidity Transmitter

HARTING Ethernet Cabling 4-poles Overview

Building Cables and Wires

8-Port PoE Network Switch

HGS620 Shielded Outlet Termination Instructions

About Your NetBotz 4-20mA Sensor Pod

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

SMART Board interactive flat panel with appliance Model 8055ie-SMP

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

MechoNet TM Network Interface (MNI) Specification Submittal

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Power Over Ethernet POE IS NOW HERE!!!

imvision System Manager

Canopy Surge. User Manual

Wireless Indoor/ Outdoor Thermometer

8146/5 Series Breaker Panelboards

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Transcription:

SYSTIMAX Solutions Category 5 Outside Plant Application Guide www.commscope.com

Contents Design Option 3 Installation Cable Blocking Instructions 4,5 Mounting SYSTIMAX Protector 6 Mounting Additional Protectors 6 Bond to Approved Ground 7 Terminate OSP Cable 8 Terminate Equipment Cable 9 Install Cover 10 Troubleshooting a Non-Functioning Channel 11 VoIP Operation 11 Analog Phone Operation is Not Supported 11 PoE Operation 11 1571 Cat 6 OSP Cable Replaces Cat 5 OSP Cable 12 Specifications and Ordering Information Protectors 12 Specifications and Ordering Information 1571 Cable 13 www.commscope.com 2

Design Options www.commscope.com 3

Cable Blocking The water repelling gel may leak from the end, so it should be blocked before termination. A vertical drop to the protector and/or high temperatures may aggravate this. After removing the jacket end, carefully wipe the excess gel from the end, and then follow the steps below. www.commscope.com 4

www.commscope.com 5

Mounting The SYSTIMAX Cat 5 Protector Mounting Additional Protectors www.commscope.com 6

Bond To Approved Ground www.commscope.com 7

Terminate OSP Cable www.commscope.com 8

Terminate Equipment Cable www.commscope.com 9

Install Cover www.commscope.com 10

Troubleshooting A Non- Functioning Channel After an over-voltage incident below 16V, the protector will automatically reset and continue functioning. If the channel does not carry a signal, the protector should be checked for the following conditions: Fail - short In this instance, the protector has failed with one or more of the eight wires shorted to electrical ground. Use an Ohmmeter to see if there is a value of 1000Ω or less between the ground screw of the protector and any of the wires on the protected or unprotected sides of the unit. The end equipment should be disconnected during this test. If this condition is found, the protector must be replaced. Fail - open In this instance, the protector has failed by leaving one or more of the eight wires between the entry wiring termination and the equipment side termination open. Use an Ohmmeter to see if there is a value of 10Ω or greater between sides of the protector. The end equipment should be disconnected during this test. If this condition occurs, the protector must be replaced. A supply of replacement units should be stocked at all times. VoIP Operation Do not use the C5P4T-16 Protector when PoE powers VoIP phones. The PoE voltage will be clamped at 16V. Substitute with the Cat 6-16v with PoE Protector (MID Number 760033951). Wire per Category 6 Outside Plant Design and Installation Guidelines found at: http://docs.commscope.com/public/cat6_osp_d_and_i_guidelines.pdf Analog Phone Operation Is Not Supported With Category 5 Protectors The protectors used at both ends of the Category 5 channel do not support the use of standard analog telephone equipment. This is because the protector is designed for LAN use only and the clamping voltage threshold of 16V will not permit a standard analog phone to operate properly. The 110 ANA1-Type Multi-pair Protector Panel may be used for voice applications. PoE Operation There are two types of PSE (Power Sourcing Equipment) that are defined for PoE per the IEEE802.3af standard. They are Midspan and Endspan PSE s. Midspan PSE s - The SYSTIMAX Cat 6 16V w/ PoE Protector (MID 760033951) is compatible for use with all Midspan PSE s. - All SYSTIMAX PSE s, Models 1200, 2400 & 2400G, are Midspan and power is supplied per PoE Standard IEEE802.3af Alternative B (power is run on cable pairs 1 & 4). www.commscope.com 11

Endspan PSE s - The SYSTIMAX Cat 6 16V w/ PoE Protector (MID 760033951) is not compatible for use with Endspan PSE s that run power per Alternative A (power is run on cable pairs 2 & 3). - The SYSTIMAX Cat 6 16V w/ PoE Protector is compatible for use with Endspan PSE s that run power per Alternative B. - The cable designer and/or installer must verify with the customer whether Alternative A or B is being deployed in Endspan PSE. SYSTIMAX does not sell a PoE protector that supports Alternative A. 1571 Cat 6 OSP Cable Replaces Cat 5 OSP Cable Please note that SYSTIMAX Cat 5 OSP Cable has been manufactured-discontinued and replaced by SYSTIMAX 1571 Cat 6 OSP cable. 1571 Cat 6 OSP Cable shall be used for both PowerSUM and GigaSPEED XL installations. A Channel comprised of 1571 OSP Cable and GigaSPEED XL Connecting hardware provides Category 6 channel performance. The cable should be placed in conduit whenever possible. If it is to be installed as aerial placement, appropriate support means must be used as the cable does not have integral support members. It is not recommended for direct-buried applications as it does not have mechanical protection. This cable is not fire-rated for indoor use. Protector Type Specifications and Ordering Information Protectors 100% Solid State Clamping Voltage 16V 16V Data (or/gr) 62V Power (bl/br) Response Time Grounding Requirements Grounding Connection Physical Dimensions Standards Compliance 2-5 nanoseconds #10 AWG (min) #8-32 Screw to ground plane on module 4.25 L x 4.25 W x 1.42 D UL497 Product Code C5PAT-16** Cat 6 16V w/poe* Material ID Number 108224874 760033951 * See the PoE Operations Section starting on Page 11 ** Does not support PoE www.commscope.com 12

Specifications and Ordering Information OSP Cable Cable Type Cable Sheath Water-Displacing Compound End Blocking 4-Pair #23 AWG UTP Polyethelene Flooding Compound Not needed Cable Diameter 0.250 Product Code 1571 Cat 6 Cable Material ID Number 760008888 www.commscope.com Visit our Web site or contact your local CommScope representative for more information. 2011 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. 07/11