sealed close coupled pumps



Similar documents
BASIS RANGE TMB SERIES

Vertical selfpriming Side-Channel Pumps Type WPV

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

Multistage high-pressure multistage centrifugal pumps

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

CRK A-W-A-BUBV

MAGNETIC DRIVE PUMPS M35 TO M200 RANGE

4" SUBMERSIBLE PUMPS

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

The conditions below apply to the curves shown on the following pages.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

IN series. Centrifugal pumps standardized to DIN-24255

Mechanical shaft seal types and sealing systems

Conlift1, Conlift2, Conlift2 ph+

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

CG PTFE Diaphragm Liquid Transfer Pump

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

How To Use A Flowmeter

SJT / SJM / SJP Large Vertical Pumps

PS1800 Centrifugal Pumping Systems

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

MEMBRANE VACUUM MINI PUMPS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Digital inductive conductivity transmitter

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

RUBBER SLEEVE KNIFE GATE VALVE

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

kymanual or Automatic - it s your Choice

Thermostatic valve Type AVTA

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps

Series description: Wilo-Yonos MAXO

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

NDP-50 Specifications

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Radial piston pumps type R and RG

ABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist

Solenoid valves Type EVU

Series description: Wilo-Drain TC 40

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

PUMP AND MOTOR DIVISION

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Uniquely designed and engineered specifically for the pulp and paper industry.

API Flanged Safety Relief Valves Series 526 CATALOG

Series description: Wilo-Yonos MAXO-D

Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

V47 Series Temperature Actuated Modulating Water Valves

How To Pump A Pump

Laing industrial pumps

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Vertical Pumps for the Oil & Gas Industry

Rules for Classification and Construction Additional Rules and Guidelines

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Heating, air-conditioning, cooling

HTM SS Metallic mag drive centrifugal pumps. HTM SS Pompe centrifughe a trascinamento magnetico in metallo FEATURES

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Rickmeier Solutions. Gear pumps for superior Lubrication

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Solenoid valves 2/2-way direct-operated Type EV210A

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

HOPPER SHAPE KNIFE GATE VALVE

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Flygt 3068, 50Hz. Technical Specification

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Energy Recovery Device isave 21-40

08.08 Vic-Check Valves

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Manual piston sampler...m 11

EVALUATION ACCORDING TO ASTM F

MAGNETIC DRIVE SEAL-LESS PUMPS

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Process Equipment Catalog Pumping Solutions for Process Industries

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Power consumption (kw)

Transformer oil cooler ALFA A02

Transcription:

sealed close coupled pumps centrifugal self-priming

1 - and are different configurations of the same range of centrifugal axle pumps, self-priming which offers reliability in use. Specifically designed to handle chemical and corrosive fluids. The whole structure has been conceived in order to make all the components extremely resistant to the aggression, even in the smallest parts. The pump is close coupled and the parts are supported by the motor, therefore the dimensions are restricted. Front suction, central upward delivery, mechanically sealed with sliding counterfaces (with an external, single or double flush) or radial elastic ring. The motors with specially designed shaft and flange are usually IP 55 protected, with Class F Insulation, 20 voltage, three phase with Hz frequency. This range is close coupled, with pump casing supported directly by the motor. These are optimal when needed to transfer chemicals with a specific gravity up to 1,8. Three different motors are available for each model. The impeller is open, so there is no contraidication to transfer liquids containing solids in suspension. Self-priming without the need of having check valves. Thanks to the specific structure, after the first filling, they are able to self-prime automatically even in presence of empty pipes. Negative suction head of 5 meters (to be reduced according to the specific gravity). As in the range, there are different motors available and the impeller is open. 51 1 1 21 100

- 2 GENERAL PERFORMACE CURVES U.S. (gpm) 0 100 1 200 2 00 5 1 10 2900 r.p.m. - Hz 120 5 21 110 100 0 90 Head (m) 20 1 21 1 70 Head (ft) 15 1 100 10 0 5 20 10 0 m h Capacity L1' 0 10 20 0 70 0 100 200 00 0 0 0 700 0 900 1000 1100 0 11 1 51 615 NOTES. All curves are referred to: water at 20 C - viscosity 1 E - specific gravity 1 kgdm PUMP SPECIFICATIONS table 1 PUMPS 100 1 21 21 1 1 1 11 1 51 615 Ø inlet (BSP) Ø outlet (BSP) ISO flange ANSI flange DeA DeM NDA NDM NDA NDM 1 f 1 m 1 f 1 m 2 f 1 2 m 2 2 2 2 65 65 65 65 1 f 1 f 2 2 2 2 1 2 f 1 2 f 2 f 2 f 2 2 f 2 2 f Motor power kw 0,75 1,1 5.5 0,75 1,1 Phases Std. voltage Motor protect. N V IP 0 5% 55

- THE MATERIALS table 2 Version WR WF FC QR Reinforced Polymers PVDF UPVCPVDF Min temp. -5 C (2 F) -5 C (2 F) -0 C (-22 F) 0 C (2 F) Max temp. C (176 F) C (176 F) 110 C (20 F) C (10 F) Environment temp. 0 C (1 10 F) 0 C (1 10 F) -20 C (- 10 F) 0 C (1 10 F) WR - The main resin is PP (polypropylene) reinforced with 0% glass fibre. It has a good mechanical resistance and has good dimensional stability when hot. WF - The main resin is PP (polypropylene) reinforced with 0% fibre glass. The main components are in PVDF because this material has got a higher resistance to abrasion and use. FC - The main resin is PVDF (Vinylidene polyfluoride) reinforced with 20% fibre glass. Good resistance to abrasion and is also mechanically resistant. QR - Main resin is PVC (Polyvinyl chloride). Other parts are made in PVDF. This version is particularly suitable to chromic acid, sulphur nitrite mixtures, sulphuric acid, sodium hypochlorite, turpentine and ozone. ELASTOMERS table Version V E K Material EPDM F Description Fluorine elastomer Ethylene-propylene rubber Perfluorelastomer THE CONSTRUCTION OF MECHANICAL SEALS table MECHANICAL SEALS SEAL MODEL ROTATING PART FIXED RING BELLOWS 2^ ROTATING PART 2^ FIXED RING External - Single T1 T T PTFEGFR PTFE T5 EPDM T8* T6 EPDM Double T9 T10 EPDM * Radial seal T1 T T T6 SPECIFICATION OF MECHANICAL SEALS table 5 Condition of work Model Tipology Code Clean chemical mediums max pressure bar Clean chemical mediums suspended solids Concentrated acids no suspended solids Clean chemical mediums hard suspended solids General purpose Clean chemical mediums low cost Suspended solids Hard suspended solids salts T1 T T T5 T6 T8 T9 T10 Single external, elastomer bellows Single external, elastomer bellows Single external, PTFE bellows Single external, elastomer bellows Double flushed, elastomer bellows Elastomeric radial seal Double flushed, elastomer bellows Double flushed, elastomer bellows 10 0 16 9 51

- THE CONSTRUCTION OF PUMPS table 6 Versions Pump casing Bracket Impeller Ogive Diaphragm Sleeve Gasket Baseplate Screws (1),(2) Upon request: (1) EPDM, (2) F WR WF FC PP GFR-PTFE (1) PP GFR-PTFE (1) PVDF PVDF (1),(2) QR PVC GFR-PTFE GFR-PTFE (1),(2) TECHNICAL SPECIFICATIONS 6 7 1 Stable dimension and strong structure guaranteed by the molding of thermoplastic materials; these features are insured by the thickness of each part. 1 2 Bracket with large windows in order to void accumulation of corrosive vapours 2 21 with T mechanical seal Solid plastic open impeller with metal core to allow frequent start-stop cycles 6 7 Diaphragm: special building procedure limits the damages in case of dry running and allows a quicker intervention and easy maintenance 1 5 Sleeve: a good protection of the shaft 5 2 1 with T6 double mechanical seal 6 Simple construction: only two parts (casing and bracket) carry out all the hydraulic and mechanical process by reducing the surface of static sealage (OR) 6 7 7 Total interchangeability of the most common mechanical seals. There are different types according to the liquid pumped 8 Screws and nuts in stainless steel 1 2 8 1 with T mechanical seal

5 - IDENTIFICATION LABEL table 7 100 WR V T1 B kw SERIES CHOOSE MODEL MATERIALS V = E = EPDM K = F INTERNAL STRUCTURE B = thr. BSP Z = flange ISO-ANSI MOTOR POWER SERIE MODEL VERSION O-ring MATERIALS MECHANICAL SEAL CONNECTIONS kw 100 1 WR V 10 1 0 B 0,75 21 1 1 21 1 WF E 16 9 51 Z 1,1 FC K INSTALLATIONS PROCEDURE table 8 If the specific gravity is more than 1 Kgdm the maximum suction head is to be reduced (see diagram 1). If the temperature is more than 20 degrees Celsius the maximum suction head is to be reduced (see diagram 2). To self-prime liquid with considerable emission of fumes at normal condition (1 atm; 20 C) is permittable with limited suction head (e.g. HCL). Maximum value of kinematic viscosità iis 10 cst. An increase of the nominal diameter of the pipes involves an extension of the self-priming time. In presence of suction horizontal pipes the priming time is extended (e.g. at Ha = 5 m with horizontal pipe lenght of one meter the priming time is of 5.2 minutes [only.2 min. with vertical pipe]). Planning the complex system do keep the priming time less than 6 min. ad the NPSH value more than 0, atm. (for liquids at room temperature). Siphon-shaped pipes (filled with liquids) could hamper the air flow during the priming phase. In the suction tank the surface of the liquids must be at atmospheric pressure. The delivery pipe outlet has to work at atmospheric pressure. (a) (a) Min. 0,5 m HA HA table 9 Suction head HA (m.c.l.) Diagram 1-6 γ = 1-5 - - γ = 1, γ = 1,6 γ = 1,8-2 γ = 2-1 0 0 1 2 5 6 Priming-time t (min.) Example: liquid: NaOH 2 Bè (γ = 1,1 Kg dm) T= C plant: HA = 2 m suction head check diagram 1: HA max (rif.: γ = 1,1 Kg dm) =,5 m diagram 2: rh (rif.: T = C) = 0,7; HA max =,5 x 0,7 = 2,5 m (> 2; OK). Please contact us in order to give you our technical support and assistance. γ = (Kgdm) specific gravity of the liquid. TS = boiling or decomposition temperature ( C). rh Coefficient of reduction of 1 0,8 0,6 0, 0,2 Diagram 2 Ts = 100 Ts = Ts = 20 0 70 Temperature of liquid T ( C)

- 6 IDENTIFICATION LABEL table 10 51 WR V T1 B kw SERIES CHOOSE MODEL MATERIALS V = E = EPDM K = F INTERNAL STRUCTURE B = thr. BSP Z = flange ISO-ANSI MOTOR POWER SERIE MODEL VERSION O-ring MATERIALS MECHANICAL SEAL CONNECTIONS kw 11 1 51 615 WR V 10 1 0 B WF E 16 9 51 Z FC K 0,75 1,1 QR DIMENSIONS table 11 KM DnM P KM DNM Ø d x z P G L DeM a1 Ø d x z DeM h1 h Ø d x z h1 h2 DeA h2 h1 DaM h Ø d x z DNA KA s1 h n1 s2 m1 r rb a2 B2 B L L1

Production Program TMB range Installed powers: W 15 100 Bodies materials: GFRPP Magnetic drive AM range Installed powers: kw 0,18 0,55 Bodies materials: GFRPP - E-CTFE Magnetic drive ROUTE range Installed powers: kw 0,55 Bodies materials: GFRPP - CFFE-CTFE Magnetic drive FRONTIERA range Installed powers: kw 0,55 15 Bodies materials: PP - E-CTFE Magnetic drive E range Installed powers: kw 15 Bodies materials: PP - E-CTFE ZGE range (ISO 2858) Installed powers: kw 0,55 00 Bodies materials: PP - PVDF - PVC - PE HMW and ZGA range Installed powers: kw 0,75 11 Bodies materials: PP - PVDF - PVC Self priming range Installed powers: kw 0,75 11 Bodies materials: GFRPP - CFFPVDF Lenghts 0 000 mm K range (KM and KMS) Installed powers: kw 0,75 22 Bodies materials: GFRPP - PVDF - PVC Lenghts 2 2000 mm K range (KG and KGS) Installed powers: kw 0,75 7 Bodies materials: GFRPP - PVDF - PVC Lenghts 0 000 mm EQUIPRO range Available motor power: 0, kw Material versions: GFRPP PVDF Lenghts 275 - mm LAGOON range Range: from 0 to.000 lh Filter materials: PP - PVDF Pump materials: GFRPP - CFFE-CTFE Member of AIB associazione industriale bresciana IT - 1 BRESCIA - Via Labirinto, 159 Tel. +9 00 7011 - Fax +9 00 7077 Export dpt. Tel. +9 00 70 Web: www.argal.it - E-mail: export@argal.it It is the policy of ARGAL to always improve its products and the right is reserved to alter specifications at any time without prior notice. No part of this publication may be reproduced in any form or any means. 6