Residential. Commercial 7-22 23-38. Controls 69-75. Multi XRV Plus System 39-68. Technical courses Key to icons 76-79



Similar documents
General Catalogue 2013

york air-conditioning products Residential & VRF News 2015

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Unico Inverter. Unique and efficient.

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

AIR-CONDITIONER SPLIT TYPE

Inverter Air Conditioning for Light Commercial Use

Pioneer in sustainability

FULL DC INVERTER SYSTEMS

LG Electronics AE Company, Commercial Air Conditioning

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

FTXS. Wall Mount Heat Pump or Cooling Only

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

DUCTED AIR CONDITIONING SOLUTIONS

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

ECO-AIR AIR CONDITIONING

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

FBQ. DC Duct Heat Pump or Cooling Only

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

FHQ. Ceiling Suspended Heat Pump or Cooling Only

-~ available. Power consumption during operation is substantially less than that of lower rated

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

innovative comfort solutions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Shaping the future. For room air conditioners of up to 12 kw (Lot 10) Information brochure for specialists, decision-makers and operators

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

An overview of energy efficient products used at reducing energy consumptions in buildings

M Series. Room Air Conditioning

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

LOCAL AIR-CONDITIONERS

FTQ. Daikin Inverter Ducted Heat Pump

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

HP switch LP switch Discharge thermo Comp. Surface thermo

How To Control A Car With A Power Unit

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Daikin Altherma hybrid heat pump. The natural combination

IR410AI. The flexible solution. Simple, one touch control

2015 / 16. price list. Airconditioning systems

2010 Duct-Free Splits Line Card

Cooling kw Heating kw

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

LG Air Conditioning & Energy Solutions Price List

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Air conditioners Heating & Cooling

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Energy efficient room air conditioners best available technology (BAT)

The new Ecodesign regulation for heaters: what does it mean for heat pumps?

Operating Instructions Split System Air Conditioner

AIR CONDITIONING GENERAL CATALOGUE

Appendix - Controllers 179

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

The natural ombination

The Benefits Really Add Up

technology innovation, comfort for your home. The perfect blend of

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Failure code manual. content

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Air Conditioners Technical Data

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

How to choose a heat pump and use it wisely

Portable Air Conditioner

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Air Conditioning for Small and Medium-size Buildings

Daikin Altherma. hybrid heat pump. The natural combination

Split units TH with hermetic compressors

Rotary screw compressors kw 5,5 7, , bar MODULO

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Schedule 3(A) Room Air Conditioners

USER S MANUAL HSC-24A

NEW 3-PIPE ECOi MF2 SERIES

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

Operating Instructions Air Conditioner

All the best brands all under one roof

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

PORTABLE AIR CONDITIONER

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

YOUR CONDITIONS! units carry a 5-year Warranty for the compressor and for all parts of the unit. ) New Technologies

Air Conditioning For Large Buildings

Transcription:

General Catalogue 2014

Air Systems is exclusieve distributor of Hokaido, based in Dubai and present in the Middle East market, Air Systems maintains its competitive edge with a simultaneous focus on our costomers. Hokkaido is a brand that has been able to stand out in the market, offering a quality solution for the different application requirements of installers, retailers, designers and end users. Residential Commercial 7-22 23-38 Multi XRV Plus System 39-68 Controls 69-75 Technical courses Key to icons 76-79

Experience makes technology Energy saving, comfort and respect for the environment have always been the goals of Hokkaido, committed to the development of technological solutions that look to the future. Hokkaido With over 10 years of experience in providing reliable and high-tech products, Hokkaido brand, born in 2000, is a recognized leader in Italy and Europe in the production and marketing of air conditioners for residential, commercial and industrial applications. Our office Hokkaido Italia, born in early 2008, has its headquarters in Bologna at the operational center of Termal Group to which it belongs. Hokkaido Italia is the company dedicated exclusively to the distribution of Hokkaido products on the Italian market. A network of 25 agencies, widely distributed throughout the country is addressed to both wholesalers and installers of traditional heating and sanitary water channel. The goal is to become the leader in its market with the offer of a wide and versatile range of products for the air-conditioning of residential, commercial and industrial environments, characterized by high technology, very high performance and highly competitive price. A reality not only the european In Europe, Hokkaido has been present since 1999, when Termal Group has expressed its sales force at international level too with the direct export of air conditioners in 30 different European and non-european countries. The international network of dealers and distributor partners has developed faster and faster, mainly due to the variety and reliability of services offered. In January 2009, the establishment of Termal International strengthens business development strategy of Hokkaido brand on international markets. The new corporate structure allows to offer more flexible and innovative services, closer to customer needs, with special attention to the logistics organization, that has always been Termal Group s point of excellence: prompt deliveries throughout the EU territory, a vast assortment of spare parts and accessories ordered online and available in 24 hours, technical and training support both on site and at Termal Group s headquarters in Bologna. All this gives customers a great operational and commercial flexibility, and therefore a strong competitiveness for a better management of the various local markets. 2

Being constantly engaged in improving the climate in the world means accepting the committment to use energy in an intelligent way, in order to protect the environment The network The distribution is organized through channels dedicated to specific market segments and is assigned to 3 different commercial companies. It is dedicated exclusively to the distribution of Hokkaido brand products on the Italian market with a network of agencies, distributed throughout the national territory. It is addressed to: wholesalers and installers of traditional heating and sanitary water channel. www.hokkaidoitalia.it AIR SYSTEMS "Your Comfort Is Our Mission" Termal International has partnered with Air Systems as our exclusive distributor to represent Hokkaido Air- Conditioning in the Middle East. The goal is to become the leader in its market with the offer of a wide and versatile range of products for the air-conditioning of residential, commercial and industrial enviroments, characterized by high technology, very high performance and highly competitive price. www.airsystems.ae Termal International is the channel dedicated to the direct export of Hokkaido products towards 30 different European and non-european countries. The international network is made up of dealers and distributor partners and provides quick deliveries throughout the EU territory. www.termalinternational.it 3

ErP Ecodesign Directive Eco-design of energy-related products (ErP: Energy related Products) Over 80% of the environmental impact of a product is determined at the design stage. Ecodesign implies taking into account all the environmental impacts of a product from the earliest stages of design. The purpose of this policy is therefore to promote eco-design of energy-using products and reduce consumptions and CO2 emissions. All this contributes, through incremental development, to meet the strategic European plan 20 20 20 which involves the following within the year 2020: - 20% reduction of primary energy consumption; - 20% reduction of CO2 emissions; - 20% use of renewable energy. On January 1st, 2013 the new minimum energy efficiency values came into force, to be respected in the production of new air-conditioning appliances. This is required by the European Directive ErP (Energy Related Products) which introduces: - new methods for calculating energy efficiency, including the seasonal efficiency parameter SCOP in Heating mode and SEER in Cooling mode; - the obligation for the manufacturers to comply with these new minimum levels of energy efficiency, together with the maximum set values of sound power referred to all new products on the market. With these new standards, manufacturers are encouraged to seek and adopt new design methods. The most evident impact will be exactly on the use of heat pumps as primary heating of residential environments. Advantages For the consumer The European Directive ERP: - aims to increase the minimum efficiency of air conditioners, rearranging at the same time the field of air conditioning and establishing the prohibition of import and production of the products which are no more efficient; - ensures that the differences between the regulations of the various European countries do not become obstacles to the intra-european market; - requires all Manufacturers to provide more details and information to the Consumer, thus allowing to make more conscious choices when purchasing. For the environment The Directive requires the Manufacturers to promote the development of more efficient appliances, which leads to a reduction in the consumption of valuable natural resources, minimizing the environmental impact. The increased quality and quantity of information increases transparency on energy consumption of air conditioning.

Energy Label The format In agreement with the Ecodesign Directive, the Regulation 626/2011 is born for the new energy label based on the actual seasonal performance of air conditioners. Therefore, since January 1st, 2013 the new energy label came into force. In all product categories for which it had been already planned, the energy label has kept its format and simple design, i.e. the basic elements that make it recognizable: - division into classes; - 7 energy efficiency classes; - chromatic scale: the bright green colour indicates the high energy efficiency product; red colour indicates the low energy efficiency product. The very clear representation of energy efficiency in Heating mode related to the seasonal COP has been introduced. COOLING - Energy Class - kw - Energy effi ciency seasonal - Annual kw HEATING (obligatory) Temperate regions - Energy Class - kw - Seasonal Coeffi cient of Performance - Annual kw Noise level indoor unit Noise level outdoor unit HEATING (optional) Cold regions - Energy Class - kw - Seasonal Coeffi cient of Performance - Annual kw HEATING (optional) Warm regions - Energy Class - kw - Seasonal Coeffi cient of Performance - Annual kw Moreover, additional elements have been introduced, to allow the manufacturers and consequently the retailers to highlight progress and technological excellence. The new European legislation on energy label introduces new energy classes above the class A (A+, A++, A+++): starting from 2013 up to 2019, these classes will gradually indicate more clearly the consumption of the equipments by highlighting the products differences both in quality and performance. Since January 1st, 2013, the fixed Air conditioners of new production and / or new import will have to meet minimum energy efficiency requirements not less than Class D in Cooling mode and Class A in Heating mode - which will be rising in future years. Such labelling shows uniformity in all 27 EU member states and linguistic neutrality, since the texts have been replaced by pictograms that inform at a glance the consumers about the characteristics and performance of the appliances. The usual indication of sound pressure (amplitude of pressure wave, or sound wave influenced by the environment) is replaced by the parameter of sound power (energy supplied per time unit, independent of the environment in which the sound is produced), the value of which is higher than that of the sound pressure used in the previous legislation. The promotional and advertising material concerning the product must necessarily bear the reference to the energy efficiency class of the appliance. The rule, in force from January 1st, 2013 in all the countries of the European Union, cannot be applied to the products introduced on the European market before that date. 5

6

Residential MONOSPLIT Performance Line on/off cooling only 10 Performance Line DC Inverter 12 MULTISPLIT Multi Performance DC Inverter cooling only 14 Multi Liberty DC Inverter 18 7

Monosplit Range 2014 PERFORMANCE LINE ON-OFF Cooling only 2,60 kw 3,50 kw 5,10 kw 6,40 kw Wall HKEQ F PERFORMANCE LINE DC INVERTER Wall HKEQ X Performance and consumption are based on the following test conditions: heating E.T. 7 C DB, 6 C WB - I.T. 20 C DB - cooling E.T. 35 C DB, 24 C WB - I.T. 27 C DB, 19 C WB (ISO T1). 8

Multisplit Range 2014 Indoor units 2,00 kw MULTI PERFORMANCE LINE DC INVERTER Cooling only 2,60 kw 3,50 kw 5,30 kw Outdoor units DUAL Wall HKETM Q MULTI LIBERTY DC INVERTER Wall HKEU X DUAL - TRIPLE HCKTM 01 Q2 4.00 kw HCKU 08 X2 4.10 kw HCKU 538 X2 5.30 kw Cassette 60x60 HTFU X TRIPLE - POKER HCKU 608 X3 6.00 kw HCKU 808 X3 8.00 kw Console HFIU X Duct medium static pressure HUCU X POKER - PENTA HCKU 818 X 8.10 kw HCKU 1068 X 10.50 kw HCKU 1068 X5 10.50 kw Indoor units HKEU 209 X HKEU 269 X HKEU 359 X HKEU 539 X HTFU 208 X HTFU 268 X HTFU 358 X HTFU 538 X HFIU 208 X HFIU 268 X HFIU 358 X HFIU 538 X HUCU 208 X HUCU 268 X HUCU 358 X HUCU 538 X Multi Liberty outdoor units connectable units HCKU 08 X2 HCKU 538 X2 HCKU 608 X3 HCKU 808 X3 HCKU 818 X HCKU 1068 X HCKU 1068 X5 9

MONOSPLIT PERFORMANCE LINE ON-OFF Wall Cooling only HKEQ 261~351F Available in 2 different power levels: 2.70~3.50 kw. Intelligent control of the internal fan during thermostatic pauses. Thermostat operated from pc. Timer ON or Timer OFF. Autorestart in event of blackout. SLEEP Function (energy saving). LED Display. 10

MONOSPLIT PERFORMANCE LINE ON-OFF dry HKEQ F Model HKEQ 261 F HKEQ 351 F HCNQ 261 F HCNQ 351 F Type On-Off Controller IR Wireless Capacity (T=+35 C) Cooling W 2700 3500 Power Input (T=+35 C) Cooling W 770 990 Annual Consumption Cooling kwh/a 261 340 Energy efficiency class seasonal Cooling 626/20111 D D Energy efficiency seasonal index Cooling SEER2 3.60 3.60 Coefficient of Energy Efficiency Rated Cooling EER3 3.51 3.54 Design load (Pdesignc) Cooling kw 2.70 3.50 Temperature range Cooling C 0 C (at indoor temperature over 16 C) Removed wet Lt/h 1.00 1.50 Noise level - I.U. Hi-Mi-Lo db(a) 38-34-26 40-34-26 Sound power level - I.U. db(a) 50 52 Noise level - O.U. db(a) 48 50 Sound power level - O.U. db(a) 63 65 Electrical data Power supply 220-240V~/50Hz/1P to I.U. Power cable V 198~264 198~264 Power cable Type 2+T x 1.5 mm 2 2+T x 2.5 mm 2 Current consumption Cooling A 3.50 (1.30~5.00) 4.50 (1.30~6.10) Refrigerant circuit Refrigerant(GWP)4 R410A (1975) R410A (1975) Refrigerant Charge kg 0.91 1.00 Max splitting distance m 15 Max splitting I.U. /O.U. m 5/5 MAX Splitting with Refrigerant Precharge m 5 Additional Refrigerant Charge gr/m 20 Compressor Type Rotary Model 44A233AJ-FEKC 48A313PM-55KF Fan Max indoor air flow m3/h 530 700 Power Input W 18 18 Max outdoor air flow m3/h 2000 2000 Power Input W 30 30 Connections Cable connection between I.U. and O.U. Type 2+T x 1.5 mm 2 2+T x 1.5 mm 2 Refrigerant piping Gas mm/inch. ø9.52 (3/8") ø9.52 (3/8") Liquid mm/inch. ø6.35(1/4") ø6.35(1/4") Specifications Dimension (W x H x D) I.U. mm 800x240x180 943x280x220 O.U. mm 760x552x256 760x552x256 Net I.U. kg 8 11 O.U. kg 32 36 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 11

MONOSPLIT PERFORMANCE LINE DC INVERTER Wall HKEQ 262~352 X HKEQ 512~642 X Available in different power levels: 2.60~6.0 kw. SEER 6.1 e SCOP 3.9 (6.0 kw model). DC-Inverter power control. Intelligent control of the internal fan during thermostatic pauses. Defrosting operated from pc. Thermostat operated from pc. imer ON or Timer OFF. Autorestart in event of blackout. SLEEP Function (energy saving). LED Display 12

MONOSPLIT PERFORMANCE LINE DC INVERTER dry HKEQ X Model HKEQ 262 X HKEQ 352 X HKEQ 512 X HKEQ 62 X HCNQ 262 X HCNQ 352 X HCNQ 512 X HCNQ 62 X Type Heat pump DC-Inverter Controller IR Wireless Capacity (T=+35 C) Cooling W 2600 (1000~3100) 3500 (1050~3700) 5100 (1800~5700) 6400 (1500~7500) Power Input (T=+35 C) Cooling W 800 (290~1100) 1080 (290~1330) 1660 (500~2100) 2150 (350~2800) Annual Consumption Cooling kwh/a 149 196 293 366 Energy efficiency class seasonal Cooling 626/20111 A++ A++ A++ A++ Energy efficiency seasonal index Cooling SEER2 6.1 6.1 6.1 6.1 Coefficient of Energy Efficiency Rated Cooling EER3 3.23 3.23 3.07 2.98 Design load (Pdesignc) Heating kw 2.6 3.5 5,1 6.4 Capacity (T=+7 C) Heating W 2600 (1000~3800) 3500 (1050~4500) 5100 (1800~6500) 6600 (1500~8000) Power Input (T=+7 C) Heating W 800 (290~1100) 940 (290~1700) 1630 (500~2350) 1850 (300~3200) Annual Consumption Heating kwh/a 954 1276 1860 2159 Energy efficiency class (average season) Heating 626/20111 A A A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 3.8 3.9 Coefficient of Energy Efficiency Rated Heating COP3 3.71 3.71 3.13 3.57 Design load (Pdesignh) @-10 C Heating kw 2.60 3.50 5.10 6.00 Temperature range Cooling C 0 C (at indoor temperature over 16 C) T operational limit (Tol) Heating C -15 C Removed wet Lt/h 0.8 1.0 1,5 1.6 Noise level - I.U. Hi-Mi-Lo db(a) 38-34-26 38-34-26 42-36-28 48-44-40 Sound power level - I.U. Hi-Mi-Lo db(a) 50-46-38 50-46-38 54-48-40 60-56-52 Noise level - O.U. Hi-Mi-Lo db(a) 48-44-42 50-46-44 53-46-44 56-54-52 Sound power level - O.U. Hi-Mi-Lo db(a) 60-56-52 62-58-54 65-58-54 68-66-62 Electrical data Power supply 220-240V~/50Hz/1P to I.U. Power cable V 165~265 165~265 165~265 165~265 Power cable Type 3+T x 1,5 mm 2 3+T x 2,5 mm 2 Current consumption Cooling A 3.60 (1.30~5.00) 4.90 (1,30~6.10) 7,60 (2.30~9.60) 9,80 (1.70~13.50) Current consumption Heating A 3.20 (1.30~6.40) 4.30 (1,30~7.80) 7,50 (2.30~10.80) 8,50 (1.50~15.50) Refrigerant circuit Refrigerant (GWP)4 R410A (1975) R410A (1975) R410A (1975) R410A (1975) Refrigerant Charge kg 0.80 1.00 1.27 2.05 Max splitting distance m 15 Max splitting I.U. /O.U. m 5/5 MAX Splitting with Refrigerant Precharge m 5 Additional Refrigerant Charge gr/m 20 30 Type Rotary Compressor Model 43A23EEL&PJKD 43A26DEL-PJKE 45A33LPX-PEKG ATL165UDPC9AU Frequency range 20~120 20~120 30~120 20~120 Fan Max indoor air flow m 3 /h 650 650 850 1200 Power Input W 18 18 23 50 Max outdoor air flow m 3 /h 2100 2000 2400 3200 Power Input W 33 33 68 115 Connections Cable connection between I.U. and O.U. Type 3+T x 1.5 mm 2 3+T x 2.5 mm 2 3+T x 2.5 mm 2 Refrigerant piping Gas mm/inch. ø9.52 (3/8 ) ø9.52 (3/8 ) ø12.70 (1/2 ) ø15.88 (5/8 ) Liquid mm/inch. ø6.35 (1/4 ) ø6.35 (1/4 ) ø6.35 (1/4 ) ø6.35 (1/4 ) Specifications Dimension (W x H x D) I.U. mm 837x280x185 837x280x185 943x280x220 1088x313x202 O.U. mm 760x551x256 760x551x256 780x605x290 900x650x315 Net I.U. kg 10 10 11 14 O.U. kg 30 32 41 50 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 13

MULTISPLIT PERFORMANCE DC INVERTER Wall Cooling only HKETM 201~351 Q Available in 3 different power levels: 2.00~3.50 kw. Intelligent control of the internal fan during thermostatic pauses. Thermostat operated from pc. Timer ON or Timer OFF. Autorestart in event of blackout. SLEEP Function (energy saving). LED Display. HCKTM 401 Q2 1

MULTISPLIT PERFORMANCE DC INVERTER Outdoor units Sine Wave Inverter Technology: 180 HCKTM 401 Q2 Model HCKTM 01 Q2 Type DC Inverter (Cooling only) Indoor unit connectable n 2 Capacity (T=35 C) Cooling kw 4.10 (1.05~4.69) Power Input (T=+35 C) Cooling kw 1.270 (0.28~1.65) Annual Consumption Cooling kwh/a 281 Energy Efficiency Class Seasonal Cooling 626/20111 A Energy Efficiency Class Seasonal Index Cooling SEER2 5.1 Coefficient of Energy Efficiency Rated Cooling EER3 3.23 Design load (Pdesignc) Cooling kw 4.10 Power supply Ph-V-Hz 1-220~230V-50HZ I.U. ~ O.U. O.U. & I.U. (individually) Input Rated Current A 5,7 Wiring cables i.u./o.u. (without ground) n 2 (internal and external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. 2 x ø6.35 (1/4 ) - 2 x ø9.52 (3/8 ) TOTAL Piping Length m 24 MAX length of one refrigerant line m 15 Max splitting level difference O.U./I.U. - I.U./ O.U. m 5/5 Refrigerant Precharge kg 1.5 MAX Splitting with Refrigerant Precharge (each I.U.) m 5 Additional Refrigerant Charge Liquid Pipe ø1/4" g/m 15 Temperature range cooling C 0 C ~ +48 C Indoor unit specifications Outdoor Unit Dimension (W x H x D) mm 820x605x300 Net kg 44 Max noise level 1 m db(a) 60 Max power sound level db(a) 65 Max air flow m 3 /h 2800 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 15

MULTISPLIT PERFORMANCE DC INVERTER Indoor units Wall HKETM 201~351 Q 3 power levels: 2.05~3.50. Low acoustic impact: only 29 db(a) for model from 2.05 kw. SLEEP Function. Intelligent control of the internal fan. dry Model HKETM 201 Q HKETM 261 Q HKETM 351 Q Type DC Inverter (Cooling only) DC Inverter (Cooling only) DC Inverter (Cooling only) Capacity Cooling kw 2.05 2.64 3.50 Electrical data Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U.~O.U. O.U. O.U. O.U. Wiring cables i.u./o.u. (without ground) n 2 (internal - external side terminal board)2 (internal - external side terminal board)2 (internal - external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) Specifications Indoor Unit Dimension (WxHxD) mm 770x240x180 770x240x180 770x240x180 Net kg 8 8 8 Noise level 1 m Hi/Mi/Lo db(a) 40-36-29 41-38-31 43-40-31 Sound power level db(a) 48 48 48 Air flow Hi/Mi/Lo m 3 /h 450-400-350 470-420-380 500-450-400 Drain hose diameter mm 16 16 16 Remote Controller (st. equipment) type IR Wireless IR Wireless IR Wireless Options Wired control - Best combination 16

17

MULTISPLIT MULTI LIBERTY DC INVERTER Multi Liberty Residential Range. Wide range of indoor units, from wall to cassette 60x60, console and ducted. Possibility to connect up to 5 indoor units. HKEU X HKEU 209~539 X HTFU X HTFU 208~538 X HFIU X HFIU 208~538 X HUCU X HUCU 208~538 X 18

MULTISPLIT MULTI LIBERTY DC INVERTER Outdoor units Sine Wave Inverter Technology: 180 HCKU 408 X2 DUAL HCKU 538 X2 DUAL HCKU 608 X3 TRIAL HCKU 808 X3 TRIAL HCKU 818 X4 POKER HCKU 1068 X4 POKER HCKU 1068 X5 PENTA Model HCKU 08 X2 HCKU 538 X2 HCKU 608 X3 HCKU 808 X3 HCKU 818 X HCKU 1068 X HCKU 1068 X5 Type DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter Indoor unit connectable n 2 2 3 3 5 Capacity (T=35 C) Cooling kw 4.10 (1.54~5.50) 5.30 (1.40~6.60) 6.16 (1.56~8.93) 8.00 (1.38~9.80) 8.21 (1.38~11.09) 10.55 (1.27~13.80) 10.50 (1.30~17.23) Power Input (T=+35 C) Cooling kw 1.200 (0.61~1.83) 1.570 (0.41~2.09) 1.900 (0.53~3.03) 2.410 (0.48~3.06) 2.470 (0.58~3.75) 3.250 (0.55~4.31) 3.280 (0.55~5.82) Annual Consumption Cooling kwh/a 282 320 386 477 470 707 656 Energy Efficiency Class Seasonal Cooling 626/2011 1 A A+ A+ A+ A++ A A+ Energy Efficiency Class Seasonal Index Cooling SEER 2 5.1 5.8 5.8 5.8 6.1 5.2 5.6 Coefficient of Energy Efficiency Rated Cooling EER 3 3.42 3.38 3.24 3.32 3.32 3.25 3.20 Design load (Pdesignc) Cooling kw 4.10 5.30 6.40 7.90 8.20 10.50 10.50 Capacity (T=+7 C) Heating kw 4.60 (1.59~5.70) 5.80 (1.30~6.40) 6.74 (1.67~9.32) 8.85 (1.47~10.50) 9.10 (1.59~12.30) 11.70 (1.59~14.40) 12.30 (1.59~17.74) Power Input (T=+7 C) Heating kw 1.080 (0.45~1.75) 1.462 (0.37~1.80) 1.750 (0.49~2.80) 2.350 (0.46~2.75) 2.440 (0.47~3.71) 3.100 (0.61~4.23) 3.400 (0.61~5.23) Annual Consumption Heating kwh/a 1540 2063 2247 3021 2984 3832 3868 Energy Efficiency Class Seasonal (average season) Heating 626/2011 1 A+ A A A A A A Energy Efficiency Class Seasonal Index Heating SCOP 2 4.0 3.8 3.8 3.8 3.8 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP 3 4.26 3.97 3.85 3.77 3.73 3.77 3.62 Design load (Pdesignh) Heating kw 4.40 5.60 6.10 8.20 8.10 10.40 10.50 T operational limit (Tol) Heating C -15-15 -15-15 -15-15 -15 Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U. ~ O.U. O.U. O.U. O.U. O.U. O.U. O.U. O.U. Input Rated Current (Cooling - Heating) A 5.70-6.50 7.00-7.40 8.30-7.60 10.80-10.30 11.20-11.10 14.30-14.50 16.60-15.30 Wiring cables i.u./o.u. (without ground) n Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. 3 (internal and external side terminal board) 2 x ø6.35 (1/4 ) - 2 x ø9.52 (3/8 ) 3 (internal and external side terminal board) 2 x ø6.35 (1/4 ) - 2 x ø9.52 (3/8 ) 3 (internal and external side terminal board) 3 x ø6.35 (1/4 ) - 3 x ø9.52 (3/8 ) 3 (internal and external side terminal board) 3 x ø6.35 (1/4 ) - 3 x ø9.52 (3/8 ) 3 (internal and external side terminal board) 4 x ø6.35 (1/4 ) - 4 x ø9.52 (3/8 ) 3 (internal and external 3 (internal and external side terminal board) side terminal board) 4 x ø6.35 (1/4 ) - 4 x ø9.52 (3/8 ) 5 x ø6.35 (1/4 ) - 5 x ø9.52 (3/8 ) Refrigerating pipes adapter 9.53 (3/8") 12.7 (1/2") n. 1 2 2 2 3 4 5 TOTAL Piping Length m 30 30 45 45 60 60 75 MAX length of one refrigerant line m 20 20 25 25 30 30 30 Max splitting level difference O.U./I.U. - I.U./ O.U. m 10/15 10/15 10/15 10/15 10/15 10/15 10/15 Refrigerant Precharge kg 1.55 1.90 2.10 2.40 2.40 2.70 3.00 MAX Splitting with Refrigerant Precharge (each I.U.) m 5 5 5 5 5 5 5 Additional Refrigerant Charge Liquid Pipe ø1/4" g/m 15 15 15 15 15 15 15 Temperature range cooling C -15 C ~ +50 C Temperature range heating C -15 C ~ +24 C Specifications Outdoor Unit Dimension (WxHxD) mm 845x700x320 845x700x320 845x700x320 900x860x315 900x860x315 990x965x345 990x965x345 Net kg 46 48 50 62 65 78 80 Max noise level 1 m db(a) 60 62 58 62 61 65 65 Max power sound level db(a) 63 63 64 67 70 70 68 Max air flow m 3 /h 2500 2500 2700 3500 3800 5500 5500 Energy effi ciency values refer to the following combinations: HCKU 408 X2 + 2 x HTFU 208 X - HCKU 538 X2 + 2 x HTFU 268 X - HCKU 608 X3 + 3 x HTFU 208 X HCKU 808 X3 + 3 x HTFU 268 X - HCKU 818 X4 + 4 x HTFU 208 X - HCKU 1068 X4 + 4 x HTFU 268 X HCKU 1068 X5 + 5 x HTFU 208 X. 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 19

MULTISPLIT MULTI LIBERTY DC INVERTER Indoor units Wall 4 power levels: 2.05~4.98 kw. Ultra-compact design: only 188 mm in depth for the 2.05~3.50 kw models and only 205 mm for the 4.98 kw model. HKEQ X Model HKEU 209 X HKEU 269 X HKEU 359 X HKEU 539 X Type DC Inverter DC Inverter DC Inverter DC Inverter Capacity Cooling kw 2.05 2.64 3.50 4.98 Heating kw 2.35 2.93 3.80 5.28 Electrical data Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U.~O.U. O.U. O.U. O.U. O.U. Wiring cables i.u./o.u. (without ground) n 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.70 (1/2 ) Specifications Indoor Unit Dimension (WxHxD) mm 800x275x188 800x275x188 800x275x188 940x275x205 Net kg 7.3 7.3 7.3 9 Noise level 1 m Hi-Mi-Lo db(a) 40-36-29 41-38-31 43-40-31 41-33-31 Sound power level db(a) 58 58 57 55 Air flow Hi-Mi-Lo m3/h 620-540-440 620-540-440 630-550-430 730-480-400 Drain hose diameter mm 25 25 25 25 Remote Controller (st. equipment) type IR Wireless IR Wireless IR Wireless IR Wireless Options Wired control - Cassette 60x60 - Round flow HTFU X 4 power levels: 2.00~5.00 kw. Pre-set for external air intake connection; condensate drain pump; electrical box inside the body machine. Panel with 360 air diffusion; wide swinging range of flaps, up to 40. Easy installation and maintenance. Model HTFU 208 X HTFU 268 X HTFU 358 X HTFU 538 X Type DC Inverter DC Inverter DC Inverter DC Inverter Capacity Cooling kw 2.00 2.60 3.50 5.00 Heating kw 2.35 2.90 3.80 5.20 Electrical data Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U.~O.U. O.U. O.U. O.U. O.U. Wiring cables i.u./o.u. (without ground) n 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.70 (1/2 ) Specifications Indoor Unit Dimension (WxHxD) mm 570x260x570 570x260x570 570x260x570 570x260x570 Net kg 17 17 17 18 Noise level 1 m Hi-Mi-Lo db(a) 42-38-34 42-38-34 42-38-34 44-39-35 Sound power level db(a) 53 53 54 57 Air flow Hi-Mi-Lo m 3 /h 580-510-400 580-510-400 580-550-420 750-700-560 Drain hose diameter mm 20 20 20 20 Remote Controller (st. equipment) type IR Wireless IR Wireless IR Wireless IR Wireless Panel TFP 352 IHR TFP 352 IHR TFP 352 IHR TFP 352 IHR Panel Dimension (WxHxD) mm 647x50x647 647x50x647 647x50x647 647x50x647 Net kg 2.5 2.5 2.5 2.5 Options Wired control - low noise easy installation timer 24h dry 20

MULTISPLIT MULTI LIBERTY DC INVERTER Indoor units Console - Primary Heating HFIU X 4 capacities: 2.05~4.98 kw. Primary heating. Only 210 mm depth. Double mode of air distribution. Anti-formaldehyde filter. Model HFIU 208 X HFIU 268 X HFIU 358 X HFIU 538 X Type DC Inverter DC Inverter DC Inverter DC Inverter Capacity Cooling kw 2.05 2.64 3.50 4.98 Heating kw 2.35 2.93 3.80 5.28 Electrical data Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U.~O.U. O.U. O.U. O.U. O.U. Wiring cables i.u./o.u. (without ground) n 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.70 (1/2 ) Specifications Indoor Unit Dimension (WxHxD) mm 700x600x210 700x600x210 700x600x210 700x600x210 Net kg 13.6 13.6 15 15 Noise level 1 m Hi-Mi-Lo db(a) 37-32-28 37-32-28 40-36-31 45-41-36 Sound power level db(a) 54 55 57 58 Air flow Hi-Mi-Lo m 3 /h 680-540-440 680-540-440 650-550-450 740-560-460 Drain hose diameter mm 25 25 25 25 Remote Controller (st. equipment) type IR Wireless IR Wireless IR Wireless IR Wireless Options Wired control - HUCU X Duct medium static pressure 4 power levels: 2.05~5.00 kw. External air intake pre-set and air intake from bottom or rear. Available static pressure: 40 Pa (2.05~3.50 kw); 70 Pa (5.00 kw). Condensate drain pump included; movable electrical box. Model HUCU 208 X HUCU 268 X HUCU 358 X HUCU 538 X Type DC Inverter DC Inverter DC Inverter DC Inverter Capacity Cooling kw 2.05 2.60 3.50 5.00 Heating kw 2.35 2.90 3.80 5.20 Electrical data Power supply Ph-V-Hz 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ 1-220~230V-50HZ I.U.~O.U. O.U. O.U. O.U. O.U. Wiring cables i.u./o.u. (without ground) n 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) 3 (internal - external side terminal board) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.70 (1/2 ) Specifications Indoor Unit Dimension (WxHxD) mm 700x210x635 700x210x635 700x210x635 920x210x635 Net kg 20 20 20 23 Noise level 1 m Hi-Mi-Lo db(a) 42-37-35 42-37-35 42-39-37 45-37-35 Sound power level db(a) 34 34 34 37 Air flow Hi-Mi-Lo m 3 /h 800-690-520 800-690-520 1000-850-600 1150-900-600 Drain hose diameter Pa 40 40 40 70 Remote Controller (st. equipment) mm 16 16 16 16 Controllo remoto (in dotazione) type IR Wireless IR Wireless IR Wireless IR Wireless Options Wired control YES low noise easy installation timer 24h dry 21

MULTISPLIT MULTI LIBERTY DC INVERTER Best combinations 22

Commercial LIGHT COMMERCIAL FULL DC INVERTER Compact Cassette 60x60 25 SLIM Cassette 84x84 26 Console 27 Ceiling/floor 28 Duct Medium Static Pressure 29 COMMERCIAL SLIM Cassette 84x84 31 Ceiling/floor 32 Duct Medium Static Pressure 33 Indoor units 34 TWIN combination 36 23

Light Commercial Range 2014 3,50 kw 5,30 kw 7,10 kw 10,80 kw FULL DC INVERTER Compact Cassette 60x60 HTFI X HCKI 359 X 1Ph SLIM Cassette 84x84 HTBI X HCKI 539 X 1Ph Console HFII X HCKI 719 X 1Ph Ceiling/floor HSFI X Duct Medium Static Pressure HUCI X HCSI 1089 X 3Ph New range Light Commercial Full DC Inverter, the ideal solution for extended surfaces. 5 different types of indoor units, 4 capacities, 13 models in all. New Outdoor Units Series 9 FULL DC INVERTER New compressor DC INVERTER. Ultra-compact design. Low noise level. High efficiency and energy saving. Cooling operation with outdoor temperature down to -15 C. Heating operation with outdoor temperature down to -15 C. PFC control (Power Factor Correction) optimizes the power supply voltage. 25 steps to control the compressor frequency. Outdoor unit s DC Inverter fan with 5 speeds. All the outdoor units are equipped with: Sine Wave Inverter Technology: 180 Signifi cant reduction of noise level and vibrations. Considerable increase in effi ciency at low frequencies. Increase in frequency range from 10Hz to 130 Hz. Performance and consumption are based on the following test conditions: heating E.T. 7 C DB, 6 C WB - I.T. 20 C DB - cooling E.T. 35 C DB, 24 C WB - I.T. 27 C DB, 19 C WB (ISO T1). 2

LIGHT COMMERCIAL FULL DC INVERTER Compact Cassette 60x60 fresh air low noise easy installation timer 24h dry HTFI X Model HTFI 359 X HTFI 539 X HCKI 359 X HCKI 539 X Type FULL DC-Inverter FULL DC-Inverter Capacity (T=+35 C) Cooling W 3517 (1400~4000) 5300 (1578~6048) Power Input (T=+35 C) Cooling W 1090 (300~2020) 1640 (300~2020) Annual Consumption Cooling kwh/a 219 313 Energy efficiency class seasonal Cooling 626/20111 A+ A+ Energy efficiency seasonal index Cooling SEER2 5.6 5.6 Coefficient of Energy Efficiency Rated Cooling EER3 3.23 3.23 Design load (Pdesignc) Cooling kw 3.50 5.00 Capacity (T=+7 C) Heating W 4103 (1400~4750) 5862 (1607~6661) Power Input (T=+7 C) Heating W 1070 (290~2010) 1580 (290~2010) Annual Consumption Heating kwh/a 1289 1953 Energy efficiency class (average season) Heating 626/20111 A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP3 3.83 3.71 Design load (Pdesignh) Heating kw 3.50 5.30 T operational limit (Tol) Heating C -15-15 Power supply Ph-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ I.U.~O.U. I.U. + O.U. I.U. + O.U. Current consumption (MAX) A 9.5 10 Wiring cables i.u./o.u. (without ground) n STP(2 plus + ordinary one) STP(2 plus + ordinary one) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.7 (1/2 ) Max splitting distance indoor/outdoor m 20 30 Max splitting level difference I.U./O.U. m 10/5 20/9 Refrigerant (GWP)4 R410A (1975) R410A (1975) Refrigerant Precharge kg 1.10 1.80 MAX Splitting with Refrigerant Precharge m 5 5 Additional Refrigerant Charge g/m 15 15 Temperature range Cooling C -15 C ~ +50 C -15 C ~ +50 C Temperature range Heating C -15 C ~ +24 C -15 C ~ +24 C Indoor Unit specifications Indoor Unit Dimension (WxHxD) mm 570x260x570 570x260x570 Net kg 16 18 Noise level - I.U. Hi-Mi-Lo db(a) 47-38-36 47-38-36 Sound power level - I.U. db(a) 54 59 Air flow Hi-Mi-Lo m3/h 800-710-560 800-710-560 Drain hose diameter mm 25 25 Remote Controller (st. equipment) Type IR Wireless IR Wireless Outdoor Unit Specifications Outdoor Unit Dimension (WxHxD) mm 760x590x285 845x700x320 Net kg 35.5 46 Noise level - O.U. db(a) 58 60 Sound power level - O.U. db(a) 61 65 Max air flow m3/h 2200 2500 Accessories Panel TBP 352 IHR TBP 352 IHR Panel Dimension (WxHxD) mm 647x50x467 647x50x467 Net kg 2.5 2.5 Options Wired control DTW 3 IHXR, DTW IHXR Simply, DTWS 3 IHXR Compact Centralized control DTC IHXR Touch, DTC IHXR, DTCWT IHXR Weekly timer DTWT 1 IHXR, DTWT IHXR 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 25

LIGHT COMMERCIAL FULL DC INVERTER SLIM Cassette 84x84 low noise easy installation timer 24h dry easy clean panel HTBI X Model HTBI 719 X HTBI 1089 X HCKI 719 X HCSI 1089 X Type FULL DC-Inverter FULL DC-Inverter Capacity (T=+35 C) Cooling W 7034 (1899~7830) 10800 (3068~11978) Power Input (T=+35 C) Cooling W 2100 (380~2620) 3290 (600~4250) Annual Consumption Cooling kwh/a 393 707 Energy efficiency class seasonal Cooling 626/20111 A++ A Energy efficiency seasonal index Cooling SEER2 6.5 5.2 Coefficient of Energy Efficiency Rated Cooling EER3 3.35 3.28 Design load (Pdesignc) Cooling kw 7.30 10.50 Capacity (T=+7 C) Heating W 7620 (1987~8473) 12100 (3155~12504) Power Input (T=+7 C) Heating W 2030 (370~2630) 3210 (600~4250) Annual Consumption Heating kwh/a 2947 3795 Energy efficiency class (average season) Heating 626/20111 A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP3 3.75 3.77 Design load (Pdesignh) Heating kw 8.00 10.30 T operational limit (Tol) Heating C -15-15 Power supply Ph-V-Hz 1-220~240V-50HZ 3-380~400V-50HZ I.U.~O.U. I.U. + O.U. I.U. + O.U. Current consumption (MAX) A 13 11 Wiring cables i.u./o.u. (without ground) n STP(2 plus + ordinary one) STP(2 plus + ordinary one) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø9.52 (3/8 ) - ø15.88 (5/8 ) ø9.52 (3/8 ) - ø15.88 (5/8 ) Max splitting distance indoor/outdoor m 50 65 Max splitting level difference I.U./O.U. m 25/9 30/12 Refrigerant (GWP)4 R410A (1975) R410A (1975) Refrigerant Precharge kg 2.20 3.00 MAX Splitting with Refrigerant Precharge m 5 5 Additional Refrigerant Charge g/m 30 30 Temperature range Cooling C -15 C ~ +50 C -15 C ~ +50 C Temperature range Heating C -15 C ~ +24 C -15 C ~ +24 C Indoor Unit specifications Indoor Unit Dimension (WxHxD) mm 840x245x840 840x245x840 Net kg 24 26.5 Noise level - I.U. Hi-Mi-Lo db(a) 50-45-41 52-49-47 Sound power level - I.U. db(a) 62 64 Air flow Hi-Mi-Lo m3/h 1580-1200-1000 1850-1600-1400 Drain hose diameter mm 32 32 Remote Controller (st. equipment) Type IR Wireless IR Wireless Outdoor Unit Specifications Outdoor Unit Dimension (WxHxD) mm 900x860x315 990x965x345 Net kg 59 77 Noise level - O.U. db(a) 60 63 Sound power level - O.U. db(a) 69 70 Max air flow m3/h 3500 5500 Accessories Panel TBP 716 X TBP 716 X Panel Dimension (WxHxD) mm 950x55x950 950x55x950 Net kg 5 5 Options LIFT panel TBP-LF 716 X TBP-LF 716 X Wired control DTW 3 IHXR, DTW IHXR Simply, DTWS 3 IHXR Compact Wired control (with Lift Panel) DTW-IHXR Touch Centralized control DTC IHXR Touch, DTC IHXR, DTCWT IHXR Weekly timer DTWT 1 IHXR, DTWT IHXR 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 26

LIGHT COMMERCIAL FULL DC INVERTER Console low noise easy installation dry HFII X Model HFII 359 X HFII 539 X HCKI 359 X HCKI 539 X Type FULL DC-Inverter FULL DC-Inverter Capacity (T=+35 C) Cooling W 3517 (1400~4000) 4700 (1578~6048) Power Input (T=+35 C) Cooling W 1090 (300~2020) 1450 (300~2020) Annual Consumption Cooling kwh/a 203 294 Energy efficiency class seasonal Cooling 626/20111 A++ A+ Energy efficiency seasonal index Cooling SEER2 6.2 5.6 Coefficient of Energy Efficiency Rated Cooling EER3 3.23 3.24 Design load (Pdesignc) Cooling kw 3.60 4.70 Capacity (T=+7 C) Heating W 4103 (1400~4750) 5275 (1607~6661) Power Input (T=+7 C) Heating W 1100 (290~2010) 1420 (290~2010) Annual Consumption Heating kwh/a 1289 1879 Energy efficiency class (average season) Heating 626/20111 A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP3 3.73 3.72 Design load (Pdesignh) Heating kw 3.50 5.10 T operational limit (Tol) Heating C -15-15 Power supply Ph-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ I.U.~O.U. I.U. + O.U. I.U. + O.U. Current consumption (MAX) A 9.5 10 Wiring cables i.u./o.u. (without ground) n STP(2 plus + ordinary one) STP(2 plus + ordinary one) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 ) ø6.35 (1/4 ) - ø12.7 (1/2 ) Max splitting distance indoor/outdoor m 20 30 Max splitting level difference I.U./O.U. m 10/5 20/9 Refrigerant (GWP)4 R410A (1975) R410A (1975) Refrigerant Precharge kg 1.10 1.80 MAX Splitting with Refrigerant Precharge m 5 5 Additional Refrigerant Charge g/m 15 15 Temperature range Cooling C -15 C ~ +50 C -15 C ~ +50 C Temperature range Heating C -15 C ~ +24 C -15 C ~ +24 C Indoor Unit specifications Indoor Unit Dimension (WxHxD) mm 700x600x210 700x600x210 Net kg 15 15 Noise level - I.U. Hi-Mi-Lo db(a) 45-38-36 46-38-36 Sound power level - I.U. db(a) 57 59 Air flow Hi/Mi/Lo-ULow m3/h 700-640-560-440 740-700-640-560 Drain hose diameter mm 16 16 Remote Controller (st. equipment) Type IR Wireless IR Wireless Outdoor Unit Specifications Outdoor Unit Dimension (WxHxD) mm 760x590x285 845x700x320 Net kg 35.5 46 Noise level - O.U. db(a) 58 60 Sound power level - O.U. db(a) 61 65 Max air flow m3/h 2200 2500 Options Wired control DTW 3 IHXR, DTW IHXR Simply, DTWS 3 IHXR Compact Centralized control DTC IHXR Touch, DTC IHXR, DTCWT IHXR (all with NIM-GRH) Weekly timer DTWT 1 IHXR, DTWT IHXR 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 27

LIGHT COMMERCIAL FULL DC INVERTER Ceiling/floor easy installation timer 24h dry HSFI X Model HSFI 539 X HSFI 719 X HSFI 1089 X HCKI 539 X HCKI 719 X HCSI 1089 X Type FULL DC-Inverter FULL DC-Inverter FULL DC-Inverter Capacity (T=+35 C) Cooling W 5275 (1578~6077) 7034 (1899~7830) 10800 (3068~12037) Power Input (T=+35 C) Cooling W 1450 (300~2020) 2070 (380~2610) 3290 (600~4250) Annual Consumption Cooling kwh/a 299 387 656 Energy efficiency class seasonal Cooling 626/20111 A++ A++ A+ Energy efficiency seasonal index Cooling SEER2 6.2 6.6 5.6 Coefficient of Energy Efficiency Rated Cooling EER3 3.64 3.40 3.28 Design load (Pdesignc) Cooling kw 5.30 7.30 10.50 Capacity (T=+7 C) Heating W 5862 (1607~6661) 7620 (1987~8502) 12050 (3155~12563) Power Input (T=+7 C) Heating W 1410 (280~2000) 1900 (370~2620) 3240 (590~4120) Annual Consumption Heating kwh/a 1953 2947 3684 Energy efficiency class (average season) Heating 626/20111 A A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP3 4.16 4.01 3.72 Design load (Pdesignh) Heating kw 5.30 8.00 10.00 T operational limit (Tol) Heating C -15-15 -15 Power supply Ph-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ I.U. + O.U. I.U. + O.U. I.U. + O.U. I.U. + O.U. Current consumption (MAX) A 15 15 11 Wiring cables i.u./o.u. (without ground) n STP(2 plus + ordinary one) STP(2 plus + ordinary one) STP(2 plus + ordinary one) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø12.7 (1/2 ) ø9.52 (3/8 ) - ø15.88 (5/8 ) ø9.52 (3/8 ) - ø15.88 (5/8 ) Max splitting distance indoor/outdoor m 30 50 65 Max splitting level difference I.U./O.U. m 20/9 25/9 30/12 Refrigerant (GWP)4 R410A (1975) R410A (1975) R410A (1975) Refrigerant Precharge kg 1.80 2.20 3.00 MAX Splitting with Refrigerant Precharge m 5 5 5 Additional Refrigerant Charge g/m 15 30 30 Temperature range Cooling C -15 C ~ +50 C -15 C ~ +50 C -15 C ~ +50 C Temperature range Heating C -15 C ~ +24 C -15 C ~ +24 C -15 C ~ +24 C Indoor Unit specifications Indoor Unit Dimension (WxHxD) mm 1068x675x235 1068x675x235 1650x675x235 Net kg 25 25 40 Noise level - I.U. Hi-Mi-Lo db(a) 46-37-34 55-38-35 54-49-46 Sound power level - I.U. db(a) 60 63 65 Air flow Hi-Mi-Lo m3/h 900-750-600 1400-1250-1100 2200-1850-1500 Drain hose diameter mm 25 25 25 Remote Controller (st. equipment) Type IR Wireless IR Wireless IR Wireless Outdoor Unit Specifications Outdoor Unit Dimension (WxHxD) mm 845x700x320 900x860x315 990x965x345 Net kg 46 59 77 Noise level - O.U. db(a) 60 60 63 Sound power level - O.U. db(a) 65 69 70 Max air flow m3/h 2500 3500 5500 Options Wired control DTW 3 IHXR, DTW IHXR Simply, DTWS 3 IHXR Compact Centralized control DTC IHXR Touch, DTC IHXR, DTCWT IHXR Weekly timer DTWT 1 IHXR, DTWT IHXR 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 28

LIGHT COMMERCIAL FULL DC INVERTER Duct Medium Static Pressure fresh air low noise timer 24h dry HUCI X Model HUCI 359 X HUCI 539 X HUCI 719 X HUCI 1089 X HCKI 359 X HCKI 539 X HCKI 719 X HCSI 1089 X Type FULL DC-Inverter FULL DC-Inverter FULL DC-Inverter FULL DC-Inverter Capacity (T=+35 C) Cooling W 3517 (1400~4000) 5275 (1578~6048) 7034 (1899~7888) 10800 (3068~12037) Power Input (T=+35 C) Cooling W 1080 (300~2020) 1460 (300~2020) 2060 (370~2610) 3290 (600~4240) Annual Consumption Cooling kwh/a 214 290 376 721 Energy efficiency class seasonal Cooling 626/20111 A A++ A++ A Energy efficiency seasonal index Cooling SEER2 5.3 6.4 6.7 5.1 Coefficient of Energy Efficiency Rated Cooling EER3 3.26 3.61 3.41 3.28 Design load (Pdesignc) Cooling kw 3.50 5.30 7.20 10.50 Capacity (T=+7 C) Heating W 4103 (1400~4750) 5862 (1607~6661) 7620 (1987~8531) 12050 (3155~12563) Power Input (T=+7 C) Heating W 1080( 290~2010) 1450 (290~2010) 1950 (370~2610) 3210 (580~4090) Annual Consumption Heating kwh/a 1378 1953 2947 3868 Energy efficiency class (average season) Heating 626/20111 A A A A Energy efficiency seasonal index (average season) Heating SCOP2 3.8 3.8 3.8 3.8 Coefficient of Energy Efficiency Rated Heating COP3 3.80 4.04 3.91 3.75 Design load (Pdesignh) Heating kw 3.50 5.30 8.00 10.50 T operational limit (Tol) Heating C -15-15 -15-15 Power supply Ph-V-Hz 1-220~240V-50HZ 1-220~240V-50HZ 1-220~240V-50HZ 3-380~400V-50HZ I.U. + O.U. I.U. + O.U. I.U. + O.U. I.U. + O.U. I.U. + O.U. Current consumption (MAX) A 9.5 10 15 11 Wiring cables i.u./o.u. (without ground) n STP(2 plus + ordinary one) STP(2 plus + ordinary one) STP(2 plus + ordinary one) STP(2 plus + ordinary one) Refrigerant circuit Refrigerant Pipe Liquid/Gas side mm/inch. ø6.35 (1/4 ) - ø9.52 (3/8 )ø6.35 (1/4 ) - ø12.7 (1/2 )ø9.52 (3/8 ) - ø15.88 (5/8 ) ø9.52 (3/8 ) - ø15.88 (5/8 ) Max splitting distance indoor/outdoor m 20 30 50 65 Max splitting level difference I.U./O.U. m 10/5 20/9 25/9 30/12 Refrigerant (GWP)4 R410A (1975) R410A (1975) R410A (1975) R410A (1975) Refrigerant Precharge kg 1.10 1.80 2.20 3.00 MAX Splitting with Refrigerant Precharge m 5 5 5 5 Additional Refrigerant Charge g/m 15 15 30 30 Temperature range Cooling C -15 C ~ +50 C -15 C ~ +50 C -15 C ~ +50 C -15 C ~ +50 C Temperature range Heating C -15 C ~ +24 C -15 C ~ +24 C -15 C ~ +24 C -15 C ~ +24 C Indoor Unit specifications Indoor Unit Dimension (WxHxD) mm 700x210x635 920x270x635 920x270x635 1200x300x865 Net kg 18 28 28 44 Noise level - I.U. Hi-Mi-Lo db(a) 41-38-36 45-38-36 46-39-36 43-44-38 Sound power level - I.U. db(a) 57 59 63 64 Air flow Hi-Mi-Lo m3/h 800-610-520 1400-1100-1000 1700-1400-1250 2270-1890-1650 Available static pressure Pa 40 70 70 80 Air discharge flange Dimension (WxH) mm 493x119 713x179 713x179 968x204 Drain hose diameter mm 25 25 25 25 Remote Controller (st. equipment) Type IR Wireless IR Wireless IR Wireless IR Wireless Outdoor Unit Specifications Outdoor Unit Dimension (WxHxD) mm 760x590x285 845x700x320 900x860x315 990x965x345 Net kg 35.5 46 59 77 Noise level - O.U. db(a) 58 60 60 63 Sound power level - O.U. db(a) 61 65 69 70 Max air flow m3/h 2200 2500 3500 5500 Options Wired control DTW 3 IHXR, DTW IHXR Simply, DTWS 3 IHXR Compact Centralized control DTC IHXR Touch, DTC IHXR, DTCWT IHXR Weekly timer DTWT 1 IHXR, DTWT IHXR 1 Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners. 2 Commission Delegated Regulation (EU) No 206/2012. Value measured according to EN14825. 3 Value measured according to EN14511. 4 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.this appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 29