GB/DAS User Instruction



Similar documents
Article: Version:

Installation Guide. DEVIreg 530. Electronic Thermostat.

Installation Instructions

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DEVIreg 330 (+5 to +45 C)

Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

User Manual THR840DUK Digital Thermostat

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

HERZ-Thermal Actuators

Wireless 7 Day Programmable Room Thermostat

EK908FHL - Thermostat for floor heating

OPERATING INSTRUCTIONS

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

TIG INVERTER INSTRUCTION MANUAL

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Drayton Digistat +2RF

ROBERTS. Enjoy Listening. DAB / FM RDS Digital Clock Radio with large display. Please read this manual before use

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Wireless Indoor/ Outdoor Thermometer

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

OZW30. Central Unit SYNERGYR

Regulators. Heat pumps. Qualified technician NIBE TM AP-CS2.0. Operating Instructions UK

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Single Channel Loop Detector

Installation & Maintenance Instructions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

SETTING UP YOUR 6000 SERIES TIME RECORDER

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

Network Time Accessories LED CLOCK. (for NTP Synchronization)

5W LED Energy Saver PIR Bulkhead

H45 LED - Direct and indirect pendant

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Wireless Thermostats 230v and Battery Operated Instruction Manual

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Operating instructions. RCD flat 4-fold, 6-fold

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Manual. Solar Fountain Mobile Phone Charger

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

INSTALLER S & OWNER S MANUAL

INFRARED QUARTZ WALL HEATER

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Wireless Home Security System Product Manual (Model #80355)

LCD5500Z / PKP-LCD v3.x Installation Instructions

B/S/H/ Error codes and service programmes PH

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Mobile Data Power Model: MDP-25

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

Operating instructions IV / 2007

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Operating Instructions. Room temperature controller

2-SLICE COOL TOUCH TOASTER

REMOTE TERMOMETER TE 219 LED USER MANUAL

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

INSTALLATION AND OPERATION MANUAL

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

BroadBand PowerShield. User Manual

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Contact Details. Please note that some of the contact details on this PDF document may not be current.

GSM Alarm System User Manual

Thermostat with display

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Awning Instructions. Full Cassette 1.5m to 6m

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EBDSPIR-PRM, EBDSPIR-PRM-IP

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Infrarot-Bewegungsmelder IP44

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Multi-Protocol decoder with Load regulation

Transcription:

GB/DAS User Instruction devireg 540/550

Table of contents Introduction 3 Introducing devireg 540/550 4 How to use your deviheat heating system 6 Daily operation 7 Setting the clock & day 10 Timer programming 11 Warranty 16 Do not cover the thermostat, e.g. by hanging towels etc. directly in front of it! 2

Introduction You have purchased a devireg 540/550 thermostat, which forms an integrated part of a deviheat system. DEVI has developed the devireg 540/550 to make your fl oor heating an even more environmentally correct way of heating your home. devireg 540/550 will work dynamically with both the room and floor temperature in order to give you the highest possible comfort in the most economical way. devireg 550 ONLY: Furthermore, devireg 550 will take a few days to optimise the use of the heating system, but it does not stop there. The devireg 550 will continue to learn from the room and thus constantly improve its performance and consequently your comfort and economy. We wish you many years of comfort with your new deviheat system. 3

Introducing devireg 540/550 devireg 540 is an advanced temperature controller, with a built-in Timer. devireg 550 ONLY: devireg 550 is an adaptive temperature controller, specially designed for fl oor heating systems. The devireg 550 will measure the radiant comfort from the fl oor combined with the comfort from the air temperature in the room to offset the outside weather condition. We as human beings perceive comfort as the combined effect of the radiant heat from the fl oor and air temperature in the room. By continually measuring this combined effect, it is therefore possible to maintain the highest possible comfort level. A higher fl oor radiant temperature can produce a sense of comfort with a lower air temperature which can result in lower running costs without reducing comfort levels. 4

All this means that as soon as you have set your devireg 550 at your desired comfort temperature, you do not have to do anything else. devireg 550 will automatically adjust the heating to meet your requirements for comfort and economy, no matter how the weather is changing outside. This also means that devireg 550 is capable of detecting a sudden temperature drop in the room. Instead of switching the heating on to immediately compensate, the devireg 550 uses the information stored then checks to see if this is caused by e.g. the effects of a window opened for 10 minutes! Even the programming of economy temperatures (i.e. during the night) is very simple. You do not have to calculate how much earlier the heating should start in order to reach a specifi c temperature at a specifi c time. Just tell the devireg 550 when you want the comfort temperature and the devireg 550 will take care of the rest. By learning the rate of heat loss from the room, the devireg 550 knows when to start heating in order to achieve the selected temperature at exactly the right time. 5

How to use your deviheat heating system The function of the button The button can be turned both ways, is indicated by or the button can be pressed/held, is indicated by View of symbols in the display Symbol for Timer On Symbol for frost protection Numerical display for time, temperature, text, etc. Weekdays Flashing point for actual time Symbol for setting of clock 6 Symbol for temperature below set-point Symbol for degrees Indication of AM/PM time at 12 hour clock 24 hour clock-ring which shows actual time and timer programme Symbol for Timer programming

Daily operation devireg 540/550 has two temperature settings: Constant temperature with the timer off. Can be used e.g. as Party Mode or for constantly lowering the temperature when going on holiday. This is indicated by a continuous clock ring... Timer setting with automatic switching between economy and comfort temperature. Clock and timer must be set! Is indicated by the timer symbol and the clock ring showing the timer programme... (Display will indicate same temperature during both comfort and economy periods. But temperature will, during economy periods, be lowered according to the set-back level.) 7

You want to raise the temperature... Turn clockwise to raise the temperature. You want to lower the temperature... Turn counter-clockwise to lower the temperature. You want to switch on or off the timer function... Economy set-back between 00 00 and 07 00 Press the button to switch on the timer. Press again to switch off the timer. 8 The clock is between 10 00 and 10 30

The marking on the clock-ring indicates when comfort temperature is chosen and when economy set-back is switched on. A fl ashing point indicates the actual clock (every half hour). If the temperature is lowered to minimum (+5ºC), a frost symbol will appear in the display, indicating that the thermostat will maintain minimum +5ºC in the room for frost protection. If the temperature is turned below +5ºC, the thermostat will switch off. (Only possible with the timer off) When the temperature is raised again the thermostat will automatically switch on. If the devireg 540/550 only uses a fl oor sensor, the display will not show the actual temperature (5º to 35º), but a scale from 0 to 10. 9

Setting the clock & day You want to set/change the clock... (The clock is not set from the factory) 3 sec. Hold the button for 3 sec. The clock can now be set forward or back by turning the button to the right or left respectively. Changing the week day is done by continuing to change the time until it passes 0:00, either way. The numbers 1-7 do not correspond to any specifi c days, so you can choose which day of the week is No. 1 etc. When the clock is set correctly, press the button to save the settings. 10

Timer programming You want to set/change the economy set-back programme... (The timer is not set from the factory) Hold the button for 6 sec. The programme for economy set-back can now be edited. 6 sec. First, turn the button to choose the weekday which you want to programme... Press the button to start the programming... 11

The button is alternately turned and pressed to choose periods with economy set-back and periods with comfort temperature respectively. The programming switches between low (economy set-back) and high (comfort) temperature every time you press the button. And between every time you press, you can turn the button and choose the period of time. 12

Example When you enter the programming menu choose a day and press the button... Turn until you reach the fi rst time when you want comfort temperature, e.g. 06:00. Press... Turn until the temperature must be lowered again, e.g. 07:30. Press... 13

And turn to the next comfort period, e.g. 15:30, and press... Then, turn until you reach the time when the next lowering of the temperature must start, e.g. 22:30, and press... 14

If you continue to turn, the programme will automatically continue with the next day. This way, the programming can continue for the entire week. End When you have ended the programming, the changes must be saved. This is done by holding the button for 3 sec. The display will automatically return to normal display. 3 sec. Remember (devireg 550 ONLY): With devireg 550 you only have to programme the time when you want comfort temperature and the time you want economy temperature. The thermostat will do the rest. You do not have to calculate when the heating should start; devireg 550 will do this for you. 15

The DEVI Warranty: You have purchased a deviheat 550 thermostat, which forms an integrated part of a deviheat system, which we are certain will improve your home comfort and economy. deviheat provides complete heating solutions with devifl ex heating cables or devimat heating mats, devireg thermostats and devifast fi tting bands. If, however, contrary to all expectations, a problem should occur with your heating system, we at DEVI, with manufacturing units in Denmark, are, as European Union suppliers, subject to general product liability rules, as stated in Directive 85/374/ CEE, and all relevant national laws which implies that: DEVI provides a warranty for devifl ex heating cables and devimat heating mats for a 10 year period and all other DEVI products for a 2 year period against defects in material and production. The guarantee is granted on the condition that the WARRANTY CERTIFICATE on the overleaf is fi lled out properly in accordance to instructions and that the defect is inspected by, or presented to, DEVI or authorised DEVI distributor. Please note that the wording of the WARRANTY CERTIFICATE must be provided in English or local language with the ISO code for your country in the upper left corner of the front page of the installation instructions in order to release the warranty. The obligation of DEVI will be to repair or supply a new unit, free of charge to the customer, without secondary charges linked to repairing the unit. In case of defective devireg thermostats, DEVI reserves the right to repair the unit free of charge and without unreasonable delay to the customer. The DEVI warranty does not cover installations made by unauthorised electricians, or faults caused by incorrect designs supplied by others, misuse, damage caused by others, or incorrect installation or any subsequent damage that may occur. If DEVI is required to inspect or repair any defects caused by any of the above, then all work will be fully chargeable. The DEVI warranty is void, if payment of the equipment is in default. At all times, we at DEVI will respond honestly, effi ciently and promptly to all queries and reasonable requests from our customers. The above mentioned warranty concerns product liability whereas matters in relation to legislation on sale of goods shall be referred to national law.

The DEVI Warranty is granted to: Name: Address: Warranty Certificate Postal code: Phone: Please Observe! In order to obtain the DEVI Warranty, the following must be carefully filled in. See other conditions on the overleaf. Electrical Installation by: Type of thermostat: Installation date: Production code: Suppliers Stamp: DEVI DK 7100 Vejle Phone +45 76 42 47 00 Fax +45 76 42 47 03

Connection diagram: Network connection devireg 550 ONLY 29

Technical specifications: Temperature range: +5º to +35 C or OFF Floor temperature limit: +20º to +50ºC Voltage: 180-250 V ~ 50/60 Hz Resistive load: 250 V ~ 16 A Inductive load: 1 A (power factor 0.3) Power consumption: < 500 mw Battery back-up: 100 hours Economy set-back: 0º to -30ºC Offset: -5.5º to +5.5ºC IP class: IP 30 Type of sensor: NTC Sensor value: 15 kohm / 25ºC 28

No: Fault: What to do: 2 Confi gured as Master, but can detect another Master unit Only one unit may be confi gured as a Master 6 Sensor fault fl oor sensor open circuit Change the fl oor sensor 5 Sensor fault fl oor sensor shortcircuit Change the fl oor sensor 27

Error messages: devireg 540/550 has a built-in system that constantly checks the heating system, the thermostat itself and a possible network for any malfunctions. If an error occurs, the display will fl ash together with a reading of the detected fault, which will be shown indicated by the weekday numbers 1 to 7: No: 7 Fault: Clock is not adjusted What to do: Set the clock 4 The thermostat is switched off because of overheating Let the thermostat cool for a period. Then enter basic setup to leave fault mode 3 Confi gured as a Slave, but cannot fi nd any Master unit One unit must be confi g- ured as Master 26

If more master units are confi gured on the network, an error message will fl ash in the display, and the unit will need to be reconfi gured. If a devireg 550 is confi gured as a slave unit, the following set-up parameters are controlled from the master unit: Time Day of week Cº or Fº 12 hour AM/PM or 24 hour clock Set back program Network accessories: Network cable 15881150 Single core 0,75 mm 2 (100 m) 25

Network connections (devireg 550 ONLY): The devireg 550 features a network capability. All devireg 550 s installed in a building can be linked together via the network facility, giving the possibility of central adjustment of programming and parameters e.g. clock setting. The network can include up to 32 units, i.e. 1 master and up to 31 slave units. It is only possible to have one master unit. A devireg 550 can be set as a stand alone unit, even though it is connected to the network. It will not respond to or send information to a master unit, but it will count as one of the maximum 32 units in the network. The network is a seperate two wire net, where the cables are unshielded, untwisted and unpolarised for easy installation. The maximum length of the network cables are up to 500 metres. 24

Factory setting: The thermostat is preset with the following parameters: Operation Factory setting Choices Network type Alone Alone, Master or (devireg 550 ONLY) Slave Temp. display Cº Cº or Fº Sensor Room + fl oor Room, fl oor or room + fl oor Max. fl oor temperature +45ºC +20ºC to +50ºC Offset 0.0ºC -5.5ºC to +5.5ºC Economy set-back -5ºC -1º to -30ºC Weekday 1 1, 2, 3, 4, 5, 6, 7 Clock 24 12 hours AM/PM or 24 hours Time --:-- --:-- Timer settings - Up to 336/week 23

Finally, the type of clock must be set. Choose whether the clock must be 24 hours or 12 hours AM/PM. Turn to choose 12 or 24 hours, and press... To fi nish the basic setting, press the button, and the display will return to the daily operation menu. 22

In connection with the built-in Timer, the thermostat can be programmed to lower the temperature (LO), e.g. during the night. The range is 0ºC to -15ºC. Turn to choose economy set-back level, and press... (Choose -5ºC if the temperature must be lowered 5 degrees). If normal room heating is installed we recommend not to lower the temperature at night with more than approx. -5ºC. 21

Offset (OFFS) can be used to adjust a variation between the thermostat and a thermometer in the room, if any. If the thermometer shows e.g. 1ºC more than the thermostat, it is possible to adjust the offset with +1ºC. The range is -5.5ºC to +5.5ºC. Turn to choose offset, and press... 20

Due to different fl oor constructions it is possible to choose a maximum fl oor temperature (Mt) in the fl oor which cannot be exceeded. The temperature range is 20ºC to 50ºC. Turn to choose maximum fl oor temperature, and press... Please note! Maximum fl oor temperature is preset from the factory to 45ºC for cable temperature safety. Local building regulations must be observed, when changing the maximum preset temperature. For wooden fl oor constructions DEVI recommend to limit the temperature to maximum 27ºC. Max. temperature setting for different fl oor constructions! Tiles on chipboard Carpet/vinyl on chipboard Wooden fl oors (parquet, plank, etc.) Other (concrete, screed, etc.) 27ºC 35ºC 27ºC 45ºC 19

devireg 540/550 is able to use two sensors, one built-in sensor plus an external sensor which can be placed e.g. in the fl oor. Choose the sensor(s) which will be used for this heating system. Turn to choose Room Sensor (r S), Floor Sensor (FS) or both Room and Floor Sensor (rfs), and press... (If the thermostat only uses a fl oor sensor, the display will not show the actual temperature (5º to 35º), but a scale from 0 to 10). Always use a floor sensor when the heating element is installed on or beneath wooden surfaces! 18

Choose whether the thermostat must show Celcius or Fahrenheit degrees. Turn to choose Cº or Fº, and press... 17

devireg 550 ONLY: The fi rst function to choose in the basic setting is whether devireg 550 must operate Alone or as Master or Slave thermostat. If several thermostats are linked in one network, only one of the thermostats can be choosen as Master! For further information about network and Master/Slave, see section on page 24. Turn to choose Alone (ALO), Master (MAS) or Slave (SLA), and press... Please note! If Slave is chosen, not all settings in the Basic Setting will appear. The settings left out can be set from the Master unit. 16

Change of basic setting If it is necessary to change the basic setting, the button must be held for 12 sec. It is then possible to access the basic setting menu by choosing the code! Turn to choose code... Choose the code: 0044 When the code is chosen, press the button... 12 sec. 15

devireg 540/550 is able to use two sensors, one built-in sensor plus an external sensor which can be placed in the fl oor. Choose the sensor(s) which will be used for this heating system. Turn to choose Room Sensor (r S), Floor Sensor (FS) or both Room and Floor Sensor (rfs), and press... (If the thermostat only uses a fl oor sensor, the display will not show the actual temperature (5º to 35º), but a scale from 0 to 10). Always use a floor sensor when the heating element is installed on or beneath wooden surfaces! 14

Activating devireg 540/550 When the thermostat is connected to the mains voltage for the fi rst time, a code must be chosen and the sensor(s) selected. Turn to choose code... Choose the code: 0044 When the code is chosen, press the button... Now the sensors to be used, should be selected... 13

12 DO NOT over tighten!

Reassemble the thermostat by fi rst placing the frame, then mount the display module and fi nally press the front cover into place. Note: The display must be gently remounted on the base module, ensuring that the 8-pin plug is placed accurately by using the four tabs surrounding it. When remounting the two screws in the side, please DO NOT over tighten them. They just need to be barely fastened. 11

In order to get the best possible result when using the devireg 540/550, the thermostat should be installed in the wall, following a few basic rules: - - - - - Installation height, typically between 80-150 cm. On a wall NOT facing the outside On a wall where it will NOT be subjected to direct sunlight Away from windows/doors that will open occasionally It must not be covered by curtains, towels etc. The devireg 540/550 should not be installed in small rooms with insuffi cient ventilation, such as bathrooms. In these instances, place the thermostat just outside the room (only use the fl oor sensor - FS). The thermostat must not be placed close to areas with a high risk of water stains, e.g. close to running water, toilets etc. 10

Warning (devireg 550 ONLY): Please note, when working on thermostats connected to a network, ensure that the mains supply for all thermostats in the network is disconnected before the work is started. Screw holes You can now mount the thermostat in the wall, by using any of the eight screw holes in the base module. 9

When installing the devireg 540/550 you need to choose the type of heating and thus which sensors should be used. DEVI recommend always to install the floor sensor! Comfort Heating: - Constant temperature on the fl oor in e.g. bathrooms and other rooms that are often used with bare feet. - Install the Floor sensor and choose only the Floor sensor in Basic Settings. Total Room Heating: - Control of room temperature in living rooms etc. - Install the Floor sensor and choose both Floor sensor and Room sensor in Basic Settings. No Floor Sensor: - A fl oor sensor is not present, and cannot be installed. - Choose Room sensor only in Basic Settings. - Be aware that temperature control is less accurate without the fl oor sensor. DEVI recommend that a fl oor sensor is installed. Do NOT use devireg 540/550 without floor sensor when the heating element is installed on or beneath wooden surfaces! 8

Connection of the thermostat must be carried out as shown below. Heating element Max. load 16 Amp. Mains supply NTC sensor 180-250 V 50/60 Hz Network connection devireg 550 ONLY As the devireg 540/550 is not equipped with an earth terminal, the earthing screen of the heating cable must be connected to the earth from the supply via the earthing terminal in the surface mounted box or the recessed metal box which ever is used. 7

Remove the frame from the thermostat. Frame 6

Remove the two screws, one in each side, and gently pull off the display module. Screws 5

Installation of devireg 540/550: When installing devireg 540/550 you must fi rst dismantle the thermostat. Remove the front cover by gently pressing the release tab in the top (center hole), and lift out the cover. Release tab 4

Table of contents Installation of devireg 540/550 4 Activating devireg 540/550 13 Change of basic setting 15 Factory settings 23 Network 24 Error messages 26 Technical specifi cations 28 Connection diagram 29 Please Note: The devireg 540/550 must be connected and the basic setting must be done by an authorised electrician. In-appropriate installation and basic setting may cause damage to the heating system or fl oor construction. 3

GB/DAS Installation Instruction devireg 540/550 08095121 03.03