new Eyecatchers From design to art 2008 Ex
The information in this price list is correct at the time of printing. Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. Prices valid from 01.06.2008. All prices exclude VAT. Replaces all existing price lists.
produces 40% more warmth 1
he symbol of beautiful sunshine. The symbol of beautiful sunshine. 2 Iguana Plus is more than a functional radiator; it is an efficient radiator of warmth, designed with real feeling, and providing excellent value for money. Inspired by a child s drawing, the Iguana Circo is an interpretation of the brightly shining sun, transformed into a fully functional work of art. Representing the birth of a new range of sunshine radiators, Iguana has the essential, natural yet light hearted touch that creates a feeling of real warmth in its modern design. It s heating straight from the soul.
3
4 Iguana Plus gives 40% more warmth. p Iguana Plus is designed to work effectively with environmentally friendly low temperature heating systems. With the Iguana Plus, sustainability and heating comfort goes hand in hand. Its higher heat output means that the water temperature can be significantly reduced. Still keeping its power, Iguana Plus is also suitable for use with heat pumps, solar systems and the newest low carbon technologies. The new Iguana Plus wins hands down which ever way you look at it.
Aplano Plus with Danfoss Deco thermostatic valve I 180 x 52 I sandblast grey metallic 001
Aplano Plus Dimensions APPW_Aplano Plus Wall 7 9.5 12.1 9.0 air vent G 1/8 0.25 C 4.5 5 2.5 Prices & outputs Standard delivery : - Aplano Plus with central connection MM underneath - wall fixing - 2 chrome-plated air vents G 1/8 - side panel Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) H Iguana APPW ORDERING CODE: code height length colour conn. APPW. 180 030. XXX /MM H 030 041 052 063 074 085 180 75/65/20 964 1314 1664 2015 2365 271 6 55/45/20 465 634 802 972 1140 1310 7 10 7 192 75/65/20 997 1359 1721 2084 2446 280 9 55/45/20 480 655 829 1004 1179 1354 0.6 8.8 min. 10 Dimensions in cm 31 41 52 63 74 85 C 16.0 27.0 38.0 49.0 60.0 71.0 5 G1/2" M M 200 75/65/20 1018 1388 1758 2128 2498 2868 55/45/20 491 669 847 1026 1204 1382 220 75/65/20 1070 1460 1849 2238 2627 3016 55/45/20 515 703 891 1078 1265 1453 Connections Standard connection Code MM 240 75/65/20 1121 1529 1936 2344 2751 315 9 55/45/20 539 736 932 1128 1324 1520 M M 4 5 Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Arco Plus with manual valve I 180 x 51 I aluminium 006
Arco Plus Dimensions ARPW_Arco Plus Wall D E F 0.25 C 5 4.5 2.5 Prices & outputs Standard delivery - Arco Plus with central connection MM underneath - wall fixing - 2 chrome-plated air vents G 1/8 - side panel 7 air vent G 1/8 9.5 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) H Iguana ARPW ORDERING CODE: code height length colour conn. ARPW. 180 029. XXX /MM H 029 041 051 062 073 083 10 E 7 min 10 5 180 75/65/20 999 1362 1725 2088 2452 2815 55/45/20 496 676 856 1036 1217 1397 192 75/65/20 1046 1427 1807 2187 2568 2948 55/45/20 521 710 899 1088 1278 1467 9 Dimensions in cm 29.8 41.0 51.9 62.5 73.3 83.9 G1/2" M M 200 75/65/20 1076 1467 1858 2249 2641 3032 55/45/20 537 732 927 1122 1317 1512 C 10.0 20.0 30.0 40.0 50.0 60.0 D 14.1 16.1 17.7 17.2 18.7 20.7 E 8.1 10.1 11.7 11.2 12.7 14.7 F 7.6 7.9 7.3 8.0 7.5 7.4 Connections M M 4 5 Standard connection Code MM Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. 220 75/65/20 1146 1563 1980 2397 2813 3230 55/45/20 574 783 992 1201 1409 1618 240 75/65/20 1210 1650 2090 2530 2970 3410 55/45/20 609 830 1052 1273 1495 1716 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
10 Visio Plus with Deco-Pro thermostatic valve I 180 x 51 I aluminium 006
Visio Plus Dimensions VIPW_Visio Plus Wall D E F 0.25 C 5 4.5 2.5 Prices & outputs Standard delivery : - Visio Plus with central connection MM underneath - wall fixing - 2 chrome-plated air vents G 1/8 - side panel 7 air vent G 1/8 9.5 0.5 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) H Iguana VIPW code height length colour conn. ORDERING CODE : VIPW. 180 051. XXX /MM H 051 062 073 180 75/65/20 908 1271 1634 55/45/20 451 631 811 11 10 E 7 min 10 5 0.5 200 75/65/20 978 1369 176 0 55/45/20 488 683 878 Dimensions in cm 51.9 62.5 73.3 C 30.0 40.0 50.0 D 15.7 16.2 17.7 E 11.7 11.2 12.7 F 7.3 8.0 7.5 Connections G1/2" M M Standard connection Code MM 220 75/65/20 1042 1459 187 6 55/45/20 522 731 940 M M 4 5 Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Circo Plus wall with Deco-Pro thermostatic valve I 180 x 31 I sandblast grey metallic 001
Circo Plus wall Dimensions CIPW_Circo Plus Wall E D C 0.25 Prices & outputs Standard delivery: - Circo Plus wall model with central connection MM underneath - wall fixing - 2 chrome-plated air vents G 1/8 - side panel 7.6 5.0 G1/2" air vent G 1/8 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) Iguana CIPW code height length colour conn. ORDERING CODE : CIPW. 180 027. XXX /MM H H 027 031 034 180 75/65/20 1095 1294 149 3 55/45/20 558 659 761 192 75/65/20 1148 1357 156 6 55/45/20 591 699 807 13 Dimensions in cm Ø 27.8 31.3 34.8 C 7.4 10.8 14.4 D 18.2 19.7 21.7 E 11.7 13.6 15.5 Connections 4 5 M M 9.5 5 G1/2" Standard connection Code MM Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. 200 75/65/20 1181 1396 161 1 55/45/20 612 724 835 220 75/65/20 1251 1478 170 6 55/45/20 660 780 900 240 75/65/20 1301 1538 1775 55/45/20 699 826 953 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Angula Plus with Jaga Deco thermostatic valve I 180 x 46 I sandblast grey metalic 001
Angula Plus Dimensions ANPW_Angula Plus Wall 8.1 air vent G 1/8 11.4 12.1 E 5 A C B Prices & outputs Standard delivery : - Angula Plus with central connection MM underneath on the wider side. - wall fixing - 2 chrome-plated air vents G 1/8 - side panel Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) Iguana ANPW ORDERING CODE: code ANPW. height lengthcolour conn. corner 180 040. XXX/MM /C H H 040 046 051 180 75/65/20 1745 2078 2410 55/45/20 873 1040 1206 corner /C B 9.5 0.6 9 6.2 min. 10 5 G1/2" M M 192 75/65/20 1823 2170 2517 55/45/20 918 1093 1267 200 75/65/20 1871 2228 2584 55/45/20 946 1127 1307 corner /CR B 15 Dimensions in cm 40.0 45.5 51.0 B 29.0 34.5 40.0 A 10.3 13.1 15.8 C 9.8 15.3 20.8 E 20.8 26.3 31.8 Connections M M 4 5 Standard connection Code MM Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. 220 75/65/20 1978 2355 2732 55/45/20 1010 1203 1396 240 75/65/20 2066 2460 2854 55/45/20 1066 1270 1473 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Corner Plus with Jaga Deco thermostatic valve I 150 x 31 I white RA 9010
Corner Plus Dimensions COPW_Corner Plus Wall 21.2 17.7 90 90 22.2 Prices & outputs Standard delivery : - Corner Plus with central connection MM underneath - wall fixing - 2 chrome-plated air vents G 1/8 - side panel 21.2 17.7 0.25 5.0 22.2 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) 7.0 Iguana COPW ORDERING CODE: code height length colour conn. COPW. 125 031. XXX /MM H H 031 125 75/65/20 860 55/45/20 436 150 75/65/20 990 55/45/20 501 17 10 180 75/65/20 114 5 55/45/20 577 G1/2" M M 192 75/65/20 120 7 55/45/20 607 Connections 4 5 Standard connection Code MM 200 75/65/20 124 9 55/45/20 627 M M Top end connection Code 45 or 54 (1 number > flow) When ordering a top end connection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead of MM, no surcharge. One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring. 220 75/65/20 135 2 55/45/20 677 240 75/65/20 145 8 55/45/20 729 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Circo Plus freestanding with thermostatic head chrome I 240 x 27 I aluminium 006
Circo freestanding Dimensions CIRF_Circo Freestanding 0.25 E 5.0 G1/2" air vent G 1/8 9.5 Prices & outputs Standard delivery : - Iguana Circo in 2 parts, to be mounted around the suspension column, incl. all parts for hydraulic connection - support with suspension column and guards with opening for the valve head - thermostatic valve 5094.430 - lockshield 5094.431-4 chrome-plated air vents G 1/8 - sleeve couplings: see pag. 25 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) H Iguana CIRF code ORDERING CODE : CIRF. height length colour conn. 180 027. XXX /MM/ C H 027 031 034 Metal suspension column included 7.0 180 75/65/20 1602 1893 218 4 55/45/20 769 909 1049 192 75/65/20 1707 2018 2328 55/45/20 827 978 1128 19 23.0 13 ø3.5 0.8 200 75/65/20 1773 2096 2418 55/45/20 865 1022 1179 Dimensions in cm 27.8 31.3 34.8 E 7.5 9.4 11.3 Connections -9.0 Standard connection Code MM/C The standard flow is on the left (MM/ C). If standard flow on the right is required use the code suffix CR instead of C. 220 75/65/20 1923 2272 2622 55/45/20 953 1126 1299 240 75/65/20 2048 2421 2793 55/45/20 1030 1218 1405 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of the following pipe diameters 16/2, 18/1 or 18/2. M M Standard delivery: Guard and connection set with thermostatic valve and lockshield included. Thermostatic head: see table. Deco thermostatic head CODE Colour 5090.1111 c hrom e 5090.1110 c hrome / whit e chrome chrome / white
Circo Pillar cover with thermostatic head chrome I 180 x 31 I sandblast grey metalic 001
Circo pillar cover Dimensions CIRP_Circo Pilar Architectural or concrete pillar air vent G 1/8 0.25 E øz 5.0 G1/2" 9.5 Prices & outputs Standard delivery : - Iguana Circo in 2 parts, including all parts for hydraulic connection - suspension brackets for mounting around construction column - guards with opening for valve head - thermostatic valve 5094.430 - lockshield 5094.431-4 chrome-plated air vents G 1/8 - sleeve couplings: see pag. 25 Standard colours: - sandblast grey metallic 001 - white 301(RA 9010 satin) - white 333(RA 9016 satin) H Iguana CIRP code height length colour conn. ORDERING CODE : CIRP. 180 027. XXX /MM/ C H 027 031 034 180 75/65/20 1602 1893 218 4 55/45/20 769 909 1049 21 192 75/65/20 1707 2018 2328 55/45/20 827 978 1128 Dimensions in cm 23.0 13.0 ø3.5 0.8 200 75/65/20 1773 2096 2418 55/45/20 865 1022 1179 27.8 31.3 34.8 E 7.5 9.4 11.3 ØZ 11.0 12.5 16.0-9.0 220 75/65/20 1923 2272 2622 55/45/20 953 1126 1299 Connections Standard connection Code MM/C The standard flow is on the left (MM/ C). If standard flow on the right is required use the code suffix CR instead of C. 240 75/65/20 2048 2421 2793 55/45/20 1030 1218 1405 Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50). Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of the following pipe diameters 16/2, 18/1 or 18/2. M M Standard delivery: Guard and connection set with thermostatic valve and lockshield included. Thermostatic head: see table. Deco thermostatic head CODE Colour 5090.1111 chrom e 5090.1110 c hrome / whit e chrome chrome / white
38.1 45.1 Aplano Plus Arco & Visio Plus Corner Plus arge shelf in beech veneer arge shelf in beech veneer arge shelf in beech veneer 17 17 17 44 CODE For Aplano CODE For Arco and Visio CODE 9087.030400 41-52-63-74-85 40 9087.020529 41-51 53 9087.020543 62-73-83 54 9087.040628 S mall shelf in beech veneer Small shelf in beech veneer Small shelf in beech veneer 22 10 10 10 37 CODE For Aplano 9087.031400 41-52-63-74-85 40 9087.031500 52-63-74-85 50 CODE For Arco and Visio 9087.021480 41-51 48 9087.021512 62-73-83 51 CODE 9087.041528 Towel rail in chrome plated aluminium Towel rail in chrome plated aluminium Towel rail in chrome plated aluminium 8 8 10 35.1 36 CODE For Aplano 9087.033560 41-52-63-74-85 56 9087.033660 52-63-74-85 66 CODE For Arco and Visio 9087.023550 41-51 55 9087.023656 62-73-83 66 CODE 9087.043466 Hat rack chrome-plated aluminium Hat rack chrome-plated aluminium Hat rack chrome-plated aluminium 8 8 10 35.1 36 CODE For Aplano 9087.034560 41-52-63-74-85 56 9087.034660 52-63-74-85 66 CODE For Arco and Visio 9087.024550 41-51 55 9087.024656 62-73-83 66 CODE 9087.044466
Options Circo Plus wall I freestanding I column arge shelf in beech veneer Table in beech veneer 17 D D CODE Type D 9087.010637 ø 27 63.7 31.2 9087.010672 ø 31 67.2 32.9 9087.010707 ø 34 70.7 34.7 CODE Type D 9087.012660 ø 27 66.0 50.0 9087.012730 ø 31 73.0 55.0 9087.012800 ø 34 80.0 60.0 Small shelf in beech veneer 10 Foot for Circo Plus freestanding, for concrete floor. D 23 CODE Type D 9087.011497 ø 27 49.7 24.2 9087.011532 ø 31 53.2 25.9 9087.011567 ø 34 56.7 27.7 Finished floor level Rod (thread M16 ) not delivered as standard. Towel rail in chrome plated aluminium 8 D CODE Type 9086.000278 ø 27 9086.000313 ø 31 9086.000348 ø 34 CODE Type D 9087.013427 ø 27 42.7 22.1 9087.013427 ø 31 42.7 22.1 9087.013493 ø 34 49.3 25.3 Hat rack chrome-plated aluminium 8 D CODE Type D 9087.014427 ø 27 42.7 22.1 9087.014427 ø 31 42.7 22.1 9087.014493 ø 34 49.3 25.3
Connection sets with Deco-Pro thermostatic valves For connection to the wall CODE 41 Thermostatic head CODE.PW3.DW.1... c hrome / whit e CODE.PW3.DC.1... c hrom e fill in sleeve coupling F or connection to the floor CODE 42 CODE.PF3.DW.1... CODE.PF3.DC.1... Thermostatic head c hrome / c hrom e whit e ONE PIPE AND TWO PIPE 5 Deco-Pro angled valve 5 Thermostatic head left or right ONE PIPE AND TWO PIPE Sleeve couplings Deco-Pro straight valve 24 fill in sleeve coupling Sleeve couplings Thermostatic head left or right Connection sets with Deco manual valves For connection to the wall CODE 31 CODE.MW2.MW.1... CODE.MW2.MC.1... CODE.MW2.MB.1... fill in sleeve coupling Head w hite c hrom e b lack F or connection to the floor CODE 32 CODE.MF2.MW.1... CODE.MF2.MC.1... CODE.MF2.MB.1... fill in sleeve coupling Head w hite c hrom e b lack TWO PIPE Sleeve couplings Deco Deco angled lockshield TWO PIPE Deco Deco straight lockshield Sleeve couplings Deco angled manual valve Deco straight manual valve Complete ordering code with sleeve couplings depending on the material used and ø of the tube. EXAMPE c ode sleeve coupling CODE. MW2. MW. 1 110
Connection sets Connection set with Jaga Danfoss-Pro For connection to the wall CODE Colou r chrome Chrome-plated sleeve couplings Included in the price of the connection sets 5094.444 c hrom e 5094.445 b rushed stainless steel Only suitable for radiators up to a maximum of 1500 watt (75/65/20) Jaga Danfoss Deco-Pro angled valve - chrome Thermostatic head brushed stainless steel Thermostatic head Flexible steel or M24 Just for tube 18/1 copper M24 CODE Tube Ø 110 10/1 112 12/1 114 14/1 115 15/1 116 16/1 118 18/1 Jaga Danfoss Deco-Pro angled valve - brushed stainless steel Synthetic M24 CODE Tube Ø 212 12/2 214 14/2 219 16/1.5 216 16/2 217 17/2 218 18/2 25 RPE/AU CODE Tube Ø M24 S teel tube for M24 C.H. 314 14/2 316 16/2 326 16/2.2 318 18/2 CODE Tube Ø 501 1/2 504 3/8 M inus price: for set: 31-32-41-42
Exhibitions & Awards Salone del Mobile, `Super Studio Piu I Milano, IT Interieur Kortrijk I Kortrijk Xpo, BE VSK, I Utrecht, N and many others 26
Colour chart Iguana Plus is available in colours 201 to 233 (glossy) and 301 to 333 (satin mat) and special colours 201 301 RA 9010 white 215 315 RA 5018 turquoise 229 329 RA 6000 patina green 202 302 RA 9001 off-white 216 316 bermuda 230 330 aloa blue 203 303 RA 7035 light grey 217 317 RA 8017 chocolate brown 231 331 RA 7016 anthracite grey 204 304 RA 9005 black 218 318 RA 5015 azure 232 332 sunrise 205 305 pergamon 219 319 RA 4008 violet 233 333 RA 9016 traffic white 28 206 306 manhattan 208 308 RA 5003 sapphire blue 220 320 aegean 221 321 calypso Special colours 001 sandblast grey metallic 209 309 RA 7011 dark grey 222 322 capri 002 hammerstroke silver/black 210 310 RA 1004 golden yellow 223 323 natural 003 claret metallic 211 311 RA 3000 flaming red 224 324 edelweis 004 gold structure 212 312 bahama 225 325 jasmine 005 smooth grey metallic 213 313 RA 6009 english green 226 326 RA 3003 ruby red RA 9006 006 aluminium 214 314 whisper rose 228 328 classic white 007 anthracite metallic This colour chart is only indicative. It s impossible to obtain a 100% exact colour reproduction in printing. Metal slides with the different colours can be obtained on request. 008 anthracite structured All technical data and additional info, see http://www.theradiatorfactory.com/iguanaplus
Jaga International - Verbindingslaan z/n - B-3590 Diepenbeek - T: +32 11 29 41 16 - F: +32 11 29 41 60 - export@jaga.be - www.theradiatorfactory.com - www.jagaexperiencelab.com 27200.52120003-0609 - JAGA N.V.