Brochure 2012-2013.EX



Similar documents
Brochure EX

How To Buy A Designo Grille

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

KONRAD. Hybrid Fancoil Series

ECOCIAT. Domestic hot water heat recovery unit

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Under sill units. Type FSL-B-ZAS

new Eyecatchers From design to art 2008 Ex

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

1. Geo Vertical 2. Geo Horizontal

The space saving solution.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

HERZ-Thermal Actuators

Low-H2O valves Y EARS

Rittal TopTherm fan-and-filter unit

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

CRAC Precision climate control units for data centres

Drayton Digistat +2RF/+3RF

HDA

Portable Air Conditioner

HEAVY DUTY STORAGE GAS

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

RRV934. Multi-controller. Synco living

DCP Fan Controller. Version 01/2009. The engineer s choice

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

We have been working in an ideal climate for thirty years.

Stroom voor elke toepassing

Linear Luminaire with LED Series EXLUX 6402/2

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9


DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Installation, operation and maintenance manual TX 35A

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

2.12. page Products for Explosion hazardous Environment

RPV - RP - RA air handling units

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Technical catalogue convectors POLAND 2012

Aluminium Standard. Technical Data. Included in delivery

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Direct steam injection humidifiers

Jaga Low-H2O hydronic heating. Fin tube elements for low water temperatures and condensing boilers

HVAC air curtains. Type InduAir

Confort 26. Sliding Systems. Sapa Building System

IH E Sigma Island 90

RF 1. Contents: Connecting diagram. Detailed information:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

WD-AMX Water Detection Controllers

Guideline Laser Series

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Shunt lock function 3066

stainless steel pre-assembled manifolds

Installation Guide. DEVIreg 530. Electronic Thermostat.

Electronic Control Devices The European Product Catalogue 2007

BROWACOM PRODUCTS. Our web-pages can be found from:

Data sheet ECC 12 and 22

FTQ. Daikin Inverter Ducted Heat Pump

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Conlift1, Conlift2, Conlift2 ph+

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Digital input modules

I STAR COMPUTER CO., LTD

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Flexit Central Vacuum Cleaner

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Controls for fan coil units and cassettes

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Single sub-base valve

Universal Fibre Optics L E D L I G H T S O U R C E S

Electronic Control Devices The European Product Catalogue 2007

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Aludesign K A T A L O G

3500/93 System Display

DEVIreg 330 (+5 to +45 C)

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Terminal Boxes Series 8146

Electric Rotary Actuator - On/Off or programmable control actuator

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Thermostats. comfort at your command

Universal control module for motorized devices

Spetec. Laminar Flow Box. Portable Clean Room Technology


BeoLab 1. User s guide

Description. Dimensions. Features. precision works better

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Passion for KNX innovation

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transcription:

CLIMA CANAL Brochure 2012-2013.EX

CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation unit all in one. Silent and unobtrusive, clima canal provides the greatest possible climatic comfort. Super-compact and silent This high-tech Low-h2o heat exchanger with its thermal activator has been specially developed to deliver record output whitin super-compact dimensions. All this at an inaudible noise level of less than 29 dba! In boost mode, for ultra-quick heating or cooling, the output is even higher. using the latest ec motors enables clima canals to consume up to 50% less electrical energy, and enables remote control using the latest home automation and building management systems. Suitable for non-condensing and condensing cooling with chilled water 330

CLIMA CANAL 331

CLIMA CANAL SUMMARY DIMENSIONS (in cm ) 2.5 Ø 3 4 Option : 6 4 4 4 Mounted mouthpiece 9 20 18 for air supply channel H* = 8 cm heating L 10 cm hybrid 23.7 Ø 4 H* ORDERING CODE code height length width grille CLCM. 008 072 18 /XXX /XXX fill in grille code grille colour to be completed in BNC STANDARD DELIVERY - casing in Sendzimir-galvanised steel sheet (ral7024) with height adjustment and stainless steel grille support - anodized aluminium grille(s) - dynamic heat exchanger - 2 stainless steel flexible connections 1/2, length 15 to 25 cm. - thermal activator(s), (tangential mini activator) With energy efficient ec motor HYDRAULIC CONNECTION - one-sided 2-pipe connection on the left - always install clima canal with the heat exchanger on the window or wall side - 2 1/2 stainless steel hose included - allow extra space for curtains, in between the window and the clima canal. - The heat exchanger must always be kept accessible for maintenance purposes - if the appliance is not mounted flat on the floor, the space between the bottom of the appliance and the floor should be filled with a stable filler material. ELECTRIC CONNECTION - clamp connector for 24VDc electrical connection, right side, to be connected via external power supply. - control of speed activator(s) 0-10V COMPOSITION Cover plate Grille several styles and colours in anodized aluminium and a range of wood finishes Dynamic heat exchanger Tangential EC thermic activator(s) Stainless steel flexible connections 1/2 Length 15 cm Fine adjustment to max. 0.8 cm, for a perfect alignment with the finished floor 0 > 4 max. 0.8 Fine adjustment clima canal: 8.5 > 9.3 cm c. c. hybrid : 10 > 10.8 cm Housing with stainless steel grille support Condensate tray for condensate drain with the hybrid model Electric connection (always left ) Feet with height adjustment 0 > 4.5 cm Hydraulic connection (always left ) max. 0.8 332 0 > 4 jaga Top Performers

HEATING COOLING CLIMA CANAL CLCM.HHH LLL 18/XXX Watts Watts Watts Watts total Watts sensible 75/65/20 C 55/45/20 C 35/30/20 C 7/12 C - 25 C D.B. 50% R.H. 7/12 C - 25 C D.B. 50% R.H. BNA BON BNC BOV BBV max. med. min. max. med. min. max. med. min. max. med. min. max. med. min. BBN H L CLIMA CANAL 008 072 945 903 517 563 546 310 234 228 129 --- --- --- --- --- ---646,60 711,20 108 2075 2009 1137 1238 1201 682 514 501 284 --- --- --- --- --- ---884,20 972,60 144 3011 2912 1654 1798 1744 992 747 728 413 --- --- --- --- --- ---1232,40 1355,60 180 4145 4018 2274 2474 2403 1364 1028 1001 569 --- --- --- -- --- ---1398,20 1538,00 H L CLIMA CANAL HYBRID 010 072 945 903 517 563 546 310 234 228 129 284 273 110 213 205 83663,20 729,50 108 2075 2009 1137 1238 1201 682 514 501 284 576 545 219 433 410 165911,80 1003,00 144 3011 2912 1654 1798 1744 992 747 728 413 849 818 330 638 615 2481271,10 1398,20 180 4145 4018 2274 2474 2403 1364 1028 1001 569 1152 1090 440 866 820 3301436,80 1580,50 EN442 output at 20 C room temperature TECHNICAL DATA H L B FAN SOUND PRESSURE ** RATED INPUT AIR FLOW WATER FLOW db(a)watts m 3 /h l/h l/h Number max. *med.*min.*max.*med.*min.*max.*med.*min.*heating cooling 008/010 072 18 1 34 29 19 4.37 3.17 1.56 70 59 40 78 47 108 1 37 32 20 6.70 4.80 1.98 142 119 83 175 94 144 2 39 34 22 10.30 6.70 2.30 213 178 123 250 140 180 2 40 35 23 12.10 8.25 2.83 284 238 165 345 187 ** Height 1 metre, 2 metres from the air exhaust grille.. * max. 10 VDC / med. 7 VDC / min. 4.5 VDC Correction factors & pressure drop: see Technical info chapter OVERVIEW GRILLES Wooden grilles Aluminium grilles complete installation and user s manual see : http://www.theradiatorfactory.com BON oak BOV oak varnished BNA Alu. natural BBN Beech BBV Beech varnished BNC/XXX Alu. lacquered 1.2 1.3 0.6 0.9 Fully removable internal mechanism for easy cleaning. To ensure perfect adherence of the lacquer coating, an extremely wear-resistant and uv-resistant polyester lacquer coating of the highest quality is used. only in glossy (code 2..) jaga Top Performers 333

CLIMA CANAL OPTIONS THERMOSTAT HEATING / COOLING JAGA CLOCK THERMOSTAT POWER SUPPLY 12.8 The guarantee is only valid if the original Jaga power supply is used. 9.3 2.9 - room regulator for one room - automatic or manual changeover heating/ cooling - display with background lighting - power supply 24 VDc - output control 0-10 VDc - valve contol 0-10 VDc - min. and max. temperature control 8751.050006252,00 CONNECTION SET 24 VDC (0-10 VDC) M24 9 12.5 3.4 Automatic thermostat with day - night and week programme. Activators: auto / continuous. Batteries included 7990.073128,50 CONTROL FOR MULTIPLE ROOMS 6.2 16 8.9 D H DC LO DC ON L L N 5 6 Code H L D 7990.050 9.1 5.3 5.5 7990.051 9.1 7.1 5.5 7990.052 9.1 8.9 5.5 7990.053 12.5 8.3 11.6 - for DIN-rail or wall mounting - safety: ul1310 class 2 - output voltage between 24-28 VDc - input voltage 90-264 VAc -screw connection - LeD display green = on red = Dc low power / short circuit CODE Output Output Watts current A 7990.050 31 1.385,45 7990.051 60 2.5109,30 7990.052 100 4.2 133,00 7990.053 240 10 147,30 Required power = sum of the power consumption of the devices - 24 VDc thermal motor 0-10 V - valve G1/2 x M24 180 - lockshield G1/2 x M24 180 -control 0-10 V - sleeve couplings M24 not included (see page 168) CODE Description 7990.220 180 - G1/2 F / NG 24V 2 Watts 226,60 - control of multiple rooms (max. 4 zones) - control of the heating installation - control of the cooling installation - control of three-way valves - control of zone valves per room - control of fans via 0-10VDc signal - manual adjustment of fan speed - indication of the operating mode by means of LeDs - for DIN rail mounting - to be used with thermostats with potentialfree contacts - (f.e., Jaga clock thermostat 7990.073) - screw connectors 7990.035 474,00 JAGA TWO-WAY VALVE AND MOTOR 230V 1/2" - only for mounting on the distributor, not in the clima canal! - with varistor to protect against overvoltage - with position indicator (open/closed) CODE Description 7990.409 180 - G1/2 F / NG 230V 2 Watts 78,00 7990.411 180 - G3/4 F / NG 230V 2 Watts 88,00 MAX. CABLE LENGTH (in metre) Number of ventilators Min. cable thickness mm 2 2.5 1.5 1 0.75 0.5 1 357.1 214.3 142.9 107.1 71.4 2 178.6 107.1 71.4 53.6 35.7 3 119.0 71.4 47.6 35.7 23.8 4 89.3 53.6 35.7 26.8 17.9 5 71.4 42.9 28.6 21.4 14.3 6 59.5 35.7 23.8 17.9 11.9 7 51.0 30.6 20.4 15.3 10.2 8 44.6 26.8 17.9 13.4 8.9 9 39.7 23.8 15.9 11.9 7.9 10 35.7 21.4 14.3 10.7 7.1 11 32.5 19.5 13.0 9.7 6.5 12 29.8 17.9 11.9 8.9 6.0 13 27.5 16.5 11.0 8.2 5.5 14 25.5 15.3 10.2 7.7 5.1 15 23.8 14.3 9.5 7.1 4.8 16 22.3 13.4 8.9 6.7 4.5 17 21.0 12.6 8.4 6.3 4.2 18 19.8 11.9 7.9 6.0 4.0 19 18.8 11.3 7.5 5.6 3.8 20 17.9 10.7 7.1 5.4 3.6 21 17.0 10.2 6.8 5.1 3.4 Cable length in function of the number of fans (max. tension loss 5%) 334 jaga Top Performers

CLIMA CANAL OPTIONS EMPTY HOUSING To fill open spaces for a continuous installation. CORNER PIECE FEET WITH HEIGHT ADJUSTMENT FOR RAISED FLOORS H L 18 - aluminium grille natural or lacquered - casing with stainless steel grille support - height adjustment: - clima canal 8.5 > 13.3 cm - clima canal hybrid 9.8 > 14.6 cm - fine adjustment for alignment with the finished floor - aluminium or Designo wooden grille - casing with stainless steel grille support - height adjustment: - clima canal 8.5 > 13.3 cm - clima canal hybrid 9.8 > 14.6 cm - fine adjustment for alignment with the finished floor - cover plate Empty housing Clima Canal code height length width grille ORDERING CODE CLCD. 008 072 18 BNA H L BNA BON BBN BNC/XXX BOV BBV 008 072359,20 395,10 108552,60 607,90 144635,50 699,10 180718,40 790,30 Empty housing Clima Canal Hybrid code height length width grille ORDERING CODE CLCD. 010 072 18 BNA H L BNA BON BBN BNC/XXX BOV BBV Corner piece Clima Canal CLCD.008 025 18/BNAAlu. natural 469,70 CLCD.008 025 18/BNC/...Alu. lacquered fill in colour code Corner piece Clima Canal Hybrid CLCD.010 025 18/BNAAlu. natural 489,00 CLCD.010 025 18/BNC/...Alu. lacquered fill in colour code H 18.4 8 8 8 - lacquered in dark grey ral 7024. - easy installation by means of stainless steel spring system - 1 set includes 2 height adjusting controls Number of sets per Clima Canal L 72 = 1 set L 120 = 1 set L 150 = 2 sets L 180 = 2 sets CODE H /set 5209.05070000 5 > 7 cm 50,80 5209.08130000 8 > 13 cm 51,40 5209.13230000 13 > 23 cm 53,60 5209.20300000 20 > 30 cm 55,30 010 072359,20 395,10 108552,60 607,90 144635,50 699,10 180718,40 790,30 MOUNTED MOUTHPIECE FOR AIR SUPPLY CHANNEL height 4 cm x length 9 cm /VEN 56,00 Add /VEN to the code of Clima Canal. Example : CLCM. 008 072 18 /XXX /VEN jaga Top Performers 335

Jaga International - Verbindingslaan z/n - B-3590 Diepenbeek T: +32 11 29 41 16 - F: +32 11 29 41 60 - export@jaga.be your partner: 070912 - JAGA N.V.