About Delta Dore Since 1970, Delta Dore manufactures heating controls for both water based heating and electric heating. Room thermostats, programmable thermostats, controllers, energy-consumption meters.a wide range of solutions to improve comfort at home and make savings on the energy bill. The company designs controls for traditional heating systems like boilers, electric heaters as well as for modern renewable energy based heating systems like heat pumps Thanks to its expertise with hard-wired and wireless communications, Delta Dore provides the end users with adjustable features like control, programming, measure, remote control as well as scalable features in home automation applications for lighting control, opening detection The company has a manufacturing facility of 10 000 square metres in France and offices in Germany, Poland and Spain. Delta Dore supplies plumber s merchants, electrical wholesalers and cooperates with the main European HVAC manufacturers. Solutions perfectly suited for boilers, heat pumps and much more With energy prices and domestic consumption ever on the rise, Delta Dore has strengthened its expertise to offer the end user: - Maximum comfort with a wide range of heating control and programming products - Solutions to reduce the energy usage and then to take part to the CO 2 emission reduction effort. What s different about DELTA DORE? A historical business in manufacturing electronic devices for heating systems An innovative design to offer products: - easy to install and set - easy to understand and use Products that meet the requirements of new and existing dwellings thanks to hard-wired and wireless versions A strong expertise in RF technology and a communication protocol X2D dedicated to home automation applications to ensure: - the reliability of wireless solutions - the interoperability of heating control solutions with further home automation applications. Energy savings in f igures One extra degree could increase the heating bill by 7%. The right programming solution could generate significant savings on the energy bill: - up to 25% saving when used on boilers - up to 7% saving when used on heat pumps.
C O N T E N T S MONEY SAVINGS 4 PRODUCTS FULLY UPGRADABLE 5 APPLICATIONS 6 for boilers > Room thermostat 6 > Programmable thermostat 7 for boilers or heat pumps > 2-zone outdoor temperature compensated controller 8 > Up to 6 zones controller for underfloor heating 9 for heat pumps as boiler back-up > 2-zone outdoor temperature controller 10 > 2-zone controller 11 for heat pumps > Programmable thermostat 12 for solar panels > Solar panel heated-dhw control 13 ADD-ON SOLUTIONS 14 FEATURES 16 3
Money savings L expertise thermique au service de votre projet Chrono-proportional (P.I.) control BENEFIT: Increase the energy efficiency of heating systems by up to 10% Each and every Delta Dore thermostat controls the heating according to the chrono-proportional control method. The chrono-proportional control regularly calculates the duration of the ON and OFF periods in proportion to the difference between the measured and set-point temperatures. This ensures that the required temperature is reached quickly and accurately, without any sudden variations. Programming BENEFIT: Increase the energy efficiency of heating systems by up to 12% Tailored to the lifestyle of the occupants, the programming function automatically lowers the set-point temperature of one or more zones in the dwelling during sleep and away periods each day of the week. Combined with a control function, the programming helps to reduce the total heating consumption. Our combined control and programming products deliver thermal comfort all year round. And because everything is automated, you no longer have to worry about getting too hot or too cold. 4
Products fully upgradable Delta Dore offers a whole range of complementary solutions so that more savings can be made. Consumption metering BENEFIT: Understand energy consumption to start saving View detailed consumption data with our consumption meters and get electricity usage measurements broken down by type (heating, etc.). Wireless magnetic contact combined with heating control BENEFIT: Automatically switch the heating off when the window is open Combine a door/window magnetic contact with a wireless heating control. Heating switches automatically to frost protection mode when the window is opened. It turns back to comfort mode when the window is closed. Telephone remote control BENEFIT: Manage your heat consumption any time, anywhere Use a telephone remote control to manage heating applications. The perfect solution for secondary homes. 5
La Boiler gestion application d énergie pour pompe chaleur réversible Solutions > Programmation > Room thermostat et régulation sur température intérieure Operating principle The thermostat controls the temperature of the home according to the temperature of the room. It can be connected to the oil/gas boiler thermostat input to the circulator pump. Benef its 7% energy saving on the heating bill when using a room thermostat Easy to use High precision control as the temperature sensor can be calibrated to user-specific requirements The solution includes: Hard-wired version - D10: one room unit Wireless version - Radio D10: one room unit and one wireless receiver D10/Radio D10 functions Chrono-proportional (PI) control Indication of room temperature 3 adjustable temperature settings: Comfort Setback Frost Protection Shutdown position Settings can be locked The wireless version solution is perfect for existing installations - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat and receiver (located near the boiler) - Radio range of 100 to 300 metres / 109 yd to 128 yd Boiler Room Thermostat D10 Receiver Wireless room Thermostat Radio D10 Boiler Products Reference no. Add-on solutions D10 6050486 RADIO D10 6050487 Radio MINI COX magnetic contact - ref. 6412254 Telephone remote control TYPHONE 5 SV - ref. 6201048 For more information about add-on solutions, refer to p.14-15 6
Boiler application Solution > Programmable thermostat Operating principle The programmable thermostat controls the temperature of the home according to the temperature of the room. The programming function allows the temperature of the specific zone to be reduced according to occupants requirements to deliver maximum comfort and energy savings. It can be connected to the oil/gas boiler thermostat input to hot water circuit(s) circulator pump(s). Benef its 10-25% saving on the heating bill thanks to the association of control and programming functions The solution includes: Hard-wired version - TYBOX 710/711/713/714: one room unit Wireless version - Radio TYBOX 810/811: one room unit and one wireless receiver Wireless version - Radio TYBOX 820/821: two room units and one wireless receiver Elegant design Large easy-to-read screen Easy to use: the knob provides quick access to all thermostat functions High precision control as the temperature sensor can be calibrated to user-specific requirements Boiler Programmable thermostat TYBOX 713 TYBOX and Radio TYBOX functions Daily or weekly programming by zone Programming by step of quarter hour, half hour or hour Chrono-proportional (PI) control An absence of 1 to 365 days can be programmed Boiler Receiver Radio TYBOX 821 Programmable thermostat Radio TYBOX 821 Programs and settings can be locked The wireless version solution is perfect for existing installations Zone 2 - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat and receiver (located near the boiler) - Radio range of 100 to 300 metres / 109 yd to 128 yd Zone 1 Programmable thermostat Radio TYBOX 821 Products TYBOX 710 - Batteries operated - 1 zone TYBOX 711-230 V - 1 zone TYBOX 713 - Backlit - Batteries operated - 1 zone TYBOX 714 - Backlit - 230 V - 1 zone Radio TYBOX 810-1 zone Radio TYBOX 820-2 zones Radio TYBOX 811 - Backlit - 1 zone Radio TYBOX 821 - Backlit - 2 zones Reference no. 6050478 6050479 6050505 6050501 6050480 6050481 6050503 6050505 Add-on solutions Radio MINI COX magnetic contact - ref. 6412254 Telephone remote control TYPHONE 5 SV - ref. 6201048 For more information about add-on solutions, refer to p.14-15 7
Boiler or heat pump application Solution > 2-zone outdoor temperature compensated controller Operating principle The DELTA 200 controller manages the heating in the home according to the outdoor temperature and to the underfloor system feed temperature. It controls the opening and closing of the underfloor heating mixing valve and activates/deactivates 2 circulator pumps to control the temperature of 2 heating zones in the home. The controller optimises heating within these zones based on the outdoor temperature measured by the sensor. It calculates the exact time required to reach the desired temperature by the scheduled time, regardless of weather conditions outside. The programming function allows the temperature of the specified zones to be reduced according to occupants requirements to deliver maximum comfort and energy savings. The DELTA 200 solution includes: A flush-mounted room unit, a technical unit, an outdoor temperature sensor, an underfloor system feed temperature sensor and a return temperature sensor for the 2 nd zone. Benef its Optimises temperature rises according to the weather conditions for a more energy efficient home Savings on the heating bill thanks to the association of control and programming functions: - 10-25% saving when used on a boiler - 7-10% saving when used on a heat pump Easy to use Possible application for one hot water radiant floor zone and one radiator zone, or two radiator zones. Delta 200 DELTA 200 DELTA 200 functions Daily or weekly programming by zone Programming by step of hour An absence of 1 to 99 days can be programmed Program settings can be locked Adjustment of minimum and maximum water temperatures on both networks Temperature control based on the heating curve Outdoor temperature sensor Sensor Sensor Zone 1 Zone 2 Product Reference no. DELTA 200 6000022 Add-on solutions Consumption meters TYWATT 30 - ref. 6110021 TYWATT TRI - ref. 6110023 For more information about add-on solutions, refer to p.14-15 8
Boiler or heat pump application Solution > Up to 6 zones controller for underfloor heating Operating principle The DELTA 600 controller manages heating room by room according to the temperature of each room. It controls the building s hot water underfloor heating via 6 thermal actuator controls. Each DELTA 600 TH thermostat controls the thermal actuator for the floor assigned to it. DELTA 600 TH programmable room thermostats can be used to change the set-point temperature of each of the zones at any time. Heating is controlled centrally via DELTA 600 COM, allowing the user to switch all the zones to economy mode, for example, from a single point before leaving the house. Benef its Separately controls the temperature of up to 6 underfloor heating zones Savings on the heating bill thanks to the association of control and programming functions: - 10-25% saving when used on a boiler - 7-10% saving when used on a heat pump Easy to use The DELTA 600 solution includes: A DELTA 600 BT technical unit, a DELTA 600 TH programmable room thermostat for each target zone, and a DELTA 600 COM for a central control function. Technical unit DELTA 600 BT DELTA 600 functions Separate weekly programming for each of the rooms or zones Programming by step of hour General control function to centralise all the zones In-built safety function to provide circuit overpressure protection DELTA 600 com Centralised control Boiler DELTA 600 TH Zone 6 Zone 5 Zone 4 Zone 3 Zone 2 Zone 1 Products Reference no. DELTA 600 BT 6000023 DELTA 600 TH 6000024 DELTA 600 COM 6000025 9
Delta 200 La Heat gestion pump d énergie as boiler pour back-up pompe application chaleur non réversible Solutions > > Programmation 2-zone outdoor et temperature régulation sur compensated température controller intérieure Operating principle The T1C-2 DIGIT electronic modular thermostat automatically selects the heat pump or the boiler as the energy source according to the outdoor temperature. Heating in the home is regulated according to the outdoor temperature and to the underfloor system feed temperature. The DELTA 200 controls the opening and closing of the underfloor heating mixing valve and activates/deactivates 2 circulator pumps to control the temperature of 2 heating zones in the home. Benef its The selection of the energy source (heat pump or boiler) is managed automatically according to the outdoor temperature in order to optimise energy consumption Optimises temperature rises according to the weather conditions for a more energy efficient home Energy savings on the heating bill thanks to the association of control and programming functions: - 10-25% saving for boiler operation - 7-25% saving for heat pump operation Easy to use The solution includes: One technical unit (T1C-2 DIGIT), a flush-mounted room unit, a technical unit, an outdoor temperature sensor, an underfloor system feed temperature sensor and a return temperature sensor for the 2 nd zone (DELTA 200). Possible application for one hot water radiant floor zone and one radiator zone or two radiator zones. Technical unit DELTA 200 Functions T1C-2 DIGIT Selects the energy source to be used Sets the minimum set-point temperature to ensure optimum heat pump operation Outdoor temperature sensor Outdoor temperature sensor T1C-2 digit Mixing tank Sensor Sensor Zone 2 DELTA 200 Daily or weekly programming by zone Boiler Zone 1 Programming by step of an hour An absence of 1 to 99 days can be programmed Heat pump Program settings can be locked Adjustment of minimum and maximum water temperatures on both networks Temperature control based on the heating curve Products Reference no. T1C-2 DIGIT 6150031 DELTA 200 6000022 Add-on solutions Outdoor sensor - ref. 6300001 Consumption meters TYWATT 30 - ref. 6110021 TYWATT TRI - ref. 6110023 For more information about add-on solutions, refer to p.14-15 10
Heat pump as boiler back-up application Solution > 2-zone controller Operating principle The T1C-2 DIGIT electronic modular thermostat automatically selects the heat pump or the boiler as the energy source according to the outdoor temperature. Heating in the home is regulated according to the temperature of the room. The programmable thermostats Radio TYBOX control 2 heating zones according to the temperature of each zone by activating/deactivating the circulator pumps. Benef its The selection of the energy source (heat pump or boiler) is managed automatically according to the outdoor temperature to optimise energy consumption Energy savings on the heating bill thanks to the association of control and programming functions: - 10-25% saving for boiler operation - 7-10% saving for heat pump operation Easy to use: the programmable thermostat knob provides quick access to all thermostat functions High precision control as the indoor temperature sensor can be calibrated to user-specific requirements The solution includes: One technical unit (T1C-2 DIGIT), two wireless room units and one 2-channel wireless receiver (Radio TYBOX 821). T1C-2 digit Receiver Radio TYBOX 821 Functions T1C-2 DIGIT Selects the energy source to be used Sets the minimum set-point temperature to ensure optimum heat pump operation Radio TYBOX 820/821 Weekly programming by zone Outdoor temperature sensor Heat pump Boiler Mixing tank Programmable thermostat Radio TYBOX 821 Programmable thermostat Radio TYBOX 821 Zone 1 Zone 2 Chrono-proportional control Programming by step of quarter hour, half hour or hour An absence of 1 to 365 days can be programmed No unsightly cables between the thermostat and receiver (located near the boiler) Radio range of 100 to 300 metres / 109 yd to 128 yd Programs and settings can be locked Products T1C-2 DIGIT Radio TYBOX 820 Radio TYBOX 821 - Backlit Reference no. 6150031 6050481 6050505 Add-on solutions Outdoor sensor - ref. 6300001 Consumption meters TYWATT 30 - ref. 6110021 TYWATT TRI - ref. 6110023 Radio MINI COX magnetic contact - ref. 6412254 Telephone remote control TYPHONE 5 SV - ref. 6201048 For more information about add-on solutions, refer to p.14-15 11
Heat pump application Solution > Programmable thermostat Operating principle The programmable thermostat controls the temperature of the home in heating or cooling mode according to the temperature of the room (underfloor heating/cooling). The programming function allows the temperature of the specified zone to be reduced according to occupants requirements to deliver maximum comfort and energy savings. The programmable thermostat can control a heat pump using one of 2 types of connection: - in summer/winter mode via the change-over function and the heat pump s thermostat input - via the 2 thermostat inputs (heat mode or cooling mode). The solution includes: Hard-wired version - TYBOX 712/715: one room unit Wireless version - Radio TYBOX 812/813: one room unit and one wireless receiver Benef its Elegant design Control a heat pump using heating or cooling mode TYBOX 715 Radio TYBOX 813 7-10% saving on the energy bill thanks to the association of control and programming function Easy to use: the knob provides quick access to all thermostat functions High precision control as the temperature sensor can be calibrated to user-specific requirements Receiver Radio TYBOX 813 Heat pump TYBOX 712 and Radio TYBOX 812 functions Heat pump Weekly programming by zone Chrono-proportional (PI) control Heat pump protection with time base that can be set from 30 to 60 minutes Programming by step of quarter hour,half hour or hour An absence of 1 to 365 days can be programmed Programs and settings can be locked The wireless version solution is perfect for existing installations - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat and receiver (located near the boiler) - Radio range of 100 to 300 metres / 109 yd to 128 yd Products TYBOX 712 TYBOX 715 - Backlit Radio TYBOX 812 Radio TYBOX 813 - Backlit Reference no. 6050484 6050502 6050485 6050504 Add-on solutions Radio MINI COX magnetic contact - ref. 6412254 Telephone remote control TYPHONE 5 SV - ref. 6201048 For more information about add-on solutions, refer to p.14-15 12
Solar panel application Solution > Solar panel heated-dhw control Operating principle The electronic modular thermostat controls the water temperature in the circuit. It controls the circulation of the heat transfer fluid based on the difference in temperature between the water heater and the solar panel. For example: If the temperature of the solar panel goes 10 C above that of the water heater, the thermostat activates the circulator so that the heat transfer fluid can warm up the water heater. If the temperature of the solar panel goes down to 2 C above that of the solar water heater, the thermostat stops the circulator. The T1D DIGIT solution includes: One technical unit T1D DIGIT functions Frost protection function ensures circulation of heat transfer fluid when the outdoor temperature falls below a set threshold Setting of two difference thresholds (large and small difference) Safety temperature setting (0 to 150 C) Display of the 3 measured temperatures 3 sensor inputs (solar panel, water heater and outdoor temperature) Temperature sensor 1 The solar panel Storage tank T1D DIGIT DHW Sensor 2 Thermostatic mixing valve Electric resistance Solar cylinder Products References no. Add-on solutions T1D DIGIT 6050032 Underfloor or piping sensor - ref. 6300002 For more information about add-on solutions, refer to p.14-15 13
ACCESSOIRES ADD-ON SOLUTIONS Electricity consumption meters Consumption meters measure electricity consumption for heating, domestic hot water, etc. and display usage in kwh. Benefit: By providing a detailed view of consumption habits, these metres make users more aware of how resources are being used and how energy bills can be reduced. Reference no. 6110021 TYWATT 30 Consumption meter for a single-phase installation Allows users to measure the kwh consumption of all or part of the electrical system (heating, domestic hot water, heat pump, etc.) Compatible with an electronic meter or an electromechanical meter Displays the total KWh consumption by rate period Double meter (one continuous and one that can be initialized) Displays the maximum average power reached Reference no. 6110023 TYWATT TRI Consumption meter for three-phase installations Allows users to measure the kwh consumption of all or part of the electrical system (heating, domestic hot water, heat pump, etc.) Compatible with all types of electronic and electromechanical meters Displays the total KWh consumption by rate period Double meter (one continuous and one that can be initialized) Displays the maximum average power reached Wireless magnetic contact Door/window magnetic contact combined with wireless heating control. Benefit: Prevents heat loss to deliver more energy savings. MINI COX Installed on windows and doorways, this mini magnetic contact reduces energy consumption by switching the heating zone to frost protection mode when a window is opened. It turns back to the preset level when the window is closed. Reference no. 6412254 14
Telephone remote controls Using a telephone remote control, heating applications can be controlled and settings may be changed even when away from home. Benefit: Heat consumption can be managed any time, anywhere. TYPHONE 2 SV Reference no. 6201022 TYPHONE 3 SV TYPHONE 2 SV / TYPHONE 3 SV Voice synthesis PSTN telephone remote control for heating and DHW Can be used with a telephone answering machine Access code protection On/off or timer control of 2 (2 SV) or 3 (3 SV) outputs for different applications (heating, domestic hot water tank, lighting) Reference no. 6201020 TYPHONE 5 SV GSM GSM telephone remote control for heating & DHW On/Off control for different applications (heating, domestic hot water tank, lighting) Can be associated to a wireless heating control to allow the remote control of heating modes: temperature settings can be changed (Comfort, Backset, Frost protection, Auto) Reference no. 6201048 15
FEATURES ACCESSOIRES Digital room thermostats D10 Radio D10 Power supply: 2 x 1.5V AAA batteries (supplied) One 2 A/230 V change-over dry contact Control range 5 to 30 C Dimensions: H 80 x L 80 x D 23 mm Transmitter power supply: 2 x 1.5V AAA batteries (supplied) Receiver power supply: 230 V/50 Hz One 5 A/230 V dry contact Control range 5 to 30 C Radio frequency 868 MHz Transmitter dimensions: H 80 x L 80 x D 23 mm Receiver dimensions: H170 x L 54 x D 25 mm 1-zone hard-wired programmable thermostats for boilers or electric heating TYBOX 710/713 TYBOX 711/714 Power supply: 2 x 1.5V AAA batteries (supplied) One 2 A dry contact Control range 5 to 30 C Dimensions: H 104 x L 80 x D 35 mm Power supply: 230 V/50 Hz One 2 A dry contact Control range 5 to 30 C Dimensions: H 104 x L 80 x D 35 mm 1- or 2-zone wireless programmable thermostats for boilers or electric heating Radio TYBOX 810/811 Radio TYBOX 820/821 Transmitter power supply: 2 x 1.5V AAA batteries (supplied) Receiver power supply: 230 V/50 Hz One 5 A/230 V dry contact Control range 5 to 30 C Radio frequency 868 MHz Transmitter dimensions: H 104 x L 80 x D 37 mm Receiver dimensions: H 100 x L 54 x D 24 mm Transmitter power supply: 2 x 1.5V AAA batteries (supplied) Receiver power supply: 230 V/50 Hz Two 5 A/230 V dry contacts Control range 5 to 30 C Radio frequency 868 MHz Transmitter dimensions: H 104 x L 80 x D 37 mm Receiver dimensions: H 100 x L 54 x D 24 mm 16
2-zone outdoor temperature compensated controller Room unit Power supply via bus link to technical unit Control range 5 to 30 C Dimensions: H 95 x L 85 x D 16 mm DELTA 200 Technical unit Power supply: 230 V/ 50 Hz One 2 A contact boiler control output One 3-way valve output Two 2 A contact circulator outputs Supplied with outdoor sensor, feed sensor and water return sensor Dimensions: H 80 x L 230 x D 70 mm Up to 6 underfloor heating zones controller DELTA 600 HT Thermostat Power supply: 2 x 1.5V AAA batteries (supplied with each product) Control range 5 to 30 C Dimensions: H 121 x L 94 x D 31 mm DELTA 600 DELTA 600 COM Programmable room thermostat DELTA 600 BT Technical unit Power supply: 2 x 1.5V AAA batteries (supplied with each product) Dimensions: H 121 x L 94 x D 31 mm Power supply: 230 V/50 Hz Six 5 A contact valve control outputs One 1 A contact control output for burner or circulator Dimensions: H 80 x L 230 x D 70 mm 17
FEATURES Programmable thermostats for reversible and non-reversible heat pumps TYBOX 712/715 Radio TYBOX 812/813 Power supply: 2 x 1.5V AAA batteries (supplied) One 2 A contact output One 2 A change-over contact output Control range 5 to 30 C Control time base can be set at 30/45/60 minutes Dimensions: H 104 x L 80 x D 35 mm Transmitter power supply: 2 x 1.5V AAA batteries (supplied) Receiver power supply: 230 V/50 Hz Two 3 A conf igurable dry contact outputs Control range 5 to 30 C Control time base can be set at 30/45/60 minutes Radio frequency 868 MHz Transmitter dimensions: H 104 x L 80 x D 37 mm Receiver dimensions: H 120 x L 54 x D 25 mm Modular thermostats Multi-application: control of the temperature and monitoring T1C-2 DIGIT Power supply: 230 V/50 Hz 3 control range -10 to 90 C Accuracy temperature 0,2 to 2 C One 5 A conf igurable dry contact output Dimensions: H 84 x L 53 x D 59 mm Solar panel heated-dhw control T1D DIGIT Power supply: 230 V/50 Hz 3 control range -10 to 90 C One 5 A conf igurable dry contact output Accuracy temperature 0,2 to 2 C Dimensions: H 84 x L 53 x D 59 mm 18
Ducted air conditioning system Solution > Up to 6 zones controller Operating principle The radio DELTA 630 solution controls and programs the temperature of the home in heating or cooling mode according to the temperature of the room Each DELTA 630 TH room thermostat controls the motorised register of the zone or room assigned to it. It can be used to change the set-point temperature locally at any time. The DELTA 630 MASTER programmer manages the programming of each of the zones based on 2 temperature settings (Comfort or Setback) The Radio Pack DELTA 630 solution includes : One technical unit (DELTA 630 BT), 4 wireless room thermostats to control the first 4 registers (DELTA 630 TH), one wireless programmer (DELTA 630 Master) and one limit sensor. Benefits 10-25% saving on the heating bill thanks to the association of control and programming functions Elegant design Large Easy-to-read screen Easy to use : the knob provides quick access to all thermostat functions Functions Controls up to 6 register-equipped zones by time and temperature Daily or weekly centralised programming by zone The wireless version solution is perfect for existing installations : - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat and technical unit - Radio range of 100 to 300 metres 109 yd to 328 yd Products Pack DELTA 630 - Backlit DELTA 630 TH - Backlit DELTA 630 MASTER - Backlit DELTA 630 BT Reference no. 6050512 6050513 6050514 6050515
Features DELTA 630 MASTER programmer Transmitter power supply: 2 x 1.5V AAA batteries (supplied) One Change-Over command Radio frequency 868 MHz Dimensions: H 104 x L 80 x D 35 mm DELTA 630 TH room thermostat Transmitter power supply: 2 x 1.5V AAA batteries (supplied) Radio frequency 868 MHz Dimensions: H 80 x L 80 x D 23 mm DELTA 630 BT technical unit Includes one change-over temperature sensor which checks the AC system s output temperature to activate or deactivate the fan whenever the mode changes (heating/cooling). Power supply 230 V Three (non-powered 5 A 230 V), NO contact outputs : changeover, interior unit One register power supply input Six 230V / 24 V DC / 12 V DC register contact outputs Dimensions: H 130 x L 180 x D 60 mm
Reversible AC split system application Solution > Interface for infrared control of reversible air conditioning systems Operating principle The Radio D30 is an infrared interface that controls reversible mode air conditioning systems. It can record up to 22 remote control screens for AC split systems. It gives access to three modes: heating / cooling and fan mode. And local overrides can be done: Comfort heating, Setback heating, comfort heating, fan speed... Benefits The solution includes : one room unit. The thermostat operates by copying the infrared signals of the original Ac split system remote controls and can then manage a maximum number of existing and further split AC systems without updating the product. Several Radio D30 may be associated to a wireless programmer to provide a programming function. Radio D30 Features Power supply: 230V / 50Hz Radio frequency 868 MHz Wireless range 150 to 200 metres / 164 yd to 218 yd Dimensions: H 80 x L 80 x D 23 mm AC split system Heat pump Products Radio D30 Reference no. 6203001
Electric heating application Solution > Programmers for electric heating systems with pilot wire Operating principle The DRIVER programmer controls electric heaters based on 2 temperature settings (Comfort, Setback). The Comfort temperature is set on the heater. The Setback temperature is 3.5 below the set Comfort temperature. The program is customised according to the occupants lifestyle. During the night or when occupants are out, the programmer will lower the heating in the house to reduce unnecessary energy consumption. Depending on the model, it can manage the programming of up to 3 separate zones. A choice of 3 technologies are available, depending on the installation: - Wireless/Pilot Wire, perfectly suited for existing dwellings - Powerline carrier/pilot Wire, perfectly suited for existing dwellings - Pilot Wire, ideal for new dwellings Benefits 10-25% saving on the heating bill thanks to the programming function Easy to use : the knob provides quick access to all thermostat functions Functions Daily or weekly programming by zone Timer-controlled zone override function, from 15 min to 72 hours Permanent override function using the knob Absence of 1 to 365 days can be programmed Wireless programmer: Radio DRIVER Features Radio Driver Power supplied by 2 AAA batteries (supplied) 2-year battery life Radio frequency 868 MHz Wireless range 150 to 200 metres / 164 yd to 218 yd Dimensions: H 104 x L 80 x D 35 mm RF 660 FP wireless receiver 6-order pilot wire outputs Set-point level display Dimensions: H 102.5 x L 54 x D 19 mm (Antenna excl.)
PLC programmer : DRIVER CPL Features PLC DRIVER 230 V power supply No filter at the head of the system Dimensions: H 128 x L 85 x D 31 mm TC 51089 receivers 6-order pilot wire outputs Set-point level display Dimensions: H 170 x L 50 x D 25 mm Programmer : DRIVER Features 230 V power supply 6-order pilot wire outputs Dimensions: H 104 x L 80 x D 35 mm Products Radio DRIVER 610-1 zone Radio DRIVER 620-2 zones Radio DRIVER 630 3 zones RF 660 FP receivers PLC DRIVER 210-1 zone PLC DRIVER 220-2 zones PLC DRIVER 230-3 zones TC 51089 receivers DRIVER 610-1 zone DRIVER 620 2 zones Reference no. 6051137 6051138 6051139 6050508 6051135 6051136 6051134 6051140 6050506 6050507
Electric heating application Solution > Zone control by time and temperature Operating principle The programmable thermostat controls the temperature by controlling the electric heaters in one zone. It sends commands to the receivers through RF technology. The programming function allows to reduce the temperature of the room according to occupants requirements to deliver maximum comfort and energy savings. Benefits 10-25% saving on heating bill thanks to the association of control and programming functions Elegant design Large Easy-to-read screen Easy to use : the knob provides quick access to all thermostat functions High precision control as the temperature sensor can be calibrated to user-specific requirements The solution includes: One wireless room unit (Radio TYBOX) by zone and one wireless receiver (RF 642) for each electric heater. Programmable thermostat Radio TYBOX 801 Functions Daily or weekly programming Programming by step of quarter hour, half hour or hour Chrono-proportional (PI) control An absence of 1 to 365 days can be programmed Programs and settings can be locked The wireless version solution is perfect for existing installations - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat programmable and receiver - Radio range of 100 to 300 metres 109 yd to 328 yd Products Radio TYBOX 800 Radio TYBOX 801 - Backlit Receiver RF642 Reference no. 6050509 6050511 6351081
Features Room unit (transmitter only) Radio frequency 868 MHz Power supplied by 2 AAA batteries (supplied) Dimensions: H 104 x L 80 x D 35 mm RF 642 receivers: 16 A wireless receiver Radio frequency 868 MHz 16 A resistive contact output Dimensions: H 120 x L 54 x D 25
Electric heating application Solution > Up to 3 zones centralised control by time and temperature Operating principle The Radio DRIVER wireless programmer centrally programmes the electric heating by zone for up to 3 zones/rooms. Each Radio D10 wireless room thermostat controls the temperature of the corresponding room by sending information to the receivers associated with the electric heaters within the zone. Benefits 10-25% saving on the heating bill thanks to the association of control and programming functions Elegant design Large Easy-to-read screen Easy to use : the knob provides quick access to all thermostat functions Centralised programming for up to 3 zones The solution includes: One wireless programmer room unit (Radio DRIVER), one wireless receiver (RF 642) for each electric heater, and one wireless room thermostat (Radio D10) for each zone Functions Radio Driver Daily or weekly programming by zone Programming by step of quarter hour, half hour or hour Timer-controlled zone override function, from 15 min to 72 hours Permanent override function using the knob An absence of 1 to 365 days can be programmed Radio range of 150 to 200 metres / 164 yd to 218 yd 2-zone programmer Radio DRIVER 620 Radio D10 Chrono-proportional (PI) control 3 adjustable temperature settings: Comfort - Setback - Frost Protection Shutdown position Settings can be locked The wireless solution is perfect for existing installations - Quick to install - Blends in with the home interior - No unsightly cables between the programmable thermostat and receiver - Radio range of 100 to 300 metres 109 yd to 328 yd Products Radio DRIVER 610 1 zones Radio DRIVER 620 2 zones Radio DRIVER 630 3 zones Radio D10 Receiver RF642 Reference no. 6051137 6051138 6051139 6050487 6351081
Features Radio Driver 630 / 620 / 610 Power supplied by 2 AAA batteries (supplied) 2-year battery life Radio frequency 868 MHz Dimensions: H 104 x L 80 x D 35 mm Radio D10 Transmitter power supply : 2 x 1.5V AAA batteries (supplied) Receiver power supply: 230 V/50 Hz One 5 A/230 V dry contact Control range 5 to 30 C Radio frequency 868 MHz Transmitter dimensions: H 80 x L 80 x D 23 mm RF 642 receivers : 16 A wireless receiver Radio frequency 868 MHz 16 A resistive contact output Dimensions: H 120 x L 54 x D 25
Solid fuel boiler application: wood, wood pellets, coal Solution > Controller Operating principle The DELTA 40/42 RF controller controls the temperature of the heating water circuit. It activates/deactivates the circulator pump based on the temperature measured at the boiler's water outlet When associated with a room thermostat, it also controls the heating based on the room temperature. Functions Allows the control of the heating circulator pump according to the temperature measured at the boiler water outlet. Controller shutdown and frost protection functions. The room temperature can be adjusted via a room thermostat placed in the room. It can be wired directly to a DELTA 40 controller or connected wirelessly to a DELTA 42 controller. The solution includes : DELTA 40: One controller DELTA 42 RF: One controller and one wireless room thermostat DELTA 42 RF controller + Wireless room thermostat Chrono-proportional (PI) control 3 adjustable temperature settings : Comfort - Setback - Frost Protection Shutdown position Settings can be locked The wireless version solution is perfect for existing installations - Quick to install. Blends in with the home interior. No unsightly cables between the thermostat and the controller - Radio range of 100 to 300 metres 109 yd to 328 yd Products DELTA 40 DELTA 42 RF With wireless room thermostat (supplied) Reference no. 6000026 6000028 Add-on solution Hard-wired room thermostat
Features DELTA 40 230 V, 50 Hz power supply, pre-wired One 5 A 230 V relay output (heating circulator pump) One heating temperature sensor input (sensor supplied) One hard-wired thermostat input (thermostat not supplied) Dimensions : H 135 x L 143 x D 45 mm DELTA 42 Wireless controller 230 V, 50 Hz power supply (pre-wired) One 5 A 230 V relay output (heating circulator pump) One heating sensor input (sensor supplied) Dimensions : H 135 x L 143 x D 45 mm Wireless room thermostat Power supply: 2 x 1.5 V AAA alkaline batteries (supplied) 2-year battery life Radio frequency 868 MHz
Solid fuel boiler with fan application: wood, wood pellets, coal Solution > Controller Operating principle The DELTA 41/43 RF controller controls the temperature of the heating water circuit and the domestic hot water. It activates/deactivates the circulator pumps based on the temperature measured at the boiler's water outlet It increases/decreases the air supply to the boiler by controlling the fan. When associated with a programmable thermostat, it also controls and programs the heating based on the room temperature. The solution includes: DELTA 41: One controller DELTA 43 RF: One controller and one wireless programmable thermostat Functions The controller allows the control of the heating circulator pump according to the temperature measured at the boiler water outlet. It controls the circulator pump of the DHW. Controller shutdown and frost protection function. When associated with a programmable thermostat placed in the user s chosen location, it adjusts and programs the room temperature. DELTA 43 RF controller + Wireless programmable thermostat Daily or weekly programming by zone Programming by step of quarter hour, half hour or hour Chrono-proportional (PI) control Programs and settings can be locked The wireless version solution is perfect for existing installations : - Quick to install. Blends in with the home interior. No unsightly cables between the programmable thermostat and the controller - Radio range of 100 to 300 metres 109 yd to 328 yd Products DELTA 41 DELTA 43 RF With wireless programmable thermostat (supplied) Reference no. 6000027 6000029 Add-on solution. Hard-wired room thermostat. Hard-wired programmable thermostat
Features DELTA 41 230 V, 50 Hz power supply, pre-wired One 5 A 230 V relay outputs (heating circulator pump, DHW circulator pump, fan) Two sensor inputs: heating and DHW (heating sensor supplied) One hard-wired thermostat input (thermostat not supplied)) Dimensions : H 135 x L 143 x D 45 mm DELTA 43 Wireless controller 230 V, 50 Hz power supply, pre-wired Three 5 A 230 V relay outputs (heating circulator pump, DHW circulator pump, fan) Two sensor inputs: heating and DHW (heating sensor supplied) Dimensions : H 135 x L 143 x D 45 mm Wireless programmable thermostat Power supply: 2 x 1.5 V AAA batteries (supplied) Battery life: 2 years Radio frequency 868 MHz