1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable



Similar documents
2178-S Fiber Optic Splice Case

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Wall Mounted Products

3M Fiber Optic Splice Closure 2178-LS Series with Gasket

Complete System Shelter

4 Small Cables Sealing Kit: Wrap Style

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Reasons for reissue are in Section 6, REVISION SUMMARY.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Toroidal Conductivity Sensor

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Fiber Optic Splice Closure. 1.0 General Product Information. FOSC 600-abc-dd-e-fgh

Round Housing with Side Ports

RayClic Connection System Installation Instructions

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

XL PREMIUM OIL COOLER KIT

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Machine needle shut-off nozzle type-a

RayClic Connection System Installation Instructions

with installation dynafact boost GAUGE this manual is for use with systems

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

5800 Temperature Sensor Cable Assembly

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x mm)

INSTALLATION INSTRUCTIONS FOR VW MK5

Optical cable connection for external flash

theory FTHPL, T-RATED

Standard Sleep Pod Side Entry Assembly Instructions

Installation instruction CASAFLEX - Connecting piece DN 100

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

NELSON HEAT TRACING SYSTEMS

Installation Manual. BYD Wall-mounted AC Charging Box

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Flue Installation. High Efficiency Condensing Boilers

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Installation Instructions

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Model CS 64 Mini-DIN Cable and Adaptor

STEERING SYSTEM - POWER

CABLE ACCESSORIES kv

ECM-D70T / ECM-D70T1.5

Post Mount Light Installation*

Installation Instructions For Slider Casement Air Conditioners

I NTERFACE CABLE ADAPTER MODULE

AM/FM ANTENNA RELOCATION KIT

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Control Box Wiring For PRSstandard Tool

Operating Instructions

Directory chapter 04

DIY Y6. Build Manual V.A 2014

Important Information

HOW TO BUILD A LOU-VEE-AIRCAR

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE


EH-20 20m antenna. By VE3RGW

SunMor SM-V30 Solar Water Heater Installation Manual

Drive shaft, servicing

Linear Luminaire with LED Series EXLUX 6402/2

Duct Humidity Transmitter

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Installation Instructions

Beautifully Traditional

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

VOYAGER 570G. 744A Sprayer Control

Cylinder head gasket, replacement

Step by step guide to installing your own Ku Band satellite dish

Heater Replacement Procedure

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Expanding a 40-Type Cabinet

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Tipping Bucket Rain Gauge Models 6011-A 6011-B

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Submersion/Insertion Toroidal Sensor

Front axle components, overview

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Installation Instructions

Electric Rotary Actuator - On/Off or programmable control actuator

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Traditional Sonar and DSI Sonar Installation

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Transcription:

TS-GPJ02VM 1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is: aerial and wall-mounting. The ambient temperature ranges from -40 to 65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (LxWxH) 280x200x90 (mm) Weight (excluding outside box) Number of inlet/outlet ports Diameter of fiber cable Capacity of FOSC 1200g-1500g max. 4 pieces Φ8 Φ14 (mm) Bunchy: 6 96 (Cores) 2.2 Main components No. Name of components Quantity Usage Remarks 1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable 3 Fiber optic splice tray (FOST) 4 Integrated seal fitting max. 4 pieces (bunchy) and FOST Fixing heat shrinkable protective sleeve and holding fibers 1 set Sealing between FOSC cover and FOSC bottom 5 Port plug 2 pieces Sealing empty ports 6 Earthing deriving 1 set Deriving metallic components of fiber cable in FOSC for earthing Internal diameter: 205x146 (mm) Internal diameter: 205x146 (mm) Suitable for: Bunchy:6,12,24(cores) Configuation as per requirement. device connection. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 1

2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Protecting fiber splices Configuration as per capacity 2 Nylon tie Fixing fiber with protective coat Configuration as per capacity 3 Seal tape 1 roll Enlarging diameter of fiber cable which fits in with seal Configuration as per specification fitting 4 Hanging hook 1 set For aerial use Configuration as per requirement 5 Fixing device 1 set Configuration as per requirement 6 Earthing wire 1 piece Putting through between earthing devices To put through while required 7 Abrasive cloth 1 piece Scratching fiber cable 8 Labeling paper 1 piece Labeling fiber 9 Special wrench 1 piece Fixing octagonal nut (plastic) 10 Buffer tube To be Hitched to fibers and fixed decided with FOST, managing buffer by customers 11 Desiccant 1 bag Put into FOSC before sealing for desiccanting air. Configuration as per requirement Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 2

3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Usage Scotch tape Ethyl alcohol Gauze Labeling, temporarily fixing Cleaning Cleaning 3.2 Special tools (to be provided by operator) Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fibers Strip off protective coat of fiber cable Assembling FOSC 3.3 Universal tools (to be provided by operator) Name of tools Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Usage and specification Measuring fiber cable Cutting fiber cable Take off protective coat of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Usage and specification Fusion Splicing Machine OT DR Provisional splicing tools Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off protective coats of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix reinforced core and fiber cable 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Install FOSC housing Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 4

5. The process of installing FOSC 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared inside the package. 5.1.3 Open the closure by demounting the fixing bolt (5 pieces) of the housing, then succeed in opening the closure. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 5

Fixing bolt for housing Inlet/outlet tube Octagonal nut Integrated seal fitting Pressboad reinforced core FOST cover FOSC cover FOSC bottom wall-mounting FOSC bottom FOSC cover Fixing bolt for housing/hanging hook wall-mounting Fixing bolt for housing/hanging hook Drawing 1 5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 1. Fiber cable in 70mm length: the distance from seal fitting to fiber cable pressboard 2. Fiber cable in 1720mm length: it is used to be winded and spliced after stripping. 3. Fiber with protective coat in 120mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray). 4. Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers 5.2.2 See Drawing 2 Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customer according to installation requirement. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 6

2.1720mm length of protective coat of fiber cable to be stripped off 1. Fixing length of fiber cable inside FOSC Fiber cable 70mm 3.120mm length of fiber with protective coat 4.1600mm length of protective coat of fiber to be stripped off Drawing 2 5.3 Step Three Strip off fiber protective coat of fiber cable and fiber 5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to strip off all the protective coat of fiber cable at one time, strip it off section by section to avoid fiber breakage. Temp. locating mark Stripping terminal fiber cable Inlet terminal fiber cable Cutter Drawing 3 5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber. 5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core. Meanwhile, get rid of the stuffing to separate fiber and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber temporarily by adhesive tape. 5.4.2 This FOSC is provided with 2 inlet/outlet tubes, each of which suit for 1 piece of fiber cable with max. diameter ф14mm or 2 pieces of fiber cable with max. diameter ф11mm. The corresponding port plug could be taken out according to number of fiber cable actually required. The max. number of fiber cables with diameter ф11mm to be installed is 4. 5.4.3 Reserve reinforced core in 30mm length and cut off the unnecessary ones. 5.4.4 See Drawing 4 Important Issues: Cut off reinforced core with a special cutting plier. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 7

Adhesive tape Seal tape Insulation tape Fiber cable Reinforced core Fiber Fiber with protective coat (bunchy or ribbon) Drawing 4 5.5 Step Five - Fix reinforced core and fiber cable 5.5.1 After deciding number of fiber cable inlet/outlet, demount the nut and gasket of the alcohol. corresponding inlet/outlet tube. Insert them into fiber cables in sequence, which are to be inserted into inlet/outlet tube then. 5.5.2 Fix fiber cable to fixing device of fiber cable (while diameter of fiber cable is small, enlarge the diameter with insulation tape), then fix the reinforced core to the fixing device of the reinforced core. 5.5.3 Push the first gasket into inlet/outlet tube, then enlarge the diameter of fiber cable with seal tape (to fit in with internal diameter of inlet/outlet tube). Then push the second gasket and the seal tape into inlet/outlet tube, which is to be tightened with octagonal nut. 5.5.4 See Drawing 5 Important issues: before the seal tape is used for enlarging the diameter of fiber cable, it should be scratched and to be cleaned with abrasive cloth and ethyl Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 8

Adhesive tape Fiber reinforced core Pressboard (double) Inlet/outlet tube Gasket (double) Octagonal nut Fiber cable Fiber cable Octagonal nut Gasket (single) Seal tape Reinforced core Earthing device Pressboard (single) Drawing 5 FOST cover Grommet FOST Integrated seal fitting FOSC bottom Fiber with protective coat 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber. 5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. ( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 9

5.7.2 see Drawing 6 Important issue: pay attention to the twist and bend of fiber. Fixing slot of he at shrinkable prote ctive slee ve (bunc hy) Grommet FOST Fiber Nylon tie Fibe r with prote ctive coat Fibe r with prote ctive coat Fiber He at shr inkable prote ctive sleeve Drawing 6 5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with protective coat are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 Check whether the internal tighteners and bolt of reinforced core is well tightened 5.8.4 Check whether integrated seal fitting is installed neatly and smoothly without any breakage. If not, level it up with seal tape. 5.8.5 See Drawing 7. Important issues: If any problems occur, they should be solved right away. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 10

Fiber with protective coat Pressboard (double) Inlet/outlet tube Octagonal nut Fiber cable Fiber cable Pressboard (single) wall-mounting reinforced core Earthing device FOSC cover FOST Grommet FOST cover Integrated seal fitting Fiber Grommet FOST Heat shrinkable protective sleeve Nylon tie Drawing 7 5.9 Step Nine Install FOSC housing 5.9.1 Tighten fixing bolts of the housing 5.9.2 Tighten octagonal nuts 5.9.3 Either wall mounting or aerial mounting is possible according to the actual installation requirement. 1 Wall mounting application: fixing device for wall mounting should be installed at the bottom of FOSC, which is to be fixed with plastic intumescent screw and bolts. 2 Aerial mounting application: fix hanging hook on the wall. 5.9.3. See drawing 8 Important issues: 1. Clean the housing 2. Tighten bolts in sequence. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 11

FOSC cover Fixing bolt for housing/hanging hook wall-mounting Fixing bolt for housing/hanging hook Fixing bolt for housing Fixing bolt for housing wall-mounting Fixing bolt for housing Drawing 8 Inlet/outlet tube Octagonal nut wall-mounting 6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Inspecting type Routine test (Before leaving Type test factory) full Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 12

Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Punching Impact Bending Torsion Temperature circle Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa ± 5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. At least 3 sets sampled each time At least 3 sets sampled each time Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 13

Voltage resistance strength Isolating resistance After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. Tel: 213 21 869692,93, 860819, 869754 021 869754, 55,56 fax: 213 21 860814 Page 14