New: Standard Safety Light Grille. High-Speed Doors



Similar documents
Up-And-Over Garage Doors

High-Speed Doors. New high-speed sectional door HS 5015 Acoustic H with 31 db acoustic insulation. For optimised material flow and improved efficiency

Collective Garage Doors ET 500 and ST 500

Roller Garage Door RollMatic

High-speed spiral doors for deep-freeze applications. TK Series

MODEL HSR-007 Direct Drive Rolling Steel

Confort 26. Sliding Systems. Sapa Building System

High-speed folding doors. F Series

Plaisance 24. Sliding Systems. Sapa Building System

RollMatic Roller Garage Door More free space in the garage with innovative Hörmann technology

Installation Detailed installation instructions are provided which should be strictly followed.

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

With mechanical door security kit. Patented! SupraMatic H Garage Door Operator. Ideal for Multiple Dwellings with Collective Garages

Confort 160. Sliding Systems. Sapa Building System

Crawford 220 Folding door. Product datasheet

HERZ-Thermal Actuators

HVAC air curtains. Type InduAir

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Plaisance 50. Windows and doors. Sapa Building System

Morgue refrigeration unit

Glass partitions SFB 3074

SCHOTT PYRANOVA Planline System

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

SL30-ISO PROFILE SYSTEM

Aluminium Standard. Technical Data. Included in delivery

Avantis 75. Windows & Doors. Sapa Building System

Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter

Terminal Boxes Series 8146

Operator Accessories NEW

ED 100LE ED 250LE. Low energy swing door operators

garage door operators

Rolling shutters and rolling grilles in aluminium or steel

Garage Sectional Doors

Technical product description High-speed roll-up door Machine protection. For internal use only

NEW. Sectional Garage Door Range

MagTek A. Aluminium Manual Attack Resistant Doors

Brochure EX

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Unbeatable energy efficient glass curtain wall system

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Fire Resistant Systems

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

iku windows the intelligent self cleaning window AUTOMATIC system

Linkeo 19" freestanding cabinets

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

Guide to Safety Edge Systems

STANDARD FOR NON-FIRE RATED ROLLING DOORS

Residential Garage Door Terminology

Sliding and Folding Door Fittings Sliding Door Accessories

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

BLADE S-MAX Cabinet for Blade Server

Series 8146/5-V37 and Series 8150/5-V37

Series 456 Commercial Awning Window

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

RPV - RP - RA air handling units

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

SERVER ROOM CABINET INSTALLATION CONCEPTS

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Loss Prevention Standard

REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. Building Solutions Automotive Industry

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

TARIFF CODE and updates standard

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Technical data UNIBLOCK UBSF

TELESCOPE Motorized Lighting Suspension

MultiPost-AP anchorage device

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

SECTIONAL GARAGE DOORS FOUR DIMENSIONS OF QUALITY

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

K17.12 Door closers K17. Doors

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Coldrooms designed for your application

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

Automatic Sliding Door Systems

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

HDA

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No PR01. ift Rosenheim

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

DELTA3-1. Delta 3 Data Centre Rack Solution

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Initial Type Testing Report

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

How To Buy A Designo Grille

Material test chamber with mechanical convection

Technical Data Honeycomb Door Leaf

Luxor. Automatic retractable bollard

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

DIGITUS Network & Server Cabinets. UNIQUE Series

Transcription:

New: Standard Safety Light Grille High-Speed Doors Technical Manual: Issue 01.03.2011

Hörmann High-Speed Doors A broad programme for inside and outside From low-cost design models to secure night doors Hörmann high-speed doors are characterised by excellent material quality and reliable long-term function. They are used inside and outside to optimise the flow of traffic, improve room climate and save energy. This broad programme includes transparent doors with flexible curtains that open vertically or horizontally. For day/night doors, we also offer flexible high-speed doors combined with rolling shutters and sectional doors. Hörmann high-speed doors comply with strict European safety requirements. 2 Technical Manual: High-speed doors / 03.2011

Contents Contents Page Spiral doors Technical data 4 HSS 6530 (L) 5-7 HS 7030 PU 8-10 Flexible internal doors Technical data 12 V 2715 SEL R 13 V 5015 SEL 14-16 V 5030 SEL 17-19 Flexible external doors Technical data 20 V 6030 SEL 21-23 V 6020 TR L 24-26 V 10008 27-28 Rolling shutter and vertical high-speed door combination 29 Cold store and deep freeze doors Technical data 30 ISO SPEED COLD 31-32 V 4015 ISO L 33 Special doors Technical data 34-35 V 3015 RW 36-38 V 2515 FOOD L 39 V 2012 40 V 1401 ATEX 41-43 V 3015 CLEAN 44 V 3009 45-47 H 3530 48-49 No part may be reproduced without our prior permission. All rights reserved. All dimensions in mm. Subject to design changes. Technical Manual: High-speed doors / 03.2011 3

Spiral Doors Technical data HSS 6530 HSS 6530 L Use Internal door External door Speed Opening speed approx. m/sec. 1.5 3.0 1.5 3.0 Closing speed approx. m/sec. 0.5 0.5 Safety equipment DIN EN 13241.1 Resistance to wind load DIN EN 12424 Class 4 Class 4 Resistance to water penetration DIN EN 12425 Class 2 Class 2 Air permeability DIN EN 12426 Class 2 Class 2 Transmission of heat DIN EN 12428 2.9 / 1.8 with Iso infill 2.9 / 1.8 with Iso infill Acoustic insulation DIN EN 52210 db 31 31 Shutter sizes Max. width LDB 6500 6500 Max. height LDH 6000 4500 Fitting dimensions (space requirement) (See also the Technical Manual) Operator side (with cladding) 430 (455) 430 ( ) Bearing side (with cladding) 390 (415) 390 ( ) Lintel (with cladding) 550 ( ) Lintel LDH up to 4500 mm (with cladding) 950 (1000) Lintel LDH from 4501 to 5500 mm (with cladding) 970 (1020) Lintel LDH from 5501 to 6500 mm (with cladding) 950 (1000) Control in steel cabinet (W H D) 400 600 200 400 600 200 Door construction Self-supporting Door leaf counterbalance Door leaf Double-skinned profile thickness 30 30 Thermal profile Material/surface of door leaf Anodised aluminium E6/EV1 Aluminium, powder-coated, RAL to choose Glazing Single synthetic panes Double synthetic panes Ventilation grille Ventilation cross section depending on size/version Operator and control Frequency converter Connecting voltage 3-400 V, N, PE 3-400 V, N, PE Open-Stop-Close button Main switch all-pole switch off Fuse protection 16 A, K-characteristic 16 A, K-characteristic Protection category for operator and control IP 54 IP 54 Emergency-off button Route monitoring Photocell Light grille Door area monitoring Radar Induction loop Hold-open phase in sec. 1-200 1-200 Closing edge safety device Electronic limit switch DES Emergency opening Emergency crank handle Emergency hand chain Counter weight/spring / / FU control with UPS 230 V Volt-free contacts Impulse generator Safety devices Standard Optional 4 Technical Manual: High-speed doors / 03.2011

Spiral Doors HSS 6530 ** If LDH > 4500 mm 5500 mm *** If LDH > 5500 mm SD Lintel seal = LDH + 100 Technical Manual: High-speed doors / 03.2011 5

Spiral Doors HSS 6530 Full cladding ** If LDH > 4500 mm 5500 mm *** If LDH > 5500 mm 6 Technical Manual: High-speed doors / 03.2011

Spiral Doors HSS 6530 L ** Centre fixing of ceiling suspension *** LDH 3250 mm = 1770 mm LDH > 3250 mm = 2350 mm SD Lintel seal = LDH + 90 Technical Manual: High-speed doors / 03.2011 7

Spiral Doors Technical data HS 7030 PU Use Internal door External door Speed Opening speed approx. m/sec. 1.5 2.5 Closing speed approx. m/sec. 0.5 0.8 Safety equipment DIN EN 13241.1 Resistance to wind load DIN EN 12424 Class 4 Resistance to water penetration DIN EN 12425 Class 3 Air permeability DIN EN 12426 Transmission of heat DIN EN 12428 1.95 Acoustic insulation DIN EN 52210 db 26 Shutter sizes Max. width LDB 6500 Max. height LDH 6000 Fitting dimensions Operator side (with cladding) 665 (665) (space requirement) Bearing side (with cladding) 365 (415) (See also the Technical Manual) Lintel (with cladding) Lintel LDH up to 5000 mm (with cladding) 885 (970) Lintel LDH from 5001 to 6000 mm (with cladding) 920 (1005) Control in steel cabinet (W H D) 400 600 200 Door construction Self-supporting Door leaf counterbalance Door leaf Double-skinned section thickness 42 Foamed door leaf Material/surface of door leaf Steel, RAL 9006 Wet coating in RAL to choose Aluminium rail window, anodised aluminium E6/EV1 Glazing Double synthetic panes Triple synthetic panes Ventilation grille Ventilation cross section depending on size/version (min. 30%) Operator and control Frequency converter Connecting voltage (3-phase) 3-400 V, N, PE Open-Stop-Close button Main switch all-pole switch off Fuse protection 16 A, K-characteristic Protection category for operator and control IP 54 Emergency-off button Closing edge safety device with energy chain Monitoring Safety light grille IP 67 of the closing zone External route monitoring Photocell Light grille Door area monitoring Radar presence detector Induction loop Hold-open phase in sec. 1-200 Electronic limit switch DES Emergency opening Emergency crank handle Emergency hand chain Counter weight/spring / FU control with UPS 230 V (1-phase) Volt-free contacts Impulse generator Safety devices Standard Optional 8 Technical Manual: High-speed doors / 03.2011

Spiral Doors HS 7030 PU * Space required to fit/dismantle the operator ** If LDH 5000 mm *** If LDH > 5000 mm 6000 mm SD Lintel seal = LDH + 90 WS Shaft supports LDB > 3315 = 1 unit in centre LDB > 5000 = 2 units equally distributed Technical Manual: High-speed doors / 03.2011 9

Spiral Doors HS 7030 PU ** If LDH 5000 mm *** If LDH > 5000 mm 6000 mm 10 Technical Manual: High-speed doors / 03.2011

Notes Technical Manual: High-speed doors / 03.2011 11

Flexible Internal Doors Technical data V 2715 SEL R V 5015 SEL V 5030 SEL Use Internal door External door Wind protected 1) Speed FU control Opening speed approx. m/sec. 1.5 1.5 2.0 3.0 Closing speed approx. m/sec. 0.8 0.8 0.8 Safety equipment DIN EN 13241 Resistance to wind load DIN EN 12424 Class 0 Class 0 Class 0/1 with aluminium bottom profile Curtain stabilisation/ws Alu/spring steel / / / Shutter sizes Max. width LDB 2750 5000 5000 Max. height LDH 3000 5000 5000 Fitting dimensions (space requirement) (See also the Technical Manual) Operator side LDB + mm (with cladding) (200) 345 (375) 385 (425) Bearing side LDB + mm (with cladding) (200) 175 (175) 255 (290) Lintel LDH + mm 440 440 / 520 1) LDH + mm, straight cladding 460 490 490 / 570 1) LDH + mm cladding 30 (5 ) 630 630 / 710 1) FU control in plastic cabinet (W H D) 200 400 200 200 400 200 200 400 200 FU control in steel cabinet (W H D) (stainless steel 1.4301) UPS 400 600 200 400 600 200 400 600 200 Anti-Crash/crash-protection With automatic/manual start-up Crashprotection Anti-Crash Anti-Crash Door construction Self-supporting Fabric/transparent 1.5/2.0 mm Transparent 4.0 mm Curtain/door leaf tension Material/surface guide Galvanized steel Galvanized steel, coated, in colours based on RAL Polished stainless steel V2A Shaft/operator cover Straight 30 chamfered (5 ) Operator and control FU control Connecting voltage (1-phase) 1-230 V, N, PE 1-230 V, N, PE 1-230 V, N, PE Connecting voltage (3-phase) 3-400 V, N, PE Open-Stop-Close button FU control, main switch all-pole switch off, 1-phase/3-phase / / / Fuse protection 16 A, K-characteristic 16 A, K-characteristic 16 A, K-characteristic Protection category Operator, control IP 54 IP 54 IP 54 Emergency-off button Closing edge safety device With energy chain Monitoring Safety light grille IP 67 of the closing zone External route monitoring Photocell Light grille Door area monitoring Radar presence detector Induction loop Hold-open phase in sec. 1-200 1-200 1-200 Electronic limit switch DES Emergency opening Crank handle Emergency hand chain Counter weight/springs / / / FU control with UPS 230 V (1-phase) Volt-free contacts Impulse generator Safety devices Standard WS Wind lock Optional 1) Optional with aluminium bottom profile 12 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 2715 SEL R X LDH Order-related Clear passage height SD Lintel seal = LDH + 190 Technical Manual: High-speed doors / 03.2011 13

Vertical High-Speed Doors V 5015 SEL ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 170 14 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 5015 SEL Full cladding, straight ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 15

Vertical High-Speed Doors V 5015 SEL Full cladding, chamfered ***** For emergency crank handle 16 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 5030 SEL ** With aluminium bottom part ***** For emergency crank handle X LDH Order-related Clear passage height SD Lintel seal = LDH + 130 Technical Manual: High-speed doors / 03.2011 17

Vertical High-Speed Doors V 5030 SEL Full cladding, straight ** With aluminium bottom part ***** For emergency crank handle 18 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 5030 SEL Full cladding, chamfered ** With aluminium bottom part ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 19

Flexible External Doors Technical data V 6030 SEL V 6020 TR L V 10008 Use Internal door External door Speed FU control Opening speed approx. m/sec. 2.0 3.0 1.5 2.0 0.8 1.5 Closing speed approx. m/sec. 0.8 0.5 0.4 Safety equipment DIN EN 13241 Resistance to wind load DIN EN 12424 Class 2 Class 2 Class 3 Curtain stabilisation/ws Alu/spring steel / / / Shutter sizes Max. width LDB 5000 6000 10000 Max. height LDH 6000 7000 6250 Fitting dimensions (space requirement) (See also the Technical Manual) Operator side LDB + mm (with cladding) 460 (505) 420 (470) 545 (580) Bearing side LDB + mm (with cladding) 335 (355) 300 (300) 390 (390) Lintel LDH + mm (with curtain fixing) 540 (615) 680 (760) (745) LDH + mm, straight cladding 590 720 LDH + mm cladding 30 (5 ) 730 800 (840) FU control in plastic cabinet (W H D) 200 400 200 200 400 200 FU control in steel cabinet (W H D) (Stainless steel 1.4301) 400 600 200 400 600 200 400 600 200 Anti-Crash/crash-protection With automatic/manual start-up Crashprotection Door construction Self-supporting Fabric/transparent 1.5/2.0 mm Transp./fabric/transp. 4.0 (< 25 mm 2 ) / 2.4/4.0 mm / / / Curtain/door leaf tension Material/surface guide Galvanized steel Galvanized steel, coated, in colours based on RAL Polished stainless steel V2A Shaft/operator cover Straight 30 chamfered (5 ) ( ) Operator and control FU control Connecting voltage (1-phase) 1-230 V, N, PE 1-230 V, N, PE Connecting voltage (3-phase) 3-400 V, N, PE 3-400 V, N, PE 3-400 V, N, PE Open-Stop-Close button FU control, main switch all-pole switch off, 1-phase/3-phase / / / Fuse protection 16 A, K-characteristic 16 A, K-characteristic 16 A, K-characteristic Protection category Operator, control IP 54 IP 54 IP 54 Emergency-off button Closing edge safety device With energy chain Monitoring of the closing zone Safety light grille IP 67 External route monitoring Photocell (internal) ( ) Light grille Door area monitoring Radar presence detector Induction loop Hold-open phase in sec. 1-200 1-200 1-200 Electronic limit switch DES Emergency opening Crank handle Emergency hand chain Counter weight/springs / / / FU control with UPS 230 V (1-phase) Volt-free contacts Impulse generator Safety devices Standard WS Wind lock Optional 20 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 6030 SEL ** With curtain fixing **** Only if fitted to steel ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 270 Technical Manual: High-speed doors / 03.2011 21

Vertical High-Speed Doors V 6030 SEL Full cladding, straight ***** For emergency crank handle 22 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 6030 SEL Full cladding, chamfered ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 23

Vertical High-Speed Doors V 6020 TR L ** Space requirement for fitting curtain fixing *** Space requirement for swivelling range cover ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 320 24 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 6020 TR L Full cladding, straight *** Space requirement for swivelling range cover ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 25

Vertical High-Speed Doors V 6020 TR L Full cladding, chamfered *** Space requirement for swivelling range cover ***** For emergency crank handle 26 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 10008 *** Space requirement for swivelling range cover X Order-related SD Lintel seal = LDH + 345 Technical Manual: High-speed doors / 03.2011 27

Vertical High-Speed Doors V 10008 Full cladding ** LB > 7300 mm or LDH > 6500 mm *** Space requirement for swivelling range cover 28 Technical Manual: High-speed doors / 03.2011

Rolling Shutter and Vertical High-Speed Door Door combination Rolling shutter Decotherm (HR 116, HR 120) with direct drive operator and ZAK system, vertical high-speed door V 6030 SEL ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 29

Cold Store and Deep Freeze Doors Technical data ISO SPEED COLD V 4015 ISO L Use Internal door External door Speed FU control Opening speed approx. m/sec. 2.0 1.5 Closing speed approx. m/sec. 0.5 0.5 Safety equipment DIN EN 13241 Resistance to wind load DIN EN 12424 Class 3 Class 0 Curtain stabilisation/ws Alu/spring steel / / Shutter sizes Max. width LDB 5000 4000 Max. height LDH 5000 4500 Fitting dimensions (space requirement) (See also the Technical Manual) Operator side LDB + mm (with cladding) 510 ( ) 325 (360) Bearing side LDB + mm (with cladding/counter weight) 375 ( /375) 295 (325/ ) Lintel LDH + mm 1) 630 LDH + mm, straight cladding LDH + mm cladding 30 (5 ) ( ) (720) FU control in plastic cabinet (W H D) 200 400 200 FU control in steel cabinet (W H D) (Stainless steel 1.4301) 400 600 200 400 600 200 Anti-Crash/crash-protection With automatic/manual start-up Door construction Self-supporting Curtain/door leaf Door leaf 80 mm, PU-foamed Curtain 20 mm, PO foam Curtain/door leaf tension Material/surface guide Galvanized steel Galvanized steel, coated, in colours based on RAL Polished stainless steel V2A Shaft/operator cover Straight 30 chamfered (5 ) ( ) Operator and control FU control Connecting voltage (1-phase) 1-230 V, N, PE Connecting voltage (3-phase) 3-400 V, N, PE Open-Stop-Close button FU control, main switch all-pole switch off, 1-phase/3-phase / / Fuse protection 20 A, K-characteristic 16 A, K-characteristic Protection category Operator, control IP 54 IP 54 Emergency-off button Closing edge safety device With energy chain Monitoring Safety light grille IP 67 of the closing zone External route monitoring Photocell (internal) ( ) Light grille Door area monitoring Radar presence detector Induction loop Hold-open phase in sec. 1-200 1-200 Electronic limit switch DES Emergency opening Crank handle Emergency hand chain Counter weight/springs / / FU control with UPS 230 V (1-phase) Volt-free contacts Impulse generator Safety devices Standard WS Wind lock Optional 1) Track application N: LDH + 950 mm, track application V: LDH x 2 + 800 mm 30 Technical Manual: High-speed doors / 03.2011

Sectional Doors ISO SPEED COLD H tracks Door version with high-lift track application NH, H and HD FFL X Order-related ET Distance back DA Distance to ceiling DH DM EN LH FFL Rear ceiling anchor Centre ceiling anchor Ceiling height Track height Finished floor level Technical Manual: High-speed doors / 03.2011 31

Sectional Doors ISO SPEED COLD Track application V Door version with vertical track application and overhead operator (V) FFL X Order-related LDB DE FFL Clear passage width Min. ceiling height 2 x LDH + 850 mm Finished floor level 32 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 4015 ISO *** Optional cladding 5 ***** For emergency crank handle SD Lintel seal = LDH + 380 Technical Manual: High-speed doors / 03.2011 33

Special Doors Technical Data V 3015 RW Use Internal door External door Speed FU control Opening speed approx. m/sec. 1.5 Closing speed approx. m/sec. 0.8 Safety equipment DIN EN 13241 Resistance to wind load DIN EN 12424 Class 0 Curtain stabilisation/ws Alu/spring steel / Shutter sizes Max. width LDB 3000 Max. height LDH 3000 Fitting dimensions (space requirement) See also the Technical Manual Operator side LDB + mm (with cladding) 325 (355) Bearing side LDB + mm (with cladding) 300 (300) Lintel LDH + mm 440 LDH + mm, straight cladding 490 LDH + mm cladding 30 (5 ) 670 FU control in plastic cabinet (W H D) FU control in steel cabinet (W H D) (Stainless steel 1.4301) 300 400 150 Anti-Crash/crash-protection With automatic/manual start-up Anti-Crash Door construction Self-supporting Curtain/door leaf Fabric/transparent 1.5/2.0 mm Transparent 4.0 mm Curtain/door leaf tension Material/surface guide Galvanized steel Galvanized steel, coated, in colours based on RAL Polished stainless steel V2A Shaft/operator cover Straight 30 chamfered (5 ) Operator and control WU control FU control Connecting voltage (1-phase) 1-230 V, N, PE Connecting voltage (3-phase) Open-Stop-Close button FU control, main switch all-pole switch off, 1-phase/3-phase / Fuse protection 16 A, K-characteristic Protection category Operator, control IP 54 Emergency-off button Closing edge safety device With energy chain With spiral cable Monitoring Safety light grille IP 67 of the closing zone External route monitoring Photocell (internal) ( ) Light grille Door area monitoring Radar presence detector Induction loop Hold-open phase in sec. 1-200 Electronic limit switch DES Emergency opening Crank handle Emergency hand chain Counter weight/springs / FU control with UPS 230 V (1-phase) Volt-free contacts Impulse generator Safety devices Standard WS Wind lock Optional 34 Technical Manual: High-speed doors / 03.2011

V 2515 FOOD L V 2012 V 1401 ATEX V 3015 CLEAN V 3009 H 3530 1.2 1.2 1.4 1.5 (AKE 0.8) 3.0 0.8 0.5 0.5 0.5 (AKE 0.8) 1.0 Class 0 Class 0 Class 0 Class 0 Class 0 Class 0 / / / / / / 2500 2500 4000 2500 3000 3500 3000 2500 4000 3000 3000 3500 (355) (345) 435 (475) (380) 310 (310) (355) (200) (180) 150 (150) (225) 150 (180) (355) 660 300 400 700 335 370 (480) 850 (550) 480 520 200 400 200 200 400 200 200 400 200 300 400 150 600 600 200 300 400 150 V2A Anti-Crash Anti-Crash ( ) ( ) 1-230 V, N, PE 1-230 V, N, PE 1-230 V, N, PE 1-230 V, N, PE 1-230 V, N, PE 1-230 V, N, PE / / / / / / 16 A, K-characteristic 16 A, K-characteristic 16 A, K-characteristic 16 A, K-characteristic 10 A (16 A, K-characteristic/FU) 16 A, K-characteristic IP 65 IP 54 IP 54 IP 54 IP 54 IP 54 ( ) ( ) ( ) ( ) 1-200 1-200 1-200 1-200 1-200 1-200 / / / / / / Technical Manual: High-speed doors / 03.2011 35

Vertical High-Speed Doors V 3015 RW ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 165 36 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 3015 RW Full cladding, straight ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 37

Vertical High-Speed Doors V 3015 RW Full cladding, chamfered ***** For emergency crank handle 38 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 2515 FOOD L X Order-related SD Lintel seal = LDH + 170 Technical Manual: High-speed doors / 03.2011 39

Vertical High-Speed Doors V 2012 X Order-related 40 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 1401 ATEX ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 160 Technical Manual: High-speed doors / 03.2011 41

Vertical High-Speed Doors V 1401 ATEX Full cladding, straight ***** For emergency crank handle 42 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 1401 ATEX Full cladding, chamfered ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 43

Vertical High-Speed Doors V 3015 CLEAN ***** For emergency crank handle SD Lintel seal = LDH + 225 and LDH + 438 44 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 3009 ***** For emergency crank handle X Order-related SD Lintel seal = LDH + 140 Technical Manual: High-speed doors / 03.2011 45

Vertical High-Speed Doors V 3009 Full cladding, straight ***** For emergency crank handle 46 Technical Manual: High-speed doors / 03.2011

Vertical High-Speed Doors V 3009 Full cladding, chamfered ***** For emergency crank handle Technical Manual: High-speed doors / 03.2011 47

Horizontal High-Speed Doors H 3530 Full cladding, straight 48 Technical Manual: High-speed doors / 03.2011

Horizontal High-Speed Doors H 3530 Full cladding, chamfered LDH LDB Clear passage height Clear passage width Technical Manual: High-speed doors / 03.2011 49

Notes 50 Technical Manual: High-speed doors / 03.2011

Notes Technical Manual: High-speed doors / 03.2011 51

Hörmann: Quality without Compromise Hörmann KG Amshausen Hörmann KG Antriebstechnik Hörmann KG Brandis Hörmann KG Brockhagen Hörmann KG Dissen Hörmann KG Eckelhausen Hörmann KG Freisen Hörmann KG Ichtershausen Hörmann KG Werne Hörmann Genk NV, Belgium Hörmann Alkmaar B.V., Netherlands Hörmann Legnica Sp. z o.o., Poland Hörmann Beijing, China Hörmann Tianjin, China Hörmann LLC, Montgomery IL, USA Hörmann Flexon, Leetsdale PA, USA Hörmann is the only manufacturer worldwide that offers you a complete range of all major building products from one source. We manufacture in highly-specialised factories using the latest production technologies. The close-meshed network of sales and service companies throughout Europe, and activities in the USA and China, make Hörmann your strong partner for first-class building products, offering Quality without Compromise. GARAGE DOORS OPERATORS INDUSTRIAL DOORS LOADING EQUIPMENT HINGED DOORS DOOR FRAMES Issue 03.2011/Print 06.2011/HF 84900 EN / PDF Hörmann (UK) Ltd, Gee Road, Coalville, Leicestershire LE67 4JW Phone (01530) 513000, Fax (01530) 513001