Technical product description High-speed roll-up door Machine protection. For internal use only
|
|
|
- Paulina Doyle
- 9 years ago
- Views:
Transcription
1 Technical product description High-speed roll-up door Machine protection EN For internal use only
2 This technical product description applies exclusively to the following door type: EFA-SRT -L MS, type 287 EFA-SRT -S MS, type 288 EFAFLEX Tor- und Sicherheitssysteme GmbH & Co. KG Fliederstraße Bruckberg GERMANY Telephone: Fax: Internet: Translation of the original Version 03-EN EFAFLEX Tor- und Sicherheitssysteme GmbH & Co. KG 2 High-speed roll-up door Machine protection
3 Table of contents Table of contents 1 Short description Technical properties Construction of the high-speed roll-up door machine protection Door safety Equipment Packaging units High-speed roll-up door Machine protection 3
4 Short description 1 Short description Fig. 1: EFA-SRT -L/S MS high-speed roll-up door The EFA-SRT -L/S MS high-speed roll-up door is a functionally reliable, space-saving and low-maintenance machine protection door which has been specially engineered for intensive industrial use. 4 High-speed roll-up door Machine protection
5 Short description The EFA-SRT -L/S MS high-speed roll-up door is a safety component with EC type examination certification as per Machinery Directive 2006/42/EC and a certified performance Level "d" for safetyrelated functions as per DIN EN ISO It is a standalone powered segregating safety device with locking mechanism as per DIN EN 953 which, in conjunction with the control system of the machine, provides the highest level of safety for personnel and plants and machines in the industrial and commercial sector. The side frames have integrated floor supports and are thus selfsupporting. This means that the EFA-SRT -L/S MS high-speed roll-up door can be set up free-standing. The side frames and the casings for the winding shaft and the drive are made of galvanised sheet steel. The flexible door curtain on the EFA-SRT -L/S MS is available in the following different colours and designs to suit the application: Transparent soft PVC with warning stripes, highly tear-resistant and low-stretch woven fabric with double-sided PVC coating and soft PVC in welded design as per DIN EN All variants are free from substances which prevent paint adhesion. The high-performance frequency converter controller in conjunction with the functionally adapted drive makes for particularly dynamic door running. The locking mechanism for monitoring the secure closed position allows the machine to be integrated into cat. 4 / PL e as per DIN EN ISO The EFA-SRT -L/S MS thus meets all requirements fore a secure and modern "machine protection door" with a high cycle rate and can be used in almost all production processes. High-speed roll-up door Machine protection 5
6 Technical properties 2 Technical properties Use Danger area Operating area Fig. 2: Use Dimensions Use Segregating safety device (with safety limit switch as a locking mechanism) Area of application Industrial applications Plants and machines Welding booths Temperature range for use +5 C to +50 C EFA-SRT -L MS Indication Value Unit Door width mm Door height mm Fig. 3: Diagram of possible door heights and door widths (EFA-SRT - L MS, type 287) EFA-SRT -S MS Indication Value Unit Door width mm Door height mm Fig. 4: Diagram of possible door heights and door widths (EFA-SRT - S MS, type 288) 6 High-speed roll-up door Machine protection
7 Technical properties Speeds Data Value Unit Cycles per minute 7 Opening speed (max.) approx. 1.3 (1.8) m/s Closing speed approx. 0.8 m/s Performance properties Data Value Air permeability as per DIN EN Class 0 Resistance to wind load as per DIN EN Class 0 Airborne sound insulation as per EN ISO db Fire performance as per DIN 4102 Data Material class* Value B2 normally inflammable *optional: Material class B1 (only available without viewing window) Applied safety standards The following standards were applied for planning, engineering and production: DIN EN DIN EN DIN EN DIN EN DIN EN DIN EN DIN EN DIN EN 953 DIN EN 1088 DIN EN /108/EC Doors Product standard Doors Safety in use of power operated doors Requirements Doors Safety in use of power operated doors Test methods Doors Mechanical aspects Requirements Doors Mechanical aspects Test methods Doors and gates Safety devices for power operated doors and gates Requirements and test methods Safety of machinery Safety-related parts of control systems Safety of machinery Guards General requirements for design and constructions of fixed and movable guards Safety of machinery Interlocking devices with associated guards Principle for design and selection Safety of machinery Electrical equipment of machines DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL from 15th December 2004 for alignment of the legal requirements of member states for electromagnet compatibility and withdrawal of Directive 89/336/EEC High-speed roll-up door Machine protection 7
8 Technical properties 2006/42/EC 2006/95/EC DIN EN ISO DIRECTIVE 2006/42/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL from 17th May 2006 on machines and for amendment of Directive 95/16/EC (new release) DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL from 12th December 2006 for alignment of the legal requirements of member states regarding electrical equipment for use within certain voltage limits Safety of machinery General design principles Risk assessment and risk reduction Basic construction performance Data Value Loadings per year Service life 12 years 8 High-speed roll-up door Machine protection
9 Construction of the high-speed roll-up door mach... 3 Construction of the high-speed roll-up door machine protection Fig. 5: Assemblies 1 Winding shaft Ä Winding shaft unit on page 10 2 Control unit Ä Control unit on page 15 3 Side frames with vertical door leaf guide, drum support, safety light barriers Ä Safety edge and light barrier on page 16 Ä Side frames with floor support on page 12 4 Door leaf with curtain and Ä Door leaf on page 13 Closing edge Ä Chapter 4 Door safety on page 16 5 Cover Ä Cover on page 10 6 Drive Ä Drive on page 15 7 Locking mechanism Ä Locking mechanism for powered segregating safety equipment on page 17 8 Floor support Ä Side frames with floor support on page 12 High-speed roll-up door Machine protection 9
10 Construction of the high-speed roll-up door mach... Winding shaft unit Fig. 6: Winding shaft with drive The winding shaft unit comprises: Winding shaft (Fig. 6/1) Galvanised steel tube Æ 114 mm (EFA-SRT -L MS, type 287) Galvanised steel tube Æ 159 mm (EFA-SRT -S MS, type 288) High-grade industrial bearings (Fig. 6/2) Drive (Fig. 6/3) Cover The winding shaft and the drive can be fully covered in optional sheet metal profiles. For door heights of less than 2500 mm cover is regulation as a protective guard. Fig. 7: Cover 10 High-speed roll-up door Machine protection
11 Construction of the high-speed roll-up door mach... Manual emergency operation Fig. 8: Manual emergency operation In case of power failure the door can be opened or closed mechanically with the winch which is included in the scope of delivery. The control unit is in EMERGENCY STOP status during this operation. High-speed roll-up door Machine protection 11
12 Construction of the high-speed roll-up door mach... Side frames with floor support Fig. 9: Side frame The side frames are made of bevelled, galvanised sheet steel profiles. The two-piece construction acts as the door leaf guide and makes for quick access for maintenance work. The optional floor supports mean the door can be set up freestanding. Unevenness in the floor can be offset with the levelling screws. Frame extension (optional) With an optional fame extension, both frame sides are extended but the door leaf maintains the same length. That means that the door leaf is not on the floor in the closed position but rather at the height of the original frame length. The locking mechanism is also at this height with extended frame sides. Fig. 10: Final position of door with frame extension 12 High-speed roll-up door Machine protection
13 Construction of the high-speed roll-up door mach... Door leaf The upper edge of the door leaf is permanently connected to the winding shaft. The shaft is rotated by the drive and can wind the door leaf up and down problem-free at any time. The door leaf is guided at the sides by the side frames with securing studs on the outer edge of the door curtain holding it securely in the guide even in the event of draughts and drops in air pressure. An end shield with safety edge forms the end element of the door leaf. The sheet metal parts are made of double-shell, galvanised, sheet steel. Plastic sliding blocks are fitted on both sides of the end segment for axial guidance. The door leaf is tensioned by the weight of the end shield. Fig. 11: Door leaf High-speed roll-up door Machine protection 13
14 Construction of the high-speed roll-up door mach... Door leaf versions 2 mm thick curtain made of soft transparent PVC with warning stripes Blue, similar to RAL 5002 Green, similar to RAL 6005 Orange, similar to RAL 2008 White, similar to RAL 9016 Yellow, similar to RAL 1021 Light grey, similar to RAL 7035 Red, similar to RAL mm thick curtain, made of PVC-coated woven polyester fabric, laterally stable, textured on both sides, with and without viewing window Blue, similar to RAL , 2 Yellow, similar to RAL Orange, similar to RAL Red, similar to RAL Papyrus white, similar to RAL 9018 standard 1, 2 Light grey, similar to RAL , 2 Signal grey, similar to RAL Charcoal grey, hardly inflammable 4 Soft PVC viewing window, transparent 1 anti-static finish 2 meets with the requirements of the directive of the FDA (U.S. Food and Drug Administration) for transportation of bulk food products with regard to the extraction behaviour 3 Silicone-free 4 Optionally available with translucent UV safety window as per DIN 1598 All curtains are free of substances which prevent paint adhesion (as per VW test). 14 High-speed roll-up door Machine protection
15 Construction of the high-speed roll-up door mach... Drive Drive type Power classes Protection type Position detection Direct mount drive 0.75 kw, 100 Hz, 3-phase (EFA-SRT -L MS, type 287) 1.5 kw, 100 Hz, 3-phase (EFA-SRT -S MS, type 288) IP54 Absolute encoder (no reference run required) The door can be operated in an emergency by connecting and actuating the manual emergency operation winch. At the same time the control system's emergency stop circuit is broken by an integrated micro switch. Fig. 12: Drive Control unit Fig. 13: Control unit Control unit Size Housing Protection type Functional elements accessible from the outside Master switch FU3E 300x400x120 mm Steel Colour: RAL 7035 IP54 Viewing window for displaying status and fault messages Membrane keypad for parametrising the door system/master switch At the front of the control cabinet (optional) Supply voltage 400 V AC +/- 10 % Frequency Supply cable With residual current device (RCD) as necessary Positioning of the control unit Hz Fuse protection of 16 A to be provided by the user (K characteristic) 300 ma as per DIN VDE (AC/DC sensitive) on the motor-side side frame High-speed roll-up door Machine protection 15
16 Door safety 4 Door safety The main closing edge is secured by a combination of a safety edge and a light barrier (C device plus D device). This achieves the minimum protection level as per EN Safety edge and light barrier Fig. 14: Safety edge and light barrier Closing edge safeguard Light barrier (optional) Flexible closing edge with sensor equipment in the carriage and signal transfer via energy chain Light barrier (IP67) installed in the door side frame, max. 1 The closing edge safeguard complies with the requirements of the product standard for doors DIN EN In addition the owner and the manufacturer have to consult with each other in order to provide a safeguard for the approach area. This will be based on the owner's risk assessment. 16 High-speed roll-up door Machine protection
17 Door safety Locking mechanism for powered segregating safety equipment Fig. 15: Locking mechanism The locking mechanism for monitoring the secure closed position allows the machine to be integrated into the plant/machine control system and is a cat. 4 / PL as per DIN EN ISO design. A servicing cover makes for easy access. Head-Safe option The door can be equipped with an optional safety light grid on the operator side. The safety light grid prevents the door from closing when an obstruction is detected. The installed height can be configured in accordance with requirements. High-speed roll-up door Machine protection 17
18 Equipment 5 Equipment Standard equipment Basic door construction, galvanised (275 g/m²) Winding drum, galvanised design Soft PVC, transparent, 2 mm thick, with warning stripes, blue FU3E control unit Direct mount drive Winch for emergency opening Safety edge Locking mechanism (safety limit switch) Optional equipment (special equipment subject to surcharge) Powder coated finish as per RAL All the curtain variants described in section Ä Door leaf versions on page 14 Casing, winding shaft and drive 1 safety light barrier, 300 mm from the floor Command devices: Push-buttons, pull switches, key switches etc. Command devices/safety: Radar detector, EFA-SCANâ, IR (infrared presence sensor) Locking mechanism (safety limit switch) Floor support Head-Safe option Special constructions Special constructions/special orders are design types which are not covered, either mechanically or electrically or in terms of materials or colours, by standard versions in the sales price lists or by a design from the technology variants table. Special enquiries have to be made for these designs which will also be subject to surcharges and longer delivery times in accordance with expenditure. 18 High-speed roll-up door Machine protection
19 Packaging units 6 Packaging units Fig. 16: Scope of delivery (standard transport unit) Transport unit (example): Side frames with covers, control unit, winding shaft with curtain, accessories Fig. 17: Wooden crate The number of transport units depends on the selected configuration. The transport units can also be delivered in a wooden crate. The number of wooden crates depend on the dimensions of the standard transport units. The wood for the wooden crates complies with the IPPC standard. The wooden crates are lined with film to protect them from moisture and are thus suitable for sea freight. Packages which are fastened to pallets can be transported by fork lift under the following conditions: The fork lift must have the appropriate capacity for the weight of the packages. The package must be securely fastened to the pallet. The fork lift driver must be authorised to drive industrial trucks with a driver's seat or driver's station in accordance with the local regulations. The transport units are not stackable. High-speed roll-up door Machine protection 19
20
21 EFAFLEX Tor- und Sicherheitssysteme GmbH & Co. KG Fliederstraße Bruckberg GERMANY Telephone: Fax: Internet:
High-speed folding doors. F Series
High-speed folding doors F Series 02 F Series The horizontal folding motion of high-speed folding doors ensures that the entire vertical clearance is achieved immediately. F Series doors open at high speed
High-speed spiral doors for deep-freeze applications. TK Series
High-speed spiral doors for deep-freeze applications TK Series 02 TK Series The cold chain for deep-frozen products must never be interrupted during storage and transport. This demands an enormous amount
MODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
ED 100LE ED 250LE. Low energy swing door operators
ED LE ED 250LE Low energy swing door operators ED LE & ED 250LE LOW ENERGY SWING DOOR OPERATORS LOW ENERGY SWING DOOR OPERATORS Automatic doors provide a means of opening and closing doors without the
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version
OLYM-S24D-C24D The Olympus 4HD is a heavy duty solenoid controlled access lock available with either a stainless steel tongue actuator or a heavy duty handle. The Olympus 4HD is capable of supporting Category
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
PLM series Permanent load lifting magnets
Lifting gear Load lifting magnets/chain hoists PLM series Permanent load lifting magnets Load-bearing capacity of up to 1 t depending on model despite light weight High standard of safety with simple lever
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
Electrical connection
(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
EC DECLARATION OF CONFORMITY FOR MACHINES
EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
K17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
HVAC air curtains. Type InduAir
Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
Guide to Safety Edge Systems
Guide to Safety Edge Systems Tel: 0845 054 5070 [email protected] Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
Group TRAFFIC MANAGEMENT SPECIALIST ACCESS WAY SOLUTIONS CREATIVE SOLUTIONS TO COMMON CHALLENGES. Products
Group Incorporating: Egmont Doors & totaldoors SPECIALIST ACCESS WAY SOLUTIONS TRAFFIC MANAGEMENT CREATIVE SOLUTIONS TO COMMON CHALLENGES 0800 807 753 [email protected] www.ultigroup.co.nz
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER
Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
Doc. No: 412-121033 Issue: 1 Date: Aug 2014. BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02
Date: Aug 2014 THERMAL TRANSFER CARD PRINTER BTT-02 TABLE OF CONTENTS Introduction... 3 System Contents and Initial Checks... 3 Installation... 4 Preparation of Installation Site... 4 Printer Connections...
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
V1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 01-m03-2016 2 IMPORTANT Ensure that only an authorized Savaria Dealer
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
New: Standard Safety Light Grille. High-Speed Doors
New: Standard Safety Light Grille High-Speed Doors Technical Manual: Issue 01.03.2011 Hörmann High-Speed Doors A broad programme for inside and outside From low-cost design models to secure night doors
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
Plaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
garage door operators
garage door operators duo vision separate control unit with integrated interior pushbutton Optional designer control housings other control unit housings with different finishes (ask about further designs)
Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
U-TK Transformer Kit. Parts included. Technical specifications. Engineering Data Sheet. Universal transformer kit. Power rating up to 100 W or 200 W
Engineering Data Sheet U-TK Transformer Kit Universal transformer kit Power rating up to 100 W or 200 W High quality toroidal transformer and connectors Power tapping (full, half or quarter power) and
CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor
CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor 7030.111 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer, Thank
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.
English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES
English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...
PHA 2000 PHB 3000 EXIT PAD
PHA 2000 PHB 000 EXIT PAD Panic Hardware in Contur Design PHA 2000 PHB 000 EXIT PAD THE MODULAR PANIC HARDWARE-SSTEM IN CONTUR DESIGN Prior knowledge of how to open the escape door is not expected. DANGER
Connection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
LED Lighting technology. Orientation with system
LED Lighting technology Orientation with system In buildings that are open to the public, clear identification is necessary to enable visitors to find their way around. Signs that provide directions and
ENGLISH FORK GUIDE 2013
FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Operating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Smoke exhaust systems
1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag.
CONTENTS 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. DESCRIPTION pag.1 3. TECHNICAL SPECIFICATIONS pag.13 4. INSTALLATION pag.13 5. TESTING THE AUTOMATED SYSTEM pag.19 6. MANUAL OPERATION pag.19
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Architectural Specifications MODEL HDXL 9. 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8
MODEL HDXL 9 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HDXL 9 Tech Specs September 4, 2012
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
DRUM ROLLER. FAR-1, Article No. B69-6300-A DRUM CART FOR 200 LITER STEEL DRUMS. Model FK 1029-1 FK 1029-3 FK 1029-2 FK 1029-4
DRUM ROLLER Suitable for drums up to 200 liter capacity Made from fire-galvanized sheet steel ø 610 mm, with 4 polyamide swiveling castors ø 75 mm Model FAR-1: closed version with welded leak-proof base,
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley
Selection Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley Basic mobile unit Basic mobile with vertical profiles Installation options Functional shelf, low Functional shelf, inclinable
Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1
Operating Instuctions Shaking device SV 14 / 22 SV 29 / 45 page 1 General notes, safety notes, notes on electrical equipment and electromagnetic compatibility, as well as notes on maintenance of the unit
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
Expertise in heavy loads. ThyssenKrupp freight elevators.
Expertise in heavy loads. ThyssenKrupp freight elevators. A Company of ThyssenKrupp Elevator ThyssenKrupp Aufzüge TK Moving heavy loads can be light work. Know-how and technology from a single source.
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer