Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830



Similar documents
Type: DILM9 10(24VDC) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technicaldata General

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Three-phase monitoring relay CM-PFE

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Catalog. Modular DIN rail components Installation contactors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Bimetallic Overload Relay Specifications

Technical catalogue. Modular DIN rail components Installation contactors

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RM4TG20 three-phase network control relay RM4-T - range V

Analog signal converters CC-E I/I Current / current isolators

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

48 SERIES Relay interface modules 10 A

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Manual motor starter MS116

Thermistor motor protection

PHOENIX CONTACT Features

Relés e Contatores de Estado Sólido SIRIUS

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

38 Series - Relay interface modules A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

38 Series - Relay interface modules A

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Safety technique. Emergency stop module BO 5988 safemaster

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Series 8146/5-V37 and Series 8150/5-V37

49 Series - Relay interface modules A. Features

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Redundancy Module QUINT-DIODE/40

Thermal-Magnetic Circuit Breaker M1-..

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ZS25 Screw Clamp Terminal Blocks Feed-through

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

R.C.C.B. s two-pole LEXIC

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

5SV Residual Current Protective Devices

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Pluggable interface relays CR-P Pcb relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Manual Motor Starter MS 116 up to 16 A Technical Data

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

EMR measuring and monitoring relays

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

MasterINTERFACE 39 Series - Relay interface modules

Plug and Socket Devices CES 63 A Series 8579

CQM1-SF200/CS1W-SF200

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Bulletin 150 SMC Flex Smart Motor Controller Specifications

CompactLogix Power Supplies Specifications

Actuator-Sensor-Interface

80 Series - Modular timers 16 A. Features

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Contact expansion modules

MasterINTERFACE 39 Series - Relay interface modules

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Contact expander modules

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Product and functional description

ELECTROMAGNETIC DISC BRAKES

ZS10 Screw Clamp Terminal Block

Quick Connect. quick - simple - efficient.

PSR The compact range Description

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

D-Line Contactors, Overload Relays and Accessories

Transcription:

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50 60 Hz AC 3 400 V Max. rating for three phase motors, 50 60 Hz AC 3 690 V Max. rating for three phase motors, 50 60 Hz AC 4 230 V Max. rating for three phase motors, 50 60 Hz AC 4 400 V Max. rating for three phase motors, 50 60 Hz AC 4 690 V P kw 15.5 P kw 22 P kw 30 P kw 6 P kw 10 P kw 14 Conventional thermal current I th = I e AC 1 Open I th = I e A 60 For use with DILM150 XHI(V).. DILM1000 XHI(V).. General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations 10 6 10 DC operated Operations 10 6 10 Operating frequency, mechanical AC operated Operations/h 5000 DC operated Operations/h 5000 Climatic proofing Ambient temperature Damp heat, constant, to IEC 60068 2 78 Damp heat, cyclical, to IEC 60068 2 30 1

Open C 25/60 Enclosed C 25/40 Storage C 40/80 Mechanical shock resistance (IEC/EN 60068 2 27) Half sinusoidal shock, 20 ms Main contacts Make contact g 10 Auxiliary contacts Make contact g 7 Break contact g 5 Protection type Protection against direct contact when actuated from front (IEC 536) Weight AC operated kg 0,9 DC operated kg 1,1 Terminal capacity Main cable Solid mm 2 1 (2.5 16) 2 (2.5 16) Flexible with ferrule mm 2 2 (2.5 25) 1 (2.5 35) Stranded mm 2 1 (16 50) 2 (16 35) IP00 Solid or stranded AWG 12 2 flat conductor Anschlussschraube Hauptleiter Number of segments width thickness Tightening torque Nm 3 Terminal capacity Control circuit cables Finger and back of hand proof mm 2 (6 9 0.8) Solid mm 2 1 (0.75 4) 1 (0.75 4) Flexible with ferrule mm2 Solid or stranded AWG 18 14 Anschlussschraube Hilfsleiter M3.5 Tightening torque Nm 1.2 Tool Main cable Pozidriv screwdriver Size 2 Standard screwdriver Control circuit cables Pozidriv screwdriver Size 2 Standard screwdriver Terminal capacity Control circuit cables mm mm M6 1 (0.75 2.5) 2 (0.75 2.5) 0.8 5.5 1 6 0.8 5.5 1 6 Solid mm 2 0.75 2.5 2

Flexible mm 2 0.75 2.5 Flexible with ferrule mm 2 0.75 2.5 Solid or stranded AWG 18 14 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree Rated insulation voltage AC U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 440 between the contacts V AC 440 Making capacity (cos Õ to IEC/EN 60947) up to 690 V Breaking capacity III/3 A 700 220/230 V A 500 380/400 V A 500 500 V A 500 660/690 V A 320 Component lifespan AC 3/AC 4 Tripping characteristics Maximum operating frequency AC 1; 400 V I e Ops/h 800 AC 3; 400 V I e Ops/h 800 AC 4; 400 V I e Ops/h 300 Short circuit rating Short circuit protection Maximum fuse Type 2 coordination 400 V gg/gl 500 V A 80 690 V gg/gl 690 V A 63 Type 1 coordination 400 V gg/gl 500 V A 160 690 V gg/gl 690 V A 80 AC AC 1 duty conv. therm. current 3 pole 50 60 Hz open at 40 C I th A 70 at 50 C I th A 65 at 55 C I th A 63 at 60 C I th A 60 Enclosed I th A 54 3

Conventional free air thermal current, 1 pole open I th A 150 Enclosed I th A 135 AC 3 duty Rated operational current AC 3 open, 50 60 Hz, 3 pole 220/230 V I e A 50 240 V I e A 50 380/400 V I e A 50 415 V I e A 50 440V I e A 50 500 V I e A 50 660/690 V I e A 32 Motor rating 220/230 V P kw 15,5 240V P kw 17 380/400 V P kw 22 415 V P kw 30 440 V P kw 32 500 V P kw 36 660/690 V P kw 30 AC 4 duty Rated operational current AC 4 open, 50 60 Hz, 3 pole 220/230 V I e A 21 240 V I e A 21 380/400 V I e A 21 415 V I e A 21 440 V I e A 21 500 V I e A 21 660/690 V I e A 17 Motor rating 220/230 V P kw 6 240 V P kw 6,5 380/400 V P kw 10 415 V P kw 11 440 V P kw 12 500 V P kw 13 660/690 V P kw 14 DC of three phase capacitors open DC 1 operation 60 V I e A 60 110 V I e A 50 220 V I e A 45 440 V I e A 2,9 DC 3 operation 4

60 V I e A 60 110 V I e A 50 220 V I e A 25 440 V I e A 0,6 DC 5 operation 60 V I e A 60 110 V I e A 50 220 V I e A 25 440 V I e A 0,6 Current heat loss (3 pole) Current heat loss at I th W 16,2 Current heat loss at I e to AC 3/400 V W 11,3 Impedance per pole m& 1,5 Magnet systems Voltage tolerance AC operated AC operated Pick up U c 0,8 1,1 Drop out voltage AC operated Drop out voltage AC operated Abfall U c 0,3 0,6 DC operated DC operated Pick up U c 0,7 1,2 DC operated DC operated Abfall U c 0,15 0,6 Power consumption of the coil in a cold state and 1.0 U c 50 Hz Pick up VA 130 50 Hz Pick up W 80 50 Hz Sealing VA 14 50 Hz Sealing W 4 DC operated Pick up W 24 at 24 V DC operated Sealing W 0.5 at 24 V Duty factor % DF 100 Switching times at 100 % U c (approximate values) Main contacts AC operated Closing delay ms 25 Opening delay ms 25 DC operated Closing delay ms 60 Opening delay ms 20 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference Interference immunity to EN 60947 1 to EN 60947 1 Mounting position, AC and DC operated 5

Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL C2005GB INT V3.0 6