Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info



Similar documents
User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

MFT Series INTRODUCTION UNPACKING FERRULES

OME-SERIES DATA ACQUISITION CARDS

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. info@omega.com

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com info@omega.com For latest product manuals: omegamanual.

User s Guide. SW DIN Series and OSW Series. Shop online at. Rotary Selector Switches

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at


User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

User s Guide WRS232-USB. Universal Wireless RS232 to USB Transceiver, WRS232 Wireless Transmitter, WUSB Wireless Receiver.

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM

User s Guide OM-USB-TC. 8 Channel Thermocouple Input USB Data Acquisition Module. Shop online at

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

BroadBand PowerShield. User Manual

Load Cell Amplifier Module. Instruction Manual LCA

Old Company Name in Catalogs and Other Documents

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Current Probes. User Manual

Original instructions Tina 3A/Aps Adaptor unit

Advantium 2 Plus Alarm

Tina 2A/B Adaptor unit

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

AP IR Remote Control Installation & Operation Manual

DVI to Analog Converter

INSTRUCTION MANUAL MODEL PCD-88

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

This product has the equivalent gain performance with the 14 element Yagi antenna.

PART 1 - INTRODUCTION...

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Smile 11 AS-i Emergency stop with safe AS-i input node

SDX Submersible Depth Transmitter User Manual

About this Manual. Support for Your Product

ATL Fuel Level Sender Probes

ARCHOS (

How To Use A Cdm250 Digital Multimeter

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Single Port T1/E1 Tap

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

User Guide. HDMI Active Cable Extender. DVI-7370c

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

LCD5500Z / PKP-LCD v3.x Installation Instructions

Hi5. HD-SDI/SDI To HDMI Video and Audio Converter User Manual. December 17, 2008 P/N For Hi5 Serial Number or Later

Wireless Base Station Single and Multiple Headsets

Owner s Manual & Safety Instructions

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Usage, Installation, Warranty and Service Information

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

Triple Expansion Chassis

TTL to RS232 Adapter User Guide

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Triton Systems of Delaware, LLC. Warranty Statement

IR Repeater. Operation Manual P8620

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

LM135-LM235-LM335. Precision temperature sensors. Features. Description

24.2L M.A.N. V12 Engine Module

iosafe Solo External Hard Drive

HIH-4000 Series Humidity Sensors

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Installation guide H A. HSI hardwired system interface

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

About Your NetBotz 4-20mA Sensor Pod

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

AVerMedia AVerKey imicro User s Manual

User and Installation Guide

Commercial Cardiovascular Equipment

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

Dual Laser InfraRed (IR) Thermometer

READ FIRST! Universal Car/Air Adapter User Manual

Instructions A Amp AC/DC Current Probe

Laptop Power Adapter for home/office User Manual

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

3 WATT LED SPOTLIGHT Model No. SLM

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Dolphin 9900 Mobile Computers

USER MANUAL. Kramer Electronics, Ltd. Models:

ExStik TM ph Waterproof Meters

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

Loop Calibration and Maintenance

USER MANUAL. Kramer Electronics, Ltd. Models:

±15 V Current-Limited Power Supply

USB Rover port USB m Cat 5 Extender. User Guide

FCC COMPLIANCE STATEMENT

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Transcription:

STCTX SERIES Industrial Thermocouple Connector/Transmitter INSTRUCTION SHEET M3935A/0810 Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info General Description The OMEGA STCTX Series is a medium performance, low cost, Industrial TC (Thermocouple) Connector/Transmitter. The STCTX features an encapsulated micro miniature signal conditioner built into a Universal Thermocouple Connector that converts the microvolt signal from a thermocouple sensor or probe across a dedicated temperature range to an industry standard 2-wire, 4 to 20mA analog output. This analog output can be sent hundreds of feet away from the location of your sensor (probe) to an indicating device, controller, PLC, computer, datalogger or chart recorder. Your STCTX Connector/Transmitter has been factory calibrated to provide maximum performance and should require no field adjustments when received. Note: Patents & Patents Pending Unpacking Remove the packing list and verify that you have received all of your OMEGA equipment. If you have any questions about the shipment, please call Customer Service at: 1-800-622-2378 or 203-359-1660. On the web you can find us at: omega.com e-mail: cservice@omega.com When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary. The following items are supplied in the box with your STCTX Connector/Transmitter. This User's Manual, # M3935A (1 ea.) Probe/Connector Locking Clips (2 ea.)

STCTX Series Thermocouple Connector/Transmitter Models Available Model No. Description Range STCTX-J1 with Universal Connector -18 to 121 C (0 to 250 F) STCTX-J2 with Universal Connector -18 to 538 C (0 to 1000 F) STCTX-K1 with Universal Connector -18 to 121 C (0 to 250 F) STCTX-K2 with Universal Connector -18 to 538 C (0 to 1000 F) STCTX-K3 with Universal Connector -18 to 1093 C (0 to 2000 F) STCTX-T1 with Universal Connector -18 to 121 C (0 to 250 F) STCTX-T2 with Universal Connector -18 to 399 C (0 to 750 F) SPRTX Series RTD Connector/Transmitter Models Available Model No. Description Range SPRTX-S1 with Standard Size Connector -99 to 208 C (-146 to 406 F) SPRTX-S2 with Standard Size Connector 2 to 569 C (36 to 1056 F) SPRTX-M1 with Miniature Size Connector -99 to 208 C (-146 to 406 F) SPRTX-M2 with Miniature Size Connector 2 to 569 C (36 to 1056 F) Recommended Accessories Regulated Power Supply, OMEGA Part No.: PSR-24L Shielded 2-conductor cable (100 ft), OMEGA Part No.: TX2-100 2

Introduction/Safety Your STCTX Thermocouple Connector/Transmitter has been designed for ease of use and flexibility. It is important that you read this User's Manual completely and follow all safety precautions before operating your unit. Precautions 1. FOLLOW ALL SAFETY PRECAUTIONS AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL. 2. INSURE PROBE/CONNECTOR SAFETY CLIPS ARE ALWAYS INSTALLED DURING USE. 3. ADD ADDITIONAL SAFE GUARDS TO YOUR SYSTEM IN CRITICAL APPLICATIONS WHERE DAMAGE OR INJURY MAY RESULT FROM PROBE/CONNECTOR SEPARATION OR FAILURE. 4. NEVER EXPOSE THE CONNECTOR/MODULE BODY TO AMBIENT TEMPERATURES ABOVE 85ºC (185ºF) OR BELOW -40 C (-40 F). DAMAGE MAY RESULT. 5. DO NOT OPERATE IN FLAMMABLE OR EXPLOSIVE ENVIRONMENTS. 6. DO NOT USE IN HUMAN, MEDICAL, OR NUCLEAR APPLICATIONS. 7. NEVER OPERATE WITH A POWER SOURCE OTHER THAN WHAT IS SPECIFIED IN THIS MANUAL. 8. REMOVE AND/OR DISCONNECT POWER SOURCE BEFORE ATTEMPTING INSTALLATION OR MAINTENANCE. 9. ALWAYS OPERATE YOUR UNIT WITH THE SHIELD WIRE CONNECTED TO EARTH GROUND. 10. INSTALLATION AND WIRING SHOULD BE DONE BY TRAINED PROFESSIONALS ONLY. 11. DO NOT OPEN OR DISASSEMBLE YOUR UNIT. NOTE There are no user serviceable parts inside your unit. Attempting to open, repair or service your unit will void your warranty. 3

Theory of Operation A 4 to 20 ma loop is a series loop in which a transmitter will vary the current flow depending on the input to the transmitter. With the STCTX the amount of current allowed to flow in the loop will vary depending on the microvolt change, due to changes in the temperature being measured by the thermocouple sensor (probe). Some advantages of a current output over a voltage output is that the signal measured is less susceptible to electrical noise interference and the loop can support more than one measuring instrument as long as the maximum loop resistance is not exceeded. A typical application utilizing a current loop will normally consist of a power supply, the transmitter and a meter, recorder or controller to measure the current flow. The loop resistance in the sum of the measuring instruments and wire used. The maximum allowable loop resistance for the STCTX to function properly is found by using the following formula: Rmax = (power supply voltage 9 volts)/.02 amps For applications that require a voltage output, the 4 to 20mA signal from the STCTX can be converted in the field by adding a 250 Ohm shunt resistor that will convert the transmitters output to a 1 to 5 Vdc signal when wired correctly. See Transmitter Wiring Examples in this manual. MANUFACTURING AREA CONTROL ROOM DC POWER SUPPLY + 24V THERMOCOUPLE PROBE STCTX CONNECTOR/ TRANSMITTER 1000 FT. MAX + PROCESS METER OR CONTROLLER 500 C 4

Mounting Your STCTX to Probes The STCTX Series Connector/Transmitters are designed for quick connection to Thermocouple sensors and probes. The STCTX will connect to all industry Thermocouple probes that feature Omega Style standard or miniature male connectors such as Omega OST-K-M standard size connector or SMP-K-M miniature size connector. See below for correct usage. Probe Locking Clips Probe locking clips are also provided to help secure your probe to the STCTX Connector/Transmitter. LOCKING CLIPS INSTALLED CAUTION Although your STCTX Connector/Transmitter will work with any Thermocouple sensor or probe, It is recommended that you use only OMEGA Thermocouple probes with you STCTX unit to insure proper installation and use of the probe locking clips. Probe locking clips are provided to offer added protection against the separation of your probe and connector/transmitter. In critical applications where separation of the Thermocouple probe from the connector/transmitter during normal operation could cause damage or harm, it is recommended that you install additional safety and locking devices to prevent the units from separating and/or shutting down your process. 5

Transmitter Wiring Examples 4 to 20mA Output (2-wire) RED WIRE + POWER SUPPLY STCTX BARE WIRE + 500 C BLACK WIRE EARTH GROUND DC VOLTAGE INPUT METER Converting from 4 to 20mA Output to 1 to 5Vdc Output (3-wire) 6

Protection from High Ambient Temperatures Note: Your STCTX Connector/Transmitter Assembly can be damaged if exposed to ambient temperatures above 85ºC (185ºF). Some applications may require that you shield the STCTX unit from radiated heat as shown below. You should always use a probe where the length allows for a safe distance of 76 mm (3") or more between the body of the STCTX and your source of heat. HIGH TEMPERATURE INSULLATION 3" COMPRESSION FITTING 7

Calibration/Service Your transmitter has been factory calibrated to meet or exceed the specifications outlined in this manual. No field adjustments should be needed. If your unit should become damaged or malfunction, please contact Omega Customer Service at: 1-800-622-2378 or 203-359-1660. On the web you can find us at: omega.com e-mail: cservice@omega.com Calibration Procedure Equipment Required: 1. Regulated DC Power Supply, 12-24 Vdc @ 30 ma 2. Digital DC Current Meter 3. Thermometer Simulator (Omega Model CL23A) 4. Test Leads 1. Connect the power supply, milli-amp meter and Thermometer simulator as shown on page 5 of this manual. 2. Set the Thermocouple simulator to the correct calibration type for the units being tested. 3. Set the Thermocouple simulator for the low end setting for the thermometer type you are testing. 4. Adjust "P1" on the STCTX for 4.00 ma output. 5. Set the Thermocouple simulator for the high end setting for the thermocouple type you are testing. 6. Adjust "P2" on the STCTX for 20.00 ma output. 7. Repeat steps 3, 4, 5, & 6 until correct readings are achieved. 8. Calibration complete. SPAN (P2) ZERO (P1) Specifications Temperature Input Range by model STCTX-J1, -K1, -T1-18 to 121ºC (0 to 250ºF) STCTX-J2, K2-18 to 538ºC (0 to 1000ºF) STCTX-T2-18 to 399ºC (0 to 750ºF) STCTX-K3-18 to 1093ºC (0 to 2000ºF) 8

Accuracy: ±0.5% of full scale @ 23ºC NOTE Thermocouple signals are non-linear. Your STCTX provides amplification, not linearization. You must take into account the non-linearity and inaccuracy of your thermocouple sensor to calculate your combined system accuracy. Repeatability: ±0.25ºC (0.5ºF) Output Stability/Temp Drift: ±0.002mA/ºC Max Ambient Temperature: -40 to 85 ºC (-40 to 185ºF) Output: 2-Wire, 4 to 20mA Power Supply: Regulated 9 to 24 Vdc @ 30mA max Max Loop Resistance: Ohms = (V supply 9 V)/.02 A Sensor Input Type: Ungrounded Thermocouple (J, K, T) Open Sensor Indication: Output goes above 20mA Connector Style/Material: Universal Omega Model UST (Glass Filled Nylon) Dimensions 79 x 18 x 24 mm (3.12 L x 0.70 W x.96" Weight 100 g (0.22 lb) Response Time: 120ms (0-63% of full scale) NOTE Cable shield wire must be connected to earth ground for Open Sensor Indication to function correctly. The STCTX Series is not designed for use in medical or nuclear applications, nor flammable or explosive environments. The published performance tolerance of this product may be derated by up to several percent if operated in the presence of strong radio frequency energy. This condition may occur if operation takes place within 1 or 2 Km of a comercial radio or TV station or when communication devices, such as walkie talkies, with signal strengths in the order of 1 watt or greater are used in the area of operation. Patents and Patents Pending 9

Servicing North America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Canada: OMEGAnet Online Service omega.com Toll-Free: 1-800-826-6342 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com 976 Bergar Laval (Quebec), H7L 5A1 Canada Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Sales Service: 1-800-826-6342/1-800-TC-OMEGA Canada: Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807 Latin Ameica info@omega.com.mx e-mail:espanol@omega.com Internet e-mail info@omega.com Servicing Europe: Benelux: Managed by the United Kingdom Office Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl Czech Frystatska 184 Republic: 733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz Managed by the United Kingdom Office France: Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de United OMEGA Engineering Ltd. Kingdom: One Omega Drive, River Bend Technology Centre, Northbank ISO 9001 Irlam, Manchester M44 5BD United Kingdom Certified Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 e-mail: sales@omega.co.uk It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2010 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.