Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820



Similar documents
Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

TEST REPORT EN (1997) +A1 (2001)

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Test Report #: Date: April 8, 2005

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

EMC Test for Compliance with EU EMC Directive 2004/108/EU

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Declaration of Conformity.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Electromagnetic Compatibility Test Report Test results of Floww equipment

Declaration of Conformity.

RAPPORTO DI PROVA / TEST REPORT

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

Dual Chamber Temporary External Pacemaker

Declaration of Conformity.

Declaration of Conformity.

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Declaration of Conformity.

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Waveguide Access Point WGA631. Product Guide

Declaration of Conformity.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

DATA SHEET DVI - HDCP Extension Cable

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

Espotel Test Laboratory Services. November 20, 2014

Telephone- and leased line modem for industrial applications TD-36

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

Foxboro Evo Process Automation System

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

STRATO LED Drivers 70W, Single output

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Item tested : Tecsonic DAB518. Type of equipment : DAB & FM radio. Client : Post- og teletilsynet

Data Communications Competence Center

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

Rack mounted telephone- and leased line modem for industrial applications

ANSI Watthour Meter Testing & Certification Programs

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Digital Active Indoor Antenna SRT ANT 10 ECO

T200, PTP/IEEE 1588 Grandmaster Clock and

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Radio Frequency Exposure Test Report

Report No R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

30 In Compliance October

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Design Guide for the Control of ESD in the esata Interface

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

Indoor / Outdoor Antenna

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

Why test results can t compare

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Report No R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE

Rules for Classification and Construction Additional Rules and Guidelines

Uncertainty evaluations in EMC measurements

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Experience with taximeters with a look at the corresponding tables

Electrified Door Hardware Why Planning for FCC Certification is Key to Success in the Door Hardware Industry

Report No R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

EMC Standards: Standards of good EMC engineering

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100

ORION TELECOM NETWORKS INC. T1

Draft ETSI EN V1.2.1 ( )

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Coupling/Decoupling Networks (CDN)

Transcription:

Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03) and IEC 61000-6-3 (2006-07) Date of Issue: May 23, 2013 On the behalf of the applicant: Attention of: Technologic Systems, Inc. 16525 E Laser Drive Fountain Hills, AZ 85268 Bob Miller, President Ph: (480) 837-5200 E-Mail: bob@embeddedarm.com Prepared By Compliance Testing, LLC 3356 N San Marcos Pl, Suite 107 Chandler, AZ 85225-7176 (866) 311-3268 phone / (480) 926-3598 fax www.compliancetesting.com Project No: p1350012 Alex Macon Project Test Engineer This report may not be reproduced, except in full, without written permission from Compliance Testing All results contained herein relate only to the sample tested Page 1 of 14

Test Report Revision History Revision Date Revised By Reason for Revision 1.0 May 23, 2013 Alex Macon Original Document Page 2 of 14

Table of Contents Description Page Conditions During Testing 5 Test Summary Table 7 Radiated Emissions 8 Electro-Static Discharge 10 ESD Test Results 11 Radio Frequency, Electromagnetic Field Immunity 12 Test Results 13 Test Equipment Utilized 14 Page 3 of 14

ILAC / A2LA Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer joint ISO-ILAC-IAF Communiqué dated January 2009) The tests results contained within this test report all fall within our scope of accreditation, unless noted below. Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation. Testing Certificate Number: 2152.01 FCC OATS Reg, #933597 IC Reg. #2044A-1 Non-accredited tests contained in this report: N/A Page 4 of 14

Conditions During Testing The tests were performed in accordance with the standards listed on the cover page. The tests were performed in the frequency bands being investigated, with the EUT in the most susceptible, or radiating operating mode consistent with normal applications. The configuration of the test sample has been varied to achieve maximum susceptibility consistent with typical applications and installation practices. If the EUT is a part of a system, or can be connected to auxiliary apparatus, the apparatus shall be tested while connected to the minimum representative configuration of auxiliary apparatus necessary to exercise the ports in a similar manner to that described in CISPR 11. If the manufacturer s specifications specifically require external protection devices or measures which are clearly specified in the user s manual, the test requirements of the standards listed on the cover page were performed with the external protection in place and documented under accessories. If the EUT has a large number of terminals, a sufficient number were selected to simulate actual operating conditions and to ensure that all the different types of terminations were covered The tests are carried out within the ranges of temperature, humidity and pressure specified for the EUT and at the rated supply voltage, unless otherwise indicated in the basic standard Temperature (ºC) Environmental Conditions Humidity (%) Pressure (mbar) 25.4 28.6 16.2% 34% 964.6 969.2 Summary of Restrictions 1. Revocation of CE mark by the European Authorities can occur at any time if the equipment does not meet or continue to meet the rules. 2. A sample may be requested at any time. EUT Description Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports EUT Operation During Tests The EUT was put into a test program during testing. There were audible clicks and visible LEDs to represent the device being exercised. A digital multi-meter was connected to monitor the output of one of the signal lines. Page 5 of 14

Accessories: Qty Description Mfg Model S/N 2 USB Drive N/A N/A N/A Qty Cables: Description Length (M) Shielding Y/N Shielded Hood Y/N Termination 1 Ethernet Cable <3m Y N EUT to 50 ohm load 1 Serial Cable <3m Y Y EUT to self termination 1 Power Supply <3m N N AC mains to EUT 1 Modifications: Customer provided ferrite clamps that were placed on the serial cable, the Ethernet cable, and all accessible interconnecting IO cables in order to pass Radiated Emissions Class B Page 6 of 14

Test Summary Table Immunity Standards IEC 61000-6-1:2005: Generic Standards Immunity for Industrial Environments IEC 61000-4-2: Electrostatic Discharge (ESD) IEC 61000-4-3: Radiated, Radio Frequency, Electromagnetic Field Immunity Test IEC 61000-4-4: Electrical Fast Transient/Burst Immunity Test (EFT) IEC 61000-4-5: Surge Immunity Test (Mains) IEC 61000-4-6: Immunity to Conducted Disturbances, Induced by Radio Frequency Fields IEC 61000-4-8: Power Frequency Magnetic Field Immunity Test IEC 61000-4-11: Voltage Dips, Short Interruptions and Voltage Variations Immunity Test Emissions Standards IEC 61000-6-3:2006: Generic Standard Emission standard for industrial environments CISPR 11 Radiated Emissions CISPR 11 Conducted Emissions Pass, Fail N/A PASS PASS PASS N/A N/A N/A N/A N/A Pass, Fail N/A PASS PASS N/A Comments Test determined not applicable by manufacturer Test determined not applicable by manufacturer Test determined not applicable by manufacturer Test determined not applicable by manufacturer Test determined not applicable by manufacturer Comments Test determined not applicable by manufacturer Performance Criteria Applied: 4.1 Performance Criterion A EUT continues to operate during and after the test 4.2 Performance Criterion B EUT continues to operate after the test 4.3 Performance Criterion C Temporary loss of function allowed, provided the function is self-recoverable or can be restored by the operation of the controls Page 7 of 14

Radiated Emissions Name of Test: Radiated Emissions Engineer: Alex Macon Test Equipment Utilized i00033, i00267 Test Date: 5/16/2013 Test Setup Photos Front Close Up Page 8 of 14

Measurement Results Measurement Distance (D), m = X 3 10 Frequency of Tests, MHz = 30 to 1000 Note 1: Note 2: Worst case of horizontal or vertical. The applied correction factors include transducer factors, cable loss, and distance correction. The EUT meets radiated disturbance limits for: X 61000-6-3 Table 1, Enclosure Port Limits @ 10m Frequency Range Limit (Quasi-peak) 30MHz to 230MHz 30 dbµv/m 230MHz to 1000MHz 37 dbµv/m Radiated Emissions Test Results Emission Freq (MHz) Measured Value (dbuv/m) Corr Factor (db) Corr Value (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Polarity (V/H) Antenna Height (cm) Turntable Position (deg) 72.020 29.720-2.941 26.779 30-2.771 V 98 108 72.004 23.060-2.943 20.117 30-9.433 H 98 108 120.027 27.710 2.27 29.98 30 -.02 V 98 361 168.025 25.520 1.139 26.659 30-3.341 V 98 361 216.015 27.980.928 28.908 30-1.092 V 97 202 471.744 10.040 9.123 19.163 37-17.837 V 98 361 960.002 17.710 16.74 34.45 37-2.55 V 167 57 All other emissions in the required measurement range were more than 20 db below the required limits Page 9 of 14

Electro-Static Discharge Name of Test: Electro-Static Discharge Engineer: Alex Macon Test Equipment Utilized: i00282, i00320, i00357, i00362 Test Date: 5/23/2013 Temperature: 26.5 C Humidity: 34% Pressure: 963.8 mbar Test Setup Photos Side View Close Up View Measurement Information Note: ESD was applied to all exposed surfaces of the EUT, except where the user documentation specifically indicated a requirement for appropriate protective measures. Page 10 of 14

ESD Test Results Contact Discharge 1 2 3 4 Location 2kV 4kV 6kV 8kV 10 + 10-10 + 10-10 + 10-10 + 10 - Pass Pass Pass Pass N/A N/A N/A N/A Serial cable shield Pass Pass Pass Pass N/A N/A N/A N/A Corner of metal case Horizontal Coupling Plane 1 2kV 2 4kV 3 6kV 4 8kV 10 + 10-10 + 10-10 + 10-10 + 10 - Pass Pass Pass Pass N/A N/A N/A N/A Front Pass Pass Pass Pass N/A N/A N/A N/A Back Pass Pass Pass Pass N/A N/A N/A N/A Left Pass Pass Pass Pass N/A N/A N/A N/A Right Location Vertical Coupling Plane 1 2kV 2 4kV 3 6kV 4 8kV 10 + 10-10 + 10-10 + 10-10 + 10 - Pass Pass Pass Pass N/A N/A N/A N/A Front Pass Pass Pass Pass N/A N/A N/A N/A Back Pass Pass Pass Pass N/A N/A N/A N/A Left Pass Pass Pass Pass N/A N/A N/A N/A Right Location Air Discharge 1 2 3 4 2kV 4kV 8kV 15kV Location 10 + 10-10 + 10-10 + 10-10 + 10 - Pass Pass Pass Pass Pass Pass N/A N/A Ethernet Cable Pass Pass Pass Pass Pass Pass N/A N/A Serial Cable Pass Pass Pass Pass Pass Pass N/A N/A USB Drive Pass Pass Pass Pass Pass Pass N/A N/A P1 P10 connector heads Criteria Met A Remark There was not any degradation of performance noted Page 11 of 14

Radio Frequency, Electromagnetic Field Immunity Name of Test: Radio Frequency, Electromagnetic Field Immunity Engineer: Alex Macon Test Equipment Utilized i00266, i00280, i00310, i00320 Test Date: 5/13/2013 Test Setup Photos Front View Back View Page 12 of 14

Test Results Criteria Met Freq. Range (MHz) Test Level (V/m) Polarization (V/H) Orientation (Degrees) A 80-1000 3 Vertical 0 Comment A 80-1000 3 Vertical 90 A 80-1000 3 Vertical 180 A 80-1000 3 Vertical 270 A 80-1000 3 Horizontal 0 A 80-1000 3 Horizontal 90 A 80-1000 3 Horizontal 180 A 80-1000 3 Horizontal 270 A 1000-2700 3 Vertical 0 A 1000-2700 3 Vertical 90 A 1000-2700 3 Vertical 180 A 1000-2700 3 Vertical 270 A 1000-2700 3 Horizontal 0 A 1000-2700 3 Horizontal 90 A 1000-2700 3 Horizontal 180 A 1000-2700 3 Horizontal 270 Note: No degradation of performance was noted. (See comments above for degradation specifics) Page 13 of 14

Test Equipment Utilized Description Manufacturer Model # CT Asset # Last Cal Date Cal Due Date EMI Receiver HP 8546A i00033 12/27/12 12/27/13 Signal Generator Rohde & Schwarz SMT03 i00266 1/7/13 1/7/14 Bi-Log Antenna Schaffner CBL611C i00267 12/19/11 12/19/13 Semi-Anechoic Chamber CT N/A i00276 8/31/11 8/31/13 Antenna Amplifier Research AT5080 i00280 8/31/11 8/31/13 Humidity / Temp Meter Newport IBTHX-W-5 i00282 12/04/12 12/04/13 RF Amplifier EMPower 2024 BBS1C4ALP i00310 8/31/11 8/31/13 Voltmeter Fluke 75III i00320 2/1/13 2/1/14 ESD Simulator Thermo Scientific MZ-30 i00357 6/8/12 6/8/13 A/C Power Source Behlman BL 6000 i00362 Verified on: 5/23/13 Labview Software National Instruments FCC_PART15AB_R2 i00395 Verified on:06/11 Humidity / Temp Meter Omega RH-81 i00408 4/15/13 4/15/15 In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the described equipment. Prior to testing these components were tested to verify proper operation. END OF TEST REPORT Page 14 of 14