Retrofit Kit Manual. Low Energy Operator



Similar documents
Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

Magnum IV Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

TS93 EMR T/PT/TDE. Surface applied door closer

Model 2300DR Installation Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

758 Heavy-duty Ratchet Guy Wire Cutter

Step 1. Item 6. Item 1

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

AUTOMATIC SWINGING DOOR

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

INSTALLATION INSTRUCTIONS

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

DORMA ED 800 SERIES Service Manual

GPS AutoSteer System Installation Manual

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

HT-0095 Mini PV Receptacles AWG Crimping Hand Tool. Tool P/N HT-0095

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

AMERBRITE UNDERWATER WHITE LED POOL LAMP

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

INSTALLATION INSTRUCTIONS

Premier & Deluxe 3-Season Room Sliding Glass Door

HMI display Installation Guide

HOLLISTER-WHITNEY ROPE GRIPPER

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Series Hose Reels

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Installation Instructions K900 series Door Closer

OWNER S MANUAL Table Tennis Table Patent Pending

Model 201 Wiegand Touchpad Reader Installation Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K

OPL BASIC. Dosing System for Professional Laundry machines. Contents

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

8900 EMR (WITH DETECTOR)

Allen-Bradley HP AC Line Filter Kit

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

LIEBERT VNSA Installation Sheet

Advantium 2 Plus Alarm

Your safety and the safety of others are very important.

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Installation and Operation Guide for PD4100 Series Power Control Centers

SYSTEM 4C. C R H Electronics Design

PRODUCT MANUAL - M090

SYSTEM 45. C R H Electronics Design

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

12-Volt Negative Ground Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Installation and Operation Guide for PD4000 Series Power Control Center

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

9.23 Treadmill Treadmill

AUTOMATIC SWINGING DOOR

INSTALLATION INSTRUCTIONS

Wiper Motor Marinco 2.5. Installation Instructions

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Single Station Remote Alarm

Cooktop Low-Profile Ventilation Hoods

OWNER'S MANUAL SIGNAL COMMANDER

Quickie Rhapsody Service Manual

Operation and Installation Manual

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

ASSEMBLY MANUAL SE-4S35

T7560A,B,C Digital Wall Module

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Architect/Contractor Information Package

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Machine Safety Switches

This page is subject to proprietary rights statement on last page

Original Assembly Guide

Section M POWER LIFTS

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

TROUBLESHOOTING GUIDE

INSTALLATION INSTRUCTIONS

Automatic Door Selection Guide

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Remote Access System Installation


Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

Operating Instructions

Swing Door Opener MODEL: DM-50 / DM

9300BC SERIES Light Commercial Door Closer

S&G Model 2937 Group 1 Combination Lock

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Operating Instructions

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

Transcription:

G Y R O T E C H ENTRANCES Inc. S82 W18717 Gemini Drive P.O. Box 906 Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 www.nabcoentrances.com Automatic Entrance Systems Retrofit Kit Manual Model 710 Swing Door System Low Energy Operator Model 710 Swing Door System Magnum Board IV. Retrofit kit (Old Casting) DN0011 WARNING Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings, Installation and Operating Instructions contained in this manual. Failure to do so may result in property damage, or bodily injury. Part Number 15-10677 August 23, 2004 Revision INSTALLATION MANUAL ENTRANCES INC 877-622-2694 www.nabcoentrances.com

CAUTION: Read these safety practices before installing, operating or servicing the automatic door. Failure to follow these practices may result in serious consequences. Read, study and understand the operating instructions contained in or referenced in this manual before operating. If you do not understand the instruction, ask the installing qualified technician to teach you how to use the door. This manual and the owners manual must be given to and retained by the purchasing facility or end user. 1. If the door appears broken or does not seem to work correctly, it should be immediately removed from service and a qualified service technician contacted for corrective action. 2. Disconnect power at the fused disconnect during all electrical or mechanical service. When uncertain whether power supply is disconnected, always verify using a voltmeter. 3. All electrical troubleshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes. 4. It is the responsibility of the installing door technician to install all warning and instructional labels in accordance with ANSI A156.19. 5. It is the responsibility of the purchasing facility or end user to keep warning and instructional labels and literature legible, intact and with the door. 6. Replacement labels and literature may be obtained from local Entrances Inc. distributors. If the name of the local distributor is unknown, contact Entrances Inc. at (877-622-2694) for assistance. 7. Do not place finger or uninsulated tools inside the electrical control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 2 -

Contents Model 710 Swing Door System Overview 4 Specifications 5 Handing Requirements 6 Hardware Kit List 7~8 Magnet Assembly 9 Single Door Conversion 10 Simultaneous Pair Conversion 11 Hydraulic Closer 12 Hydraulic Closer Adjustment 13 Setting Back Check and Door Closed es 14~18 Simultaneous Pair Installations 19 Control es 19 Signage 19 Troubleshooting 20 ANSI/BHMA Specs. 21-22 ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 3 -

To The Installer Model 710 Swing Door System The purpose of this manual is to familiarize the purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the purchaser s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI Standard 156.19 usually covers this type of door. Other local standards or codes may apply. Use them in addition to the ANSI Standard. The GT 710 is listed with the Underwriters Laboratory and is identified as such on the label. Instruct the building owners/operator on the essentials of the operation of the door and this device. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, trained technicians. Overview Earlier version of the GT710 can be retrofitted with the newer Magnum Control Board (Magnum IV). This combination offers several control features that accommodate most installations. This Manual offers step-by-step instructions on how to upgrade an existing GT710 installation with the Magnum IV and related hardware. DN0036 Figure 1 Overview of GT710 with Magnum IV ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 4 -

Table 1 Comparison of Magnum IV to the original GT710 Controller Magnum IV Board Adjustable opening speed. Adjustable current limit/door block trip. Adjustable activation timer (0 to 60 seconds) Adjustable separate push-n-go timer (0 to 60 seconds) Adjustable door action when detection (continuous safety) occurs allow door to stop, creep open or creep closed. Automatic shut-off of motor if door does not open within 30 seconds. Connection provided for swing side mats and swing side presence detector (Continuous safety and safety with lockout). Enable/disable sequential operation via dip switch. Enable/disable push-n-go via dip switch. GT710 Controller Adjustable opening speed. Adjustable current limit/door block trip. One adjustable timer for activation and push-n-go (0 to 60 seconds) None No adjustment. Shut-off occurs when the timer for activation expired. N/A Enable/disable sequential operation via onboard jumper. Wiring change required to activate push-n-go. Specifications Power Input Available current for Accessories Available Wire Size for Incoming Power Minimum Frame Face for Mounting Minimum Clearance from Top of Door to Ceiling Door Hinge Requirements Door Thickness Door Width 120 (±10%) AC 50-60 Hz, 5 Amps 0.5 Amps 24 Volts AC 14 AWG 1 ¾ (44 mm) 7 (178 mm) ¾ Butt, Offset Pivot, or Center Pivot 1 ¾ (44 mm) Minimum Specify When Ordering Tools required 5/32 Hex Key (Allen Wrench) Phillips Screwdriver #2 Slotted Screwdrivers, Small and Medium Drill Bits: 11/64 and 7/8 ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 5 -

Handing Requirements The type of door will determine whether a left-hand or a right-hand operator is required. Figure 2 can be used to determine which unit is required. RIGHT HAND OUT-SWING (RH) LEFT HAND OUT-SWING (LH) LEFT HAND IN-SWING (LH) RIGHT HAND IN-SWING (RH) DN0015 Figure 2 Determine the Swing (Hand) of the Door. Note: The hand of the unit and the hand of the door must be the same. The hand of the unit is not reversible and cannot be converted in the field. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 6 -

Hardware Kit List This kit has been shipped with the following installation hardware. MAGNUM IV RETRO FIT for SINGLE P/N 11-10361-01 MAGNUM IV RETRO FIT for SIM.PAIR P/N 11-10361-02 Part # Part Description Single All items (#1~#24) would be packed into 8 x6 x6 box (P/N 14-1159). 1 24-9800-04 Magnum IV Control Board 1 2 Qty Model 710 Swing Door System Sim- Pair Notes 2 22-10065 Main Harness - Single 1 --- With Terminal Block 3 22-10270 Main Harness Simultaneous Pair --- 1 With Terminal Block 4 11-10286 Motor Harness 1 2 Four Pin Connector 5 21-9933 Power Harness - Single 1 --- 6 14-5883 Power Harness Simultaneous Pair --- 1 7 11-10272 Rocker Assy 1 1 No connector 8 21-9941-01 Magnetic Assy - RH --- 1 9 21-9941-02 Magnetic Assy - LH --- 1 10 21-10005 Magnetic Plate Assy 1 --- 11 14-9940-01 Label for RH Operator 1 --- 12 14-9940-02 Label for LH Operator 1 --- 13 15-10677 GT710 Retrofit Kit Manual 1 1 Use one of Labels. Packed into a 3 x4 ziplock bag (P/N 14-0828-01). 14 14-9944 Epoxy Package & Stir Stick 1 2 Packed into a 4 x6 ziplock bag (P/N 14-0828-03). 15 14-9960 Wire Saddle 3 6 16 24-1447 Wire Harness Clip 4 8 17 14-9959 Cable Clamp --- 4 18 14-9943 Ceramic Magnet 2 4 19 14-8743 Spacer for Magnum Board 4 8 20 14-1218 Wire Nut 2 4 21 14-1838 Male Pin Housing, 4 circuit 1 --- For Magnetic 22 24-0011-014 #10-32x1/2 Phillips Black Oxide 2 2 For Rocker Screw 23 24-4941-19 3/8-16x3/4 Hex Washer Head Screw, 2 4 For Magnetic F 24 24-0010-01 #10-24x7/8 Socket Head Cap Screw 4 8 For Magnum Board ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 7 -

O F F 3 4 Model 710 Swing Door System R2 R3 R4 R5 R6 R7 R8 F1 STOP OPEN BCHK TDAS TDPG LCHK CLOSE On AUX PWR J2 AC IN J4 Fuse 2: 0.5A 24 VAC TRANSFORMER CAPACITOR F2 RELAY SW1 1 2 SW2 LED R28 CURRENT LIMIT RELAY SIGNAL INPUT J1 MOTOR J5 Motor Harness P/N 11-10286 Off Off Hold Open Fuse 1: 3A 120/240 MAGNUM IV Magnum IV Board P/N 24-9800-04 1 Rocker Assy. P/N 11-10272 Main Harness - Single P/N 22-10065 Power Harness - Single P/N 21-9933 Main Harness - Sim. Pair P/N 22-10270 Power Harness - Sim.Pair P/N 14-5883 Epoxy and Stir Stick Epoxy & Stir Stick P/N 14-9944 Wire Saddle P/N 14-9960 Wire Nut (2) Ceramic Magnet P/N 14-9943 Spacer for Magnum Board P/N 14-8743 Wire Nut P/N 14-1218 #10-32x1/2" Phillips Head Black Oxide Screw P/N 24-0011-014 3/8-16x3/4" Hex Washer Head Screw, Type F P/N 24-4941-19 #10-24x7/8" Socket Head Cap Screw P/N 24-0010-01 DN0037 Cable Clamp P/N 14-9959 Wire Harness Clip P/N 24-1447 Male Pin Housing 4 circuit P/N 14-1838 Figure 3 Installation Hardware ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 8 -

Door Closed 4 3 2 1 For RIGHT HAND Units Mounting Magnetic subassy R/L 5/16-18 x 3/4" Hex Washer Head, Type F P/N 24-4941-19 Magnetic Right Hand P/N 21-9941-01 Back Check Back Check 4 3 2 1 For LEFT HAND Units Magnetic Left Hand P/N 21-9941-02 Door Closed Figure 4 Magnetic assembly ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 9 - DN0038

SINGLE DOOR CONVERSION of GT710 WIRE Hrness Clip P/N 24-1447 MAGNUM IV BOARD P/N 24-8900-04 into the Clip. 1. Insert wires 2. Push the Clip into the Extrusion. MAIN HARNESS P/N 22-10065 DN0039 SCREWS & SPACERS P/N 24-4941-16 & 14-8743 WIRE SADDLE P/N 14-9960 Figure 5 Single Door Conversion of GT710 ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 10 -

DN0040 WIRE HARNESS CLIP P/N 24-1447 SCREWS & SPACERS P/N 24-4941-16 & 14-8743 CABLE CLAMP P/N 14-9959 SIMULTANEOUS PAIR POWER HARNESS P/N 14-5883 MAGNUM IV BOARD P/N 24-8900-04 WIRE HARNESS CLIP P/N 24-1447 MAIN HARNESS P/N 22-10065 WIRE SADLE P/N 14-9960 SIMULTANEOUS PAIR DOOR CONVERSION of GT710 (SIDE BY SIDE CONTROL) Figure 6 Simultaneous Pair Door Conversion of GT710 ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 11 -

Hydraulic Closer The door closer has an adjustment for opening force when the doors is used in a manual mode that is preset at the factory. The setting is based on a 30-inch exterior door and a 38-inch interior door. Adjustments are made using an allen wrench as shown in Figure 7. Turn the screw clockwise for larger doors and counterclockwise for smaller doors. DN0032 C.W. Figure 7 Hydraulic Closer. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 12 -

R Model 710 Swing Door System Door Closing Adjustment Procedure The hydraulic closer must be operating properly BEFORE the Magnum control is adjusted. Warning: Improperly installed or adjusted closers may cause property damage or personal injury. Please follow these instructions carefully. Do not allow the door to slam into the frame. A normal closing time from a 90º open position is five to seven seconds, evenly divided between main swing speed and latch swing speed. Use the furnished hex key to adjust speed. 1. Remove one lead from the motor. 2. Adjust the main and latch speeds. To slow MAIN SPEED of door, turn the main speed screw clockwise. To slow LATCH SPEED of door, turn the latch speed screw clockwise. 3. Reconnect motor lead. Note: It may be necessary to rotate the output shaft with the arm to align the holes in the large sprocket with the access holes in the header. LCN Adjustment LATCH SPEED MAIN SPEED BACK CHECK Pedestrian Door Operator For Commercial or Industrial Use Commande de porte pietonniere a usage commercial ou industriel Model No. R LISTED in Pedestrian Commercial & Industrial Manufactured 501 S Max Amps 115 Volts 60 Hz S82 W18717 Gemini Drive Muskego, WI 53150 USA TL DN0041 Figure 8 Hydraulic Closer Adjustment. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 13 -

Setting Back Check and Door Closed es Model 710 Swing Door System The GT 710 has two magnetic switches that control the back check location and monitors the door closed position. The back check magnet must be installed before the unit is tested. It signals the motor to slow down so the door does not slam open. The door closed magnet is optional. It is used to signal the control board that the door is closed. It is used in applications where a sensor is on the swing side of the door and wired into the safety with lockout circuit. The switches are closed by magnets installed by the installer onto the main sprocket gear. The magnets are not inside the header! Locate the ¼-inch square and 1-inch long magnets in the parts bag. To position the magnets, use the appropriate configuration from Figures 10 through 13. Start with the door in the closed position. Place a magnet under the door closed switch with the white side up. This magnet will deactivate the optional presence detector as the door begins to open. Move the door to the 45º position. Place a magnet under the back check switch with the white side up. The magnet is positioned to move under the switch when the door is opened to 45º. Use the appropriate configuration from Figures 10 through 13. This magnet will command the motor to reduce the door speed to the setting of the back check potentiometer. Improper placement of this magnet will cause the door to slam into the door stop. After power is applied to the unit and the position of the magnets is fine tuned to make the door functional, the magnets should be epoxied in place following the instructions on the epoxy packaging. Full Open Back check Main speed Closed Latch Check DN0035 Figure 9 Stages of Door Travel ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 14 -

DOOR OPEN 45 Left Hand Outswing When door is open 45, magnets should end up in positions shown. DOOR CLOSED Model 710 Swing Door System Door Closed Back Check Door Closed Back Check Rotation With door in the closed position, place magnets "White Side Up" in positions shown. DN0042 Figure 10 Left Hand Outswing ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 15 -

DOOR OPEN 45 Right Hand Outswing When door is open 45, magnets should end up in positions shown. DOOR CLOSED Figure 11 Right Hand Outswing Door Shown Door Closed Back Check Door Closed Back Check With door in closed position, Rotation place magnets "White Side Up" in positions shown. DN0043 ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 16 -

DOOR CLOSED When door is at 45, magnets should end up in positions shown. DOOR AT 45 Door Closed Back Check With door in closed position, place magnets "White Side Up" in positions shown. Back Check Door Closed Right Hand Inswing Figure 12 Right Hand Inswing Door Shown. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 17 - DN0044

DOOR CLOSED DOOR AT 45 With door in closed position, place magnets "White Side Up" in positions shown. When door is at 45, magnets should end up in positions shown. Back Check Door Closed Left Hand Inswing Back Check Door Closed Figure 13 Left Hand Door Inswing Shown ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 18 - DN0045

Simultaneous Pair Installations Control es Signage The installer first has to configure each of the doors independently with the speeds and timing desired. Then adjust the potentiometers on the door controller to closely mimic those settings. An ON-OFF-HOLD OPEN switch assembly has been provided in the harness. It can be mounted inside the header or where it is easily accessible to the customer. Drill a 7/8 diameter hole in the center of the location to install the switch. Use the switch as a template to drill (2) 11/64 diameter mounting holes. Use the two screws provided to mount the switch. It the switch assembly is not desired, replace it with jumper from the parts bag. After the door has been adjusted properly and tested, decals should be applied to the door such that they are visible from either side of the door. Depending on the type of the door activation, certain decals must be displayed. Refer to Section 6 of ANSI A156.19 Standard for Power Assist and Lower Energy Power Operated Doors. Decals have been provided with the GT 710 to comply with all the installation applications described in ANSI A156.19. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 19 -

Troubleshooting Symptom Action/Cause Solution Operator does not function. 1. Check Fuse 2 (F2). 1. Replace fuse. 2. Check for 120 VAC at connector J5. 2. Check incoming power. If power is good, check connection to motor. Replace motor if necessary. 3. Check power to activation device at 3. If current exceeds 0.5 amps at 24 VAC, replace with lower draw sensor. connector J2. 4. If blown, replace fuse. 4. Check Fuse 1 (F1). If F1 is OK, check power to activating devices at J2. Voltage is too low, reduce accessory load. Adjustment of Hydraulic Check 4 pin motor connector on Pin #2 and #4 must be jumped by a wire. Closer has no effect. the board. Door slams closed. Main speed on hydraulic closer Turn main speed in direction of turtle. not adjusted properly. Door slams open. Back check speed not adjusted Adjust back check potentiometer or relocate magnet. or magnet not in proper location. Fuse 1 (F1) blows when door open is triggered. Check door activation device power consumption. If current draw exceeds 0.5 amps at 24 VAC, replace with lower draw sensor. Door moves in wrong Check polarity of motor input Reverse motor leads. direction. Back check adjustment on Magnum board has no effect. Unit leaks oil. No back check or motor continues to drive after door is closed. Door does not stay tightly closed. Safety or Presence Sensor does not function. Safety or Presence Sensor is activated by closing door. Floor mat, holding beams or other accessories do not function while door is moving. Sensor shows activation signal sent, but door does not open. One sensor does not activate both doors on a simultaneous pair. wires at connector on motor. The fully open door position is greater than 90º and the back check adjustment on the hydraulic closer is overriding the controls of the Magnum board. Adjusting screws on hydraulic closer have been removed. Magnets on main sprocket not in correct position. 1. Preload on swing arm is not correct. 2. Building stack pressure is excessive. No power to sensor or defective sensor. Connection of sensor to wiring harness was to Safety not Safety w/lockout. Connection of accessories was made to Safety w/lockout not Safety. Sensor not connected properly to activation connector. Sensor is not connected to both control boards. Adjust the back check screw on the bottom of the header out one turn. Replace hydraulic closer. Follow instructions on Page 14 to properly align magnets. 1. Position arm 45º as shown on Figures 11 through 14. 2. Upgrade operator unit to GT 500. Check harness wiring to wire diagram on Page 21. Rewire Safety Sensor to Safety w/lockout connector. Rewire accessory to Safety connection. Check harness wiring to wiring diagram on Page 21. Install simultaneous pair harness (P/N 2210270). ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 20 -

Appendix A Model 710 Swing Door System EXCERPTS FROM ANSI/BHMA A156.19 1997 4.0 REQUIREMENTS FOR LOW ENERGY SWINGING POWER OPERATED DOORS OR LOW ENERGY SWINGING POWER OPEN DOORS 4.1 Opening Time 4.1.1 Doors shall be field adjusted so that opening time to back check or 80 degrees, which ever occurs first, shall be 3 seconds or longer as required in Table 1. Back check shall not occur before 60 degrees opening. 4.1.2 Total opening time to fully open shall be 4 seconds or longer. 4.2 Closing Time 4.2.1 Doors shall be field adjusted to close from 90 degrees to 10 degrees in 3 seconds or longer as required in Table 1. 4.2.2 Doors shall be field adjusted to close from 10 degrees to fully closed in not less than 1.5 seconds. 4.3 The door shall be field adjusted to remain fully open for not less than 5 seconds unless a sensing device is used to hold the door open. 4.4 The force required to prevent a stopped door from opening or closing shall not exceed a 15 lbf (67 N) applied 1 in (25 mm) from the latch edge of the door at any point in the opening or closing cycle. 4.5 The kinetic energy of a door in motion shall not exceed 1.25 lbf-ft (1.69 Nm). Table 1 provides speed settings for various widths and weights of doors for obtaining results complying with this paragraph. 4.6 In the event of power failure to the operator, doors shall open with a manual force not to exceed a 15 lbf (67 N) or torque of 40 lbf-in (4.5 Nm) to release a latch, a 30 lbf (133 N) to set the door in motion, and a 15 lbf (67 N) to fully open the door. The forces shall be applied at 1 (25 mm) from the latch edge of the door. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 21 -

Table 1 Minimum Opening Time to Back Check or 80 degrees, which ever occurs first, or Minimum Closing time from 90 degrees to Latch Check or 10 degrees. Back check shall not occur before 60 degree opening. D = Door Leaf Width in W = Door Weight in Pounds (kg) Inches (mm) 100 (45.4) 125 (56.7) 150 (68.0) 175 (79.4) 200 (90.7) 30 (762) 3.0* 3.0 3.0 3.0 3.5 36 (914) 3.0 3.5 3.5 4.0 4.0 42 (1067) 3.5 4.0 4.0 4.5 4.5 48 (1219) 4.0 4.5 4.5 5.0 5.5 Matrix values are in seconds. Doors of weights and widths can be calculated using the formula: T D W 133 lbf ft T D W 2260 Nm WHERE: T = Time, seconds D = Door width, inches (mm) W = Door weight, lbs (kg) The values for T time have been rounded up to the nearest half second. These values are based on kinetic energy of 1.25 lbf-ft. The value for the 30 inch wide, 100 pound door actually calculates to 2.5 seconds with rounding. 3.0 seconds was used as a more conservative value. ENTRANCES INC 877-622-2694 www.nabcoentrances.com - 22 -