BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS



Similar documents
plumbing products guide

Confort 26. Sliding Systems. Sapa Building System

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Fire Resistant Systems

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Mistrale. Fusion Terminal

Plaisance 50. Windows and doors. Sapa Building System

Avantis 75. Windows & Doors. Sapa Building System

Plaisance 24. Sliding Systems. Sapa Building System

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Rochdale Building Control Guide. Approved Document F Means of ventilation

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Under sill units. Type FSL-B-ZAS

CDW Systems Ltd Contemporary Doors & Windows

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Installation Detailed installation instructions are provided which should be strictly followed.

The complete answer to secondary glazing. High performance secondary glazing solutions for new and refurbished buildings

DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE

sound reduction systems for commercial, educational and industrial environments

K17.12 Door closers K17. Doors

Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Permanent Ventilators (for the Supply of Combustion

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

The Warm Edge for insulating glass

Technical Bulletin 005(A) Developed with Communities and Local Government

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

Rockwool Cladding Roll

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

HDA

AND MEMBRANES ROOFING UNDERLAYS.

Confort 160. Sliding Systems. Sapa Building System

Grilles & Diffusers Series LFP Incorporating

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

How To Make A Supply Air Ceiling

K17.11 DOOR BOLTS K17 DOORS

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

HINGES FOR OUTWARD OPENING APPLICATIONS. Friction Hinges. Parts Brochure

Energy Company Obligation (ECO): Technical Monitoring Questions

REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. Building Solutions Automotive Industry

Energy Efficiency HOSPITALITY.

Replacement Windows and Doors

Sash Window Specialist

Installation and Operating Guide LOOVENT eco Centrifugal Fans (SELV versions)

Part H DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes

Guide to the safe installation of downlighters in dwellings

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

CELO5. User & Installation Manual.

Conservatory Roof Structural Information Guide

DOCUMENT. Introduction WG2/01 SEPTEMBER Future CE marking requirements

SIP (STRUCTURAL INSULATED PANEL)

ECO-VENTILATION Single-room energy recovery ventilators

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Installation Instructions

ECOCIAT. Domestic hot water heat recovery unit

Energy Efficient Windows

Supplying. your home with. Our wall-mounted ventilator range: flexible, powerful ventilation technology for a healthy environment.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Guidance for Electrical Contractors on Emergency Lighting Legislation

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

RPV - RP - RA air handling units

Passive Fire Protection

Contents. Standard Ventilator ( Screw Fit ) Page 25. Modular Ventilator ( Clip Fit ) Page 30

CADB and CADT-D / DI / DC Series

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Terminal Boxes Series 8146

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Portable Air Conditioner

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Prefabricated building PVC vertical sliding window

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

How To Design A Gas Dryer

39HQ Airovision Air Handling Units

DESIGNED TO PERFORM NEW BUILDING REGULATIONS APPROVED DOCUMENT F: APRIL Always Innovating ESTABLISHED 1955

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

keeping air fresher MaxAir REFRESHINGLY POWERFUL clipsal.com

Energy Efficiency. Bars & RestauRants.

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Window Types and Materials

Manufactured in the UK. KI 800 Series

Architectural composite panels

STB Series Enclosures

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Te c h n i c a l G u i d a n c e D o c u m e n t

How To Buy A Designo Grille

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

How To Get A Passive House

Transcription:

CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS...

PRODUCT RANGE AND OVERVIEW.................................................................................. When people talk about ventilation they think of the extract unit, taking the air out of the building. A ventilation system is more than just extracting air, it also relies on the replacement of the stale air with fresh, clean air. Whether you re using a Passive Stack system, a Mechanical Extract system or even intermittent extract units, the building regulations call for a set amount of background ventilation for each ventilation strategy. To avoid condensation extraction of warm, moist air is not enough, it has to be in conjunction with input of fresh air, yet this is often over looked for a number of different reasons. The fresh air not only creates a fresh atmosphere, it also promotes air movement to ensure that air is circulated around the property. Window vents Window vents are incorporated through the head of the window frame and available with manual or automatic openings (humidity sensitive). Wall vents Wall vents are fitted through the wall and ducted to an outside grille. Available with various manual control mechanisms or automatic openings (humidity sensitive). There are many cases where people have a sufficiently working extract system yet still experience condensation within properties, and the main reason is because of insufficient fresh air. Passivent offer a range of background ventilators to enable fresh air to be input in to a building to ensure a healthy atmosphere and reduce the potential for condensation and mould. Standard and acoustic window and wall vents Passivent standard window and wall vents are designed to allow air to enter the building to provide the stated levels of background ventilation to meet the requirements of Building Regulations. Geometric free areas are shown for Scottish Building Regulations. Passivent acoustic window and wall vents not only provide the stated levels of background ventilation, but also noise attenuation for buildings which may be situated where external noise could pose a disturbance to the occupant. Ventilation Geometric Acoustic performance Page Equivalent area Free area STANDARD WINDOW VENTS Ultra Vent 2500 / 4000 / 5000mm 2 2742 / 4465 / 5400mm 2-3 Delta Vent and Grille 1537 / 3074mm 2 2000 / 4000mm 2-4 Energy Saver Humidity Sensivitive 3815mm 2 4000mm 2-4 ACOUSTIC WINDOW VENTS Acoustic Energy Saver Humidity Sensitive 3815mm 2 4000mm 2 39dB 5 Acoustic Low Profile 1777 / 1600mm 2 4400 / 4400mm 2 40-42dB 5 STANDARD WALL VENTS Fresh 80 2220mm 2 4000mm 2-6 Fresh 90 2630mm 2 6000mm 2-6 Fresh 100 3200mm 2 6000mm 2-6 Fresh TLF 2540mm 2 5000mm 2-7 Fresh 99H 3350mm 2 6000mm 2-7 ACOUSTIC WALL VENTS Fresh 80dB 2220mm 2 4000mm 2 50dB 8 Fresh 90dB 2630mm 2 6000mm 2 45dB 8 Fresh 100dB 3200mm 2 6000mm 2 42dB 8 Fresh TLF-dB 2540mm 2 5000mm 2 46dB 9 Fresh 99HdB 3350mm 2 6000mm 2 45dB 9.....................................................................................................

................................ STANDARD WINDOW VENTS Ultra Vent and Grille Through frame window ventilator available in three sizes comprises a controllable internal ventilator and matching external canopy grille. Controlled flow of fresh air via two stage opening. External canopy grille provides weather protection and insect ingress grille. 3 sizes available providing 2500mm 2, 4000mm 2 and 5000mm 2 equivalent areas and can be used to meet background ventilation requirements of Building Regulations throughout the UK and Ireland. One of the smallest window ventilators on the market providing up to 5000mm 2 equivalent area. Slim profile of 10mm for the vent. Suitable for a range of slot sizes from 13mm to 17mm. Incoming air is directed upwards to avoid draughts and discomfort. Suitable for PVCu, aluminium and timber windows. Meets worst case requirements of BS 6375-1 for resistance to water penetration. Material Internal vent: Polyester powder coated aluminium with polymer end caps. External grille: Injection moulded polymer with integral fly screen and fixing holes. Colour Bright White RAL 9016 as standard with alternative colours available upon request. External Canopy Grille Air permeability Ultra Vent 5000 achieves 0.25m 3 /hr at 50Pa in the closed position when tested to BS EN 1026: 2000. Internal Vent with two stage opening Water tightness Ultra Vent 5000 achieves 1000Pa pressure with no leakage in the closed position when tested to BS EN 1027: 2000. 25mm 10mm 26.5mm 36mm Specification clause Provide background ventilation to meet Building Regulations by means of window ventilators giving a minimum of *2500/4000/5000mm 2 of either *equivalent or *geometric free area of ventilation (Passivent Ultra Vent TVUV *25/4/5 and Passivent Ultra Grille TVUG *25/5). Ventilators to provide upward directional airflow and to meet worst case requirements of BS 6375: Part 1 for resistance to water penetration. Ventilators available from Passivent Ltd, North Frith Oasts, Hadlow, Kent, TN11 9QU. Tel: 01732 850770, Fax: 01732 850949. Email: projects@passivent.com. *delete as required Equivalent area Product Equivalent Slot size required Dimensions (length x height x width) area (height x width) Internal Vent External Canopy Grille Ultra Vent 2500 2500mm 2 1no x 13-17 x 165mm 235 x 25 x 10mm (TVUV25) 203 x 26.5 x 36mm (TVUG25) Ultra Vent 4000 4000mm 2 2no x 13-17 x 135mm 350 x 25 x 10mm (TVUV4) 373 x 26.5 x 36mm (TVUG5) Ultra Vent 5000 5000mm 2 2no x 13-17 x 162.5mm 405 x 25 x 10mm (TVUV5) 373 x 26.5 x 36mm (TVUG5) Scottish Building Regulations: Geometric free area Product Geometric Slot size required Dimensions (length x height x width) free area (height x width) Internal Vent External Canopy Grille Ultra Vent 2500 2742mm 2 1no x 17 x 165mm 235 x 25 x 10mm 203 x 26.5 x 36mm Ultra Vent 4000 4465mm 2 2no x 17 x 135mm 350 x 25 x 10mm 373 x 26.5 x 36mm Ultra Vent 5000 5400mm 2 2no x 17 x 162.5mm 405 x 25 x 10mm 373 x 26.5 x 36mm.................................................................................. 3

STANDARD WINDOW VENTS......................................................................................... Depth 24mm Delta Vent and Grille Controllable internal vent with matching external grille. Can be used to meet background ventilation requirements of Building Regulations throughout the UK and Republic of Ireland. Allows controlled ingress of fresh air to aid healthy indoor environment and reduce potential for condensation. Directs air upwards avoiding draughts and discomfort. Clearly marked, flush fitting slide control for simple operation. Meets worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration. Easy fitting due to location lugs. Optional pull cord operation where reqired. Material Body: Injection moulded plastic Colour: White or brown as standard Other RAL colours to order Contact us for pricing. Length see table Installed in window frame Slide control Installed on Overglass Vent Bar Product Ventilation Trickle Slot size Length Equivalent area ventilation (height x width) TVDV2 & TVDG2 1537mm 2 250mm 2 1no x 13 x 165mm 190mm TVDV4 & TVDG4 3074mm 2 500mm 2 2no x 13 x 162.5mm 350mm Height 22mm Specification clause Select options required, and insert information where necessary. Provide background ventilation complying with Building Regulations by means of manually operated Delta Vent (*DV2/DV4) window inlet and external Delta Grille (*DG2/DG4) giving equivalent area of *1537/3074mm 2. Delta Grille (DG2/DG4) Ventilators to meet or exceed the worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration. *Delete as required Ventilators and information available from Passivent Limited, North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU. Telephone: 01732 850770, Fax: 01732 850949. Email: projects@passivent.com... Energy Saver Humidity Sensitive Automatic function dependent upon humidity levels in the room. Can be used to meet background ventilation requirements of Building Regs throughout the UK and Republic of Ireland. Minimises unnecessary ingress of cold air. No user input is required, and can help to reduce potential for condensation. Designed for use with Ultra Grille (TVUG5) external canopy grille (see page 3). Automatic, no user input. Uses no electricity or mechanical power. Directs airflow upwards avoiding draughts and discomfort. Energy efficient, minimise heat loss. Height 40mm Depth 30mm Material Body: Injection moulded polystyrene Colour: white, brown or black as standard Other RAL colours to order. Contact us for pricing. Technical Airflow at 20Pa: minimum 7m 3 /hr (closed to trickle), max 40m 3 /hr. Ventilation levels 47% RH - 500mm 2 ventilation area 65% RH - 3815mm 2 ventilation area External Canopy Grille Product Ventilation Slot size Length Equivalent area (height x width) Installed in window frame Energy Saver Vent closed Energy Saver Vent open Specification clause Select options required, and insert information where necessary. Provide background ventilation complying with Building Regulations by means of automatic humidity-controlled internal window ventilators and external grilles giving 3815mm 2 equivalent area of ventilation. Internal vent (Passivent Energy Saver Vent TVES4) to operate between 45% and 60% relative humidity. Ventilators to meet or exceed the worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration in conjunction with specified external grille (Passivent TVUG5). Ventilators and information available from Passivent Limited, North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU. Telephone: 01732 850770, Fax: 01732 850949. Email: projects@passivent.com TVES4 3815mm 2 2no x 13 x 162.5mm 400mm 4..........................................................................................................

.......................................................................................................... Acoustic Energy Saver Humidity Sensitive Humidity sensitive, acoustic through frame window vent. Provides automatic ventilation and sound insulation for use near noise sources. Designed for use with Ultra Grille (TVUG5) external canopy grille (see page 3). Substantial sound reduction. Energy saving, reduces over ventilating. No user input required to control. No mechanical or electrical components. Height 45mm Material Body: Injection moulded polystyrene Colour: White, brown or black. Colour matched to RAL available. Contact us for pricing. Depth 64mm External Canopy Grille Vent open Vent closed Specification clause Select options required, and insert information where necessary. Provide background ventilation complying with Building Regulations by means of automatic humidity-controlled internal window ventilators and external grilles giving 3815mm 2 equivalent area of ventilation. Internal vent (Passivent Energy Saver Vent TVES4) to operate between 47% and 65% relative humidity. Vent to be acoustically treated providing attenuation up to 39dB Dn,e,w. Ventilators to meet or exceed the worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration in conjunction with specified external grille (Passivent TVUG5). Product Ventilation Slot size Length Sound reduction Equivalent area (height x width) up to TVES4dB 3815mm 2 2no x 13 x 162.5mm 420mm 39dB Dn,e,w Ventilators and information available from Passivent Limited, North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU. Telephone: 01732 850770, Fax: 01732 850949. Email: projects@passivent.com... Acoustic Low Profile Acoustic through frame window vent. Low profile design with manual operation. Available in either 450mm or 800mm widths and provides up to 42dB attenuation. Designed for use with Ultra Grille (TVUG5) external canopy grille (see page 3). Substantial sound reduction. Internal filter prevents insect and dust ingress. Simple and easy operation. Meets worst case requirements of BS 6375: Part 1: 2000 for resistance to water. Internal vent easily removed for cleaning. Material Body: Aluminium with polyester paint finish Colour: White or Grey. Colour matched to RAL available. Contact us for pricing. Product Ventilation Slot size Length Sound reduction Equivalent area (height x width) up to TVALdB450 1777mm 2 1no x 13 x 350mm 456mm 40dB Dn,e,w TVALdB800 1600mm 2 1no x 13 x 350mm 806mm 42dB Dn,e,w Specification clause Select options required, and insert information where necessary. Provide background ventilation complying with Building Regulations by means of internal window ventilators giving *1777/1600mm 2 equivalent area of ventilation (Fresh ALdB) to achieve up to *40/42dB Dn,e,w sound reduction. Made of aluminium with ABS end caps. Supplied with dust and insect filter as standard. Ventilators to meet or exceed the worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration in conjunction with specified external grille (Passivent TVUG5). *Delete as required To be supplied by Passivent Limited, North Frith Oasts, Ashes Lane, Hadlow Kent TN11 9QU. Telephone: 01732 850770, Fax: 01732 850949, Email: projects@passivent.com.......................................................................................................... 5

STANDARD WALL VENTS......................................................................................... Fresh 80 Non-electric through wall vent provides controllable background ventilation. ducting and external grille. Manual pull cord operation. Trickle facility possible even when closed to ensure fresh air ingress. Ventilation levels can be controlled to set levels. Fresh 90 Non-electric through wall vent provides controllable background ventilation. ducting and external grille. Manual slider operation, controls internal iris to modulate airflow. Trickle facility possible even when closed to ensure fresh air ingress. Ventilation levels can be controlled to set levels. Fresh 100 Non-electric through wall vent provides controllable background ventilation. ducting and external grille. Manual pull cord operation. Trickle facility possible even when closed to ensure fresh air ingress. Ventilation levels can be controlled to set levels. External grille 115 x 115mm External grille 140 x 140mm External grille 150 x 150mm 138mm diameter x 55mm depth 150 x 150 x 48mm depth 184mm diameter x 56mm depth diameter 86mm. Suitable 360mm as standard (or more to special order). dia. 99mm. Suitable for any wall thickness up to 360mm as standard (or more to special order). diameter 99mm. Suitable 360mm as standard (or more to special order). Product Standard operation Trickle facility Ventilation Airflow rate @10Pa Equivalent area Fresh 80 Manual control via pull cord Yes, 0-2000mm 2 2220mm 2 5.2 l/s Fresh 90 Manual control via slider at bottom of vent Yes, 0-1200mm 2 2630mm 2 9.0 l/s Fresh 100 Manual control via pull cord Yes, 0-2800mm 2 3200mm 2 9.0 l/s Fresh TLF Manual control via slider at bottom of vent No 2540mm 2 8.1 l/s Fresh 99H Humidity control Yes, 0-1200mm 2 3350mm 2 8.1 l/s 6...........................................................................................................

.......................................................................................................... Fresh TLF Non-electric through wall vent provides controllable background ventilation. ducting and external grille. Manual slider operation controls internal iris to regulate airflow. Enhanced aesthetic appearance. Design enhances airflow pattern locations. Fresh 99H Humidity Sensitive Non-electrical, non-mechanical humidity sensitive through wall vent to provide controllable background ventilation. Ventilation increases/decreases as levels of relative humidity increase/decrease. ducting and external grille. Automatic opening and closing dependent upon Relative Humidity (RH) levels. Incorporates manual override if required. Energy saving through reduced heat loss. With manual controlled vents there is the reliance on the user to open and close the vent as required. If they do not use the product as is required, it is possible that dwellings are over or under ventilated. Over ventilating will mean that excess heat is lost, thus requiring more energy from the house heating to warm the space, costing more money. Under ventilating can lead to issues of condensation and possible mould growth. An automatic unit, such as the Fresh 99H opens and closes dependent upon relative humidity, thus reducing the potential for condensation and reducing the amount of heat loss. The product does not require any manual interaction to operate, making ideal for social housing, care homes, hotels and student accomodation. External grille 150 x 150mm 168 x 156mm x 46mm depth External grille 140 x 140mm 140 x 140mm x 60mm depth Material for all models Body: Recyclable ABS. Colour: white External grille terracotta Colour matched to RAL available. Contact us for pricing. diameter 102mm. Suitable 350mm as standard (or more to special order). diameter 99mm. Suitable for any wall thickness up to 350mm as standard (or more to special order). Optional extras for all models Pollen filter Acoustic cowl Storm shield to prevent draughts in windy locations.......................................................................................................... 7

ACOUSTIC WALL VENTS........................................................................................... Fresh 80dB Non-electric acoustic though wall vent, provides controlled background ventilation and noise attenuation up to 50dB Dn,e,w. acoustic ducting and external grille. Substantial sound reduction up to 50dB Dn,e,w. Trickle facility to allow air ingress even when closed. For 300mm wall thickness as standard, longer length available. Fresh 90dB Non-electric acoustic though wall vent, provides controlled background ventilation and noise attenuation up to 45dB Dn,e,w. acoustic ducting and external grille. Sound reduction up to 45dB Dn,e,w. Manual slider operation, controls internal iris to modulate airflow. Trickle facility possible even when closed to ensure fresh air ingress. Ventilation levels can be controlled to set levels. Fresh 100dB Non-electric, acoustic through wall vent provides controllable background ventilation and noise reduction up to 42dB Dn,e,w. acoustic ducting and external grille. Sound reduction up to 42dB Dn,e,w. Manual pull cord operation. Trickle facility possible even when closed to ensure fresh air ingress. External grille 165 x 165mm 138mm diameter x 60mm depth Backplate 165 x 165mm External grille 165 x 165mm 150 x 150mm x 48mm Backplate 165 x 165mm External grille 165 x 165mm 184mm diameter x 65mm depth Backplate 210 x 210mm diameter 140mm. Suitable 300mm as standard (or more to special order) diameter 140mm. Suitable 300mm as standard (or more to special order). diameter 140mm. Suitable 300mm as standard (or more to special order). Product Standard operation Trickle facility Ventilation Airflow rate Sound reduction Equivalent area @10Pa up to Fresh 80dB Manual control via pull cord Yes, 0-2000mm 2 2220mm 2 5.2 l/s 50dB Dn,e,w Fresh 90dB Manual control via slider at bottom of vent Yes, 0-1200mm 2 2630mm 2 9.0 l/s 45dB Dn,e,w Fresh 100dB Manual control via pull cord Yes, 0-2800mm 2 3200mm 2 9.0 l/s 42dB Dn,e,w Fresh TLF-dB Manual control via slider at bottom of vent No 2540mm 2 8.1 l/s 46dB Dn,e,w Fresh 99HdB Humidity control, 45-80% Yes, 0-1200mm 2 3350mm 2 8.1 l/s 45dB Dn,e,w 8..........................................................................................................

................................................................................ Fresh TLF-dB Non-mechanical acoustic through-wall vent provides controllable background ventilation and noise reduction to 46dB Dn,e,w. acoustiv ducting and external grille. Sound reduction up to 46dB Dn,e,w Manual slider operation controls internal iris to regulate airflow. Enhanced aesthetic appearance. Fresh 99HdB Humidity Sensitive Non-electric acoustic, humidity sensitive vent provides background ventilation and noise reduction to 45dB Dn,e,w. Supplied as automatic humidity sensitive internal vent, acoustic ducting and external grille. Sound reduction up to 45dB Dn,e,w Automatic opening and closing dependent upon Relative Humidity (RH) levels. Incorporates manual override if required/desired. The acoustic wall vents reduce the amount of noise ingress from outside, making them suitable for use in applications where there are high levels of external noise such as near main roads, airports or railway lines. diameter 140mm. Suitable 300mm as standard (400mm and more to special order). External grille 180 x 180mm 168 x 156mm x 54mm Backplate 180 x 180mm diameter 140mm. Suitable 300mm as standard (or more to special order). External grille 165 x 165mm 140 x 140mm x 60mm Backplate 165 x 165mm Material for all acoustic models Body: Recyclable ABS Duct: Glass fibre with PVC skin Colour: white External grille terracotta Colour matched to RAL available. Contact us for pricing........................................................................................................... 9

10...................................................................

11

................................................................... FURTHER.............. INFORMATION.................................... The Passivent range of background ventilation can be used to help achieve the background ventilation requirements specified within the necessary building regulations. The range can be used as part of a full house ventilation strategy using our natural and mechanical ventilation systems including: ipsv: Passive Stack ventilation requiring no energy use and no moving parts imev: intelligent mechanical extract ventilation utilising humidity sensitive components to ensure optimal performance Intellivent: decentralised mechanical extract ventilation Mastercare Installer scheme We recommend that installation is carried out by a specialist Passivent Mastercare Installer. The Mastercare scheme, operated by Passivent Limited, comprises well-established and reputable companies who have been fully trained and assessed by Passivent Limited to install any Passivent system in both new build and refurbishment projects. Mastercare provides: Assurance that work is carried out by trained and experienced installers who are familiar with the systems. Quality installations. Compliance with relevant codes of practice. Competitive cost. All Passivent Mastercare Installers hold a certificate from Passivent Limited. They are regularly monitored to ensure standards of work are maintained, and also receive full technical support from Passivent Limited. Quality assurance Passivent products are designed, developed and manufactured under a BS EN ISO 9001 quality management system, giving an independently audited assurance that the products will fulfil their intended purpose. Environment Passivent conducts all business processes under a BS EN ISO 14001 environmental management system, giving an assurance that all activities are carried out having minimal impact on the environment.................................................................... PASSIVENT LIMITED North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU Tel: 01732 850770 Fax: 01732 850949 Email: projects@passivent.com Web: www.passivent.com Passivent Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice. A division of Building Product Design Ltd. Company Registration No; 3944123...... 910158 October 2015 4670