Drives and motors. A guide to using variable-speed drives and motors in car parks



Similar documents
Drives and motors. A guide to using variable-speed drives and motors in data centres

A guide to using variable-speed drives and motors in swimming pool halls

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

Colt ventilation systems for car parks, loading bays and service areas

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

Airmanager Industrial HVAC retrofit results July Location Description:

Creating clean energy from waste Power and automation solutions for waste-to-energy plants

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

ABB drives for water Medium voltage drives for energy savings and life-cycle improvements

Direct Fresh Air Free Cooling of Data Centres

Energy saving technology to deliver the fastest returns. Top 10 energy saving options

Heating, Ventilation and Air Conditioning Rebate Catalog Saving energy for a brighter future

ABB drives and motors for improving energy efficiency

Energy Saving Fact Sheet Air Conditioning

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Fläkt Woods Building Future

State of the Art Energy Efficient Data Centre Air Conditioning

ABB Drive Services Your choice, your future

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

DESIGN CRITERIA AND OPERATIONAL LIMITS FOR AXIAL FLOW FANS OPERATED IN PARALLEL MODE

Rainwater Harvesting

vacon ac drives for mining & minerals

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Heating, ventilation and air conditioning zone controls

HVAC Applications. VFD considerations for HVAC systems...

Case Studies: Infrared Heating in Industrial Applications

Rules of Thumb Energy Efficiency in Buildings

SPECIAL APPLICATIONS

Information Guide Domestic Air Source Heat Pumps

Choosing Between Electromechanical and Fluid Power Linear Actuators in Industrial Systems Design

Saving Energy For Your Organisation. Top 10 energy saving tips

Data Centres A complete solution to noise control and acoustic packages

Centrifugal Fans and Pumps are sized to meet the maximum

Electronic Diesel Control EDC 16

DataCenter 2020: first results for energy-optimization at existing data centers

Infrastructure & Cities Sector

Fire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS

Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications

Energy Saving Fact Sheet Boilers

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

GAS HEATING IN COMMERCIAL PREMISES

Greening your Buildings with Schindler Modernisation

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

On-Demand Ventilation Energy Saving in Industrial Applications

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Power Generation Service Life Cycle Management for Power Plants

Glossary of Heating, Ventilation and Air Conditioning Terms

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

HVAC Processes. Lecture 7

Directorate for the Built Environment Building Standards Division

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Safe Method: Gas Safety in Catering Establishments

EarthCents (DSM) Program Summary

FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Electric Coolant Pumps. Always at the Correct Temperature

How To Design A Gas Dryer

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

Demand Based Static Pressure Reset Control for Laboratories

Introduction. Motor Types

SECTION TESTING, ADJUSTING, AND BALANCING

Energy Performance Certificate

Build Your Own Electric Car Or Truck

Permanent Ventilators (for the Supply of Combustion

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

How To Run A Data Center Efficiently

The World s Leading Duct board Solution Package

Product Data Bulletin

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Cranes Power, Control and Automation application solutions

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Introduction C FANTECH

Your Guide to Buying an Energy-Efficient Central Air Conditioner

UDSA - UDSBD unit heater

Choosing Close-Coupled IT Cooling Solutions

Power and Cooling for Ultra-High Density Racks and Blade Servers

HYBRID POWER SYSTEMS for TELECOM applications

ASTACEA4 Inspect complex/central air conditioning systems

The Mersey Gateway Project

ASSET & FACILITIES MANAGEMENT CORPORATE ENERGY EFFICIENCY POLICY

Thermal Optimisation in the Data Centre

Analog signal converters CC-E I/I Current / current isolators

With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS

Chapter 3.5: Fans and Blowers

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Delivering exceptional performance and Ecovalue. Ecocent

Agenda. Who we are What we do How we serve the BPO Industry

Ventilation Solutions Product Range > Car Park Ventilation, 50Hz

Transcription:

Drives and motors A guide to using variable-speed drives and motors in car parks

Helping car parks meet the energy and CO 2 reduction challenge In the UK, as population density increases and space becomes more of a premium, multi-storey car parks have become an increasingly attractive way of parking vehicles within towns and cities. Multi-storey car parking facilities are now common place in office buildings, shopping complexes and apartment blocks. Car park design has also changed greatly over the years. Previously, car parks were designed as functional buildings offering little aesthetic appeal, but architects and city planners now feel the need for car parks to show more compassion to their surroundings. The result is that car parks are increasingly becoming enclosed buildings and as a consequence, natural ventilation is harder to achieve. As a result ventilation systems have become common place to provide extraction of vehicle fumes and, in the case of a fire, smoke ventilation. Within car parks there are three methods of ventilation 1. Natural ventilation These tend to be above ground car parks with permanent wall openings on each level equal to 5 percent of the net floor area in natural openings, 50 percent of which must be split between opposing walls. These openings provide enough ventilation for smoke clearance and removal of exhaust fumes. Designers also have to take full account of the aerodynamic effect of any barriers across the ventilation openings. 2. Assisted natural ventilation When 5 percent open space is not achievable, but 2.5 percent of the net floor area is available to provide cross ventilation, a reduced rate of ventilation is possible. This is sufficient ventilation for smoke clearance, but in addition a mechanical extract providing three air changes per hour is needed to remove exhaust fumes. 3. Mechanically ventilated Where natural ventilation is not possible, the only option is to provide a mechanical means of ventilation. This needs to achieve six air changes per hour for exhaust fume extract and 10 air changes per hour for smoke clearance. 2 Helping car parks meet the energy and CO 2 reduction challenge l A guide to using variable-speed drives and motors in car parks

Legal requirements The ventilation system for an enclosed car park has two functions: 1. To remove vehicle exhaust fumes, mainly carbon monoxide, during normal car park usage, creating an acceptably air-conditioned environment. 2. To remove the smoke in the event of a fire to assist in providing a safe means of escape. In the UK, the design covering these two functions are set out in detail in Documents B and F of the Building Regulations for England and Wales. Similar recommendations can be found in the technical documents for Scotland. For the UK, the standards currently are: Six air changes per hour, (or ventilation to maintain the CO level < 50 ppm for fume control function) 10 air changes per hour, or a ventilation rate based on the requirements in BRE 368[1], for fire smoke removal Total ventilation duty must be divided between two fans Fans must be capable of surviving a minimum of 300 C for 1 hour Exhaust ductwork system to have extract grilles, 50 percent at high level and 50 percent at low level Attention has to be given to the supply of replacement air Helping car parks meet the energy and CO 2 reduction challenge l A guide to using variable-speed drives and motors in car parks 3

Car park ventilation applications Jet, impulse or induction systems All the above are different names for the same basic system and provide car parks with ventilation by propelling a small jet of air at extremely high velocity, causing the surrounding air to be carried along with it. These systems were originally designed for the extraction of fumes from tunnels but are now commonplace in car parks as they work well in confined areas. The system works by adding momentum to the air and directing it to a pre-designated extraction point ensuring there are no dead spots for fumes and smoke to stagnate and collect. The system offers significant space saving benefits over traditional ductwork systems along with huge energy saving potential, as only a small number of carefully located fans are needed to ensure air movement throughout the car park. Advantages of jet, impulse or induction systems Jet fans take up less space than traditional ducted systems Jet systems are often combined with CO detection so the system begins to extract when pollution levels build up too high running fans in this way saves energy Noise levels are significantly reduced as fans are smaller and run at lower speeds Jet fans cost less than ducted systems Easier for engineers to carry out maintenance Jet, impulse or induction systems with variable-speed drives Many jet systems operate at a constant flow rate; however peak demand may only be required for a small percentage of the day. The conventional response to control air ventilation within car parks is to maintain a fan speed that turns the air over in accordance with building regulations; however there are fluctuations in demand and maintaining a constant fan speed becomes inefficient when car parks are not busy. All car parks will have peaks in demand and consequently demands on the ventilation system will differ accordingly. In traditional systems, fans run at 100 percent at all times and are controlled by throttling arrangements, but this is extremely energy intensive. By controlling fan speed using variable-speed drives, car parks can reduce their overall energy spend. This is achieved by using variable-speed drives on fans to vary air flow, meeting changing load demands more precisely. ABB drives also allow you to adjust a real time clock, without the need for a building management control system. This helps to save money as each drive can be set up independently to activate functions at various times of the day according to the needs of the car park. Traditional ventilation systems Within traditional systems, ductwork is used to remove smoke from the car park. Ducts are evenly spread throughout the car park and also feature at low levels to provide extraction points. Many of these traditional systems were installed during times when vehicle pollution levels where high, yet today with the invention of the catalytic converter and the growing trend of smaller engines, many car park ventilation systems find themselves oversized and as such, can benefit from improvements in ventilation control. Traditional systems tend to make use of vanes and dampers to restrict airflow to individual floors whilst maintaining peak flow in the central HVAC system. However this approach uses considerable energy and equipment lifetime is shortened. A much better approach is to reduce the fan speed in the ventilation system to match the needs of the building. This can be achieved by installing variable-speed drives. 4 Car park ventilation applications that benefit from variable-speed drives l A guide to using variable-speed drives and motors in car parks

Variable-speed drives Car park electricity costs can be significantly reduced by as much as 50 percent with variable-speed drives from ABB. These devices control the flow of pumps and fans to eliminate the energy waste that is common with conventional pump and fan control methods. How variable-speed drives work Many existing fan systems are based on throttling arrangements: the motor is driven at full speed and then the flow of air is regulated by dampers, vanes or similar throttling mechanisms. Throttling the output in this way, wastes energy. A drive can increase the system s efficiency by adjusting the motor speed to the correct operation point and eliminating the need for throttling. A small reduction in speed can make a big difference in energy consumption. A fan running at half speed consumes only one quarter as much energy as a fan running at full speed. This is because the power required to run a fan changes with the cube of the speed. Because many fan systems run at less than full capacity for much of the time, drives can produce huge savings. If a 100 kw fan is throttled by 50 percent, for example, the investment in a drive will have a payback of only six months of continuous operation. Built in CO and CO 2 sensors ABB drives can vary the speed of fans according to how much CO and CO 2 there is in the air. The drives monitor the air with their built-in sensors and adjust the motors accordingly, so air turnover is maintained within safe levels. Controlling motors in this way also allows the fans to be turned down to a minimum when demand for air turnover is low, helping to save energy and reduce electricity costs. ABB drives also allow fan settings to be adjusted from a central point; if one drive is adjusted, the settings are administered throughout the car park, helping to maintain balance within the system. Eliminating harmonic distortion As car parks are fitted with sensitive measuring equipment, it is important that the drives cause as little disturbance as possible to the mains supply to avoid interfering with the instrumentation. Certain ABB drives feature a patented swinging choke that reduces the harmonic signature at low motor speeds, fulfilling the international standard IECEN61000-3-12. The choke adjusts automatically according to the electrical load and circumstances and cuts harmonics, especially at partial loads, for a total reduction of up to 25 percent, compared to traditional choke designs. Car park ventilation applications that benefit from variable-speed drives l A guide to using variable-speed drives and motors in car parks 5

The benefits of variable-speed drives Benefits of variable-speed drives Commercial Reduced energy consumption typically 50 percent Fast payback from 6 months Reduced CO 2 emissions Enhanced Capital Allowance scheme provides businesses with enhanced tax relief for investments in energy saving equipment meeting the Government s published criteria Financing available through the Carbon Trust Fans offer best energy saving potential in car parks eg. applying a variable-speed drive to a 75 kw motor in continuous duty can save nearly 15,000 per year Technical - Lower maintenance costs - Starting, stopping and braking can easily be programmed to reduce stress on mechanical equipment Increases equipment life and reduces maintenance requirements for fans and motors Easily retrofitted into an installation Real-time clock Can easily set up programmes with different running speeds at different times or on different days, making the drive ideal for car park applications Low harmonic solutions available as part of installation design Car park users Clean air circulation throughout critical car park areas Tighter control over CO and CO 2 levels Facilities Manager Gain control of air circulation, eliminate static air pockets Easy to retrofit drive into an installation Help is available ABB provides free energy appraisals that detail the best applications for upgrade and show the savings that can be achieved by installing variable-speed drives and high efficiency motors. A drive and electric motor combination, when used to control the speed of applications such as pumps and fans, can reduce the energy bill by up to 70 percent with a payback in less than 12 months. The 50-person strong Energy Appraisal Team comprises of ABB engineers and selected technical partners, all of whom have extensive practical experience of carrying out energy appraisals over the past 20 years and have attended ABB s intensive energy saving training course, will within half-a-day provide an analysis of the energy saving potential within the motor-driven applications. 6 The benefits of variable-speed drives l A guide to using variable-speed drives and motors in car parks

Practical application ABB variable-speed drives ensure clean air at Q-Park car park Challenge Q-Park s new car park in Sheffield needed to achieve adequate air circulation to provide ventilation and fire safety to the car park s 531 spaces located over its six floors. Solution To ventilate the car park of carbon monoxide and ensure that smoke can be vented in the event of fire, ABB standard drives for HVAC were fitted to two fans to provide air movement within the car park and two fans for extraction, driven by two 1.5 kw and two 4.8 kw drives respectively. The system also monitors carbon monoxide levels in the car park and initiates ventilation when the level rises above recommended levels via an independent control panel providing three, six or ten changes an hour depending on conditions within the car park. Benefits Depending on the number of air changes needed, the drives run at 25, 30, 50, 60 or 100 percent speed. The variablespeed drives enable Q-Park to reduce the speed of the fans, helping to significantly reduce energy spend. As well as the energy saving benefits of only running the ventilation when needed, the drives also have the advantage of soft start, so that the fan motors do not draw a large current on start up. Life cycle services When you choose an ABB drive you automatically become part of the most comprehensive product life cycle management scheme in the industry. The scheme ensures that the required product support is always available and paves the way for a smooth transition to a new product at the end of the life cycle. Pre-purchase ABB provides its customers with help in selecting the right drives and services for their applications. Correct selection and dimensioning ensure improved performance of the entire system. Order and delivery Orders can be placed through ABB s channel partners or through ABB offices. This network ensures timely deliveries from local and central stocks. Installation and commissioning ABB certified engineers can advise or undertake the installation and commissioning of drives. Operation and maintenance ABB helps ensure a long lifetime by providing on-site preventive maintenance. Preventive maintenance consists of annual inspections and component replacements according to the drive specific maintenance schedules. Retrofit and upgrade ABB can advise on the latest hardware and software upgrades that can continue to maximise the performance of your drive. Replacement and recycling ABB can advise on the best replacement drive while ensuring that the existing drive is disposed of in a way that meets the local environmental regulations. Value chain services Throughout the life cycle value chain ABB offer services including: training, technical support and service contracts. Practical application and life cycle services l A guide to using variable-speed drives and motors in car parks 7

Contact us ABB Limited Daresbury Park Daresbury Warrington Cheshire WA4 4BT Tel: +44 (0) 1925 741 111 Fax: +44 (0) 1925 741 212 www.abb.co.uk/energy Notes: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. A guide to using variable-speed drives and motors in car parks/feb 2014 Copyright 2014 ABB All rights reserved Printed in UK (02.2014)