USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family



Similar documents
VIDEO DOOR PHONE SYSTEM

2013 Wireless Video Intercom INSTALLATION GUIDE

24 Wide Screen LED Monitor with HDMI

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

COLOR TFT LCD MONITOR. User Manual

Day / Night IR Color Camera User Manual V2.1.0

User Manual. Video Doorphone CDV-1020AQ

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

16/32 Channel 1U Rack Mount CCTV Power Supply

COLOR VIDEO DOOR PHONE CDV-71BE/D

Features of Your Cisco Unified IP Phone

Dome Camera with IR Night Vision

DS B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK

HP ProDisplay P19A LED Backlit Monitor. User Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Monitors. Platea Monitor

User Manual Color video door phone

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Installation Instructions

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

DALI RC BASIC SO. Control unit Operating instructions

D45. SySTEm. ThE high-performance

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

19 LED Tube Controller ORDERCODE 41003

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Modular I/O System Analog and Digital Interface Modules

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Local supplier shall be ISO 9001 & OHSAS Certified Company.

2M IR Mini Dome Quick Installation Guide

PD 100A. Printing data system

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

HP ProDisplay P17A LED Backlit Monitor. User Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

INSTALLATION INSTRUCTIONS

GSM Door Phone System

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

Product and functional description

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Second Display Installation Guide Point-of-Sale Hardware System

Product and Application Description

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

OPL BASIC. Dosing System for Professional Laundry machines. Contents

IN-OUT Thermometer with Cable Free Sensor and Clock

Adaptability to Enhanced Security

T0118 T2118 T3118. Instruction Manual

Adaptability to Enhanced Security

Sympodium Interactive Pen Display

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Installation, operation and maintenance manual TX 35A

MAGICAR M871A. Car alarm with two-way remote User s guide

User Guide. Model Insulation Tester / Megohmmeter

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Link SIP Door Phone. Manual V1.0. Linkcom France rue du Soleil Levant CLAMART Copyright 2008 Linkcom Tous droit réservés

VFS24/32HDIP. Public Display IP Monitor User Manual

LCD Drawer User Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

VTO6xxx. IP door stations. User manual

SMART Board 685ix interactive whiteboard system Model 685ix

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Security Camera Indoor/Outdoor Color Camera w/ Night Vision

Drayton Digistat +2RF/+3RF

Single Day Alarm Clock with. Bluetooth and USB Play-through

Heating Controller. Building Technologies HVAC Products

PLL2210W LED LCD Monitor

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rack Mount LCD KVM Assembly Installer/User Guide

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

SMART Board interactive flat panel with appliance Model 8055ie-SMP

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

GSM Autodialer Professional GJD700 Speech & Text Autodialer

DMX2PWM 9 Channel Dimmer Setup Manual

CONCIERGE SWITCHBOARD

Radiant Temperature Sensor TY7321

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TFT LCD COLOR MONITOR OPERATION MANUAL

Senses SV series industrial monitor user manual

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Video Kits. For Villas. Rock vandal resistant panel

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

PK5500 v1.1 Installation Instructions

9448 Installation and User Guide

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

ADM1TE 5/30A DIN rail single phase two wire energy meter

SMART Podium Interactive Pen Display

HP EliteDisplay LED Backlit Monitors. User Guide

0311 A OI GT-1C-L/GT-1C. Apartment Intercom System Residential Monitor Station OPERATION MANUAL

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Stove Guard Kit User Manual

15-INCH TFT-LCD MONITOR

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

HP Compaq LE1902x, LE2002x, LE2002xm, and LE2202x LED Backlit LCD Monitors. User Guide

Transcription:

USER MANUAL EN KIT VIDEO DOOR PHONE smart 1 family Harry Johnston Call from the outdoor panel keys; Possibility to see on the terminal's display the person calling ; Duplex hands-free audio communication; Opening command of the access gate/door from the indoor terminal ; Video and audio monitoring of the entrance of the property, by the inhabitant; Optional auxiliary command: auto-access, garage door, etc.; Optional 1 video terminal in paralle l;

Harry Johnston INPUT: ~30V ± 10% / 50 Hz / 0,4 A CAUTION! DO NOT REMOVE THE SAFETY LID! ELECTRICAL SHOCK! 1 KIT COMPONENTS POWER SUPPLY - smart (PS.VDN.ENW) OUTPUT: 8V ± 10% / 1, A RISK OF 1 pc. 94 144 53 mm Indoor terminal 1 pc. 37 1 5 mm Power supply unit 1 pc. 130 141 73 mm TECHNICAL FEATURES OF THE SYSTEM Audio communication Data communication Duplex Digital Video communication Power supply of the system (supply of the control unit) Maximum current consumption from the 30 V AC network Analog video signal 30 V±10% / 50 Hz 0,4 A AC.1 Technical features of the outdoor video panel Power supply Steerable video camera module Infrared illumination 6... 30 V DC (stabilized) - CCD, 1/3, 573(H) x 597(V) pixel resolution; 40 TV Lines; - angle of visualization: 9 horizontal, 45 vertical; - video signal: 1Vvv/75 PAL; - presence of video camera 1 RED LED, intermittently on; - left-right rotation angle: ± 5 13 LED's = 850 nm; 7mW/sr per LED radiated luminous intensity 0

Keyboard Display of the inhabitant's name Command of an electromagnetic lock (DC or AC) Command of an auxiliary automation (DC or AC) Case Mounting Casing protection level (IP) TOUCH type, permanently backlit Backlit name space Relay contact Maximum switched current 1 A Relay contact Maximum switched current 1 A Aluminum profile painted in electrostatic field; Secured glass screen, 8 mm thick Flush IP44 EN Operating temperature range - 30 C... + 60 C Transport and storage temperature range Dimensions Weight - 33 C... + 55 C 94 x 144 x 53 mm 1,4 kg ± 0.01 kg. Technical features of the video terminal Power supply 6... 30 V DC (stabilized) Display Keyboard Adjustments Case Mounting Casing protection level (IP) Operating temperature range 0 C... + 45 C Range of transport and storage temperatures Dimensions Weight 3.5 LCD, TFT, resolution: 30 x RGB x 40; Display Up/down/right/left visibility angle: 10/35/50/50 TOUCH type, 10 keys with backlight on touch Permanent RED signaling of the ON-OFF key if the terminal is turned off. Continuous adjustment of the audio communication volume; Image adjustments: luminosity, chrominance; ABS Glass screen, 4 mm thick Surface / Flush IP31-33 C... + 55 C 37 x 1 x 5 mm 0,6 kg ± 0.01 kg 03

POWER SUPPLY - smart (PS.VDN.ENW) CAUTION! DO NOT REMOVE INPUT: ~30V ± 10% / 50 Hz / 0,4 A THE SAFETY LID! OUTPUT: 8V ± 10% / 1, A RISK OF ELECTRICAL SHOCK!.3 Technical features of the power supply unit Supply tension 30V±10%/50Hz Output voltage/ power capability Case Mounting Casing protection level (IP) Operating temperature range Range of transport and storage temperatures Dimensions Weight 8V± 10% / 1. A Fireproof ABS -On DIN rail: TH 35 x 15 or 35 x 7,5 in compliance with DIN4677-3, EN500, IEC60715 -Surface: with A3,5 x 3 plastic screws and ø 6 mm pins IP31 0 C... + 45 C - 33 C... + 55 C 130 x 141 x 73 mm 0,4 kg ± 0.01 kg 3 BLOCK DIAGRAM OF THE SYSTEM All additional products are sold separately. OUTDOOR INDOOR (Optional) 3 / Electromagnetic lock DC / AC 3 / / 30 Va.c 3 / / Auxiliary command (Optional) Panel Power supply unit Terminal Additional terminals in parallel (optional) From the power supply unit / main terminal / additional terminal 04

4 INSTALLATION 4.1 Recommended cables EN Power supply unit Using different cables between the and the Power supply unit, the following distances can be reached: - Pair Cable (parallel) x 0.75 mm² for distances up to 30 m; - Twisted Cable x 0.75 mm² for distances up to 60 m; - Twisted Cable x 1 mm² for distances up to 80 m; For distances greater than 80 m, please request additional information from the producer. Power supply unit Video terminal Using different cables between the Power supply unit and the Terminal, the following distances can be reached: - Pair Cable (parallel) x 0.75 mm² for distances up to 50 m; - Twisted Cable x 0.75 mm² for distances up to 100 m; - Twisted Cable x 1 mm² for distances up to 10 m; For distances greater than 80 m, please request additional information from the producer. Electromagnetic lock (optional) Pair Cable (parallel) (Cu) x 0,75 mm² for distances of maximum 50 m or twisted cable (Cu) x 1 mm² for distances of maximum 10 m. Power supply unit 30 V AC network Flexible, copper multi-wire cable 3 x 0,75 mm² 4. Safety instructions for installation ATTENTION! The installation, the connection to the 30V/50 Hz network and the maintenance of the Power supply unit will only be carried out by authorized personnel! The installation of the Power supply unit is recommended to be made within an electrical panel. ATTENTION! DO NOT REMOVE THE FRONT LID! DANGER OF ELECTRIC SHOCK! Only the protection lids of the connections can be removed. ATTENTION! It is mandatory for the supply of the Power supply unit from the 30 V/50Hz network to be made through two automatic fuses of 10 A (on phase and null). The connection of the F and N terminals of the Power supply unit will be made through two isolated (Cu) wires, with a section of 0,75mm² ATTENTION! During the installation, connection of the Power supply unit at the 30 V/50Hz network and during service, the safety fuses from the electrical panel must be opened. (POWER OFF) The connection of the grounding copper wire (0,75mm²) between the grounding hub of the electrical panel and the grounding terminal of the Power supply unit is MANDATORY. 05

INPUT: ~30V ± 10% / 50 Hz / 0,4 A OUTPUT: 8V ± 10% / 1, A RISK OF ELECTRICAL SHOCK! INPUT: ~30V ± 10% / 50 Hz / 0,4 A OUTPUT: 8V ± 10% / 1, A RISK OF ELECTRICAL SHOCK! IMPORTANT! Before connecting the power supply unit's supply fuses, check the precision of the connections in the system. Check both visually, and by measurement with an ohmmeter. IMPORTANT! Install the protection lids of the power supply unit's connections before connecting the supply fuses (30V/50Hz). DO NOT TOUCH the wires exiting from the connectors and the terminals of the control supply unit. Disconnect the fuses (10 A) from the supply's phase and null of the power supply unit. ATTENTION! Do not supply components of the installation separately (outdoor panel, terminals etc.) at tensions higher than 15Vd.c. or directly from the network (30V/50Hz). DANGER OF ELECTRIC SHOCK and of the door phone system's destruction. 4.3 Installation of the p ower supply unit DIN rail mounting Wall mounting 1 POWER SUPPL Y - smart (PS.VDN.ENW ) POWER SUPPL Y - smart (PS.VDN.ENW ) DIN rail 3 Retainer A3,5 x 3 screw ( pcs.) Protection lid ( pcs.) B,9 x 13 screw (4 pcs.) 4.4 Installation of the video terminal Before starting... Surface mounting Options for cable passage 1 Screw A3,5 35(3) (4 pcs.) The terminal will be placed at 155cm height (recommended height). 0 cm Cable lenght (from the wall) Door phone cable 06

0,0 185,0 58,9 4, 78,4 30,0 4, Position of necessary mounting holes 103,0 60,0 50,0 fixing screw hole cable hole Frontal view of the back lid of the terminal Mounting depth = cm A3,5 35(3) Screw (4 pcs.) 0 cm Cable lenght (from the wall) Flush mounting Door phone cable It is necessary to make, in advance, a whole in the wall of W = 103mm, L= 0mm, D = 0mm. 1 EN 4.5 Installation of the outdoor panel The outdoor panel is installed at the entrance of the property or building, on the body closest to the access door, at a height of approx. 1.7 m (upper part) from the ground, protected from rain and sun rays. Before starting... Flush montage The outdoor panel is installed at the entrance to the building, on the body closest to the entrance door. Main connection hub Torx Screw with antitheft protection (see page 08 Antitheft protection) It is necessary to make, in advance, a whole in the wall of W = 115mm, L= 80mm, D = 50mm. Detail of camera adjustment,5 x 8 mm screw Position of necessary mounting holes fixing screw hole,5 115,0 70,0,5 33,0 Use a screwdriver to loosen the screw and then adjust the angle of the camera, then fix the screw. cable hole Frontal view of the back lid 07

Antitheft protection 1 3 Torx Screw The Torx screw must be completely screwed. Otherwise, when the system is powered, the panel emits a permanent acoustic signal. This warning function is useful if an unauthorized person tries to open the outdoor panel. The alarm turns on immediately after one starts to unscrew the Torx. Customization of name display Remove the plastic pad from the keyboard module Affix a sticker with the name, cut to size, in the space allocated to it. Insert the pad back into the keyboard module 5 CONNECTION DIAGRAM 30 V a.c./50hz JP1 L1 L Y1 BUT A1 A/Y P x Sig. 10A Electrical panel Cable 3 x 0,75 mm² to the Outdoor panel (-)L1(+)L F N Electromagnetic lock (Optional) Auxiliary command (Optional) (-)L1(+)L Power supply to the Terminal Terminal L1 L 08

5.1 Installation of the electromagnetic lock (optional) Direct current (DC) Alternative current (AC) EN JP1 L1 L Y1 BUT A1 A/Y P JP1 L1 L Y1 BUT A/Y A1 P Cable x 0.75 mm² LC 1 LC Direct current electromagnetic lock (DC) JP1 connected: The outdoor panel can supply the lock with maximum 0.5A. JP1 not connected: The lock is supplied from an external source. The outdoor panel can switch a current of maximum 1A for the supply of the lock. The lock actuating button from the interior of the building will be connected to the BUT and Y1 terminals of the outdoor panel. Cable x 0.75 mm² ~ ~ Alternative current electromagnetic lock (AC) 1 V AC 30 VAC Transformer JP1 not connected : The outdoor panel can switch a maximum current of 1A AC for the lock. 5. Connection of the auxiliary command (optional) Direct current (DC) Alternative current (AC) JP1 L1 L Y1 BUT A1 A/Y P JP1 L1 L Y1 BUT A/Y A1 P Cable x 0.75 mm² AC AC 1 Auxiliary automation - direct current (DC) Cable x 0.75 mm² ~ ~ Auxiliary automation -alternative current (AC) JP1 connected: The outdoor panel can supply the auxiliary automation with maximum 0.5A. JP1 not connected: The auxiliary automation is supplied from an external source. The outdoor panel can switch a current of maximum 1A for the supply of the auxiliary automation. 1 V AC 30 VAC Transformer JP1 not connected : The outdoor panel can switch a maximum current of 1A AC for the auxiliary automation. Note: After the correct installation of the electromagnetic lock and/or of the auxiliary automation, the Unlock Parameter must be set on one terminal. See page 1- S6. Unlock parameter settings. The parameter will be saved in the automatically, so you need to set only one terminal. ( in case there is another terminal connected in parallel). 09

6 COMMISIONING OF THE SYSTEM 6.1 Description of the Power supply unit The Power supply unit includes: Protection lid for connections GREEN signaling = presence of tension POWER SUPPLY - smart (PS.VDN.ENW) CAUTION! DO NOT REMOVE INPUT: ~30V ± 10% / 50 Hz / 0,4 A THE SAFETY LID! OUTPUT: 8V ± 10% / 1, A RISK OF ELECTRICAL SHOCK! Front lid Protection lid for connections 6. The checking of connections in the system and the connection of the power supply unit Check the precision of the connections in the system! Connect the Power supply unit to the 30 V AC network, by connecting the two automatic 10A fuses, installed on phase and null. Check the existence of the supply tensions with the values mentioned below, at the terminals of the Power supply unit (use a drive current voltmeter). Tensions measured at the terminals of the Power supply unit : 8V± 10% Tensions measured at the terminals of the and at the terminals of the Terminal: 6... 30 V DC 7 USE 7.1 User safety instructions Do not hit the glass screen with hard objects! If the front glass screen cracks, DO NOT touch the product! 7. Use of the video terminal 1 STAND-BY The keyboard is not backlit. TURN TERMINAL ON/OFF By successive touches of this key, the following states of the terminal are achieved: ON (white LED), and turned OFF (red LED). The red LED will remain permanently turned on until the key is touched again. Stand-by At the first touch of the ON/OFF key the 4 keys get lit up. 10

AUDIO VIDEO MONITORING Monitoring duration: 30 s, 40 s, 50 s, 1 min, min, 3 min, 5 min, 10 min. EN First touch of By touching this key, you may see what goes on at the entrance, in front of the outdoor panel. For audio monitoring or communication, touch also the Communication key. During call or monitoring, by touching the MENU key, image and sound adjustments can be made. ( see S7. Screen and volume adjustments). Touch the monitoring key to exit monitoring mode. Otherwise, monitoring will stop after the time set in the settings menu ( see S. Ring tone and monitoring settings). Monitoring can be also accessed by selecting the Menu. (see S1. How to enter the MAIN MENU Page). icon in the MAIN SETTINGS SETTINGS By touching the space between the keys the keys for the settings menu light up. S1. How to Enter the MAIN MENU Page 1. Touch the MENU key in stand-by mode, the Date/Time page will be showed. (The Date/Time page will turn off in 3 minutes if there is no operation.). Touch the MENU key again. The MAIN MENU page will be shown. 3. The icon is not functional. 4. To exit the MAIN MENU page select the icon and touch the MENU key to confirm. S. Ring tone and monitoring settings Using the keys, select the setup icon on the MAIN MENU page. Outdoor tone: sets the ring tone calling from the outdoor station. There are 1 types of ring tones that can be selected. Use the keys to select the previous / next ring tone, it will ring immediately. All the ring tones ring twice. To hear the selected ring tone again touch the MENU key. Monitor Time: sets the monitoring time duration. Touch the select it. The items Intercom Tone and Auto Record are not functional. keys to Outdoor Tone -- 01 Intercom Tone -- 05 Monitor Time -- 1min Advanced Set... Auto Record -- OFF Exit Password: 0 * * * S3. Date and time settings 1. Select the setup icon on the MAIN MENU page to enter SETUP PAGE, then use keys to select the Advanced set... item. Slave Addr Set -- 0 Guard Unit Set -- 0 Date/Time Set... Other Settings... A password will be asked before entering the next submenu. The Information... default password is 008. Use the to increase/ decrease the Exit value; use the keys to select last/ next digit. Touch the MENU key to confirm and enter the sub-menu page. 11

. Select the Date and time set... item. Input date and time: use the keys to increase/ decrease the value; use the keys to select last/ next digits. After finishing touch the MENU key to confirm and save the changes made. Time 1 0 : 3 Date 0 1 0 0 3 3 1 The item Other Settings... is not functional. S4. Slave address (Optional) Select Advanced set... 1. The Slave Addr Set item sets the master and slave user code. This parameter is used when a second terminal is added to the installation (in parallel). For the additional terminal this parameter should be 1.. The Guard Unit Set should be set to 0. S5. Restore to default Select Advanced set... Select the Information... item, this item will show information about the product: Hardware and software version, voltage information, manufacturing code. To set all the parameters of the terminal to initial values, select Restore to default item, then touch the MENU key. ( Note that the Restore to default operation will not change the time and date settings.) Select Exit and touch S6. Unlock parameter settings to return to the MAIN MENU page. After the installation of a electromagnetic lock or of an auxiliary automation the Unlock parameter has to be set from the terminal. Select setup setup setup Advanced set... Select the Information... item and touch the MENU key Restore to default without touching again the key.. Select Slave Addr Set -- 0 Guard Unit Set -- 0 Date/Time Set... Other Settings... Information... Exit Hardware ver 030 Software ver 0168 Voltage.4V Manufacture 00.0T Restore to default Exit Unlock Time 3 Unlock Mode 0 Unlock Menu 1 Exit 1 If the keys are disabled (unlit), touch first the ON/OFF key and then touch the Access key and hold for s. Use the keys to select an item. Use the keys to decrease/ increase the value of the item. Settings will be performed immediately. Select the Exit item and touch to exit. Note: 1. If one electromagnetic lock is installed the Unlock Menu must be set to 1.. If there is one electromagnetic lock and one auxiliary automation connected to the system, the Unlock Menu must be set to 0. In this mode, touch the Access key, two lock icons will be showed. Use the keys to select the item you want, and touch the Access or MENU key to release the corresponding lock. 3. The Restore to default operation will not change the Unlock Menu setting. 4. Unlock mode is not functional. 5. Select Unlock Time to set the time interval for the unblocking of the lock: 1..9 s. 1

S7. Screen and volume adjustments During monitoring and talking, touch the MENU key. The ADJUSTMENTS MENU will be displayed. Use the keys to select the adjustment item; use the keys to decrease/ increase the value. 1. The first item is Scene mode selection. A total of 4 screen modes can be selected in sequence: NORMAL, USER, SOFT, BRIGHT. Whenever you modify Brightness or Color, the Scene item will be set to USER mode automatically.. The Brightness and Color items adjust the quality of the image. Adjust the values to get a good quality of the image on the monitor. 3. The Ring Volume and Talk Volume items adjust the ring tone and talking volume. 4. Note that all the modifications will be done immediately after the operation. Touch the MENU key again to exit the ADJUSTMENTS MENU. user Scene Slave Addr Set -- 0 Guard Unit Set -- 0 Date/Time Set... Other Settings... Information... Exit EN CALL, COMMUNICATION and ACCESS Call duration: maximum 40 s When a call is made from the outdoor panel the four main keys light up. Call Communication ANSWER THE CALL Communication duration: maximum 90 s The LED of the key blinks and the display shows the image sent by the video camera of the outdoor panel. By touching the key, communication is initiated. The LED does not blink anymore. Do not touch the key during communication. //If there are two terminals connected in parallel, when a call is made, they both ring. The terminal that the call is answered from enters the communication, and the other one turns to Stand-by. ACCESS After the command, the lock is unblocked for the set time for the access of the visitors. Granting access does not end the communication. ACCESS without COMMUNICATION Access can be granted without communication. Touch first the monitoring key, than the access key. The lock is unblocked for the set time for the access of the visitors. Granting access does not end the monitoring. END COMMUNICATION The second touch of the key ends communication and the terminal returns to stand-by mode. Note: In Monitoring or Communication mode one can make the Screen and volume Adjustments ( See S7. Screen and Volume Adjustments) 3 AUX COMMAND AUXILIARY COMMAND No matter what the state of the terminal is: monitoring, call or communication, this key may action an automation connected to the system: auto access or garage gate, lighting system etc. 13

7.3 Use of the outdoor panel 1 STAND-BY The keyboard of the outdoor panel and the inhabitant s name is permanently backlit. The intermittent RED led signals the presence of video monitoring. CALL AND COMMUNICATION Call duration: maximum 40 s Communication duration: maximum 90 s Touch the key. The call to the inhabitant is signaled acoustically. You may end the call by touching again the key. If the inhabitant answers, communication is initiated. If access is granted, the panel emits an acoustic signal, and the lock remains unblocked for maximum 10 seconds. If the inhabitant does not answer, after 40 seconds, the panel returns to stand-by mode. 8 MAINTENANCE The outdoor panels must be kept away from corrosive substances, lime or mechanical shocks. The terminals must be kept away from water, or any other liquids, mechanical shocks, fumes, dusts etc. The components of the system can be cleaned with a piece of soft, cotton cloth. 9 WARRANTY A three year warranty is granted, from the purchase date, on the basis of the proof of purchase and if the system was used according to the technical manual. NO WARRANTY IS GRANTED for: inappropriate installation and use, deliberate damaging, theft, arson, natural disasters, unauthorized interventions to the system, the lack of protection of the system's components in case of renovation activities in the building. The ELECTRA video systems for resident buildings are produced in compliance with the EU standards and bear the CE conformity marking. 10 AUTHORIZED REPRESENTATIVE of ELECTRA S.R.L. ELECTRA Building Communications GmbH Parkring 10, Liebenberggasse 7 1010 Wien Austria Phone +43 1 516 33 3817 Fax + 43 1 516 33 3000 office@electra-automation.at Designed and Manufactured by ELECTRA Made in EU 05.014 14