Accessible Single Occupancy Toilet Rooms s Chapter 11 - Accessibility Connecticut State Building Code 1999 Section 1108.2.2 The drawings on the following pages have been reproduced from handouts from the State Building Inspector's Office. They are intended to illustrate specific code requirements and shall not be interpreted as the actual State Building Code. These illustrations shall not be scaled nor used as part of any submission to the Division of Building Inspection for the purpose of obtaining a permit.
on the width of lavatory 15" 5'-0" on type of water closet 12" 48" depending on type of water closet NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. Drawings are for illustrative purposes only. Do not scale or submit as plans for permit. 2
on the width of lavatory 15" 5'-0" on type of water closet 24" x 6'-8" 3'-0" 5'-0" depending on type of water closet NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section 603.2.3 - exception) 3
5'-0" 15" on the width of lavatory depending on of lav., plus door framing and jamb. 12" 3'-0" door 48" Door framing plus door jamb NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 4
5'-0" 15" on the width of lavatory depending on of lav., plus door framing and jamb. 24" 3'-0" door 5'-0" Door framing plus door jamb NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section 603.2.3 - exception) 5
5'-0" water closet Water closet depending on of water closet & lavatory. 5'-0" door maneuvering clearance 24" 15" 3'-0" door on the width of lavatory NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section 603.2.3 - exception) 6
5'-0" water closet depending on of water closet & lavatory. 48" door maneuvering clearance Water closet 12" 15" NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 7
5'-0" water closet depending on of water closet & lavatory. 48" lavatory Water closet 5'-0" door maneuvering clearance may vary depending on knee and toe clearance availability. 15" Lav. width varies 24" depending on width of lavatory, plus door framing and jamb. Door framing plus door jamb NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section 603.2.3 - exception) 8
5'-0" water closet depending on of water closet & lavatory. 48" lavatory Water closet 48" door maneuvering clearance may vary depending on knee and toe clearance availability. 15" Lav. width varies 12" Door framing plus door jamb depending on width of lavatory, plus door framing and jamb. NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 9
depending on of the lavatory. 4'-8" water closet depending on width of the lavatory. 15" Lav. width varies 5'-0" water closet 48" door maneuvering clearance 12" NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 10
5'-0" Lav. width varies 15" 12" 48" depending on of lavatory. NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 11