2 MODEL AND APPLICATION INFORMATION



Similar documents
Hermetic Compressor Service Handbook

Basic Nameplate Information

MAC-120HE-01 Air-Cooled Chiller

Engineering Specifications

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Split units TH with hermetic compressors

PROCEDURES FOR SELF DIAGNOSTICS

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Split System Heat Pump Product Data

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

LOBOY 16 AIR CONDITIONERS

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

R-600a - R-134a - Blends - R-290

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Split System Cooling Product Data

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Split System Cooling Product Data

Panel Mounted Air Conditioners by Dantherm, Inc.

T-Series Air Conditioner T62 Model

ice 3 FLUID TO FLUID HEAT PUMP

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Interface Protocol v1.2

AFE424 SERVICE PARTS

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Electric Motor Brake Horsepower Calculations

SMM. Installation Operation Maintenance

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

COMPRESSOR REPLACEMENT PROCEDURE

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

catalog Single Package Vertical Air Conditioners and Heat Pumps

Genesis Air Conditioner

Owners Manual Refrigerated Air Dryer

Low Profile Unit Cooler

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

PSR The compact range Description

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Air-Cooled Condensers

HP switch LP switch Discharge thermo Comp. Surface thermo

Freezers - Ultrafreezers. Platilab & Irilab Series

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Test Report issued under the responsibility of:

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. F 2016 Pentair Equipment Protection P/N

Buck - Boost Transformers

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

CONDUCTOR SHORT-CIRCUIT PROTECTION

Product Data. Split System Cooling F-EN. March 2015

Dehumidifier Users manual. For Models: DH45S DH65S

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

LG Electronics AE Company, Commercial Air Conditioning

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

, User s Manual

Explosion-Proof Electric Unit Heaters

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

THE WALL-MOUNT TM HEAT PUMPS - (60HZ)

SPECTRACOOL Air Conditioner

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Daikin Altherma hybrid heat pump. The natural combination

AIR-CONDITIONER SPLIT TYPE

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Installation Instructions

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

NSN

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Phone: Fax: Web: info@clrwtr.com

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Features and Benefits

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

RHEEM RESIDENTIAL AIR CONDITIONING

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Electrical Design Training Class Ampacity WSDOT Winter 2008 BZA

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B)

USER S MANUAL HSC-24A

Transcription:

A LOOK AT SERVICE SAFETY 2 MODEL AND APPLICATION INFORMATION I. Compressor Model Number Codes..... 10 II. Condensing Unit Model Number Codes.. 11 III. Serial Label Information.............. 12 IV. Basic Application Information for Hermetic Compressors.............. 14 9

10 Chapter 2 AE Compressor Family AE AG AH AJ AK AN AV AW AZ RG RK SA SF TP A = 1st B = 2nd C = 3rd Etc. A 4 4 40 Y Release Variant (Generation) Evap. Temperature 1. Low 2. Low 3. 4. 5. Air Cond.* 6. Medium 7. Medium 8. Air Cond. 9. Commercial 0. Commercial A. Medium/Low XA Number of First Two Application Digits In Rated Digits of Rated Refrigerant Voltage BTU Capacity BTU Capacity In this example (4) total digits, with the first two (40), or 4,000 BTU capacity. Primary Application Parameters Rating Pt. -10 F -10 F +45 F +45 F +45 F +49 F Motor Starting Torque *Application "5" compressors when applied to condensing units become application "4" in the unit's model number. Primary Refrigerants A=R12 B=R410A C=R407C E=R22 J=R502 Y=R134a Z=R404A/R507 XC Condensing Units See unit information on next page. Voltage Codes XA=115-60-1; 100-50-1 XB=230-60-1; 200-50-1 XC=220-240-50-1 XD=208-230-60-1; 200-50-1 XF=208-230-60-3; 200-240-50-3 XG=460-60-3; 380-420-50-3 XH=575-60-3; 480-520-50-3 XN=208-230-60-1; 200-220-50-1 XP=220-60-1; 200-50-1 XT=200-230-60-3; 200-220-50-3 XU=100-60-1; 100-50-1 XV=265-60-1 AB=115-60-1; 90-50-1 Note: For explanations of voltages not listed, contact Tecumseh Products Company. I. Compressor Model Number Codes Figure 2-1. Compressor model number codes.

Model and Application Information 11 AEA4440YXA XC Unassigned Letters: R The letters I, O and Q are eliminated A Standard Unit B Std. Unit w/receiver Tank C Std. Unit w/tank & BX Cable D Std. Unit w/bx Cable E,F,K Physical Design Variant (Conduit) G,H,J,L,P Physical Design Variant (Standard) M Advanced Commercial Design N Advanced Commercial Design S Customer Special T Interconnect Compressor U Water Cooled Adv. Commercial Design V Electrical Special (Conduit Design) W Water Cooled Unit X Interconnect Unit Y Air Water Cooled Unit Z Electrical Special (Standard Unit) 1. Figure 2-2. 2. 1. E=Evaporative Condensate Units. X=A holding character, reserved for future use. 2. Condensing Unit Features, see chart below. Fan Cooled Water Cooled Condensing unit model number codes. Air Water Cooled Receiver Tank BX Cable Interconect Compressor See B/M Accumulator II. Condensing Unit Model Number Codes A LOOK AT SERVICE SAFETY

III. Serial Label Information The only source for complete compressor information is on the compressor serial label. On earlier compressors, the serial plate is usually spotwelded on the upper housing of the compressor. For current compressors, the serial label is affixed in the same location. Both describe the characteristics of the compressor. The months are identified as identified in Table 2-1. Bill of Material Number Second letter indicates month (see Table 2-1), next 2 digits indicate day of the month, following 2 digits indicate year. Electrical Rating VOLTS - HERTZ Serial Number AH301FT - 077 SE1490C 281254 AH5540E V230/208Hz60 LRA103.0 V200 Hz50 PHI USA P Phase Compressor Model Number Figure 2-3. Compressor serial label. Figure 2-4. Compressor serial plate. 12 Chapter 2

A LOOK AT SERVICE SAFETY Manufacturing Code Date Month = September 0J0 Year = 2000 The letter represents the month (see Table 2-1). The numbers represent the year. COMPRESSORS THERMALLY PROTECTED VOLTAGE EVAP. RANGE (ºF) NO R.L.A. E.A. L.R.A. E.A. PH. 60 HZ 50 HZ 1 8.8 FANS: NO. F.L.A. E.A. 1 SER EM MOD (1P) 58.8 HP. 1 PROTECTED 115-10F TO +45F PH. MIN. CIRCUIT AMPACITY DESIGN PRESSURE P.S.I. HI SIDE LO SIDE 1.4 35W THERMALLY 1 12.4 350 150 MAX. MAX. CKT. BKR. 0J00066332 FUSE (HACR. TYPE PER NEC.) REFRIG. 2C234-9 20 R-22 444 52594-1 AKA9446EXAXC P MADE IN USA OZ. CHARGE Figure 2-5. Condensing unit serial label. Table 2-1: Serial Label Month Identifiers January - A March - C May - E July - G September - J November - L February - B April - D June - F August - H October - K December - M Model and Application Information 13

IV. Basic Application Information for Hermetic Compressors Tecumseh hermetic compressors are engineered to do specific air conditioning and refrigeration tasks. Hermetic compressors are designed for a particular evaporator temperature range and a specific refrigerant. A. Evaporator Temperatures The key specification is the evaporator temperature of the system. Compressors which are operating outside their design evaporator temperature range can be expected to have poor pumping efficiency and experience motor problems. Tecumseh hermetic compressors are designed for one of the following evaporator temperature ranges shown in Table 2-2. B. Refrigerant Use only the serial label refrigerant when charging the system. Using a different refrigerant can lead to excess system pressure, damage to the compressor and an explosion. For example, using R-502 in a compressor designed for R-12 can lead to higher operating pressures that can overload the bearings and overwork the motor. Use of a refrigerant other than the serial label refrigerant will void the compressor warranty. Table 2-2: Evaporator Temperature Ranges Application Air Conditioning Improved Performance Air Conditioning Heat Pump (Approved Models) Evaporator Temperature Medium Evaporator Temperature Low Evaporator Temperature ( Torque Motor) Low Evaporator Temperature ( Torque Motor) Commercial Approved Evaporator Temperatures +32ºF to +55ºF +32ºF to +57ºF -15ºF to +55ºF +20ºF to +55ºF -10ºF to +30ºF -30ºF to +10ºF -40ºF to +10ºF 0ºF to +50ºF 14 Chapter 2