1 INDEX ACCESSORIES barb nylon fittings condensor pads condensor wall bracket electrical PIPE INSULATION REFRIGERATION SERVICE TUBING COPPER COILS INDOOR RCFM CONDENSING UNITS 13AJM- SERIES 1-1/2 TO 5 TONS RANL- JAZ SERIES 1-1/2 TO 5 TONS rapm- JAZ SERIES 1-1/2 TO 5 TONS TECHNICAL DATA (IN CERTAIN 13 SEER MATCHED MODELS SYSTEMS) (IN CERTAIN MATCHED SYSTEMS) Available in Northern Alberta, Saskatchewan and Manitoba. ECCO is proud to be a member of: HRAI Heating, Refrigeration and Air Conditioning Institute of Canada HARDI Heating, Air-conditioning & Refrigeration Distributors International SMACNA Sheet Metal and Air Conditioning Contractors National Association SPIDA Spiral Duct Manufacturers Association CIPH Canadian Institute of Plumbing & Heating ECCO Supply 3-1

2 RANL- *AZ 13 SEER Models Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.6 kw] Seven Models Model Number Identification R A N L 018 RHEEM REMOTE CONDENSING UNIT N = 13 SEER ear th fr iendly r efr iger ant DESIGN SERIES L = R-410A Pricing Effective: June 2011 The Rheem Classic Series High Efficiency RANL- Con- RHEEM RESIDENTIAL densing Units were designed AIR CONDITIONING with performance in mind. COOLING CAPACITY 018 = 18,000 BTU/HR [5.28 kw] 024 = 24,000 BTU/HR [7.03 kw] 031 = 30,000 BTU/HR [8.79 kw] 037 = 36,000 BTU/HR [10.55 kw] 043 = 42,000 BTU/HR [12.31 kw] 049 = 48,000 BTU/HR [14.07 kw] 060 = 60,000 BTU/HR [17.58 kw] These units offer comfort, energy conservation and dependability for single, multi-family and light commercial Cooling Capacities RANL- JAZ SERIES CONDENSING UNITS 1-1/2 applications. 18,300 to 62,000 BTU/HR TO 5 TONS These units also contain the most advanced alternate [ seer kw] to [18.17 R410A kw] 1 phase 10 YEAR WARRANTY refrigerant which contains no chlorofluorocarbons (CFCs), The Rheem Classic Series High Efficiency RANL- Condensing Units or were hydrochlorofluorocarbons designed with (HCFCs), or other compounds and dependability that may leak for from air-conditioning systems and performance in mind. These units offer comfort, energy conservation single, multi-family and light commercial applications. potentially harm the protective ozone layer of the Earth s atmosphere. These units also contain the most advanced alternate refrigerant which contains no The Rheem Classic Series RANL- Condensing Units are chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), the or other result compounds of an ongoing development program for improved that may leak from air-conditioning systems and potentially harm the efficiencies. protective These ozone units are flexible enough to achieve up layer of the Earth s atmosphere. to SEER in specific match-ups, continuing a tradition The Rheem Classic Series RANL- Condensing Units are the result of of an high ongoing efficiency. development program for improved efficiencies. These units are flexible enough to achieve Attractive, up to louvered SEER in specific wrap-around matchups, continuing a tradition of high efficiency. from yard hazards and weather extremes. Top grille is jacket protects the coil steel reinforced for extra strength. Cabinet is powder Attractive, louvered wrap-around jacket protects the painted All controls for all-weather are accessible protection. by removing one service coil from yard hazards and weather extremes. Top grille Air panel. is discharged Removable upward top grille away provides from bushes access to and the shrubs. is steel reinforced for extra strength. Cabinet is powder The condenser discharge fan pattern motor and of the condenser top grille coil. provides minimum painted for all-weather protection. air Single restriction. speed 8-pole fan motor designed for low speed, Air is discharged upward away from bushes and Combination quiet, energy-saving Grille/Motor operation. Mount All secures models meet the motor or to shrubs. The discharge pattern of the top grille provides the exceed underside a 1000-hour of the salt discharge spray test grille. per The ASTM grille B117 protects minimum air restriction. the motor Practice windings for and Operating bearings Salt from Spray rain Testing and snow. Combination Grille/Motor Mount secures the motor to All Apparatus. controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation All models meet or exceed a 1000-hour salt spray test per ASTM J B117 A Practice for Operating Z Salt Spray Testing Apparatus. ELECTRICAL VARIATIONS COOLING CONNECTION DESIGNATION A-SERIES = FULL-FEATURED FITTING J = 208/230V-1-60 Z = SWEAT W/SCROLL C = 208/230V-3-60 (RANL MODELS ONLY) D = 460V-3-60 (RANL MODELS ONLY) Y = 575V-3-60 (RANL 4 & 5 TON 13 SEER MODELSONLY) (IN CERTAIN MATCHED SYSTEMS) Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit COOLING CAPACITY (TONS) WEIGHT/ LBS ITEM # Model ELECTRICAL Price RANL-018JAZ /230/1 140 P.O.A RANL-024JAZ /230/1 150 P.O.A RANL-031JAZ /230/1 153 P.O.A RANL-036JAZ /230/1 203 P.O.A RANL-048JAZ /230/1 214 P.O.A RANL-060JAZ /230/1 250 P.O.A. NOTE: 3 Phase units are available P.O.A. For Technical Data see end of section

3 13AjM- SERIES CONDENSING UNITS 1-1/2 TO 5 TONS 13 seer R410A 1 PHASE 10 YEAR WARRANTY Features Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper tubing and enhanced aluminum fins Grille/Motor mount for quiet fan operation Bi-Directional Filter Drier (shipped not installed) Applications Outdoor condensing unit designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial applications. Model Number Identification Model Number Identification 13 A J M 18 A SEER A = AIR CONDITIONER VOLTAGE J = SINGLE PHASE DESIGN SERIES M = 2ND DESIGN R-410A NOMINAL COOLING CAPACITY 18 = 18,000 BTU/HR [5.28 kw] 24 = 24,000 BTU/HR [7.03 kw] 30 = 30,000 BTU/HR [8.79 kw] 36 = 36,000 BTU/HR [10.55 kw] 42 = 42,000 BTU/HR [12.31 kw] 48 = 48,000 BTU/HR [14.07 kw] 60 = 60,000 BTU/HR [17.58 kw] CABINET A = FULL METAL JACKET RHEEM VALUE SERIES COOLING CAPACITY (TONS) WEIGHT/ LBS ITEM # Model ELECTRICAL Price AJM18A /230/1 135 P.O.A AJM24A /230/1 135 P.O.A AJM30A /230/1 154 P.O.A AJM36A /230/1 198 P.O.A AJM42A /230/1 195 P.O.A AJM48A /230/1 233 P.O.A AJM60A /230/1 234 P.O.A. Note: For Technical Data see end of section

4 rapm- JAZ SERIES CONDENSING UNITS 1-1/2 TO 5 TONS 14 seer R410A 1 PHASE 10 YEAR WARRANTY The Rheem Classic Series High Efficiency RAPM- Condensing Units were designed with performance in mind. These units offer comfort, energy conservation and dependability for single, multi-family and light commercial applications. These units also contain the most advanced alternate refrigerant which contains no chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), or other compounds that may leak from air-conditioning systems and potentially harm the protective ozone layer of the Earth s atmosphere. The Rheem Classic Series RAPM- Condensing Units are the result of an ongoing development program for improved efficiencies. These units are flexible enough to achieve up to SEER in specific match-ups, continuing a tradition of high efficiency. Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all-weather protection. Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction. Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. All models meet or exceed a 1000-hour salt spray test per ASTM B117 Practice for Operating Salt Spray Testing Apparatus. Model Number Identification Model Number Identification R A P M 018 J A Z RHEEM REMOTE CONDENSING UNIT P = 14 SEER DESIGN SERIES M = R-410A (2ND DESIGN SERIES) COOLING CAPACITY 018 = 18,000 BTU/HR [5.28 kw] 024 = 24,000 BTU/HR [7.03 kw] 030 = 30,000 BTU/HR [8.79 kw] 036 = 36,000 BTU/HR [10.55 kw] 042 = 42,000 BTU/HR [12.31 kw] 048 = 48,000 BTU/HR [14.07 kw] 060 = 60,000 BTU/HR [17.58 kw] IN CERTAIN MATCHED SYSTEMS ELECTRICAL VARIATIONS DESIGNATION A-SERIES = FULL-FEATURED J = 208/230V-1-60 COOLING CONNECTION FITTING Z = SWEAT W/SCROLL Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit COOLING CAPACITY (TONS) WEIGHT/ LBS ITEM # Model ELECTRICAL Price RAPM-018JAZ /230/1 152 P.O.A RAPM-024JAZ /230/1 205 P.O.A RAPM-030JAZ /230/1 213 P.O.A RAPM-036JAZ /230/1 223 P.O.A RAPM-048JAZ /230/1 290 P.O.A RAPM-060JAZ /230/1 299 P.O.A. Note: Contact your local ECCO Sales Branch for coil pricing. For Technical Data see end of section

5 RCFM- INDOOR COILS CASED/UNCASED COILS FOR GAS AND OIL FURNACES R410A AIRFLOW CAPACITIES 600-1,900 CFM [ L/s] Rheem Indoor Coils are designed for use with Rheem outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 24,000 BTU/HR [7.03 kw] to 60,000 BTU/HR [17.58 kw]. Constructed of aluminum fins bonded to internally grooved copper tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have sweat refrigerant connections. Ideally suited for new installations or add on air conditioning. Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection. Coils are A.R.I. certified for system application with variety of Rheem outdoor units. Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. MODEL NUMBER DATA MODEL NUMBER IDENTIFICATION R C F M HM A C Note: For Technical Data see end of section. Compatible with Germicidal Light System (UV resistant). Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. Unique drain pan design maximizes application flexibility and condensate removal. Gas/Oil Furnace Coil C = Cased U = Uncased Available Models of RCFM Coils Design Variation A = 1st Design C = 2nd Design RCFM-HM2417AC RCFM-HM2421AC RCFM-HU2417AU RCFM-HU2421AU Coil Size RCFM-HM3617AC RCFM-HU3617AU 17 = 17.5" [431.8 mm] 21 = 21" [533.4 mm] RCFM-HM3617CC RCFM-HU3617CU 24 = 24.5" [609.6 mm] Nominal Capacity 24 = 24,000 BTU/HR [7.03 kw] 36 = 36,000 BTU/HR [10.55 kw] 48 = 48,000 BTU/HR [14.06 kw] 60 = 60,000 BTU/HR [17.58 kw] Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position Uncased Coil Airflow: RCFM-HM3621AC RCFM-HM3621CC RCFM-HM4821AC RCFM-HM4824AC RCFM-HM6024AC RCFM-HU3621AU RCFM-HU3621CU RCFM-HU4821AU RCFM-HU4824AU RCFM-HU6024AU HU = A/C or Heat Pump, Upflow/Downflow Refrigerant M = R-410A (16 SEER) F = Product Generation Classification C = Coil Rheem 3-5

6 ACCESSORIES ITEM # Model DESCRIPTION Price BC-CB151TUL Condensate Pump with Switch and Tubing $ BC-CB151UL Condensate Pump BC-CB151LSUL Condensate Pump CP-22 Condensate Pump CP-22T Condensate Pump w/tubing VCMA-15ULST Condensate Pump VCMA-15UL Condensate Pump /8" 1/2" Clear Plastic Tubing.64/ft /8" 1/2" 100' Clear Plastic Tubing 44.00/roll /4" 1" 100' Clear Plastic Tubing /roll /2" 5/8" 100' Clear Plastic Tubing 56.00/roll /2" 5/8" Clear Plastic Tubing.85/ft /8" 3/4" Clear Plastic Tubing.75/ft /8" 3/4" 100' Clear Plastic Tubing 70.00/roll condensor pads ITEM # Model SIZE (") DESCRIPTION Price Cement Patio Block $ UltraLite Concrete Pad UltraLite Concrete Pad UltraLite Concrete Pad UltraLite Concrete Pad UltraLite Concrete Pad E-Lite Plastic Pad E-Lite Plastic Pad barb nylon fittings ITEM # Model DESCRIPTION Price /4" MIP 5/8" Barb 90 Elbow $ /4" MPT 3/4" Barb 90 Elbow /4" FIP 5/8" Barb 90 Elbow /4" MPT 3/4" Barb Adapter TEA /4" MPT 1/2" Barb Adapter

7 ACCESSORIES (cont d) electrical ITEM # Model DESCRIPTION Price DDS-60U Air Conditioner Disconnect $ B6-12-6NM A/C Electrical Whip PIPE INSULATION ITEM # DESCRIPTION Price /8" 3/8" 6 ft. Generic $ /8" 3/8" 6 ft. Generic /4" 3/8" 6 ft. Generic /8" 3/8" 6 ft. Generic /4" 3/8" 6 ft. Armaflex /8" 3/8" 6 ft. Armaflex /8" 3/8" 6 ft. Armaflex Pipe Insulation REFRIGERATION SERVICE TUBING COPPER ITEM # DESCRIPTION WALL THICKNESS Price/ROll C /8" 50 ft..030 P.O.A /4" 50 ft..030 $ /16" 50 ft /8" 50 ft /2" 50 ft /8" 50 ft /4" 50 ft /8" 50 ft /8" 50 ft Copper Tubing condensor wall bracket ITEM # SIZE WALL THICKNESS Price/PAIR Condensor Wall Bracket (MB & ON only) $ Condensor Bracket 1-1/2 3 Ton Condensor Bracket 3 5 Ton Condensor Wall Bracket Condensor Wall Bracket with Cross Brace Not exactly as illustrated

8 TECHNICAL DATA RANL- *AZ RANL- *AZ 13 SEER Models Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.6 kw] FORM NO. A REV. 8 Supersedes Form No. A Rev. 7 CONDENSING UNITS ear th fr iendly r efr iger ant Seven Models Cooling Capacities 18,300 to 62,000 BTU/HR [5.36 kw] to [18.17 kw] FORM NO. A REV. 8 Supersedes Form No. A Rev. 7 RANL- *AZ 13 SEER Models Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.6 kw] Seven Models Cooling Capacities 18,300 to 62,000 BTU/HR [5.36 kw] to [18.17 kw] ear th fr iendly r efr iger ant All controls and compressor are accessible for servicing by removal of the service panel. Drawn Painted Base Pan. Model Number Identification R A N L 018 Engineering Features RANL- Series Condensing Units 1. This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. The Rheem Classic 3. All refrigerant Series High Efficiency RANL- Condensing Units were designed with performance in mind. connections are on the exterior of the unit, These located units close offer to comfort, the ground energy for neat conservation appearing and installations. dependability 4. Cabinet for is constructed single, multi-family of powder and light painted commercial galvanized applications. steel. The full wraparound louvered grille protects the coil These from units damage. also contain the most advanced alternate refrigerant which contains no chlorofluorocarbons (CFCs), 5. Copper tubealuminum fin coils are used on all models. or hydrochlorofluorocarbons (HCFCs), or other compounds 6. The that control may box leak is from located air-conditioning in the top systems corner of and the cabinet potentially providing harm for the easy protective access ozone through layer a of service the Earth s panel. atmosphere. 7. Service valves are standard on all models. The Rheem Classic Series RANL- Condensing Units are the 8. result Power of an and ongoing control development wiring are program kept separate. for improved efficiencies. 9. Every unit These is units factory are charged flexible enough and tested. to achieve up to SEER in specific match-ups, continuing a tradition of 10. high Separate efficiency. compressor compartment for easy service access. 11. Attractive, Drawn, louvered painted wrap-around base pan for jacket extra protects corrosion the resistance coil and from sound yard reduction. hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder 12. Automatic reset high and low pressure controls are standard painted for all-weather protection. on all models. Air is discharged upward away from bushes and shrubs. 13. The Adischarge liquid line pattern filter drier of the is top standard grille provides on all models minimum(shipped air restriction. not installed). Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. All models meet or exceed a 1000-hour salt spray test per ASTM B117 Practice for Operating (cont d Salt on next page) Spray Testing Apparatus. J A Z 13.0 RHEEM REMOTE N = 13 SEER DESIGN COOLING ELECTRICAL VARIATIONS COOLING CONNECTION CONDENSING SERIES CAPACITY DESIGNATION FITTING UNIT A-SERIES = FULL-FEATURED L = R-410A 018 = 18,000 BTU/HR [5.28 kw] J = 208/230V-1-60 Z = SWEAT W/SCROLL 024 = 24,000 BTU/HR [7.03 kw] C = 208/230V SEER MODELS 031 = 30,000 BTU/HR [8.79 (IN CERTAIN kw] MATCHED (RANL SYSTEMS) MODELS 037 = 36,000 BTU/HR [10.55 kw] ONLY) Proper sizing and installation of equipment is critical to achieve optimal performance. 043 = 42,000 BTU/HR [12.31 kw] D = 460V-3-60 Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details 049 = 48,000 BTU/HR [14.07 kw] (RANL MODELS or visit = 60,000 BTU/HR [17.58 kw] ONLY) Y = 575V-3-60 E.&O.E. All Prices F.O.B. Our Warehouse Subject to Change Without Notice (RANL All 4 Taxes & 5 TON Extra May not be Available at All Branches MODELS ONLY) 3-8

9 TECHNICAL DATA (cont d) RANL- *AZ (cont d) Electrical and Physical Data: RANL- ELECTRICAL PHYSICAL Model No. RANL- Phase Frequency (Hz) Voltage (Volts) Compressor Rated Load (RLA) Locked Rotor (LRA) Fan Motor Full Load (FLA) Min. Circuit Ampacity Fuse or HACR Circuit Breaker Min. Max. Face Area Sq. Ft. [m 2 ] Outdoor Coil No. Rows CFM [L/s] Refrig. Per Circuit Oz. [g] Net Lbs. [kg] Weight Shipping Lbs. [kg] 018JAZ /230 9/ /12 15/15 20/ [0.84] [838] 70 [1984] 130 [59.0] 140 [63.5] 024JAZ / / /17 20/20 25/25 1 [1.02] [906] 72 [2041] 140 [63.5] 150 [68.0] 031JAZ / / /19 25/25 30/ [1.03] [906] 83 [2353] 143 [64.9] 153 [69.4] 037CAZ / / /18 25/25 30/ [1.50] [1510] 106 [3005] 193 [87.5] 203 [92.1] 037DAZ [1.50] [1510] 106 [3005] 193 [87.5] 203 [92.1] 037JAZ / / /24 30/30 40/ [1.50] [1510] 106 [3005] 193 [87.5] 203 [92.1] 043CAZ / / /19 25/25 30/ [1.50] [1510] 115 [3260] 202 [91.6] 212 [96.2] 043DAZ [1.50] [1510] 115 [3260] 202 [91.6] 212 [96.2] 043JAZ / / /27 35/35 45/ [1.50] [1510] 115 [3260] 202 [91.6] 212 [96.2] 049CAZ / / /19 25/25 30/ [1.87] [1652] 132 [3742] 214 [97.1] 224 [101.6] 049DAZ [2.15] [1652] 132 [3742] 214 [97.1] 224 [101.6] 049JAZ / / /29 35/35 50/ [1.87] [1652] 132 [3742] 214 [97.1] 224 [101.6] 049YAZ [1.87] [1652] 132 [3742] 214 [97.1] 224 [101.6] 060CAZ / / /21 25/25 35/ [2.14] [1652] 180 [5103] 250 [113.4] 260 [117.9] 060DAZ [2.14] [1652] 180 [5103] 250 [113.4] 260 [117.9] 060JAZ / / /35 45/45 60/ [2.14] [1652] 180 [5103] 250 [113.4] 260 [117.9] 060YAZ [2.14] [1652] 180 [5103] 250 [113.4] 260 [117.9] (cont d on next page) 3-9

10 TECHNICAL DATA (cont d) RANL- *AZ (cont d) Unit Dimensions AIR DISCHARGE ALLOW 60 [1524 mm] CLEARANCE W L SERVICE FITTINGS LOW VOLTAGE CONNECTION 7/80 [22 mm] H AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES A ACCESS PANEL ALLOW 24 [610 mm] ACCESS CLEARANCE A HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) VAPOR LINE CONNECTION 2 7 /80 [73 mm] DIA. ACCESSORY KNOCKOUTS HIGH VOLTAGE CONNECTION 1 11 /320 [34 mm] LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 240 [610 mm] CLEARANCE ONE SIDE Model Number RANL- Height H (Inches) [mm] Length L (Inches) [mm] Width W (Inches) [mm] [483] 35 1 /2 [902] 23 3 /4 [603] 024/ [483] 40 1 /2 [1029] 27 5 /8 [702] 037/ [584] 44 3 /8 [1127] 31 1 /2 [800] [737] 44 3 /8 [1127] 31 1 /2 [800] [838] 44 3 /8 [1127] 31 1 /2 [800] (cont d on next page) BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Condenser Coil leaks caused by factory defects...five (5) Years Compressor JAZ...Ten (10) Years CAZ, DAZ, YAZ...Five (5) Years *All Other Parts JAZ...Five (5) Years CAZ, DAZ, YAZ...One (1) Year *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1,

11 TECHNICAL DATA (cont d) RANL- *AZ (cont d) Condensing Unit Refrigerant Line Size Information System Capacity 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton Line Size Connection (Inch I.D.) Line Size (Inch O.D.) [mm] 25 [7.62] Liquid Line Size Outdoor Unit Above Indoor Coil (Cooling Only Does not apply to Heat Pumps) Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] Liquid Line Sizing (R-410A) 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] Liquid Line Size Outdoor Unit Below Indoor Coil Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] Minimum Vertical SeparationFeet [m] Maximum Vertical SeparationFeet [m] 1/4* [6.35] [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] 150 [45.72] 5/16 [7] [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14] 3/8* [9.53] [7.62] 50 [15.24] 75 [22.86] 72 [21] 70 [21.34] 68 [20.73] 1/4* [6.35] 0 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] 5/16 [7] [7.62] 36 [10] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 3/8* [9.53] [7.62] 50 [15.24] 72 [21] 70 [21.34] 68 [20.73] 65 [19.81] 1/4* [6.35] 0 14 [4.27] 56 [17.07] 98 [29.87] 25 [7.62] 5/16 [7] [7.62] 49 [14] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 5/16* [7] [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 5/16* [7] [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 3/8* [9.53] [7.62] 50 [15.24] 43 [13.11] 36 [10] 30 [9.14] 24 [7.32] 3/8* [9.53] [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57] 1/2 [12.57] [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85] 3/8* [9.53] [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10] 5 Ton 1/2 [12.57] [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16] NOTES: * line size = Application not recommended. Unit Size Suction Line Connection Size Suction Line Run Feet [m] 1 1 /2 Ton 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* Suction Line Length/Size versus Capacity Multiplier (R-410A) 2 Ton 2 1 /2 Ton 3 Ton 3/4" [19.05 mm] I.D. 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt. 3 1 /2 Ton 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* 4 Ton 7/8" [22.23 mm] I.D. 5 Ton 7/8" [22.23 mm] O.D. Opt. 1 1 /8" [28.58 mm] O.D. Std.* 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] NOTES: * line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Rheem Heating, Cooling and Water Heating P.O. Box 17010, Fort Smith, AR In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A DC FORM NO. A REV. 8 Supersedes Form No. A Rev

12 TECHNICAL DATA 13AJM- SERIES Electrical and Physical Data FORM NO. A REV. 1 Supersedes Form No. A Model Number 13AJM Rev. 7/29/09 Phase Frequency [HZ] Voltage [Volts] Rated Load (RLA) Compressor ELECTRICAL Locked Rotor (LRA) Fan Motor Full Load (FLA) Minimum Circuit Ampacity Fuse or HACR Circuit Breaker Minimum Maximum Face Area Sq. Ft. [m 2 ] / / /17 20/20 25/ [0] Refrigerant Per No. Circuit Rows CFM [L/s] Net Oz. [g] Outdoor Coil PHYSICAL Lbs. [kg] Weight Shipping Lbs. [kg] /230 9/ /12 15/15 20/ [0.78] [790] 75.2 [2132] 120 [54.4] 128 [58.1] / / /18 25/25 30/ [0.78] [786] 73.8 [2092] 121 [54.9] 129 [58.5] [979] 86.8 [2440] 139 [63.1] 147 [66.7] / / /22 30/30 35/ [1.15] [1324] 96 [2722] 159 [72.1] 167 [75.8] / / /24 30/30 40/ [1.52] [1555] [3583] 188 [85.3] 192 [87.1] / / /29 35/35 45/ [2.03] [1555] 144 [4082] 207 [93.9] 218 [98.9] / / /35 45/45 60/ [2.03] [1685] 176 [4990] 223 [101.2] 234 [106.1] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. Unit Dimensions Model No. 13AJL Width W Inches Unit Dimensions Length L Inches 48, /8 [803] 31 5 /8 [803] Height H Inches 18, /8 [600] 23 5 /8 [600] 24 1 /4 [616] /8 [702] 27 5 /8 [702] 24 1 /4 [616] 36, /8 [803] 31 5 /8 [803] /16 [710] /16 [913] w LOW VOLTAge 7/8" [22 mm] HOLE DIAMETER detail a HIGH VOLTAge 1-11/32" [34 mm] HOLE DIAMETER L SERVICE FITTING H 2" [50.8 mm] SERVICE FITTING SEE DETAIL A BASERAIL LIQUID line connection vapor line connection (cont d on next page)

13 TECHNICAL DATA (cont d) 13AJM- SERIES (cont d) Condensing Unit Refrigerant Line Size Information System Capacity 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Liquid Line Connection Size (Inch I.D.) [9.53] [9.53] [9.53] [9.53] [9.53] [9.53] [9.53] Line Size (Inch O.D.) [mm] NOTES: * line size = Application not recommended. 25 [7.62] Liquid Line Sizing (R-410A) Liquid Line Size Outdoor Unit Above Indoor Coil (Cooling OnlyDoes not apply to Heat Pumps) Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] Liquid Line Size Outdoor Unit Below Indoor Coil Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] Minimum Vertical SeparationFeet [m] Maximum Vertical SeparationFeet [m] 1/4 [6.35] [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] 5/16* [7] [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14] 3/8* [9.53] [7.62] 50 [15.24] 75 [22.86] 72 [21] 70 [21.34] 68 [20.73] 1/4 [6.35] 0 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] 5/16* [7] [7.62] 36 [10] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 3/8* [9.53] [7.62] 50 [15.24] 72 [21] 70 [21.34] 68 [20.73] 65 [19.81] 1/4 [6.35] 0 14 [4.27] 56 [17.07] 98 [29.87] 25 [7.62] 5/16* [7] [7.62] 49 [14] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 5/16 [7] [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 5/16 [7] [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 3/8* [9.53] [7.62] 50 [15.24] 43 [13.11] 36 [10] 30 [9.14] 24 [7.32] 3/8* [9.53] [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57] 1/2 [12.57] [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85] 3/8* [9.53] [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10] 1/2 [12.57] [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16] Unit Size Suction Line Connection Size 1 1 /2 Ton Suction Line Length/Size versus Capacity Multiplier (R-410A) 2 Ton 2 1 /2 Ton 3 Ton 3/4" [19.05] I.D. 3 1 /2 Ton 4 Ton 7/8" [22.23] I.D. 5 Ton Suction Line RunFeet [m] 5/8" [15.88 mm] O.D. 3/4" [19.05 mm] O.D. * 5/8" [15.88 mm] O.D. 3/4" [19.05 mm] O.D. * 7/8" [22.23 mm] O.D. 3/4" [19.05 mm] O.D. 7/8" [22.23 mm] O.D. * 7/8" [22.23 mm] O.D. 1 1 /8" [28.58 mm] O.D. * 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] NOTES: * line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or visit Condenser Coil leaks caused by factory defects...five (5) Years Conditional Compressor*...Ten (10) Years Any Other Part...Five (5) Years *See Product Warranty Card for Details. E.&O.E. All Prices F.O.B. Our Warehouse Subject to Change Without Notice Rheem All Heating, Taxes Extra Cooling May and not Water be Available Heatingat All Branches

14 technical data (cont d) RAPM- JAZ JAZ 14.5 SEER Models Efficiencies up to SEER Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.6 kw] Seven Models Cooling Capacities 18,600 to 62,500 BTU/HR [5.45 kw] to [18.32 kw] FORM NO. A REV. 1 Supersedes Form No. A All controls and compressor are accessible for servicing by removal of the service panel. Engineering Features RAPM- Series Condensing Units 1. This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. 3. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. 4. Cabinet is constructed of powder painted galvanized steel. The full wraparound louvered grille protects the coil from damage. 5. Copper tubealuminum fin coils are used on all models. 6. The control box is located in the top corner of the cabinet providing for easy access through a service panel. 7. Service valves are standard on all models. 8. Power and control wiring are kept separate. 9. Every unit is factory charged and tested. 10. Separate compressor compartment for easy service access. 11. Drawn, painted base pan for extra corrosion resistance and sound reduction. 12. Automatic reset high and low pressure controls are standard on all models. 13. A liquid line filter drier is standard on all models (shipped not installed). Drawn Painted Base Pan. (cont d on next page) IN CERTAIN MATCHED SYSTEMS Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit

15 technical data (cont d) RAPM- JAZ (cont d) Electrical and Physical Data: RAPM- Model Number RAPM- Rev. 11/18/09 Phase Frequency (Hz) Voltage (Volts) Rated Load (RLA) Compressor ELECTRICAL Locked Rotor (LRA) Fan Motor Full Load (FLA) Minimum Circuit Ampacity Fuse or HACR Circuit Breaker Minimum Maximum Face Area Sq. Ft. [m 2 ] Outdoor Coil PHYSICAL Refrig. Per No. Circuit Rows CFM [L/s] Net Oz. [g] Lbs. [kg] Weight Shipping Lbs. [kg] 018JAZ /230 9/ /14 20/20 20/20 1 [1.02] [1085] 82 [2325] [62.8] [72.8] 024JAZ / / /18 25/25 30/ [1.86] [1557] 128 [3629] [87.3] [97.3] 030JAZ / / /18 25/25 30/ [1.86] [1557] 129 [3657] 193 [87.5] 214 [97.1] 036JAZ /230 16/ /22 30/30 35/ [2.14] [1557] 146 [4139] [89.6] 227 [103] 042JAZ / / /26 30/30 40/ [2.14] [1557] 152 [4309] 223 [101.2] 256 [116.1] 048JAZ / / /31 40/40 50/ [2.14] [1557] 203 [5755] 264 [119.8] 298 [135.2] 060JAZ / / /36 45/45 60/ [2.14] [1557] 262 [7428] [122.2] [139] Unit Dimensions AIR DISCHARGE ALLOW 60 [1524 mm] CLEARANCE LOW VOLTAGE CONNECTION 7/80 [22 mm] W L SERVICE FITTINGS HIGH VOLTAGE CONNECTION 1 11 /320 [34 mm] H AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES A ACCESS PANEL ALLOW 24 [610 mm] ACCESS CLEARANCE A VAPOR LINE CONNECTION HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) 2 7 /80 [73 mm] DIA. ACCESSORY KNOCKOUTS LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 240 [610 mm] CLEARANCE ONE SIDE Model Number RAPM- Height H (Inches) [mm] Length L (Inches) [mm] Width W (Inches) [mm] [483] 40 1 /2 [1029] 27 5 /8 [702] 024/ [737] 44 3 /8 [1127] 31 1 /2 [800] 036/042/ 048/ [838] 44 3 /8 [1127] 31 1 /2 [800] (cont d on next page) BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. 20 Rheem Heating, Cooling and Water Heating Condenser Coil leaks caused by factory defects...five (5) Years Compressor JAZ...Ten (10) Years Conditional Parts* (Registration Required)...Ten (10) Years *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1,

16 technical data (cont d) RAPM- JAZ (cont d) Condensing Unit Refrigerant Line Size Information System Capacity 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton Line Size Connection (Inch I.D.) Line Size (Inch O.D.) [mm] 25 [7.62] Liquid Line Size Outdoor Unit Above Indoor Coil (Cooling Only Does not apply to Heat Pumps) Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] Liquid Line Sizing (R-410A) 100 [30.48] 125 [38.10] 150 [45.72] 25 [7.62] Liquid Line Size Outdoor Unit Below Indoor Coil Total Equivalent LengthFeet [m] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] Minimum Vertical SeparationFeet [m] Maximum Vertical SeparationFeet [m] 1/4* [6.35] [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] 150 [45.72] 5/16 [7] [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14] 3/8* [9.53] [7.62] 50 [15.24] 75 [22.86] 72 [21] 70 [21.34] 68 [20.73] 1/4* [6.35] 0 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] 5/16 [7] [7.62] 36 [10] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 3/8* [9.53] [7.62] 50 [15.24] 72 [21] 70 [21.34] 68 [20.73] 65 [19.81] 1/4* [6.35] 0 14 [4.27] 56 [17.07] 98 [29.87] 25 [7.62] 5/16 [7] [7.62] 49 [14] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 5/16* [7] [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] 3/8* [9.53] [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 5/16* [7] [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 3/8* [9.53] [7.62] 50 [15.24] 43 [13.11] 36 [10] 30 [9.14] 24 [7.32] 3/8* [9.53] [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57] 1/2 [12.57] [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85] 3/8* [9.53] [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10] 5 Ton 1/2 [12.57] [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16] NOTES: * line size = Application not recommended. Suction Line Length/Size versus Capacity Multiplier (R-410A) Unit Size 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Suction Line Connection Size 3/4" [19.05 mm] I.D. 7/8" [22.23 mm] I.D. Suction Line Run Feet [m] 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt. 1 1 /8" [28.58 mm] O.D. Std.* 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] NOTES: * line size Using suction line larger than shown in chart will result in poor oil return and is not recommended

17 NOTE: FLANGES ARE PROVIDED technical data (cont d) INDOOR COILS RCFM- [14.06 kw] 60 = 60,000 BTU/HR [17.58 kw] Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position Uncased Coil Airflow: HU = A/C or Heat Pump, Upflow/Downflow Refrigerant M = R-410A (16 SEER) F = Product Generation Classification C = Coil Rheem Pricing Effective: June 2011 FORM NO. C REV. 3 Supersedes Form No. C Rev. 2 Table 1: Coil Specifications/Airflow Pressure Drop Coil Model Number Approx. Design Air Flow CFM [L/s] Range Face Area Sq. Ft. [m 2 ] Fins-in. Rows Deep NOTE: Represents Coil-Only Airflow Ratings 600 [283] HIGH EFFICIENCY COOLING COILS 600/ /2 [283/376] [0.53] [.017] /800 [283/376] 900/1200 [424/566] 900/1200 [424/566] 1200/1600 [566/755] 1200/1600 [566/755] 1300/1700 [614/802] 5.70 [0.53] 5.70 [0.53] 5.70 [0.53] 8.55 [0.79] 8.55 [0.79] 9 [0.93] 16/2.05 [.014] 700 [330].12 [.029].10 [.025] 16/2 16/2 800 [378].17 [.042].15 [.037].17 [.042].15 [.037] Static Pressure Drop Through Wet Cooling Coil [kpa] (Inches W.C.) CFM [L/s] 900 [425].21 [.052].18 [.045].21 [.052].18 [.045] 1000 [472].26 [.065].23 [.057] 1100 [519].31 [.077].27 [.067] 16/2 16/ [566] 1300 [614] 1400 [661] 1500 [708] 1600 [756] 1700 [802] 1800 [850] 1900 [897].36 [.09].31 [.077].22 [.055].22 [.055] 14/3.41 [.102].37 [.092].25 [.062].25 [.062].17 [.042].28 [.07].28 [.07].20 [.05].32 [.08].32 [.08].024 [.058].36 [.09].36 [.09].27 [.067].41 [.102].41 [.102].30 [.075].34 [.085].37 [.092] Table 2: Coil Dimensions and Weights Coil Model Number Connections Sweat (in.) [mm] Cased Coil Dimensions (in) [mm] Liquid I.D. Suction I.D. A B Coil Weight (lbs.) [Kg.] /8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 7 /8 [454] 20 [508] 52 [24] /8 [9.53] 7/8 [22.23] 21 1 /2[533] 25 7 /8 [657] 28 [711] 76 [34] Shipping Weight (lbs.) [Kg.] /8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 [508] 52 [24] 60 [27] /8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 1 /2 [445] 20 [508] 52 [24] 57 [26] /8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 [508] 54 [24] 60 [27] /8 [9.53] 7/8 [22.23] 24 1 /2 [622] 25 3 /8 [645] 32 [812] 89 [40] 99 [45] Rheem Heating, 3/8 [9.53] Cooling and 7/8 [22.23] Water Heating 24 1 /2 [622] 30 1 /4 [768] 32 [812] 108 [49] 118 [54] C Weight 57 [26] 83 [38] (cont d on next page) FIGURE 1: DIMENSIONS PLENUM WIDTH 19 7 /8 [505 mm] A MINUS ONE INCH FRONT VIEW

18 Table 2: Coil Dimensions and Weights Coil Model Number Connections Sweat (in.) [mm] Cased Coil Dimensions (in) [mm] Liquid I.D. Suction I.D. A B C (lbs.) [Kg.] /8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 7 /8 [454] 20 [508] 52 [24] Pricing Effective: June 2011 Revised: Coil Weight June 2011 Shipping Replaces: Weight October 2006 (lbs.) [Kg.] 57 [26] /8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 [508] 52 [24] 60 [27] 20 [508] /8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 1 /2 [445] 52 [24] 57 [26] /8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 [508] 54 [24] 60 [27] /8 [9.53] 7/8 [22.23] 21 1 /2[533] 25 7 /8 [657] 28 [711] 76 [34] 83 [38] /8 [9.53] 7/8 [22.23] 24 1 /2 [622] 25 3 /8 [645] 32 [812] 89 [40] 99 [45] technical data (cont d) INDOOR COILS RCFM- (cont d) /8 [9.53] 7/8 [22.23] 24 1 /2 [622] 30 1 /4 [768] 32 [812] 108 [49] Weight 118 [54] FIGURE 1: DIMENSIONS PLENUM WIDTH 19 7 /8 [505 mm] A MINUS ONE INCH FRONT VIEW SIDE VIEW NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION 1/2 [12.7 mm] SUCTION LINE 1 7 /16 [36.5 mm] 7/16 [11.1 mm] LIQUID LINE 5 15 /16 [150.8 mm] 4 1 /8 [104.7 mm] 5 3 /8 [136.5 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL & HORIZONTAL) 1 13 /16 [46 mm] 2 1 /4 [57.1 mm] SECONDARY DRAIN 3/4 N.P.T. (VERTICAL) 1 1 /4 [31.7 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL) /16 [550.8 mm] Casing top and bottom openings are the same dimensions. (cont d on next page) Rheem Heating, Cooling and Water Heating

19 technical data (cont d) INDOOR COILS RCFM- (cont d) Table 3: Coil Application Coils can be matched to heating products as listed in table below. Furnace Width Coil Model (In.) (mm) Oil* Gas [356] [533] /2 [444] 14 [356] [533] [533] /2 [444] /2 [622] 24 1 /2 [622] [533] *Note: Due to the proximity of the drain pan to the high temperature oil furnace drum, horizontal left application is NOT permitted on all oil furnaces. Accessories PLENUM ADAPTER ACCESSORY RXBA-AE This plenum adapter accessory is for use with the 24 1 /2" wide cased indoor cooling and heat pump coils. This allows a 24 1 /2" wide cased coil to be installed on a 28" wide oil furnace. This is a field-installed accessory only. RXBA-AC (Upflow/Horizontal) These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size. HORIZONTAL ADAPTER KIT RXHH (See Figure 2) This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit. INDOOR COIL CASING- RXBC (See Table 5) R X B C D 17 I INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm] DESIGN SERIES COIL CASING BLOWER UNIT ACCESSORY RHEEM (cont d on next page)

20 technical data (cont d) INDOOR COILS RCFM- (cont d) Accessories (cont d) Table 4: Horizontal Adapter Kit Model No. Coil Model Horizontal Adapter Kit Model No. 2417/3617/3621 RXHH-A /4824 RXHH-A RXHH-A05 FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings Model Number Width (in.) [mm] Height (in.) [mm] Depth (in.) [mm] Weight (lbs.) [Kg.] Unit Weight Ship. Wt. (lbs.) [Kg.] Supply Air/Return Air Openings Width (in.) [mm] Depth (in.) [mm] RXBC-D17AI 17 1 /2 [445] 20 [508] 18 [8] 23 [10] 16 1 /2 [419] RXBC-D21AI 21 [533] 20 [508] 21 5 /8 20 [9] 26 [12] 20 [508] /32 RXBC-D21BI 21 [533] 28 [711] [549] 27 [12] 36 [17] 20 [508] [508] RXBC-D24AI 24 1 /2 [622] 32 1 /2 [826] 34 [16] 44 [20] 23 1 /2 [597] AIR FLOW HORIZONTAL-DUAL DIRECTION TXV REPLACEMENT KITS RXCT R-410A Coil Model TXV Kit Obsolete Kit Part No. RC*M-H*24* RXCT-FBA RC*M-H*36* RXCT-FBB RC*M-H*48* RXCT-FBD RC*M-H*60* RXCT-FBE None NOTE: Valve can be R-22 or R-410A if date code is M2308 or later. HORIZONTAL ADAPTER KIT (RXHH-) TXV CONVERSION KITS RXCT R-22 to R-410A Coil Model TXV Kit RC*A-H*36* RXCT-FBA RC*A-H*36* RXCT-FBB RC*A-H*48* RXCT-FBD RC*A-H*60* RXCT-FBE Makes Coil RC*M-H*24* RC*M-H*36* RC*M-H*48* RC*M-H*60* Coil Model R-410A to R-22 TXV Kit Makes Coil RC*M-H*24* RXCT-EBB RC*A-H*36* RC*M-H*36* RXCT-EBB RC*A-H*36* RC*M-H*48* RXCT-EBC RC*A-H*48* RC*M-H*60* RXCT-EBD RC*A-H*60* NOTE: Valve can be R-22 or R-410A if date code is M2308 or later. (cont d on next page)

21 technical data (cont d) INDOOR COILS RCFM- (cont d) Accessories (cont d) UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4) This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION 1 1 /2 [41 mm] Table 6: Uncased Coil Adapter Kit Uncased Coil Adapter Model Number RXBA A Width (in.) [mm] B14x /8 [333] B17x /8 [422] B21x /8 [511] Uncased Coil Model RCFA/L -HUxx14 -HUxx17 -HUxx21 B24x /8 [599] -HUxx /16 [196 mm] A 20 5 /16 [516 mm] FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED Note: Sliding the coil into the coil rail before attaching coil rack front

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Air Conditioners (Outdoor)

Air Conditioners (Outdoor) 14/06/13 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Designed using galvanized steel Composite base pan absorbs

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44. FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

GCS16-024-030-036-048-060

GCS16-024-030-036-048-060 Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1790-02-2607 (EN) Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-12 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

How To Install An Evaporator Coil

How To Install An Evaporator Coil EVAPORATOR COIL INSTALLATION INSTRUCTIONS EVAPORATOR COIL SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... System Requirements... Location Requirements... Drain Requirements... INSTALLATION INSTRUCTIONS...

More information

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Heating&Air Conditioning RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Amana RHF heat pumps and matching blower coils offer economy, superior heating and cooling comfort, plus installation

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES 550.46 -TG1Y (196) SPLIT-SYSTEM CONDENSING S 0 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

TECHNICAL MANUAL GDS8 & GHS8

TECHNICAL MANUAL GDS8 & GHS8 TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com

Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is

More information

Energy Efficiency. Energy Efficient Home Cooling:

Energy Efficiency. Energy Efficient Home Cooling: Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES INDEX ALLIGATOR CLIPS... 7-7 compressor lead sets... 7-7 CONNECTORS BUTT... 7-3 closed... 7-3 ELECTRICAL... 7-2 terminal adapters... 7-2 QUICK CONNECTS... 7-5 7-6 TWIST-ON WIRE... 7-2 HEAT SHRINK TUBING

More information

Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B

Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace) UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system

More information

Two-Stage Air Conditioner with Puron Refrigerant

Two-Stage Air Conditioner with Puron Refrigerant Two-Stage Air Conditioner with Puron Refrigerant Home Comfort Components Prior to Your Purchase There s a lot to consider when deciding on a new indoor comfort system. Keep in mind that Bryant has a history

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Three Phase 4TWA3030A3000C 4TWA3030A4000C 4TWA3036A3000C 4TWA3036A4000C 4TWA3042B3000A 2½ 5 Tons 4TWA3042B4000A 4TWA3048A3000C 4TWA3048A4000C 4TWA3060B3000A 4TWA3060B4000A

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7

More information

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant CoastGuard Two-Stage Air Conditioner with Puron Refrigerant MODEL 87BNC As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines for

More information

Installation Instructions

Installation Instructions 05,06 Single Package, Displacement Ventilation or Single Zone Variable Airflow Rooftop Units Electric Cooling with PURONr (R---410A) Refrigerant and COMFORTLinkt Controls Installation Instructions IMPORTANT:

More information

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling. SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS

CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS Description / Application Compact, versatile, right or left horizontal position May be used in closet, utility room, or basement Standard Finish Fully

More information

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Greensource iseries HY Model Unitary Air Handler/Fan Coil Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant Performance 17 Two-Stage Air Conditioner with Puron Refrigerant TM Enhanced Comfort, Tax Credit Eligible Cooling Things to Consider Before You Buy Puron Refrigerant Puron refrigerant is environmentally

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB

More information

Defining Quality. Building Comfort. Heating and Cooling Coils

Defining Quality. Building Comfort. Heating and Cooling Coils Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.

More information

Liebert DS Thermal Management Unit

Liebert DS Thermal Management Unit Liebert DS Thermal Management Unit System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL Economizer Coil, Dual-Cool DX with Secondary

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013 Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

Evaporator Coils. Upflow/Downflow Vertical N-Coil Transition Upflow/Downflow N-Coil Horizontal N-coil. Upflow/Downflow Uncased Vertical N-Coil

Evaporator Coils. Upflow/Downflow Vertical N-Coil Transition Upflow/Downflow N-Coil Horizontal N-coil. Upflow/Downflow Uncased Vertical N-Coil Upflow/Downflow Vertical N-Coil Transition Upflow/Downflow N-Coil Horizontal N-coil Upflow/Downflow Uncased Vertical N-Coil Upflow/Downflow Uncased A-Coil Slab Coil Cased Horizontal 50 51 Payne Upflow/Downflow

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

C26 Bulletin #210061 November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts)

C26 Bulletin #210061 November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts) NGINRING T loset Installation With Pulse21 Furnace and lectronic ir leaner Typical pplications UNS N FULL S UP- VPORTOR OILS IR-ONITIONING N HT PUMP 2 To 5 Ton (7.0 To 17.6 kw) Nominal Size OILS LOWR OILS

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information