Telebyte 209 Short Haul Modem



Similar documents
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

PXL-500 / PXL-510 Tiger Controller Quick Start Guide

Cable Specifications and Information

Cable Specifications and Information

Cabling Specifications

PXL-250: Network Wiring

Serial Cables & Adapters

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

RS-232 COMMUNICATIONS

RJ11 RS-232 Interface

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

Cabling Guide for Console and AUX Ports

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

QSE-CI-NWK-E Control Interface

Configuring the Siemens TC35 modems for use with the MI2292

Troubleshooting and Diagnostics

No Phone Line II-48 System

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Cable Pinouts. SRP I/O Module

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

Console Cables for GarrettCom Managed Products

2S RS232 Multi Serial PCI Card Installation Guide

1-Port R422/485 Serial PCIe Card

Cable Specifications. T3 Trunk Cabling APPENDIX

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Troubleshooting and Diagnostics

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Model 201 Wiegand Touchpad Reader Installation Guide

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Instructions on How to Use HyperTerminal to Test Serial Ports ...

RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Advanced Data Capture and Control Systems

Connector and Cable Specifications

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

INTRODUCTION FEATURES OF THE ICM

PCMCIA 1 Port RS EDITION OCTOBER 1999

Configuring IP to Serial with Auto Answer and Serial to IP

No Rainfall Data is Collected

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Extender for HDMI Long Range. GTV-HDMI-CAT5LR. User Manual

FOM-5A, 6A. Asynchronous Fiber Optic Modem

s!nus-elektrotechnikai bt. Industrial IT & Automation

LED Wiring and Connections

Comtrol Cable User Guide

User Manual IC-485AI

EQUIPMENT SPECIFICATIONS

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.

How to setup a serial Bluetooth adapter Master Guide

OPT SERIAL TO FIBER OPTIC CONVERTER

Balun Bulletin- CCTV Systems- Termination

Connectors and Cables

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

OMX-RS232 Control Interface

5 Printing Reports and Labels

INSTALLATION INSTRUCTIONS

Serial/ Parallel Combo PCi Card user manual

UPGRADING AND SERVICING GUIDE

RMS U GSM USB GSM Modem

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Installation & User Guide

HDCATS-100. Installation Guide

Using the Parani SD1000U/SD1000 with Carlson SurvCE

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Global Water Instrumentation, Inc.

FlexPoint T1/E1 Copper to Fiber Line Driver

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Communication Setup Application Note

MS830 / MS833 Barcode Reader v1.0 9-December-2014

System Wiring Design Guide

Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

Network Cabling Guide

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Hardware Installation and Configuration Guide

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

PL-1, Pocket Logger B

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

QSE-CI-DMX Control Interface

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Model CFA-24 Transparent Cable Farm Automation Switch

GEU Port Gigabit Switch

Building A Computer: A Beginners Guide

s!nus-elektrotechnikai bt. Industrial IT & Automation

Transcription:

Telebyte 209 This document provides installation instructions for the Telebyte 209 (Keri Systems P/N SHM-232). This short haul modem can be used to assist in long-distance, direct, connections between a host computer and an access control network. The Telebyte 209 is fully compatible with PC/AT serial communication ports and requires no external power for its operation. 1.0 Specifications 1.1 Dimensions 0.85 inches High x 1.30 inches Wide x 3.00 inches Long (2.16 cm H x 3.30 cm W x 7.62 cm L) 1.2 Connector DB-9F with screw connection terminals 1.3 Cable Run Distance Per Wire Gauge Using Belden 9502 or its equivalent, see Table 1 Data Rate (KBPS) Wire Gauge 19 24 26 9600 Baud 4.9 Miles 3.1 Miles 1.8 Miles 2.0 Installation The short haul modems are shipped in pairs. One modem is attached to the master controller on the access control network. The other is attached to the host computer's COM port. NOTE: Each short haul modem has a small switch allowing the modem to be set for use with either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE) devices. Please ensure that each modem's switch is set correctly. The switch is used to set the modem to match the type of device it is connected to. Insert a thin-blade screwdriver into the switch slot and verify the switch is turned completely counter-clockwise for a DTE application or completely clockwise for a DCE application. Applying too much pressure while turning the switch may damage the modem. NOTE: When a KDP-252 cable is used, make sure the short haul modem switch is set for a DCE application. Web: www.kerisys.com E-mail: sales@kerisys.com Page 1 of 5

Telebyte 209 2.1 Connecting to a PXL-250 Controller The DB-9 connector on the short haul modem and on the PXL-250 controller are both female. To make the short haul modem to controller connection a DB-9 male-to-male connector is provided (see Figure 1). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 1: PXL-250 Controller to Connection 2.2 Connecting to an EntraGuard Gold Controller A short haul modem may be used with an EntraGuard Gold master controller however, due to the size of the short haul modem, an extension cable must be made to allow the modem to be located outside of the controller box so the box may close properly. The DB-9 connector on the short haul modem and on the EntraGuard Gold controller are both female. To make the short haul modem to controller connection two DB-9 male connectors are required and a minimum of 3 conductor cable (length as needed). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 2: EntraGuard Gold Controller to Connection Web: www.kerisys.com E-mail: sales@kerisys.com Page 2 of 5

Telebyte 209 2.3 Connecting to the Host Computer - DB-9 to DB-9 If the host computer's COM port uses a male DB-9 connector the short haul modem can be plugged directly to the COM port (see Figure 2). Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 3: Host Computer to Connection 2.4 Connecting to the Host Computer - DB-9 to DB-25 If the host computer's COM port uses a DB-25 connector a DB-25 to DB-9 reduction plug must be used. 2.4.1 Using a "Straight-Through" Reduction Plug If the reduction plug uses straight-through wiring (pins 2 and 3 on the 25 pin side go straight through to pins 2 and 3 on the 9 pin side) make the connection as shown in Figure 3. Set the switch on the modem to the DTE position by gently turning the switch completely clockwise. Figure 4: Host Computer to Connection Straight Through Reduction Plug Web: www.kerisys.com E-mail: sales@kerisys.com Page 3 of 5

Telebyte 209 2.4.2 Using a "Twist" Reduction Plug If the reduction plug uses 2-3 twist wiring (pin 2 on the 25 pin side goes to pin 3 on the 9 pin side and pin 3 on the 25 pin side goes to pin 2 on the 9 pin side) make the connection as shown in Figure 4. Set the switch on the short haul modem to the DCE position by gently turning the switch completely counter-clockwise. Figure 5: Host Computer to Connection 2 3 Twisted Reduction Plug Web: www.kerisys.com E-mail: sales@kerisys.com Page 4 of 5

Telebyte 209 2.5 to Wiring Two sets of twisted pair cables are used to connect the short haul modems. Connect the cable between the two modems as shown in Figure 5. The shield wire is not connected at either end of the cable. Figure 6: to Wiring Diagram End of document. Web: www.kerisys.com E-mail: sales@kerisys.com Page 5 of 5