OCS-S High Resolution Digital Crane Scale



Similar documents
OCSM Series. High Resolution Digital Crane Scale. User Guide

OCS-XZ-C Series User s Guide. OCS-XZ Series Electronic Crane Scale. User s Guide - 1 -

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

Digital Air Pressure Gauge Users Manual

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

Instruction Manual Crane Scales PCE-HS Series

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

BW-500 BED WEIGHER USER MANUAL

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

High precision counting scale. Operation Manual. l RCZ-A Series

Installation and Operation Back-UPS 1250, 1300, 1500

BODY FAT & HYDRATION % MONITOR SCALE

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

4-Channel Thermometer / Datalogger

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Digital indicator 3011

User s Manual Before using the inverter, you need to read and save the safety instructions.

DC Electronic Loads 8500 series

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

DAB+ / FM Tuner Model: TU-201

Operating instructions Platform/floor scales

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Back-UPS Pro 1300/1500 Installation and Operation

Pocket DAB & FM Radio with Speaker

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

Ron 3025 Crane Scale with 1"/25mm Display

Professional Thermohygrometer

Thermistor Thermometer MODEL NO

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Virtual Measurements & Control. Flip/Flop Filler

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

DMX2PWM 9 Channel Dimmer Setup Manual

GSM Alarm System User Manual

MAGICAR M871A. Car alarm with two-way remote User s guide

INSTRUCTION MANUAL DTH Fax: (503)

MSI3460. User Guide. Measurement Systems International. Challenger 3 Crane Scales

HIGH PRECISION WEIGHING SCALE. Operation Manual. l RCZ-B Series

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

7 FUNCTION DIGITAL MULTIMETER

SHENZHEN JUNSI ELECTRONIC CO.,LTD

INDUSTRIAL INSTRUMENTATION

ADVANCED USER S GUIDE

Operation of the 500 computer. Menu. Meaning of the different knobs. Type K. Esc

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

STERILIZERS, LABORATORY DRYING OVENS

ExStik TM ph Waterproof Meters

COLOR TFT LCD MONITOR. User Manual

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

AM/FM PLL Clock/Table Radio

Hand-held thermometer Model CTH7000

MVS - Mini Video Speaker

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

Instruction Manual FL

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen Frillesås

Phoenix Body Fat Scale Manual

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

VIBRATION WATCH with:

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

STAGE SETTER-8. User Instructions. Elation Professional

EZ DUPE DVD/CD Duplicator

12 Volt 30 Amp Digital Solar Charge Controller

User Guide. Model Insulation Tester / Megohmmeter

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

CS5000 Users Manual. Intercomp Co County Road 116 Medina MN U.S.A.

Transmitter Interface Program

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FPV MONITOR. User Manual

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Ground Resistance Clamp On Tester

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

User's Guide. Pinless Moisture Meter. Model MO257

Wireless Indoor/ Outdoor Thermometer

How To Control A Battery Cell Phone With A Battery Power Control System

Microwave Meter. Instruction Manual

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

NEED MORE HELP? PLEASE SEE OUR FAQ SECTION AT:

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Table of Contents. System Requirement of MP3 Player: Connection and Downloading Downloading DRM10 Files... 8.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide

Pocket Tach 99 (PT99) Non-Contact Tachometer

LDG M-7700 External Meter for Icom IC-7700

RS DIGITAL THERMOMETER

Instruction Manual Temp 4/5/6 Temperature Meter Series

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Nokeval. User's Manual Models 301 / 302 / 305

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Transcription:

OCS-S High Resolution Digital Crane Scale

Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 2 5. Dimension & Weight... 3 6. Display & Keys... 4 Scale Keys... 4 Indicators... 4 Message... 4 7. Operations... 5 Power On/Off... 5 Zero... 5 Tare In/Out... 6 Lock/Unlock... 6 Unit Switch... 6 8. User Setup... 6 Auto-Off Timing... 6 Backlight Brightness... 7 Idle Mode Timing... 7 9. Battery Maintenance... 8 10. Troubleshooting... 8 Version: V1.0A-1 Please read this manual carefully before using.

1. Safety Guide For good performance and precise measurement, be careful with daily operation and maintenance. Do NOT overload scale. This will damage loadcell and void warranty. Do NOT leave load hung on the scale for long. This will decrease scale s accuracy and shorten loadcell s life. Inspect shackle and hook before using. Check clips, pins and screws regularly. Check battery frequently. When scale runs out of power, replace the dead batteries with new ones. Rotate load rather than scale if needed. Do NOT use scale under thunder or rain. Hang scale on shelf in dry and well-ventilated room. Do NOT place scale on the ground directly. Do NOT attempt to repair scale yourself. Contact your local representative. 2. Features This scale is a combination of sound and proven mechanical design, with today s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate. Superb Quality. Strictly in accordance with OIML R76, Chinese GB/T11883-2002 national standards, and European CE directives. Great Safety. Aluminum-casting case, high firm hook and Page 1 of 9

shackle, dedicated weighing loadcell for safety installation. Strong Reliability. Cutting-edge technology, quality integrated circuit for high performance and long-time stability. Broad Applicability. Popular and applicable in storage, textile, metallurgy industry, and so forth. Complete Function. Resolution switch, unit conversion, auto power-off, battery inspection, etc. 3. Specifications Accuracy Tare Range Zero Range Stable Time Overload Safety Load Ultimate Load Battery Battery Life Display Chinese GB/T 11883-2002 CIII eqv. OIML R76 100% F.S. 4% F.S. 10sec 100% F.S. + 9e 120% F.S. 400% F.S. 3*AA 1.5V batteries. 65hour (tested by dedicated batteries, backlight level 3, always lit) Op. Temp. -10 ~ +40 Op. Humidity 20 90% 4. Capacity 22mm/11mm HTN LCD with backlight Modal Max. Cap. Min. Cap. Res. Division OCS-01-S 100kg 1kg 0.05kg 2,000 OCS-02-S 200kg 2kg 0.1kg 2,000 OCS-03-S 300kg 2kg 0.1kg 3,000 Page 2 of 9

OCS-05-S 500kg 4kg 0.2kg 2,500 OCS-1-S 1,000kg 10kg 0.5kg 2,000 5. Dimension & Weight 130 A B 80 L C Modal A/mm B/mm C/mm L/mm N.W./kg OCS-01-S 20 43 25 220 1.0 OCS-02-S 20 43 25 220 1.0 OCS-03-S 20 43 25 220 1.0 OCS-05-S 20 43 25 220 1.0 OCS-1-S 20 43 27 230 1.4 Page 3 of 9

6. Display & Keys Scale Keys Key Name Function On/Off Short pressing: Cancel & return to weighing mode Long pressing: Power-on / Power-off Tare Short pressing: Tare in/out; Increase digit Long pressing: Zero; Move digit Hold Short pressing: Lock/unlock; Confirm & next Long pressing: Unit Switch; Input / cancel decimal point Indicators LED Name Note Stable shown when weight is stable Zero shown when weight is at zero Tared shown when scale is tared Hold shown when scale is locked lb shown when unit is lb kg shown when unit is kg UN shown when unit is User Unit Message Message Stand for Note detect weight Page 4 of 9

SETUP BATtery END OFF OVERload ERRor User Setup Menu battery life percentage save and exit power off overloading invalid operation 7. Operations Power On/Off Press for 1s to power-on scale. Scale perform initialization and power-on test, shows twice, then capacity shows, battery life percentage shows, weight detection shows and then auto zero. For information about Auto-Zero, refer to Scale Configuration in Technical Manual. Press for 1s to power-off scale. Battery life percentage shows, off message shows, and then cut off power. When 3 batteries voltage is lower than 3.2V, scale will auto power-off itself. Please replace the dead batteries with new ones. Zero Press for 1s to zero. shows. If load is in motion, or tared, or out of Manual-Zero Range, shows. For information about Manual-Zero Range, refer to Scale Configuration in Technical Manual. Page 5 of 9

Page 6 of 9 Tare In/Out In gross mode, press to tare in. shows. If load is in motion, or negative, or out of Tare Range, shows. Tare will reduce the apparent overload range of scale. For example, if a 500*0.2kg scale has a 100kg container as its tare, the scale will overload at a new weight of 401.8kg (500 100 + additional 9 divisions). In net mode, press to tare out. disappears. Lock/Unlock Press to lock screen. shows. Press to unlock screen. disappears. Press Unit Switch for 1s to switch unit in between kg, lb, and User Unit. When unit is kg, shows. When unit is lb, shows. When unit is User unit, shows. For more information about User Unit, refer to Scale Configuration in Technical Manual. 8. User Setup Press and at the same time for 1s to enter User Setup menu. shows. Auto-Off Timing Press to enter Auto-Off Timing. shows. Press to change timing value.

Auto-Off Timing can be set to: (disabled), (5min), (10min), (15min), (30min), (60min). It is disabled by default. Auto-Off function maximizes scale s battery life against people s carelessness not to power off scale when it s not working. Auto-Off starts countdown timer when there s no action or load is stable. Any key pressing or motion in load restarts countdown timer. Backlight Brightness Press to enter Backlight Brightness. shows. Press to change brightness value. Backlight Brightness can be set to: (disabled), (dim), (normal), (bright). Dim backlight brightness saves battery power dramatically. Idle Mode Timing Press to enter Idle Mode Timing. shows. Press to change timing value. Idle Mode Timing can be set to: (disabled), (5sec), (10sec), (15sec), (30sec), (60sec). It is 30sec by default. To maximize battery life, scale automatically enters Idle Mode, when there s no action or the load is stable. In Idle Mode, scale works in low-power consumption status. Any key pressing or motion in load wakes up scale from Idle Mode. Press to exit User Setup. Page 7 of 9

9. Battery Maintenance To maximize battery life, please note the following battery maintenance guide. This scale is powered by a 3 AA 1.5V batteries. Battery house can be opened by screwing off 2 screws. Depending on backlight brightness and idle mode setting, normally, battery works over 65 hours. In order to conserve battery life, enable Auto-Off and Idle Mode, dim backlight brightness. To obtain maximum service life, battery should be stored between -20 (-4 F) and +50 (122 F). Stored batteries should be recharged every three months. When 3 batteries voltage is lower than 3.2V, scale will auto power-off itself. Please replace the dead batteries with new ones. 10. Troubleshooting Simple problems can be resolved as below listed solution. If problems still exist, please contact your local representative. Symptom Possible Cause Suggested Solution not power-on after is pressed discharged / defective battery defective On/Off key defective power cable check battery and replace press harder and keep pressing for 2s open front panel, check power cable Page 8 of 9

backlight flashes no action taken after key pressed weight reading not stable weight reading not zero when no load large error in weight reading defective mainboard discharged battery scale is disturbed defective key load in motion weak Anti-Motion damped loadcell or mainboard defective mainboard discharged battery load-cell stressed too long loadcell drifts scale not zeroed before applying load wrong unit scale requires calibration defective loadcell or mainboard contact representative replace battery re-plug power cable contact representative keep load stable change Anti-Motion level dry loadcell or mainboard contact representative replace battery hang scale in storage contact representative Manual Zero scale before loading switch to correct unit calibrate scale contact representative Page 9 of 9